• 제목/요약/키워드: Chest CT Image

검색결과 110건 처리시간 0.022초

Evaluation of Adult Lung CT Image for Ultra-Low-Dose CT Using Deep Learning Based Reconstruction

  • JO, Jun-Ho;MIN, Hyo-June;JEON, Kwang-Ho;KIM, Yu-Jin;LEE, Sang-Hyeok;KIM, Mi-Sung;JEON, Pil-Hyun;KIM, Daehong;BAEK, Cheol-Ha;LEE, Hakjae
    • 한국인공지능학회지
    • /
    • 제9권2호
    • /
    • pp.1-5
    • /
    • 2021
  • Although CT has an advantage in describing the three-dimensional anatomical structure of the human body, it also has a disadvantage in that high doses are exposed to the patient. Recently, a deep learning-based image reconstruction method has been used to reduce patient dose. The purpose of this study is to analyze the dose reduction and image quality improvement of deep learning-based reconstruction (DLR) on the adult's chest CT examination. Adult lung phantom was used for image acquisition and analysis. Lung phantom was scanned at ultra-low-dose (ULD), low-dose (LD), and standard dose (SD) modes, and images were reconstructed using FBP (Filtered back projection), IR (Iterative reconstruction), DLR (Deep learning reconstruction) algorithms. Image quality variations with respect to varying imaging doses were evaluated using noise and SNR. At ULD mode, the noise of the DLR image was reduced by 62.42% compared to the FBP image, and at SD mode, the SNR of the DLR image was increased by 159.60% compared to the SNR of the FBP image. Based on this study, it is anticipated that the DLR will not only substantially reduce the chest CT dose but also drastic improvement of the image quality.

흉부 CT 검사에서 3차원 체적 영상의 정량적 분석 (Quantitative analysis of three dimensional volumetric images in Chest CT)

  • 장현철;조재환;박철수
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.255-260
    • /
    • 2011
  • 본 연구는 흉부 CT 검사 시 늑골 골절 환자를 대상으로 3차원 체적 재구성 기법의 유용성에 대해 알아보고자 하였다. 임상에서 주로 이용 하는 재구성기법인 다평면재구성(MPR), 3차원 체적 영상 기법(VRT)을 적용하여 영상데이터를 각 각 정량적 방법과 정성적 방법으로 비교 분석하였다. 재구성 영상의 분석 및 평가결과 늑골 골절 환자의 흉부 CT 검사 시 조영 전 원 자료를 이용하여 3차원 체적영상으로 재구성 하는 것이 보다 더 인공 음영을 최소화 시켰으며, 늑골 골절 판단 및 3차원 체적 영상 재구성 소요시간이 단축 됨을 알 수 있었다.

유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교 (Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry)

  • 박태석;한준희;조승연;이은임;조규원;권대철
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

개선된 가변형 능동모델을 이용한 흉부 컴퓨터단층영상에서 폐 실질의 분할 (Image Segmentation of Lung Parenchyma using Improved Deformable Model on Chest Computed Tomography)

  • 김창수;최석윤
    • 한국정보통신학회논문지
    • /
    • 제13권10호
    • /
    • pp.2163-2170
    • /
    • 2009
  • 흉부 컴퓨터단층영상에서의 얻어진 폐 영상은 볼륨과 형태 등의 정량적인 정보들로서 진단과 수술 계획 등에 있어서 필연적 정보를 제공한다. 일반적인 영상분할은 이미지를 구성 요소영역이나 목적물에 따라 나누는 방법이다. 그러나 재분할을 하는 단계에서 최종영상은 에너지 최소화를 해결하는 정도에 의존하며, 분할은 응용대상의 관심 영역에서 객체나 물체의 경계에서 정지하게 된다. 가변형 능동모델은 컴퓨터 비젼, 영상처리 분야에서 광범위하게 사용되고 있다. 또한 영역 분할은 현재까지 많은 연구가 되고 있으며, Xu에 의해서 GVF라는 새로운 형태의 외부힘이 제안되고 있다. 본 논문에서 제안하는 알고리듬은 흉부 컴퓨터단층영상에서 실질을 자동 분할하기 위해서 에너지 최소화 방법을 사용하고, 영역분할을 위해 개선된 가변형 능동모델을 제안한다. 알고리듬은 정확한 영역분할을 위해서 기존 방법과 다른 개선된 외부힘을 정의하는 것이다. 임상의 실험은 흉부 컴퓨터단층영상에서 진단에 필요로 하는 폐 실질의 분할이 성공적인 결과를 나타내었다.

