Proceeding of Spring/Autumn Annual Conference of KHA
/
2003.11a
/
pp.283-288
/
2003
This study has analyzed the environmental characteristics of Cheong-Ju city and the priority of residential choice elements by residents. The results of analysis are as follows. 1) The rate of housing supply in Cheong-ju city is low at 80.2%, concentrated on small sized apartments. Furthermore educational and traffic facilities are much insufficient. 2) While residential choice in Chong-ju is heavily characterised by educational surroundings, it is less affected by both economy such as housing prices, the value of investments and accessibility to public transportations, distance to working places. 3) It is affected by residents' general characters like the sell age, life cycle, education level, properties, home ownership, number of room and type of house they want.
Kim, Sang-Yong;Jeong, Woo-Yang;Yi, Keun-Man;Kim, Chang-Il
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2009.06a
/
pp.118-119
/
2009
This paper presents the feature profile evolution silicon deep trench etching, which is very crucial for the commercial wafer process application. The silicon deep trenches were etched with the SF6 gas & Hbr gas based process recipe. The optimized silicon deep trench process resulted in vertical profiles (87o~90o) with loading effect of < 1%. The process recipes were developed for the silicon deep trench etching applications. This scheme provides vertically profiles without notching of top corner was observed. In this study, the production of SF6 gas based silicon deep trench etch process much more strongly than expected on the basis of Hbr gas trench process that have been investigated by scanning electron microscope (SEM). Based on the test results, it is concluded that the silicon deep trench etching shows the sufficient profile for practical MOS FET silicon deep trench technology process.
Kim, Sang-Yong;Jeong, Woo-Yang;Yi, Keun-Man;Kim, Chang-Il
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2009.06a
/
pp.88-89
/
2009
In this paper, we investigated about wet cleaning effect as deep trench formation methods for Power chip devices. Deep trench structure was classified by two methods, PSU (Poly Stick Up) and Non-PSU structure. In this paper, we could remove residue defect during wet. cleaning after deep trench etch process for non-PSU structure device as to change wet cleaning process condition. V-SEM result showed void image at the trench bottom site due to residue defect and residue component was oxide by EDS analysis. In order to find the reason of happening residue defect, we experimented about various process conditions. So, defect source was that oxide film was re-deposited at trench bottom by changed to hydrophobic property at substrate during hard mask removal process. Therefore, in order to removal residue defect, we added in-situ SCI during hard mask removal process, and defect was removed perfectly. And WLR (Wafer Level Reliability) test result was no difference between normal and optimized process condition.
Objectives: There is no report on treatment of acute traumatic rotator cuff tear in Traditional Korean Medicine. We reported Traditional Korean Treatment for pain relief and better movement of acute traumatic rotator cuff tear. Methods: Shoulder MRI was used to confirm the diagnosis of tear of rotator cuff. The patient was treated with Traditional Korean Methods (Acupuncture, Herbal medicine, Pharmacopuncture) for 6 months. We evaluated the patient through VAS (Visual Analogue Scale), UCLA shoulder scale, ROM (Range of motion) and Shoulder MRI. Results: After 6 months of treatment, the patient's VAS was decreased whereas UCLA score and Shoulder ROM were increased. Rotator cuff tear was repaired on Shoulder MRI images. Conclusions: In acute traumatic rotator cuff tear, Korean Traditional Treatment is good method for pain relief and better movement.
Purpose: The purpose of this study is to present basic data which would be applied on the early stage of the architectural design. And that determines the introduction of the atrium by comparing and analysing the environmental performance of atrium building. Method: The building forms are classified into low storied building, middle storied building and high storied building. This study compares and analyses energy performance of the standard building without atrium and the atrium building which has one-side, two-side, three-side, four-side, and linear atrium by measuring of annual heating and cooling load with EnergyPlus. Result: As a result of the analysis of the relative annual heating and cooling load by building type, it is shown that the fluctuation of cooling load in low storied building is large because heat storage in atrium affects building, and the fluctuation of heating load in high storied building is large owing to the effect of external wall area of atrium which makes heat loss. Especially, it indicated the largest annual heating and cooling load in four-side atrium of low storied building, and in one-side atrium of high storied building.
