• Title/Summary/Keyword: Chevron

Search Result 213, Processing Time 0.024 seconds

The Differences of Fixation Method in Proximal Chevron Osteotomy for Hallux Valgus: K-Wire, Cannulated Screw, Plate (무지외반증에서 근위 갈매기형 절골술 후 고정 방법에 따른 차이: K-강선, 유관나사, 금속판)

  • Kim, Taik-Seon;Kim, Hak-Jun;Park, Young-Hwan;Lim, Hyung-Tae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.62-67
    • /
    • 2011
  • Purpose: The authors evaluated the differences between K-wires and Cannulated screw, plate for fixing the proximal metatarsal chevron osteotomy of moderate and severe hallux valgus. Materials and Methods: There were 62 patients (79 feetz) who were moderate and severe degree hallux valgus according to the classification of Mann. They all got the proximal chevron osteotomy when correcting the deformity. We divided the patients into 4 groups, Two K-wire fixed group as A, one cannulated screw fixed group as B. Two cannulated screw fixed group as C, Plate fixed group as D, Group A were patients (26 feet) and Group B were patients z(9 feet), Group C were patients (31 feet) and Group D were patients (13 feet). Preoperative, postoperative and follow-up hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured for each patient. ANOVA test and Student t-test were done for statistical analysis. Results: Mean follow up period was 43.8 months (range: 12~82 months). Preoperative mean IMA was $16.4{\pm}3.5$, $17.7{\pm}11.3$, $17.3{\pm}5.9$ and $16.6{\pm}2.3$ degrees in respectively group A, B, C, D. Immediate postoperative mean IMA was $5.6{\pm}3.4$, $7.3{\pm}4.4$, $7.6{\pm}4.4$ and $6.7{\pm}2.8$ degrees in respectively group A, B, C, D. The final mean IMA was $8.9{\pm}4.5$, $15.2{\pm}7.5$, $10.3{\pm}4.4$ and D $7.7{\pm}3.5$ degrees in respectively group A, B, C, D. There were significant statistical increase in final mean IMA of group B and C (p<0.05). Conclusion: The IMA was significantly increased in the group which used one or two cannulated screw for fixation on follow up, therefore more caution should be needed when using one or two cannulated screw fixation technique after proximal chevron osteotomy.

해외석유정보

  • Korea Petroleum Association
    • Korea Petroleum Association Journal
    • /
    • no.1 s.228
    • /
    • pp.100-106
    • /
    • 2002
  • 본란은 해외석유산업에 대한 동향과 정보를 파악하기 위하여 석유협회에서 발간중인 석유정보다이제스트 내용을 발췌하여 실은 것이다.

  • PDF

An Experimental Study on Condensation Heat Transfer Characteristics and Pressure Drop of Plate Heat Exchangers using the Alternative Refrigerant R410A (대체 냉매 R410A를 적용한 판형열교환기의 응축열전달 특성 및 압력강하에 대한 실험적 연구)

  • Kim, Y.H.;Han, D.H.;Lee, K.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.220-225
    • /
    • 2001
  • The plate heat exchanger is characterized. by low pressure drop and high heat transfer coefficient. The experimental study has been performed on the condensation heat transfer and pressure drop characteristics of the plate heat exchangers in this study. In the present study, a brazed type plate heat exchanger was investigated at a chevron angle of $45^{\circ},\;55^{\circ},\;and\;70^{\circ}$ with R410A. Condensation temperatures were varied from $20^{\circ}C\;and\;30^{\circ}C$, and mass flux was ranged from $13{\sim}34\;kg/m^{2}s$ with constant heat flux ($=5\;kw/m^{2}$). The heat transfer coefficient and pressure drop increased with the chevron angle. Average condensation heat transfer coefficients and pressure drops are decreased with increasing condensation tempeature.