관상동맥 석회화 평가에서 저선량 흉부 CT와 관상동맥 석회화검사의 일치도 (Low-dose Chest CT in Evaluation of Coronary Artery Calcification: Correlation with Coronary Artery Calcium Score CT)

  • 김연민
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1033-1039
    • /
    • 2023
  • 폐 스크리닝 검사로 이용되고 있는 저선량 흉부 CT는 Scan 범위 내에 관상동맥 석회화에 대한 정보도 함께 포함하고 있어 이를 이용한 관상동맥 석회화 판별의 유용성을 알아보고자 한다. 저선량 흉부 CT 검사와 관상동맥 석회화 점수(CACS) 검사를 같은 날 시행 받은 자들을 대상으로 하였다. 관상동맥 석회화 점수 검사 결과를 Coronary artery calcium score categories and risks 분류법을 참고하여 4개 그룹(Low: 1〈CACS〈10, Mild: 10〈CACS〈100, Moderate: 100〈CACS〈400, High: 400〈CACS)으로 각각 30명을 선정한 후 관상동맥 석회화 수치 측정 업무에 종사하고 있는 경력 15년차 이상 5명의 방사선사가 저선량 흉부 CT 영상에서 관상동맥 석회화 유무를 후향적으로 분석하였다. 저선량 흉부 CT 영상에서 5명의 관찰자가 통일되게 판독한 결과가 관상동맥 석회화점수 CT 검사 결과와 일치한 경우는 Low 그룹: 56%, Mild 그룹: 96.6%, Moderate 그룹: 100%, High 그룹: 100%로 나타났다. Low 그룹에서 5명의 관찰자 모두가 석회화를 관찰한 것은 30건 중 17건이었으며, 5명이 모두 판별 불가로 결정한 경우 7건이었다. 무증상 성인을 대상으로 저선량 흉부 CT 검사에서 석회화 점수가 15 이상인 경우에는 관상동맥 석회화를 100% 관찰할 수 있었다. 판별이 가능한 최소 석회화 수치는 1로, 피검자의 체형이 작거나 심장의 움직임이 최소가 되는 시점에서 스캔이 이루어지는 경우 매우 작은 석회화까지도 판별할 수 있다는 것을 알 수 있었다.

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

적응 양자화를 위한 의료 영상 정보의 변환 부호화에 관한 연구 (A Study Transform Coding of Medical Image Using Adaptive Quantization Method)

  • 한영오;박장춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.243-252
    • /
    • 1989
  • In this study, medical images, which are X-ray image and CT image, are compressed by the adam live coding technique. The medical images may be treated as special ones, because they are different from general images in many respects. The statistical characteristics that medical images only have in transform domain are analyzed, and then the improved quantization method is proposed for medical images. For chest X-ray image and CT head image, the better results are obtained by the improved adaptive coding technique.

  • PDF

영역 이진화 모델링과 지역적 변형 모델을 이용한 시간차 흉부 CT 영상의 폐 실질 비강체 정합 기법 (Non-rigid Registration Method of Lung Parenchyma in Temporal Chest CT Scans using Region Binarization Modeling and Locally Deformable Model)

  • 계희원;이정진
    • 한국멀티미디어학회논문지
    • /
    • 제16권6호
    • /
    • pp.700-707
    • /
    • 2013
  • 본 논문에서는 시간차 흉부 CT 영상의 폐 실질 비강체 정합을 위하여 영역 이진화 모델링과 지역적 변형 모델을 이용한 정합 기법을 제안한다. 제안 기법은 먼저 폐 혈관과 실질을 분할하고, 영역 이진화 모델링을 수행하여 두 영상 사이의 밝기값의 차이에 따른 정합 오차를 최소화 한다. 다음으로 초기 정합 기법으로 두 폐 표면을 전역적으로 정렬하고, 지역적 변형 변환 모델을 제안하여 비강체 정합을 수행한다. 또한, 정합 후 감산된 시간에 따른 밝기값 차이가 미리 정의된 칼라 맵을 이용하여 가시화 된다. 실험 결과는 제안기법이 10명의 환자에 대하여 최대호흡과 최소호흡 CT 영상에서 폐 실질을 정확하게 정합하였음을 보여주었다. 제안된 비강체 정합 기법은 폐 실질에 대한 정량적 분석 결과의 직관적인 칼라 매핑을 통하여 다양한 폐 질환의 정량적 분석에 유용하게 사용될 수 있다.

