• Title/Summary/Keyword: Chilled water temperature

Search Result 68, Processing Time 0.023 seconds

An Experimental Study on the fluidity properties of Polymer Concrete According to Replacement Ratio of Rapidly-Chilled Steel Slag and polymer resin (급냉 제강 슬래그 대체율과 폴리머 수지에 따른 폴리머 콘크리트의 유동특성에 관한 실험적 연구)

  • Choi, Duck-Jin;Kim, Jae-Won;Sun, Joung-Soo;Kim, Ha-Suk;Hwang, Eui-Hwan;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.75-78
    • /
    • 2007
  • The steel slag, a by-product which is produced by refining pig iron during the manufacture of steel, is mainly used as road materials after aging. It is necessary to age steel slag for long time in air because the reaction with water and free-CaO in steel slag could make the expansion of volume. This problem prevents steel slag from being used as aggregate for concrete. However, steel slag used in this study was controled by a air-jet method which rapidly cools substance melted at a high temperature. The rapidly-chilled method would prevent from generation of free-CaO in steel slag. Also, Molten steel slag rapidly-chilled by air in high speed becomes a fine aggregate of nearly spherical shape. This study dealt with the influence of the using rate of rapidly-chilled steel slag and polymer resin on fluidity of polymer concrete, as a results Since RCSS has spherical shape and high density, up to replacement ratio of 100%, increases concrete fluidity under same polymer content and decrease polymer content in order to secure the same fluidity

  • PDF

A District Cooling System using Ice Slurry for the Uncertain Cooling Load of the Future and its Economic Evaluation (미래의 불확실한 냉방부하에 대한 아이스슬러리를 이용한 지역냉방시스템 및 경제성 평가)

  • Lee Yoon-Pyo;Ahn Young-Hwan;Yoon Seok-Mann
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.776-782
    • /
    • 2006
  • A new district cooling system using ice slurry for the uncertain cooling load of the future is presented. The chilled water produced by the absorption chillers is used for the base cooling load. The temperature of the chilled water is reduced by mixing of ice slurry depending on increasing of the cooling load. Finally, IF of the ice slurry is increased up to 10% at the peak load. The transporting mass flow rate is decreased down to 44.7%, and the diameter of the main pipe is decreased down to 66.7%, but the diameter of the branched pipe is designed as the same size of the chilled water.

An Experimental Study on the Cooling Operation Characteristics for Different Entering Water Temperatures In Geothermal Heat Pump System (지열히트펌프 시스템의 EWT의 변화에 따른 냉방운전 특성에 관한 실험적 연구)

  • Ahn, Byung-Chun;Kim, Jae-Wan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, an experimental study on the cooling operation characteristics for different entering water temperatures in geothermal heat pump system are carried out by using Lab VIEW system program Set-point temperature controls for cooling water and supply air temperatures is applied to analyze the energy consumption and control performances. As a result, the system responses show that different entering water temperatures(EWT) effect greatly on the energy consumption and system COP.

A study on design for free cooling system using dry cooler (드라이쿨러를 적용한 외기냉수냉방 시스템 설계에 관한 연구)

  • Yoon, Jung-In;Baek, Seung-Moon;Heo, Jeong-Ho;Kim, Young-Min;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1027-1031
    • /
    • 2014
  • Free cooling system is used to reduce energy consumption of cooling system. Free cooling system is consisted of cooling group and dry-cooler in which heat exchange of chilled water and out air is conducted. Although this system has an excellent energy saving effect in place having cooling load regularly, data or material of design for free cooling system is lacked. In this study, characteristics analysis of free cooling system is conducted through software HYSYS with changing some facts. The main result is following as : Dry-cooler capacity is influenced by out air temperature, required chilled water temperature and LMTD(Logarithmic Mean Temperature Difference) of heat exchanger. As out air temperature is more low, dry-cooler capacity become increased. in addition, as required chilled water temperature is more high and LMTD is more low, the out air temperature range is widened for using dry-cooler. If out air temperature is below $0^{\circ}C$, antifreeze need to be used because freeze and burst can be occurred. In case of South Korea, antifreeze of 34% of ethylene glycol concentration is proper. When compressor load of R22, R134a and R407C is compared, considering environmental regulation and energy consumption, R134a is best working fluid.

Heat Transfer Characteristics of Fin-Tube Heat Exchanger Coated with FAPO Zeolite Adsorbent at Different Operating Conditions (FAPO 제올라이트 흡착제 코팅을 통한 핀-관 열교환기 운전조건별 열전달 성능특성)

  • Jeong, Chul-Ki;Kim, Yong-Chan;Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.21 no.3
    • /
    • pp.93-101
    • /
    • 2017
  • In conventional adsorption chamber, adsorbent is embedded in between heat exchanger fins by wire mesh. This method impedes heat and mass transfer efficiency. So in this study, to improve the heat transfer performance of heat exchanger, a fin-tube exchanger was coated with FAPO (Ferroaluminophosphate) zeolite adsorbent. The fin-tube heat exchanger has a fin pitch of 1.8 mm with a variation of adsorbent coating thickness of about 0.1 mm, 0.15 mm and 0.2 mm. By varying cooling water temperature and chilled water temperature respecively, heat transfer rate and overall heat transfer coefficient were investigated. As a result, the heat transfer rate and overall heat transfer coefficient increase with decreasing cooling water temperature and increasing chilled water temperature. Under the basic conditions, the heat transfer rate of heat exchanger with 0.2 mm coating thickness is 11% and 43% higher than that of 0.1 mm and 0.15 mm, respectively. The overall heat transfer coefficient is $189.1W/m^2{\cdot}^{\circ}C$, it is two times lager than that of 0.1 mm.

