• 제목/요약/키워드: Chest CT

검색결과 975건 처리시간 0.035초

흉부 CT에 있어서 컴퓨터 보조 진단 (Computer-Aided Diagnosis in Chest CT)

  • 구진모
    • Tuberculosis and Respiratory Diseases
    • /
    • 제57권6호
    • /
    • pp.515-521
    • /
    • 2004
  • With the increasing resolution of modern CT scanners, analysis of the larger numbers of images acquired in a lung screening exam or diagnostic study is necessary, which also needs high accuracy and reproducibility. Recent developments in the computerized analysis of medical images are expected to aid radiologists and other healthcare professional in various diagnostic tasks of medical image interpretation. This article is to provide a brief overview of some of computer-aided diagnosis schemes in chest CT.

치료된 폐농양환자의 폐실질 병변의 분석 (Analysis of Lung Parenchymal Sequelae Following Treatment for Lung Abscess)

  • 이지연;구소미;박경아;서유리;김세훈;김양기;김기업;황정화;어수택
    • Tuberculosis and Respiratory Diseases
    • /
    • 제71권6호
    • /
    • pp.438-444
    • /
    • 2011
  • Background: Lung abscess is necrosis of the pulmonary parenchyma caused by microbial infection. At present, clinical outcomes after treatment are good. However, the pulmonary parenchymal changes on the chest computed tomography (CT) after treatment are not well known. We studied the changes of pulmonary parenchyma on plane chest radiography and chest CT in patients with lung abscess following the administration of antibiotics. Methods: We retrospectively reviewed 39 patients who had lung abscess with or without combined pneumonia from January 2006 to July 2010. We studied the therapeutic response in plane chest radiography of them at 1, 2, or more than 3 months following treatment. If any chest CT of them during the study period, we reviewed. Results: Mean age of the patients was about $61.3{\pm}11.2$. Mean duration of antibiotics administration was about $36.7{\pm}26.8$ days. After 3 months of following plane chest radiography, 10 patients (36%) showed without residual sequelae among 28 patients. Findings from other patients showed decrease in densities (11 patients, 39%), fibrostreaky sequelae (4 patients, 14%) and bullae (3 patients, 10%). After more than 2 months, chest CT was checked only in 7 patients. Among the 7 patients, 4 patients showed no residual lesion, 3 patients showed decreased densities on plane chest radiography. Chest CT revealed fibrostreaky densities in 2 patients, ground glass opacities in 3 patients, bullous formation in 1 patient, and cystic bronchiectasis in 1 patient. Conclusion: After more than 2 months following treatment for lung abscess even though there were no lesions on plane chest radiography, chest CT showed fibrostreaky or ground glass opacity.

흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과 (Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning)

  • 이종석;권대철;유병규
    • 한국콘텐츠학회논문지
    • /
    • 제9권3호
    • /
    • pp.225-231
    • /
    • 2009
  • CT검사에 따른 방사선 선량의 유해성에 대한 관심이 고조되고 있어, 고정관전류기법과 AEC(automatic exposure control)를 적용하여 선량의 감소 효과를 비교하였다. 64MDCT를 이용하여 인체조직등가물질 팬텀으로 흉부 및 복부 부위를 고정관전류기법과 AEC를 적용하여 CTDIvol과 DLP를 비교하였고, 영상의 평가는 관심영역으로 CT감약계수와 노이즈를 측정하여 비교하였다. 흉부에서 고정관전류기법과 AEC적용에 따른 선량감소 효과는 CTDIvol 35.2%, DLP 49.3%, 복부에서는 CTDIvol 5.9%, DLP 3.2% 감소 효과가 있었다. CT검사에서 자동노출장치인 AEC를 이용하여 선량의 감소효과가 있다. CT 검사에 따른 환자의 피폭선량을 줄이기 위해서는 AEC를 이용하여야 한다.

식도 이물 모델에서 이물 탐색을 위한 삼차원 재구성법의 활용 (Detection of Foreign Body in Esophageal Foreign Body Model Using Three Dimensional Reconstruction Technique)

  • 우국성;유영삼;김동원
    • 대한기관식도과학회지
    • /
    • 제18권1호
    • /
    • pp.13-18
    • /
    • 2012
  • Objective This study was conducted to gather basic information of 3D CT in detecting and gaining information of esophageal foreign body (FB) models. Materials and Methods The chest model was made using PVC bottle, rubber balloon and plaster. Fish bone, Persimmon stone were used to mimic foreign bodies of esophageal model. The foreign body models were inserted into the balloon removing air from it and the balloon was sealed. The esophageal FB model was inserted into the chest model. The remaining space in the chest model was filled with fish paste and water to simulate soft tissue around esophagus. CT of chest model was reconstructed three-dimensionally by Rapidia software to make images of foreign body models. The axial CT, MPR image and VOI image were compared with real foreign body materials as to shape, size, location and orientation. Results Esophageal FB models were easily made. CT data gave good 3D images and showed realistic foreign body materials. Conclusion The results indicate the usefulness of 3D CT technique to help in diagnosis of esophageal foreign body models.