  • PDF

Experimental study on the performance of a brazed plate heat exchanger (용접식 판형 열교환기의 성능에 관한 실험적 연구)

  • Kim, Jong-Ha;Yun, Jae-Ho;Kwon, Oh-Kyung;Kim, Jong-Hun;Ryu, Hae-Sung;Lee, Chang-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.477-482
    • /
    • 2001
  • An experimental study on the performance evaluation of a brazed plate heat-exchanger with 10RT of normal cooling capacity has been carried out. In the present study, a brazed type plate heat exchanger was tested at a chevron angle $25^{\circ}$ with refrigerant R-22. Mass flux was ranged from $23\;to\;58kg/m^{2}s$ in condensation, and from $22\;to\;53kg/m^{2}s$ in evaporation. The heat transfer coefficient and pressure drop increased with the mass flux increases. The water side pressure drop increased with the cooling water flow rate and chilled water flow rate increases, while mass flux has little affect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

  • PDF

A NUMERICAL STUDY ON THE CHARACTERISTIC OF FLOW DISTRIBUTION IN THE CHANNEL OF PLATE HEAT EXCHANGER FOR VARIOUS NUMBER OF CHANNELS (판형 열교환기의 전열판 개수에 따른 유량 분배 특성에 대한 수치해석)

  • Lee, Na-Ri;Jung, Jae-Hyuk;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.129-134
    • /
    • 2009
  • In the present study, the characteristic of flow distribution in the channel of a plate heat exchanger is investigated numerically. In order to accomplish the efficient and fast analyses of the flow characteristics in the channel, a semi-microscopic analysis has been performed using a porous media model. For semi-microscopic analysis using porous media, the flow resistance coefficients are obtained through the result of pressure drop in the experimental data. The results showed that the variation of mass flow rate, geometry and chevron angle strongly depend on the flow distribution in the channel. Particularly, the chevron angle is most important factor for uniform flow distribution.

  • PDF

Avascular Necrosis of the First Metatarsal Head after Distal Chevron Osteotomy for Hallux Valgus (A Case Report) (무지 외반증에서 원위 갈매기형 절골술 후 발생한 제1 중족골 두 무혈성 괴사 (1예 보고))

  • Jeong, Un-Seob;Lee, Jung-Ho;Park, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.115-119
    • /
    • 2007
  • Avascular necrosis of the first metatarsal head is uncommon. It is most often seen following a distal metatarsal osteotomy for hallux valgus. Although many cases may be subclinical, it is a powerful cause of failure of bunion surgery. Avascular necrosis of the first metatarsal head results in a series of events that begins with phases of avascularity; revascularization, with or without collapse; and reossification. Collapse may result in degenerative change of the metatarsophalangeal joint. We have recently experienced a case of avascular necrosis of the first metatarsal head.

  • PDF

A study on the estimation of fracture toughness of granite by acoustic emission (미소 파괴음 빈도 측정에 의한 화강암의 파괴인성 평가에 관한 연구)

  • 신재근;이상은;임한욱
    • Tunnel and Underground Space
    • /
    • v.10 no.2
    • /
    • pp.227-236
    • /
    • 2000
  • The fracture toughness can be measured by the two testing methods using chevron-notched specimen according to the ISRM Working Group of Commission of Testing Methods. They are chevron bend (CB) test and short rod (SR) test. In this study, the suggested methods (Level I tests) were conducted on the CB and SR specimens of Chuncheon granite. In addition. the J-integral analysis was combined with an acoustic emission technique to determine the fracture toughness. The results from two telling methods were analyzed in terms of the anisotropy and the acoustic emission characteristics.

  • PDF

Study on Pressure Drop and Condensation Heat Transfer Characteristics of R-404A in Brazed Plate Heat Exchanger (R-404A를 사용한 용접형 판형 열교환기의 압력강하 및 응축 열전달특성에 관한 연구)

  • 권오갑;전창덕;강종식;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.174-183
    • /
    • 2001
  • Experimental study has been carried out on the characteristics of pressure drop and heat transfer of brazed plate heat exchangers using R-404A. Data are presented for the following range of variables: the mass flux ($20~80kg/m^2s$), chevron angle($20^{circ}C,\;35^{circ}C,\;45^{circ}C$) and inlet pressure of he refrigerant (1.4 and 1.6 MPa). for both subcooled and tow-phase flow, as chevron angle increases, pressure drop and heat transfer coefficient decrease. Condensation hat transfer coefficient and pressure drop was compared with the previously proposed correlations. Among them, Traviss correlation agreed with experimental results within -35~82% for heat transfer coefficient and -73~93% for pressure drop.

  • PDF