Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator (이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구)

  • Koo, Bon-Yeoul;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

A Study on the Chest Radiographic Condition in Adult. (흉부X-선(胸部X-線) 촬영조건(撮影條件)에 대(對)한 고찰(考察))

  • Lee, Sang-Suk;Youn, Chul-Ho;Joo, Kuang-Tai;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.31-35
    • /
    • 1979
  • A thorax is consisted of a heart, great vesseles, lungs, ribs, sternum and thoracic spine etc. The quality of chest radiogram is very important in order to find out abnormality in the lung field. The image has two major characteristics; density and contrast which directly influence the diagnostic quality of the roentgenogram. It is very hard to make excellent film image in the lung field because of overlapping bones and other soft tissues. To take a good radiogram of lung field, we studied the condition of chest P-A projection in adult and obtained results as follows: 1. The average chest radiographic condition is resulted as 62KVP, 16 mAs in hospitals around Kyung Ki-Do, Korea, 2. The density of the chest 20cm in thickness, is equal to the water phantom 8cm in thickness. 3. The best quality of chest radiogram is achieved in the condition of the lung field at 100KVP, 9.6mAs by use of Grid 8:1.

  • PDF

Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징)

  • Jeong, Hoi-Woun;Kim, Jung-Min;Jeong, Man-Hee;Im, Eun-Kyung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

A Study on High Kilovoltage Technique in taking Chest Radiogram. (흉부(胸部) 고관전압(高管電壓) 촬영조건(撮影條件)에 관(關)한 검토(檢討))

  • Kang, Hong-Seok;Kim, Chang-Kyun;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.37-43
    • /
    • 1979
  • High kilovoltage technique as compared with low kilovoltage in taking chest radiogram has much advantages. Authors performed an experiment by using acryl phantom to make the technical chart at 120KV and obtained the results as follows; 1. Increase and decrease of tube voltage in thickness change was 3.2KV per cm at variable technic chart. 2. At fixed kilovoltage technic chart, increase and decrease was $0.12{\sim}0.2$ mAs per cm in chest thickness. 3. Increase and decrease of distance was 1.3inches per cm in thicknese change

  • PDF

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

Prediction of Entrance Surface Dose in Chest Digital Radiography (흉부 디지털촬영에서 입사표면선량 예측)

  • Lee, Won-Jeong;Jeong, Sun-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.573-579
    • /
    • 2019
  • The purpose of this study is predicted easily the entrance surface dose (ESD) in chest digital radiography. We used two detector type such as flat-panel detector (FP) and IP (Imaging plate detector). ESD was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image. Dose-area product (DAP) or exposure index (EI) was checked by Digital Imaging and Communications in Medicine (DICOM) header on phantom images. Statistical analysis was performed by the linear regression using SPSS ver. 19.0. ESD was significant difference between FP and IP($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017). ESD was positively correlated with image quality in FP as well as IP. In FP, adjusted R square was 0.978 (97.8%) and linear regression model was $ESD=0.407+68.810{\times}DAP$. DAP was 4.781 by calculating the $DAP=0.021+0.014{\times}340{\mu}Gy$. In IP, adjusted R square was 0.645 (64.5%) and linear regression model was $ESD=-63.339+0.188{\times}EI$. EI was 1748.97 by calculating the $EI=565.431+3.481{\times}340{\mu}Gy$. In chest digital radiography, the ESD can be easily predicted by the DICOM header information.

Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning (흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과)

  • Lee, Jong-Seok;Kweon, Dae-Cheol;You, Beong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.225-231
    • /
    • 2009
  • The purpose of the current study was to compare radiation dose of 64MDCT performed with automatic exposure control (AEC) with manual selection fixed tube current. We evaluated the CT scans of phantom of the chest and abdomen using the fixed tube current and AEC technique. Objective image noise shown as the standard deviation of CT value in Hounsfield units was measured on the obtained images. Compared with fixed tube current, AEC resulted in reduction of the chest and abdomen in the CTDIvol (35.2%, 5.9%) and DLP (49.3%, 3.2%). Compared with manually selected fixed tube current, AEC resulted in reduced radiation dose at MDCT study of chest and abdomen.

A Study on Overexposure Rate according to Overdensity in Chest X-ray Radiography(II) (흉부촬영에서 overdensity에 따른 overexposure rate를 아는 방법(II))

  • Kim, Jung-Min;Huo, Joon;Hayashi, Taro
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • We have presented with the "A study on overexposure rate according to over-density in chest X-ray radiography(I)" last year. In this report, We could calculate the entrance skin dose from chest X-ray film density the formula $I_0=Ix/e^{-{\mu}x}{\times}mG$, (mG is Bucky factor) was used to deliver the skin dose. At that time, There was two problems that the Bucky factor from maker was not equal to field experience and the field size influenced on the Attenuation Rate. The experiment of Bucky factor was done from film method and retried the Attenuation Rate of Acryle phantom according to Good & Poor geometry. As the results, The Bucky factor from maker higher than in this experiments $30{\sim}40%$. The Attenuation Rate in good geometric condition brings about a little alteration compare with poor geometric condition. In the field experiment, we could get the chest image with very low entrance skin radiation dose $29.3{\mu}Sv$, especially with air gap methode, the entrance skin dose was detected $10{\mu}Sv$.