  • PDF

MDCT 검사에서 환자 체중을 이용한 선량 평가 (Estimate of Radiation Doses in MDCT Using Patient Weight)

  • 권성욱;동경래;권대철;구은회;최지원;정운관
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.246-252
    • /
    • 2010
  • 환자가 두부, 흉부, 복부 MDCT 검사에서 피폭되는 선량을 평가하였다. 선량의 지표는 CTDIvol, DLP, 유효선량을 평가하여 환자의 체중과 선량과의 상관관계를 분석하였다. CT 검사에서 검사 조건을 동일하게 하여 연속적으로 두부(520명), 흉부(531명), 복부(724명) 환자를 대상으로 하였다. CTDIvol과 DLP 평균선량은 두부검사에서 CTDIvol (48.6 mGy), DLP (1,604 $mGy{\cdot}cm$), 흉부검사에서 CTDIvol (6.9 mGy), DLP (250 $mGy{\cdot}cm$), 복부는 CTDIvol (10.5 mGy), DLP (575 $mGy{\cdot}cm$), 유효선량은 두부, 흉부, 복부에서 3.6, 4.2, 8.6 mSv로 분석되었다. 환자의 체중과 선량과의 상관분석에서 두부, 흉부, 복부에서, 두부는 상관관계가가 보이지 않았고, 흉부는 CTDIvol ($r^2$=0.62), DLP ($r^2$=0.694), 복부는 CTDIvol ($r^2$=0.691), DLP ($r^2$=0.741)와 양의 상관관계를 나타내냈다. 검사에 따른 체중과의 상관관계를 이해하고 검사 하면 방사선 피폭에 의한 선량을 평가하고 관리하는데 기여 할 수 있을 것이다.

A Modified Length-Based Grading Method for Assessing Coronary Artery Calcium Severity on Non-Electrocardiogram-Gated Chest Computed Tomography: A Multiple-Observer Study

  • Suh Young Kim;Young Joo Suh;Na Young Kim;Suji Lee;Kyungsun Nam;Jeongyun Kim;Hwan Kim;Hyunji Lee;Kyunghwa Han;Hwan Seok Yong
    • Korean Journal of Radiology
    • /
    • 제24권4호
    • /
    • pp.284-293
    • /
    • 2023
  • Objective: To validate a simplified ordinal scoring method, referred to as modified length-based grading, for assessing coronary artery calcium (CAC) severity on non-electrocardiogram (ECG)-gated chest computed tomography (CT). Materials and Methods: This retrospective study enrolled 120 patients (mean age ± standard deviation [SD], 63.1 ± 14.5 years; male, 64) who underwent both non-ECG-gated chest CT and ECG-gated cardiac CT between January 2011 and December 2021. Six radiologists independently assessed CAC severity on chest CT using two scoring methods (visual assessment and modified length-based grading) and categorized the results as none, mild, moderate, or severe. The CAC category on cardiac CT assessed using the Agatston score was used as the reference standard. Agreement among the six observers for CAC category classification was assessed using Fleiss kappa statistics. Agreement between CAC categories on chest CT obtained using either method and the Agatston score categories on cardiac CT was assessed using Cohen's kappa. The time taken to evaluate CAC grading was compared between the observers and two grading methods. Results: For differentiation of the four CAC categories, interobserver agreement was moderate for visual assessment (Fleiss kappa, 0.553 [95% confidence interval {CI}: 0.496-0.610]) and good for modified length-based grading (Fleiss kappa, 0.695 [95% CI: 0.636-0.754]). The modified length-based grading demonstrated better agreement with the reference standard categorization with cardiac CT than visual assessment (Cohen's kappa, 0.565 [95% CI: 0.511-0.619 for visual assessment vs. 0.695 [95% CI: 0.638-0.752] for modified length-based grading). The overall time for evaluating CAC grading was slightly shorter in visual assessment (mean ± SD, 41.8 ± 38.9 s) than in modified length-based grading (43.5 ± 33.2 s) (P < 0.001). Conclusion: The modified length-based grading worked well for evaluating CAC on non-ECG-gated chest CT with better interobserver agreement and agreement with cardiac CT than visual assessment.

