Medical Radiation Exposure in Children CT and Dose Reduction (소아 CT 촬영시 방사선 피폭과 저감화 방법)

  • Lee, Jeong-Keun;Jang, Seong-Joo;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.356-363
    • /
    • 2014
  • Recently pediatric CT has been performed by reduced dose according to tube current modulation이라고, this fact has a possibility more reduce a dose because of strong affect depend on tube current modulation. Almost all MDCT snow show and allow storage of the volume CT dose index (CTDIvol), dose length product (DLP), and effective dose estimations on dose reports, which are essential to assess patient radiation exposure and risks. To decrease these radiation exposure risks, the principles of justification and optimization should be followed. justification means that the examination must be medically indicated and useful. Results is using tube current modulation이라고 tend to the lower kV, the lower effective dose. In case of use a low dose CT protocol, we found a relatively lower effective dose than using tube current modulation. Average effective dose of our studies(brain, chest, abdomen-pelvis) less than 47%, 13.8%, 25.7% of germany reference dose, and 55.7%, 10.2%, 43.6% of UK(United Kingdom) reference dose respectively. when performed examination for reduced dose, we must use tube current modulation and low dose CT protocol including body-weight based tube current adaption.

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography (디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구)

  • Park, Han Sol;Kim, Myeong Seong;Jung, Hong-Moon;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

A Study for Reduction of Radiation Dose in the Field of Diagnostic Radiology - A Point of Tube Voltage and Filtration - (진단방사선 영역에서 피폭선량 감소를 위한 기술적 연구 - 관전압과 부가여과판을 중심으로 -)

  • Ha, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.89-97
    • /
    • 1992
  • X-ray quality is identified numerically by half value layer(H.V.L) and the HVL is affected by the kVp and the amount of filtration in the useful beam. X-ray quality evaluated by H.L.D is influenced by kVp and filtration. Author had several experiments with phantom in diameter of 8 cm normal adult chest, for reduction of radiation dose of the patients in diagnostic radiology and got some results. 1. H.V.L is increased the thicker the filter and the higher the kVp. 2. If the kVp is increased from 60 to 120, the skin dose can be reduced as 34%(Skin dose of 60 kVp with 4 mmAl filter : 100%). 3. If the 4 mmAl filter with 60 kVp is added to x-ray tube, skin dose can be reduced as 23% than no filter. 4. Therefore high kVp and filtration can increase output to input dose ratio and 120 kVp and 4 mmAl filter were most effective for reduction of patient dose in chest radiography.

  • PDF

Endobronchial Brachytherapy for Malignant Airway Obstruction: Low Dose Rate Versus High Dose Rate (악성 종양에 의한 기도폐쇄시 내기관지 근접치료 : 저선량 치료 대 고선량 치료의 비교)

  • Cho, Young-Kap
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.123-128
    • /
    • 1996
  • Purpose : This is a retrospective study to compare the Palliation rates, survival rates and complications of low dose rate and high dose rate endobronchial brachytherapy in the management of malignant airway obstruction. Materials and methods : Forty three consecutive patients with malignant airway compromise from primary or metastatic lung tumors were treated with low dose rate(LDR) endobronchial Iridium-192 insertion(21 patients) between October 1988 and June 1992, and high dose rate(HDR) endobronchial brachytherapy(22 patients) between August 1992 and April 1994 with palliative aim Flexible fiberoptic bronchoscopy under fluoroscopic control was utilized in all 91 procedures. Twenty seven LDR Procedures delivered a dose of 5-7.5 Gy to a 1.0 cm radius respectively. Results : Subjective and objective responses to treatments were evaluated on follow-up examinations by clinical examination, chest x-rays and CT scan of the chest on some patients. Fifteen of 21 LDR patients and 19 of 22 HDR Patients showed subjective improvement in terms of better breathing and less Productive cough as well as complete disappearance of hemoptysis. Objective improvement on chest x-rays and CT scan of the chest had been demonstrated on 8 LDR Patients and 10 HDR patients. Conclusion : The technique of LDR and HDR endobronchial brachytherapy is simple and well tolerated procedure with minimal morbidity It Provides excellent palliation by keeping airway Patent in these short life-spanned patients.