Journal of the Korean Institute of Rural Architecture
/
v.16
no.1
/
pp.63-70
/
2014
This study is aimed to represent the streetscape in 1960s' focused on Seong-An street of Cheong-ju through the existing business types and buildings, literature, photo details, and interview of the longest-term householders. Results of this study are as follows : Firstly, the types of 1st-floor shops were diverse with general merchandise, apparel, medical, bank, restaurant, and etc in 1960s'. The present shops of them are 'Dong-kwang lasa', 'Jung-geum dang', 'Cheong-ju pharmacy' including the existing 'the Korea development', 'Korea first', and 'Woori' bank. Secondly, the streetscape around post office looks just as it did in the old 1960s'. In the other section the present typical buildings are 'Namseon pharmacy ', 'Kukje department', 'Samyang shop', 'Daeyang shop', 'Park shop', and etc. These old 3-4story buildings are reinforced concrete in contrasted with the former wooden and masonry in structure, and converted in use and appearance. Thirdly, the streetscape of Seong-An is ultimately represented by presuming the other buildings and equipments through aerial and street photograph in the old 1960s'.
Proceedings of the Korea Information Processing Society Conference
/
2005.11a
/
pp.71-74
/
2005
유비쿼터스 헬스케어는 생체신호 측정기술과 생체신호 측정기의 소형화 경량화로 인해 의료분야의 획기적인 변화를 가져올 것으로 기대된다. 그러나 생체신호 측정 기술의 발전에 비해서 대부분의 생체신호 데이터는 각 시스템 고유의 데이터 포맷을 사용하기 때문에 사용범위가 제한되고 데이터 공유 및 호환에 어려움이 있어 구조적이며 시스템 독립적인 XML을 사용하여 생체신호 데이터를 표현하는 방법이 필요하다. 본 논문에서는 XML 기반의 HL7 Annotated ECG(HL7 aECG) 표준을 이용해서 생체신호 데이터를 표현하고 저장하는 방법을 제시한다. 제시된 방법은 ECG, 심음의 두채널 파형 정보를 포함한 바이너리 포맷을 HL7 aECG 문서로 표현하며, HL7 aECG 문서의 특성을 고려하여 비분할 저장 방식을 사용하고 효율적인 검색을 위해 메타데이터를 추출하여 관계형 테이블에 저장하는 분할 저장 방식을 병행하여 사용한다. 또한 저장된 메타데이터를 효율적으로 검색 및 관리하는 메타데이터 시스템을 설계하며 설계된 구조는 향후 다른 시스템과 연계의 가능성을 제공한다.
In this paper, the large data processing and suitable FAT32 file system for industrial system using a PLC and CF memory was implemented. Most of PLC can't save the large data in user data memory. So it's required to the external devices of CF memory or NAND flash memory. The CF memory is used in order to save the large data of PLC system. The file system using the CF memory is NTFS, FAT, and FAT32 system to configure in various ways. Typically, the file system which is widely used in industrial data storage has been implemented as modified FAT32. The conventional FAT 32 file system was not possible for multiple writing and high speed data accessing. The proposed file system was implemented by the large data processing module can be handled that the files are copied at the 40 bytes for 1msec speed logging and creating 8 files at the same time. In a sudden power failure, high reliability was obtained that the problem was solved using a power fail monitor and the non-volatile random-access memory (NVSRAM). The implemented large data processing system was applied the modified file system as FAT32 and the good performance and high reliability was showed.
In this paper, the parabolic antenna aims to the precise location of a moving ship or car that can be designed system using the gyro sensor. The parabolic antenna has controlled by stepping motor that is a lot of noise and slow response of speed. It has solved the problem which is noise and slow response using the BLDC motor. Also, in order to suppress the noise two-axis control and a separate encoder to the six degrees of freedom motion system was implemented in a precise location. Generally, the gyro sensor is not required to system that doesn't move the six degrees of freedom motion system. But the system will be applied to the moving such as ships or cars. Finally, we presented the position control algorithm at the sometimes controlled both gyro sensor and BLDC motor. This system was tracking that the location of the antenna to the desired angle and errors almost didn't happen when the system was moved 6 degrees of freedom.
This paper is to improve the problem of the LED dimming control system using the conventional PWM and DAC method. The conventional PWM method controls the average current to switch dimming signal. This method generates the flicker when controlling at a low current. In order to solve the problem, this system prevents the flicker with the DAC method. The LED is lit at micro-current flowing in the LED. And offset voltage is generated in the output of the DAC when the DAC output is very low voltage as 0V. This was resolved by the voltage drop of the output voltage to construct a negative offset circuit. In addition, the LED current can't flow as set values because of overheating of FET. In order to solve the problem, the 16 bits ADC in the microprocessor is a more accurate current control receives the LED current in comparison with the set value. Therefore, the LED dimming control system proposed in this paper showed the accurate and reliable more than conventional systems.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.