• 제목/요약/키워드: Chiller System

검색결과 190건 처리시간 0.032초

Design Effect of Different Components and Economic Evaluation of an Adsorption Chiller on the System Performance

  • Bidyut B. Saha;Shigeru Koyama;K.C. Amanul Alam;Lee, Jong-Boong
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.17-22
    • /
    • 2002
  • A conventional silica gel/water adsorption chiller has been analyzed numerically. A novel non-dimensional mathematical model has been presented to analyze the design effect of different components of an adsorption chiller. The design parameters of this system are characterized by the number of transfer unit, NTU, of different components and the inert material alpha number, ${\alpha}$of different components of the systems. Results show that condenser NTU$\sub$a/ has the most influential effect on the system performance, which is fellowed by absorber NTU$\sub$e/. It is also seen that coefficient of performance (COP) and non-dimensional specific cooling capacity increases with the increase of NTU$\sub$a/ and NTU$\sub$e/, but decreases with the increase of inert material alpha number. A thermo-economic data of the adsorption chiller and some other heat pump systems those are in practical operation are also presented.

  • PDF

빙축열 시스템과 흡수식 냉온수기 공조 방식의 경제성 분석 (An Economic Analysis of Ice Thermal Storage and Absorption Chiller-Heater Systems)

  • 임현우;김영일;김강산;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.218-223
    • /
    • 2009
  • Cost related to building equipment accounts for about 85% of the life cycle cost of buildings. Therefore proper selection of air-conditioning system is important for reducing the overall cost of buildings. In this study, large capacity ice thermal storage and absorption chiller-heater for air-conditioning a building with a floor area of $9,900\;m^2$ are compared economically. For easy input and analysis, an Ms Excel VBA program has been developed. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. Under the assumptions made in this study, overall cost of an absorption chiller-heater is less than that of an ice thermal storage, but this is not absolute and different outcome may result if different assumptions are made. This study is useful for those who are interested in choosing an economical air-conditioning system for large-size buildings with simple calculations.

  • PDF

칠러(Chiller) 냉각장치 침전물에 미치는 마그네슘의 영향에 관한 환경 광물학적 연구 (Environmental Mineralogy on the Mg Effects of Chiller Precipitates)

  • 김윤영;장세정;장윤득;김정진
    • 한국광물학회지
    • /
    • 제18권2호
    • /
    • pp.117-125
    • /
    • 2005
  • 산업체에서 사용하고 있는 칠러 냉각 장치에는 침전물이나 부유물이 많이 발생한다. 칠러 냉각장치에 마그네슘을 적용시켰을 때 나타나는 냉각수와 침전물 및 부유물의 변화를 연구하기 위하여 ICP-AES, IC, XRD, SEM 분석을 실시하였다. 칠러 냉각장치에 Mg를 적용할 경우 대부분의 용해 성분이 감소하는 경향을 보여주고 있어 냉각수의 수질이 상당히 개선되었다. 또한 유기물 형태로 존재하던 부유물이나 침전물이 거의 생성되지 않아 유기물 생성을 억제시키는 효과도 있는 것으로 판단된다.

이코노마이저를 채용한 스크류 냉동기에서 R22와 R407C의 부분부하 성능실험 (Part-Load Performance Test of a Screw Chiller with Economizer using R22 and R407C)

  • 장영수;이용철;김영일
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.902-909
    • /
    • 2003
  • Screw compressor type chillers are widely used in refrigeration for capacity over 30 RT. In general, chillers operate under part-load conditions. Therefore, information on characteristics at part-load is very important in view of chiller performance and energy economy. In this study, performance tests of part-load and economizer system using R22 and R407C have been performed for various secondary fluid temperatures. Adoption of an economizer system increased the cooling capacity and improved COP except for lower part-load condition when injection volume ratio is 1.01. For the same cooling capacity condition at part-load, COP of both non-economizer and economizer system showed similar values.

경계요소법을 이용한 터보냉동기 덕트의 내부 음향장 해석 (An Analysis of Acoustic Field for Turbo Chiller Discharge Duct by Using Boundary Element Method)

  • 전완호;이준근;정필중
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.963-970
    • /
    • 2000
  • The turbo chiller uses centrifugal compressor, which operates at about 14,500 rpm. Due to the high rpm of the impeller, the noise of chiller males one of the serious problems. The possibility of the sound reduction by using absorbing material is studied in this paper. The generated sound propagates through the duct and then radiates to the outer field. So, the use of sound absorption material inside the duct is one of the effective methods. To study the effect of location of the material, we use Boundary Element Method to analyze the sound field inside the duct system. Numerical study shows the highest sound pressure region is near the elbow of curved duct. From the numerical study, it is also shown that appropriate use of sound absorbing material at this region makes 8dB reduction of the highest noise level.

  • PDF

내면가공 핀튜브 흡수기의 열 및 물질전달특성 (Characteristic of Heat and Mass Transfer on Inner Ribbed Notched Fin Tube Absorber)

  • 설원실;권오경;문춘근;정용옥;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.478-485
    • /
    • 2000
  • An experimental study of the absorption process of water vapor into lithium bromide solution was performed. For the purpose of development of high performance absorption chiller-heater utilizing Lithium Bromide solution as working fluid, the absorber is the most effective to improve the performance of an absorber because it requires the largest heat transfer area in an absorption chiller-heater system. This paper introduces bare tube and inner ribbed notched fin tube for the absorber of absorption chiller-heaters. Inner ribbed notched fin tube has about 10∼20% higher heat and mass transfer performance than bare tube conventionally used in absorbers and the it is expected to perform high heat and mass transfer. This paper will provide important information on the selection of absorber tubes in commercial absorption chill-heaters.