비 조영증강 흉부 CT에서 관상동맥 칼슘스코어 측정을 위한 16 cm 축상 촬영 기법의 유용성: 전향적 탐색적 연구 (Utility of the 16-cm Axial Volume Scan Technique for Coronary Artery Calcium Scoring on Non-Enhanced Chest CT: A Prospective Pilot Study)

  • 기소정;박철환;한경화;신재민;김지영;김태훈
    • 대한영상의학회지
    • /
    • 제82권6호
    • /
    • pp.1493-1504
    • /
    • 2021
  • 목적 관상동맥 칼슘스코어(coronary artery calcium score; 이하 CACS)를 측정하는 데 있어 비 조영증강 흉부 CT에서 16 cm 축상 촬영 기법의 유용성을 알아보고자 하였다. 대상과 방법 20명의 환자를 대상으로 16 cm 축상 촬영 기법을 이용한 비 조영증강 흉부 CT와 칼슘 스코어 CT를 전향적으로 시행하였다. 흉부 CT는 세 가지 절편 두께(0.625, 1.25, 2.5 mm)로 재구성하여, Agatston 방법을 통해 관상동맥 칼슘스코어를 측정하였다. 다양한 절편 두께의 비 조영증강 흉부 CT와 칼슘스코어 CT의 관상동맥 칼슘스코어를 비교하고, 단면 분석을 통해 CACS의 임상적 중요성에 대한 일치를 확인하였다. 또한 각각의 석회화 병변들을 위치와 크기로 나누어 비 조영증강 흉부 CT와 칼슘스코어 CT에서 일대일 비교를 시행하였다. 결과 2.5, 1.25, 0.625 mm 절편 두께의 흉부 CT와 칼슘스코어 CT의 CACS 상관 계수는 각각 0.9850, 0.9688, 0.9834였다. 흉부 CT와 칼슘스코어 CT 간의 CACS 차이는 0.625 mm에서 -21.4%, 1.25 mm에서 -39.4%, 2.5 mm 절편 두께에서 -76.2%였다. CACS 구간별 분석에서 절편 두께별로 16명(80%, 0.625 mm), 16명(80%, 1.25 mm), 13명(65%, 2.5 mm)의 환자가 관상 동맥 질환의 위험도 구간이 일치하였다. 관찰자 간 일치도는 모든 절편 간격에서 높게 나타났다. 세 절편 두께 중에서는 0.625 mm CT에서 석회화 병변에 대한 민감도가 가장 높았다. 결론 16 cm 축상 촬영 기법을 이용한 비 조영증강 흉부 CT에서 electrocardiogram 동기화 없이도, 0.625 mm 절편 간격에서 칼슘스코어 CT에서의 CACS와의 유사한 값을 얻을 수 있었다. 이를 통해 추가 방사선 노출 없이, 심혈관 질환 위험을 예측하는 데 도움이 될 수 있다.

식도암의 병기 결정에 있어 흉부 CT의 유용성 (The Utility of Chest CT in Staging of Esophageal Cancer)

  • 홍성범;장원채;김윤현;김병표;최용선;오봉석
    • Journal of Chest Surgery
    • /
    • 제37권12호
    • /
    • pp.992-998
    • /
    • 2004
  • 배경 및 목적: 식도암의 병기 결정은 병변의 절제 가능성 여부를 결정하고 환자의 예후를 예측하는 데 지대한 영향을 미친다. 흉부 전산화 단층 촬영(Computerized Tomography, CT)은 식도암의 병기 결정을 위해 현재까지 가장 널리 사용되고 있는 진단 방법 중의 하나이지만, 다양한 위양성 및 위음성 소견에 의해 제한점들이 보고되고 있다. 이에 본 저자는 수술 전 식도암의 병기 결정에 있어서 흉부 CT의 유용성에 대해 연구하고자 하였다. 대상 및 방법: 1999년 1월부터 2003년 6월까지 식도 편평 상피 세포 암으로 진단받고 수술을 시행한 환자 114예를 대상으로 수술 전 CT에 의한 병기와 수술 후 조직 소견에 의한 병기를 후향적으로 비교 분석하였다. CT 진단에 의한 주변 조직 침습, 림프절 침범, 그리고 원위부 전이 여부 등을 관찰하고, 이를 수술 후 조직 병리 소견과 비교함으로써, 이들의 진단에 대한 CT의 민감도(Sensitivity), 특이도(Specificity), 정확도(Accuracy) 및 일치도(Reproducibility)를 구하였다. 일치도는 Z-test를 시행하여 통계적 유의성을 평가하였다. 결과: 식도암의 CT에 의한 병기와 조직 병리 소견에 의한 병기의 일치도는 원발성 종양의 국소 침윤의 경우 0.32 (p<0.01), 림프절 전이에 대하여는 0.36 (p<0.01)이었으며, 원위부 장기에 대한 전이 여부에 대하여는 0.62 (p<0.01)이었다. 림프절 전이나 원거리 전이에 대한 CT와 조직 병리 소견의 일치도는 종양의 국소 침윤에 대한 일치도보다 우수하였다. 원발성 종양의 주변 장기 침습에 대한 CT의 정확도는 71군(78.9%)과 72군 (62.3%)에 비해 73군(65.8%)과 74군(98.2%)에서 우수하였다. 또한 식도암의 국소 종양 침윤에 대한 CT진단은 각 병기별로 민감도에 비해 특이도가 높았다. 결론: 식도암의 병기 결정에 있어 CT진단은 종양에 의한 식도 벽의 침습 정도를 파악하는 것보다 주위 조직이나 장기, 그리고 림프절의 전이를 파악하는데 더 유용함을 알 수 있었다.

