The Suggestion of Reliability Improvement Method based on Failure Trend Analysis of Chiller (냉동기 고장경향분석을 통한 설비신뢰도향상 방안 제시)

  • Lee, Sang Dae;Yeom, Dong Un;Hyun, Jin Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.251-255
    • /
    • 2015
  • Chiller system plays an important role of maintaining room temperature constantly by supplying chilled water to Heating, Ventilating and Air Conditioning(HVAC)or area room cooler equipment during plant normal operation or accident condition. Chiller failures are one of the most frequently occurring equipment failures. If the types of chiller failures are analyzed and grouped thoroughly, it would be helpful to make chiller maintenance strategy at the plants. That would enhance equipment reliability of chiller in the end. In this paper, chiller failure data during three years were analyzed and categorized by specific failure code. In addition, the various proposals to improve equipment reliability of chiller were suggested such as Preventive Maintenance Optimization(PMO) strategy and performance monitoring reinforcement and so on.

Optimal Control Strategies for Energy Saving of Central Cooling System with Outdoor Air Temperature Changes (외기온도 변화특성을 고려한 중앙냉방시스템의 에너지 절감 최적제어에 관한 연구)

  • Park, Ki-Tae;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4260-4266
    • /
    • 2015
  • In this study, the optimal control method for minimizing of energy consumption for central cooling system with proper occupant comfort level is researched by simulation. The optimal control method is that the optimal set temperatures such as the condenser water temperature, supply air temperature, and chilled water temperature with environment variable change such as outdoor air dry-bulb and wet-bulb temperatures are obtained by suggested optimal control algorithm with maximum and part building load. The TRNSYS program is used for system modeling and the control performances with the suggested optimal control method are compared with the existing control method of fixed set points. The suggested optimal control method shows better responses in energy consumption in comparison with existing control ones.

Physical and Biochemical Mechanisms Associated with Beef Carcass Vascular Rinsing Effects on Meat Quality: A Review

  • Hwang, Koeun;Claus, James R.;Jeong, Jong Youn;Hwang, Young-Hwa;Joo, Seon-Tea
    • Food Science of Animal Resources
    • /
    • v.42 no.3
    • /
    • pp.389-397
    • /
    • 2022
  • Carcass vascular rinsing and chilling involves infusing a chilled isotonic solution (98.5% water and a blend of mono- and di-saccharides and phosphates) into the vasculature immediately upon exsanguination. Primary purposes of carcass vascular rinsing are to (1) effectively remove residual blood from the carcass; (2) lower internal muscle temperature rapidly; and (3) optimize pH decline by effective delivery of glycolytic substrates in the rinse solution. Previous studies have revealed that the beef carcass vascular rinsing early postmortem positively affects meat quality, product shelflife, and food safety. Thus, the objective of this review is to provide a more comprehensive understanding of the physical and biochemical mechanisms associated with beef carcass vascular rinsing, focusing on the relationship between quality attributes (CIE L*, a*, b*; chemical states of myoglobin; oxygen consumption and sarcomere length) and muscle metabolic response to various substrate solutions (Rinse & Chill®, fructose, sodium phosphate, and dipotassium phosphate) that stimulate or inhibit the rate of glycolysis early postmortem. In addition, this review discusses the absence of metabolite residues (phosphorus, sodium, and glucose) related to the application of the chilled isotonic solution. This review primarily focuses on beef and as such extending the understanding of the mechanisms and meat quality effects discussed to other species associated with vascular rinsing, in particular pork, may be limited.

Vascular rinsing and chilling carcasses improves meat quality and food safety: a review

  • Koeun, Hwang;James R., Claus;Jong Youn, Jeong;Young-Hwa, Hwang;Seon-Tea, Joo
    • Journal of Animal Science and Technology
    • /
    • v.64 no.3
    • /
    • pp.397-408
    • /
    • 2022
  • Rinse & Chill® technology (RCT) entails rinsing the vasculature using a chilled isotonic solution (3℃; 98.5% water and a blend of dextrose, maltose, and sodium phosphates) to rinse out the residual blood from the carcass. Infusion of pre-chilled solutions into intact animal carcasses immediately upon exsanguination is advantageous in terms of lowering the internal muscle temperature and accelerating chilling. This technology is primarily used for purposes of effective blood removal, favorable pH decline, and efficient carcass chilling, all of which improve meat quality and safety. Although RCT solution contains some substrates, the pre-rigor muscle is still physiologically active at the time of early postmortem and vascular rinsing. Consequently, these substrates are fully metabolized by the muscle, leaving no detectable residues in meat. The technology has been commercially approved and in continuous use since 2000 in the United States and since 1997 in Australia. As of January 2022, 23 plants have implemented RCT among the 5 countries (Australia, US, Canada, New Zealand, and Japan) that have evaluated and approved RCT. All plants are operating under sound Sanitation Standard Operation Procedures (SSOP) and a sound Hazard Analysis Critical Control Point (HACCP) program. No food safety issues have been reported associated with the use of this technology. RCT has been adapted by the meat industry to improve product safety and meat quality while improving economic performance. Therefore, this review summarizes highlights of how RCT technically works on a variety of animal types (beef, bison, pork, and lamb).