  • PDF

Development and Radiation Shield effects of Dose Reduction Fiber for Scatter ray in CT Exams (피폭선량저감 섬유의 개발과 CT 검사시 산란선 차폐 효과)

  • Kim, Sunghwan;Kim, Yong Jin;Kwak, Jong Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1871-1876
    • /
    • 2013
  • In this study, we developed and characterized the shielding properties of dose reduction fiber (DRF, Buffalo Co.) sheet during brain and chest CT examinations. The DRF sheet was composed of $1{\sim}500{\mu}m$ oxide Bismuth ($Bi_2O_3$) and 5 ~ 50 nm nano-barium sulfate ($BaSO_4$). Phantom and clinical studies were performed for characterization of the DRF shielding properties. In clinical study, we measured doses of eye, chest, abdomen and reproductive system of 60 patients in 3 hospitals during brain and chest CT examinations. We could determined the shielding effect of the DRF by comparing the doses when we used the DRF sheet or not. When we used the sheet during CT examination, the scattered dose were reduced about 20~50%. So, we suggest that the fiber should be used in radiological examinations for reducing patients doses.

Assessment of Entrance Surface Dose and Image Distortion in Accordance with Abdominal Obesity in the Chest Radiography (흉부 X-선 검사에서 복부비만에 따른 입사표면선량과 영상 왜곡도 평가)

  • Kim, Boo Soon;Park, Jeong Kyu;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.473-478
    • /
    • 2015
  • Abdominal obesity is one of the most influential index to predict of insulin resistance syndrome/metabolic syndrome in social demographic characteristics. It is matter of fact that radiation dose are increasing with development of medical treatment and device. In this study, we estimated distortion between reference image and entrance surface dose when take a chest radiography forward chest phantom assumed abdominal obesity. When angle of chest phantom incline $5^{\circ}$ forward, thoracic transverse and longitudinal diameter increase 1.22% and 0.44% each. Also cardiac transverse diameter increase 1.01% and cardio-throracic ratio (CTR) decrease 0.27% in the same situation of incline to $5^{\circ}$ forward. Thoracic transverse diameter shows the largest increase, and CTR was decreased. But entrance surface dose to phantom increase significantly 6.12% when angle of chest phantom incline $5^{\circ}$ forward. In conclusion, we have to pay attention to accurate positioning, to prevent a distortion of image through incline, and make patients not to expose to additional radiation.

Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.

Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea

  • Jae-Yeon Hwang;Young Hun Choi;Hee Mang Yoon;Young Jin Ryu;Hyun Joo Shin;Hyun Gi Kim;So Mi Lee;Sun Kyung You;Ji Eun Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1172-1184
    • /
    • 2021
  • Objective: The purposes of this study were to analyze the radiation doses for pediatric abdominopelvic and chest CT examinations from university hospitals in Korea and to establish the local diagnostic reference levels (DRLs) based on the body weight and size. Materials and Methods: At seven university hospitals in Korea, 2494 CT examinations of patients aged 15 years or younger (1625 abdominopelvic and 869 chest CT examinations) between January and December 2017 were analyzed in this study. CT scans were transferred to commercial automated dose management software for the analysis after being de-identified. DRLs were calculated after grouping the patients according to the body weight and effective diameter. DRLs were set at the 75th percentile of the distribution of each institution's typical values. Results: For body weights of 5, 15, 30, 50, and 80 kg, DRLs (volume CT dose index [CTDIvol]) were 1.4, 2.2, 2.7, 4.0, and 4.7 mGy, respectively, for abdominopelvic CT and 1.2, 1.5, 2.3, 3.7, and 5.8 mGy, respectively, for chest CT. For effective diameters of < 13 cm, 14-16 cm, 17-20 cm, 21-24 cm, and > 24 cm, DRLs (size-specific dose estimates [SSDE]) were 4.1, 5.0, 5.7, 7.1, and 7.2 mGy, respectively, for abdominopelvic CT and 2.8, 4.6, 4.3, 5.3, and 7.5 mGy, respectively, for chest CT. SSDE was greater than CTDIvol in all age groups. Overall, the local DRL was lower than DRLs in previously conducted dose surveys and other countries. Conclusion: Our study set local DRLs in pediatric abdominopelvic and chest CT examinations for the body weight and size. Further research involving more facilities and CT examinations is required to develop national DRLs and update the current DRLs.