Evolution of Interferon-Gamma Release Assay Results and Submillisievert Chest CT Findings among Close Contacts of Active Pulmonary Tuberculosis Patients

  • Yoon, Soonho;Mihn, Do-CiC;Song, Jin-Wha;Kim, Sung A;Yim, Jae-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권4호
    • /
    • pp.283-288
    • /
    • 2020
  • Background: Latent tuberculosis (TB) infection among TB contacts is diagnosed using plain chest radiography and interferon-gamma release assays (IGRAs). However, plain chest radiographs often miss active TB, and the results of IGRA could fluctuate over time. The purpose of this study was to elucidate changes in the results of the serial IGRAs and in the findings of the serial submillisievert chest computed tomography (CT) scans among the close contacts of active pulmonary TB patients. Methods: Patients age 20 or older with active pulmonary TB and their close contacts were invited to participate in this study. Two types of IGRA (QuantiFERON-TB Gold In-Tube assay [QFT-GIT] and the T-SPOT.TB test [T-SPOT]) and submillisievert chest CT scanning were performed at baseline and at 3 and 12 months after enrollment. Results: In total, 19 close contacts participated in this study. One was diagnosed with active pulmonary TB and was excluded from further analysis. At baseline, four of 18 contacts (22.2%) showed positive results for QFT-GIT and T-SPOT; there were no discordant results. During the follow-up, transient and permanent positive or negative conversions and discordant results between the two types of IGRAs were observed in some patients. Among the 17 contacts who underwent submillisievert chest CT scanning, calcified nodules were identified in seven (41.2%), noncalcified nodules in 14 (82.4%), and bronchiectasis in four (23.5%). Some nodules disappeared over time. Conclusion: The results of the QFT-GIT and T-SPOT assays and the CT images may change during 1 year of observation of close contacts of the active TB patients.

흉부 저선량 및 복부 비조영 CT 검사에서 환자 및 장비 인자와 선량과의 상관관계 분석 (Correlation Analysis of between Patient and Equipment Factors and Radiation Dose in Chest Low Dose and Abdominal Non-contrast CT)

  • 심지나;이영진
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.117-123
    • /
    • 2021
  • 본 논문에서는 흉부 저선량 CT와 복부 비조영 CT에서 선량기록을 바탕으로 환자선량에 영향을 줄 수 있는 요인과 상관관계를 확인하여 실질적인 선량 감소 방안의 근거를 마련하고자 하였다. 흉부 저선량 CT와 복부 비조영 CT 검사 시 불필요하게 피폭이 발생하는 원인을 찾기 위해 7가지 요인(나이, 성별, 키, 몸무게, BMI, 환자 상태 (입원, 외래), dose modulation 활성화 유무)과 CT 선량과의 상관관계를 확인하였다. 상관관계 확인을 위해 사용된 통계기법으로는 로지스틱 회귀분석을 사용하였다. 흉부 저선량 CT 검사에서는 키가 클수록, BMI 가 높을수록, dose modulation을 비활성화한 경우에 진단참고수준 (diagnostic reference levels, DRL) 기준치의 초과 위험률이 낮아졌다 (odds ration<1; p<0.05). 또한 여성의 경우와 몸무게가 클수록 DRL 기준치의 초과 위험률이 높아졌다 (odds ration>1; p<0.05). 복부 비조영 CT 검사에서는 몸무게가 클수록, dose modulation을 비활성화한 경우에 DRL 기준치의 초과 위험률이 낮아졌다 (odds ration<1; p<0.05). 이처럼 방사선 피폭에 영향을 주는 다양한 요인에 대한 연구를 수행하여 환자 선량과의 연관성을 찾고 이에 따른 선량을 낮추는 노력이 필요할 것으로 사료된다.