Evaluation of Microbiological, Physicochemical, and Sensory Properties of Galbi-jjim Prepared by Sous-vide and Cookchill Method at Different Temperatures

  • Shin, Weon-Sun;Kim, Kyeong-Mi;Park, Jin-Hee;Cho, Tae-Im
    • Food Science of Animal Resources
    • /
    • v.30 no.5
    • /
    • pp.722-729
    • /
    • 2010
  • The aim of this study was to evaluate the physico-chemical, sensory, and microbiological properties of ready-to-eat Korean traditional seasoned beef ribs ("galbi-jjim") prepared by sous-vide/cookchill technology during storage at three different temperatures (4, 10, and $20^{\circ}C$). Beef short ribs marinated in soy sauce for 24 h at $3^{\circ}C$ were packed with vegetables under vacuum. Vacuum-packed beef ribs mixed with vegetables were heated at $90^{\circ}C$ for 90 min in a water bath, and then immediately chilled below $3^{\circ}C$ within 120 min in an ice slurry. Physicochemical (pH, water activity, TBARS, $L^*a^*b^*$ color, and texture profile), sensory (appearance, odor, flavor, texture, and acceptance) and microbiological (Coliform, Escherichia coli, food-borne pathogenic bacteria) properties of the samples were determined during storage at different temperatures. Results showed that pH, $a_w$, and sensory evaluation of products were not affected in any consistent way as a function of either storage duration or temperature. Coliform, E. coli and food-borne pathogens were not detected during storage at any temperature. However, TBARS significantly increased during storage period (p<0.05). Based on TBARS values, SV/CC "galbi-jjim" can be stored for 15 d, 12 d and 1 d at 4, 10 and $20^{\circ}C$, respectively.

Fabrication of a Hybrid Superhydrophobic/superhydrophilic Surface for Water Collection: Gravure Offset Printing & Colloidal Lithography (수분수집을 위한 초발수/초친수 복합 표면 제작: 그라비아 옵셋 프린팅과 콜로이달 리소그래피 공정)

  • Ji, Seung-Muk;Kim, In-Young;Kim, Eun-Hee;Jung, Jie-Un;Kim, Wan-Doo;Lim, Hyun-Eui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.1
    • /
    • pp.19-24
    • /
    • 2012
  • We demonstrate the desert beetle back mimicking hybrid superhydrophilic/superhydrophobic patterned surface by using the combination method of colloidal lithography and gravure offset printing for nano and micro patterning, respectively. The two methods are cost-effective and industrially available techniques compared to the other nano/micro patterning methods. To verify the water collecting function of the hybrid surface, the water condensation behavior is investigated on the chilled surface in ambient temperature and high humidity. Due to the synergetic effect of drop and film wise condensation, the hybrid superhydrophobic/superhydrophilic surface shows the higher efficiency than one of single wettability surfaces. The work is underway to get the good patterns of hybrid surfaces for water collecting from the dew or fog.

Experimental Study on Heat Transfer Characteristics of HFC134a for Enhanced Tubes Used in a Flooded Evaporator (HFC134a 만액식 증발전열관 외부형상 변화에 따른 열전달 특성실험)

  • Yang, Seung-Woo;Lee, Young-Su;Jeong, Jin-Hee;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.971-976
    • /
    • 2006
  • The objectives of this paper are to study the characteristics of pool boiling heat transfer for enhanced tubes used in the evaporator of turbo chiller and to provide a guideline for optimum design of an evaporator using HFC134a. Three different enhanced tubes are tested at 4 different saturation temperatures. The wall super heated temperature difference ranges from $0.5^{\circ}C\;to\;3.5^{\circ}C$. The refrigerant, HFC134a evaporates on the outside of the tube while the chilled water flows inside the tube. This study provides experimental heat transfer coefficients for evaporation on the enhanced tubes. It is found that the turbo-II tube provides the highest heat transfer coefficient.