소아 흉부 CT 검사 시 딥러닝 영상 재구성의 유용성 (Usefulness of Deep Learning Image Reconstruction in Pediatric Chest CT)

  • 김도훈;이효영
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.297-303
    • /
    • 2023
  • 소아 전산화단층촬영(Computed Tomography, CT) 검사 시 어린 환자들의 협조가 어려워 검사 실패나 재검사가 빈번히 발생할 수 있다. 딥러닝 이미지 재구성(Deep Learning Image Reconstruction, DLIR) 방법은 방사선 감수성이 높은 소아 환자들의 CT 검사에서 재검사율을 낮추면서 진단적 가치가 높은 영상을 획득할 수 있다. 본 연구에서는 DLIR을 적용하여 소아 흉부 CT 검사에서 호흡이나 움직임으로 인한 노이즈를 줄이고 임상적으로 유용한 영상을 얻기 위한 가능성을 조사하였다. 경상남도 소재의 P병원에서 7세 미만의 소아 43명의 흉부 CT 검사 데이터를 후향적으로 분석하였으며, 필터링 역 투영 재구성법(Filtered Back Projection, FBP), 반복적 재구성법(Adaptive Statistical Iterative Reconstruction, ASIR-50), 딥러닝 알고리즘인 True Fidelity-Middle(TF-M)의 영상을 비교하였다. 조영 증강된 흉부 영상 중 오른쪽 상행 대동맥(Ascending Aorta, AA)과 등 근육(Back Muscle, BM)에 동일한 ROI를 그리고 각 영상에서 HU값을 이용하여 노이즈(Standard deviation, SD)를 측정하였다. 통계분석은 SPSS(ver. 22.0)를 사용하여 세 측정치의 평균값을 일원 배치 분산분석(One-way ANOVA)으로 분석하였다. 연구의 결과로 AA의 SD값은 FBP=25.65±3.75, ASIR-50=19.08±3.93, TF-M=17.05±4.45 로 나타났으며(F=66.72, p=0.00), BM의 SD값은 FBP=26.64±3.81, ASIR-50=19.19±3.37, TF-M=19.87±4.25 로 나타났다(F=49.54, p=0.00). 사후검정의 결과는 세 그룹간 유의한 차이가 있었다. DLIR 재구성 방법은 기존의 재구성 방법과 비교하여 유의하게 낮은 노이즈 값을 보였다. 따라서 딥러닝 알고리즘인 TrueFidelity-Middle(TF-M)의 적용은 소아 흉부 CT 검사 시 호흡이나 움직임에 의한 영상 화질의 저하를 줄일 수 있어 임상적으로 매우 유용하게 활용될 것으로 기대된다.

흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구 (Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan)

  • 김현주;조재환;박철수
    • Journal of Radiation Protection and Research
    • /
    • 제35권4호
    • /
    • pp.135-141
    • /
    • 2010
  • 목적 : 추적검사를 위해 흉부질환을 주소로 내원한 CT 검사자를 대상으로 CT 파라미터 중 관전압의 변화에 따른 CT value의 변화와 화질평가, 피폭선량의 변화를 실험을 통하여 알아보고자 하였다. 대상 및 방법 : 장비는 Somatom Sensation 16 (Siemens, Erlangen, Germany)을 이용하였으며 관전압의 변화에 따른 CT value 측정은 100 kVp를 이용한 동맥기 영상에서 갑상선, 대동맥궁과 우폐동맥의 높이에 위치한 관심영역에 직경 1cm의 관심부위를 설정하여 3회씩 측정한 후 평균치를 기록하였다. 실험을 위하여 자체 제작한 팬텀(시험관)의 CT value 측정은 시험관에 조영제를 생리식염수에 여러 가지 비율로 희석하여 관전압 80 kVp, 100 kVp, 120 kVp, 140 kVp로 스캔하여 팬텀 영상의 중심부에서 CT value를 총 3회에 걸쳐 구한 후 평균값을 기록하였다. 피폭선량 분석에서는 관전류를 100 mAs로 고정하여 가장 최근에 시행한 120 kVp 동맥기 영상과 본 연구에서 설정한 100 kVp 동맥기영상에서의 CTDIVOL 값을 비교, 분석하였다. 흉부 영상의 화질평가는 관찰자 2명이 5단계로(Unacceptable, Suboptimal, Adequate, Good, Excellent diagnostic quality)구분하여 평가하였다. 결과 : 흉부영상의 CT value는 각 관심부위 별로 120 kVp 보다 100 kVp에서 14.06%~27.26%까지 증가하였다. 팬텀의 CT value 측정 결과 여러 종류의 조영제 농도에서 관전압이 낮아질수록 CT value 가 증가하였다. 피폭선량 분석에서 CTDIVOL 값은 관전압 100 kVp(5.00 mGy) 일때 120 kVp(7.80 mGy) 보다 약 36%가 감소하였다. 영상의 화질평가는 총 20명의 영상 중 Unacceptable 0명, Suboptimal 1명, Adequate 3명, Good 10명, Excellent 6명으로 평가되었다. 결론 : 반복적으로 CT 검사를 위해 내원한 검사자를 대상으로 저 관전압을 적용한 흉부 CT검사 시 영상의 질적 저하없이 진단 가치가 있는 영상의 획득과 피폭선량 감소효과를 얻을 수 있다고 사료된다.