Cycle Simulation of an Adsorption Chiller Using Silica Gel-water (실리카겔-물계 흡착식 냉동기 사이클 시뮬레이션)

  • Kwon, Oh-Kyung;Yun, Jae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.116-124
    • /
    • 2007
  • An adsorption chiller is expected to have high energy-efficiency in utilizing the waste heat exhausted from a process. The objective of this paper is to investigate the performance of silica gel-water adsorption chiller from the cycle simulation and to provide a guideline for design of the adsorption chiller. The effect of cycle time, inlet temperature and water flow rate on the cooling capacity and COP is quantified during the cycle operation. It is found that the performance of adsorption chiller is more sensitive to the change of inlet water temperature rather than the water flow rate. It is concluded that the COP is 0.57 in the standard conditions(hot water $80^{\circ}C$, cooling water $30^{\circ}C$, chilled water inlet temperatures $14^{\circ}C$ and cycle time 420sec).

Cold Air/Water Distribution System with Ice Storage (빙축열을 이용한 저온급기/급수 냉방 시스템)

  • Kim, K.H.;Lee, J.W.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.20 no.2
    • /
    • pp.125-133
    • /
    • 1991
  • This paper presents some design guidelines for using cold air/water distribution to cool commercial and industrial buildings. Cold air /water distribution systems provide primary air/water for space conditioning at nominal temperature between $3^{\circ}C$ and $10^{\circ}C$ ($4{\sim}5^{\circ}C$ might be recommendable for better selection). By using lower temperature primary air/water equipment could be downsized, means lower first costs, and often reduce annual energy costs up to 50% less than that of the conventional ($13^{\circ}C$) system. This concept takes full advantages of the $2{\sim}4^{\circ}C$ chilled water (brine) available with ice storate systems.

  • PDF

Effect of Salicylic Acid on Growth and Chilling Tolerance of Cucumber Seedlings

  • Lee, Gui-Soon;Hong, Jung-Hee
    • Journal of Environmental Science International
    • /
    • v.11 no.11
    • /
    • pp.1173-1181
    • /
    • 2002
  • The present study was undertaken to investigate the effect of low temperature and salicylic acid(SA) on the chilling tolerance of acclimated and nonacclimated cucumber(Cucurmis sativus L.) seedlings. The acclimation phenomenon was characterized in chilling-sensitive cucumber seedlings and found to have a significant effect on the survival and shoot dry weights. The injuries experienced by the acclimated seedlings in the third leaf stage were on average smaller by half than those experienced by the nonacclimated seedlings. Chilling also caused a large increase in the free proline levels, regardless of the acclimation status. Exogenous treatment with SA(0.5mM) resulted in improved growth and survival of the nonacclimated chilled seedlings, indicating that SA induced chilling tolerance and SA and acclimation had common effects. The application of cycloheximide in the presence of SA restored the acclimation-induced chilling tolerance. The elevated proline level observed in the cold-treated and SA-treated plants was more pronounced in the light than in the dark at a chilled temperature, indicating that endogenous proline may play a role in chilling tolerance by stabilizing the water status in response to chilling. From these results it is suggested that SA provided protection against low-temperature stress by increasing the proline accumulation, and pre-treatment with SA may induce antioxidant enzymes leading to increased chilling tolerance.

Cycle simulation of a triple effect LiBr/water absorption chiller (삼중효용 LiBr/물 흡수식 냉방기의 사이클 시뮬레이션)

  • 조광운;정시영;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.79-87
    • /
    • 1998
  • Basic design of a 50USRT(175㎾) triple effect absorption chiller driven by hot gas has been carried out for both parallel and series flow cycles. Parallel flow cycle showed higher COP, however, the temperature in the generator was also higher than that in series flow cycle. Dynamic operation behavior of a parallel flow system at off-design conditions, such as the change in heat transfer medium temperature or the construction change of the system components, has been investigated in detail. It was found that the cooling capacity was seriously decreased by reducing hot gas flow rate and UA-value in the high temperature generator. However, the system COP was improved, because thermal load in the system components was reduced. The COP and the cooling capacity was found to be improved as cooling water temperature decreased or chilled water temperature increased. The optimum ratio of solution distribution could be suggested by considering the COP, the cooling capacity and the highest temperature in the system, which is critical for corrosion.

  • PDF

Quality of Duck Breast and Leg Meat after Chilling Carcasses in Water at 0, 10 or $20^{\circ}C$

  • Ali, Md. Shawkat;Yang, Han-Sul;Jeong, Jin-Yeon;Moon, Sang-Hun;Hwang, Young-Hwa;Hwang, Young-Hwa;Park, Gu-Boo;Joo, Seon-Tea
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.12
    • /
    • pp.1895-1900
    • /
    • 2007
  • An experiment was carried out to investigate the effects of different chilling temperature on duck breast and leg meat quality. Duck carcasses were chilled for 30 minutes in water at either $0^{\circ}C$, $10^{\circ}C$ or $20^{\circ}C$ within 20 minutes of post mortem with 6 carcasses per group. Results showed no significant effects of chilling temperature on ultimate pH, protein solubility, sarcomere length and shear force value for duck breast or leg meat (p>0.05). Leg meat had higher ultimate pH, redness and shear force value, lower cooking loss, lightness, yellowness and protein solubility values than breast meat. The interaction of meat type and chilling temperature on cooking loss was significant (p<0.05). The effect of chilling temperature on cooking loss was more severe in leg meat than breast meat and $20^{\circ}C$ chilling resulted in significantly higher cooking losses than the other chilling temperatures. Results of this experiment revealed that duck carcass can be chilled at $10^{\circ}C$ without any harmful effect on meat quality including toughness of meat.