Study and Survey of Operating Efficiency with Cool Storage System (빙축열냉방시스템의 운전효율에 관한 조사연구)

  • 손학식;심창호;김강현;김재철
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study is to maintain high efficiency and reasonable use of cool thermal storage systems operated in the domestic building sector. As the result of efficiency test from the five types of operated cool storage systems on the condition that COP ranges are 2.6 to 3.4 during the day time and 2.1 to 3.0 during the night time and it decreased by more than 30% of rated COP given 3.8 to 3.0. The Analysis of cool storage rate shows that only 3 (21.4%) systems out of 15 buildings hold to over 40% capacity for its total capacity. To prevent the decrease in operating efficiency, it should correct the malfunction of 3-way valve and expansion valve and the mistake of control values for schedule program and increase cooling tower capacity. In order to improve piping line, it needs bypass brine line off refrigerator, separation of chilled water line with Ice Slurry system at day and night time and speed control of chilled and warm water pumps. This study does require the more studies on improving difficulty of increasing cooling load with Ice on Coil system, waterproofing with Ice Ball system, COP drop during the night time with Ice Lens, low operating temperature during the day time with Ice Slurry and increasing of Power loss due to hot gas de-icing with Ice Harvest in the future.

Evidence of Significant Effects of Stunning and Chilling Methods on PSE Incidences

  • Park, B.Y.;Kim, J.H.;Cho, S.H.;Hah, K.H.;Lee, S.H.;Choi, C.H.;Kim, D.H.;Lee, J.M.;Kim, Y.K.;Ahn, J.N.;Hwang, I.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.2
    • /
    • pp.257-262
    • /
    • 2007
  • The current study was conducted to investigate the optimum stunning voltage and chilling regime with emphasis on reduction in pale, soft and exudative (PSE) pork. The experiments were conducted at seven Korean major pig abattoirs using a total of 91,082 industrial population. Frequencies of PSE meat was found to be significantly (p<0.05) increased as stunning voltage was elevated from 220-240 (13.14%), 250-280 (29.32%) to 430 volts (36.74%). Chilling methods after slaughter, either with cold water showing or rapid chilling reduced PSE meat by 22% compared to a classic chiller-based slow chilling regime. The current study also revealed that chiller temperature during the first 90 minutes had a significant (p<0.001) effect on PSE incidences. Pigs chilled between -5 to $7^{\circ}C$ resulted in the lowest PSE meat (17.8%), followed by higher than $7^{\circ}C$ (21.3%) and lower than $-5^{\circ}C$ (37.5%). The current data implies that low voltage stunning method (eg., 220-240 volts), followed by rapid chilling regime, maintaining chiller temperature between approximately -5 to $7^{\circ}C$ could reduce PSE incidences.

Evaporating heat transfer characteristics of Aluminum-brass tube for seawater cooling system using R-134a (해수냉각시스템용 Aluminium Brass Tube의 R-134a 증발열전달 특성)

  • Kang, In-Ho;Seol, Sung-Hoon;Yoon, Jung-In;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.197-201
    • /
    • 2017
  • Most fishing vessels use an ice cooling system to manage and store captured fish. However, it is difficult to maintain an adequate temperature and salt concentration as well as operating time limitations in ice cooling systems. The purpose of this study is to investigate the heat transfer characteristics of flooded-type evaporators for a seawater cooling system to maintain proper seawater temperature in a fish tank. Experiments were conducted to investigate the heat transfer characteristics by changing the seawater temperature, flow rate, and saturation temperature of the refrigerant. It was confirmed that the heat transfer coefficient of an aluminum-brass tube was approximately 10% higher than that of a copper-nickel tube at the same heat flux. Furthermore, it was confirmed that applying the aluminum-brass tube to the heat transfer tube of a seawater heat exchanger was effective in terms of heat transfer. A comparison of the overall heat transfer coefficient of a single-tube heat exchanger and the flooded-type multi-tube heat exchanger for an 18-kW cooling system showed that the heat transfer coefficient of the single-tube heat exchanger was 25% higher under the same conditions. These results are considered to be important data for designing a flooded-type multi-tube heat exchanger.