  • PDF

수소충전용 직접 및 간접 냉각시스템 비교 평가 연구 (The Study of Comparison of Cooling System for H2 Discharge Station)

  • 이현찬;이종열;배찬효;허정호;전재영
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.163-169
    • /
    • 2019
  • This study is a research to compare efficiency of new cooling system (chiller, pre-cooler) to that of the conventional system at the hydrogen refueling station (HRS). This study includes contents for thermodynamic comparison of cooling system for HRS and comparison of pros and cons of its components. So It is to establish design concept of cooling system of HRS supplying with fuel cell electric vehicle (FCEV). HRS is charging high pressure H2 (700 bar) to FCEV. However cooling system is need to prevent temperature rise in tank. This cooling system consists of pre-cooler and chiller system.

EV 상용차용 히트펌프 시스템 냉방 운전 특성에 관한 연구 (A Study on Performance Characteristics of Heat Pump System on Cooling Mode for Light-duty Commercial Electric Vehicles)

  • 전한별;김정일;원헌주;이호성
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.69-75
    • /
    • 2019
  • 본 연구의 목적은 EV 경상용차에 적용되는 히트펌프 시스템에 대한 냉방 성능 특성을 실험적으로 분석하는 것이다. EV 경상용차가 운전되는 냉방 운전조건인 외기온도 35 ℃, 내기온도 25 ℃ 상황에서, 히트펌프 시스템의 냉방 특성을 분석하고자, 냉각수의 온도조건, 전동식 압축기 회전수 조건 변화에 대해서, 실험을 진행하였고, 그 결과를 분석하였다. 전동식 압축기 회전수가 증가할수록 냉방 성능이 평균 8.0 %가 증가하였고, 전동식 압축기 소비전력은 27 %가 증가하여서, 시스템 효율은 16.4 %가 감소하는 결과를 보여주고 있다. 전자장비 냉각을 위한 냉각수의 폐열을 활용하기 위하여서, 냉매랑 냉각수가 열교환 하는 칠러를 본 시스템에 적용하였다. 칠러에 적용되는 냉각수의 온도를 35 ℃에서 55℃로 변화시켰을 때, 응축 열원의 증가로 인하여서, 시스템 효율이 평균적으로 18.2 %가 떨어지는 결과를 보여주고 있다. 냉각수 유량 변화 측면에서, 운전 조건을 변화시켰지만, 냉방 성능에는 큰 변화를 보이고 있지 않았다. 향후, 냉각수 폐열을 사용하여서, 히트펌프 시스템에 대한 난방 성능 향상을 위한 연구가 필요한 상황에서, 관련 연구에 추가 할 예정이다.

대학 캠퍼스 냉·난방시스템 최적화 방안 연구 (A Study on the Optimization of Heating and Cooling System in University Campus)

  • 박소연;박효순;이상혁;김지연;홍성희
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.139-144
    • /
    • 2010
  • The demands are increasing for the efficient heating and cooling system and thermal comfort environment because of changes in climate and environment, and deterioration of buildings and facilities can cause education budget to increase. So the study to apply heating and cooling system to university is urgently needed to improve an optimum energy saving system, educational environment and convenience of maintenance. For this reason, we selected a university campus in Seoul then came to understand the current situation and found some problems. We drew alternatives from comparative analysis of them. It selects representative building and carries out economic analysis to evaluate characteristics of energy consumption and economics on each type of heating and cooling system. As a result we drew the optimum system from those processes as previously stated. We studied 3 available systems, absorption chiller, EHP(Electric Heat Pump) and GHP(Gas Engine Heat Pump). According to LCC analysis suppose that the value of EHP is 1, it came out that the value of absorption chiller is 1.5 and the value of GHP is 2.2. This study, suggesting the optimum heating and cooling system, will support educational and research activities furthermore effect to maximize energy efficiency. Ultimately it is expected that it will contribute to make eco-friendly Green Campus.

공랭식 변유량 냉매 냉동기를 적용한 수조 온도의 정밀 제어 (Precision Control of Water Bath Temperature using Air Cooled Variable Refrigerant Flow Chiller)

  • 정광주;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.27-34
    • /
    • 2018
  • This study compared constant water bath performances of conventional water-cooled refrigerator and electric heater with an air-cooled VRF chiller and electric heater equipped with optimal control algorithm. In heating mode, the air cooled VRF chiller and electric heater combination reduced the set temperature arrival time by an average of 42 minutes, and energy was also reduced by 18%. In cooling mode, the two systems took 70 minutes to reach the set temperature and showed no difference. Energy was reduced by 33.5% with the new system. For constant temperature maintaining experiment, after reaching the set temperature of $15^{\circ}C$, $20^{\circ}C$ and $22^{\circ}C$, temperature deviations were all in the range of $-0.2^{\circ}C$ to $+0.1^{\circ}C$. Energy was reduced by an average of 84.9%. Through this study, possibility of precise temperature control by an air cooled VRF chiller system was confirmed.