• Title/Summary/Keyword: Chemiluminescent immunoassay

Search Result 16, Processing Time 0.026 seconds

Comparison of chemiluminescence immunoassay (CIA) and immunochromatography assay(ICA) for Detecting HBsAg and Anti-HBs (B형 간염항원 및 항체 검사를 위한 화학발광면역검사법(CIA)과 면역크로마토그래피법(ICA)의 비교분석)

  • Kim, Hye-Jeong;Kim, Eun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3419-3424
    • /
    • 2013
  • Diverse immunoassays including a chemiluminescent immunoassay (CIA) are used to detect hepatitis B surface antigen (HBsAg) and antibody (anti-HBs). Recently, an increasing number of institutions have been utilizing an immunochromatography assay (ICA), which is easy to use. In this study, We evaluated ICA kits for the rapid detection of HBsAg and anti-HBs by comparing them with a CIA. A total of 120 serum hospital samples, were collected for the whole month, were assayed using ICA kit. The Concordance rate, sensitivity, specificity, positive predictive value and negative predictive value of the ICA for HBsAg based on CIA results were 97%, 97%, 100%, 100%, and 96.8%, respectively. The diagnostic performances of the ICA for Anti-HBs were 90%, 90%, 93.3%, 93.1%, and 90.3%, respectively. The ICA kit failed to detect HBsAg and anti-HBs in low reactive samples. The ICA kits for the rapid detection of HBsAg might be recommended for interpreted with caution and dual analysis in the clinical laboratory.

Development of a Rapid Automated Fluorescent Lateral Flow Immunoassay to Detect Hepatitis B Surface Antigen (HBsAg), Antibody to HBsAg, and Antibody to Hepatitis C

  • Ryu, Ji Hyeong;Kwon, Minsuk;Moon, Joung-Dae;Hwang, Min-Woong;Lee, Jeong-Min;Park, Ki-Hyun;Yun, So Jeong;Bae, Hyun Jin;Choi, Aeran;Lee, Hyeyoung;Jung, Bongsu;Jeong, Juhee;Han, Kyungja;Kim, Yonggoo;Oh, Eun-Jee
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.578-584
    • /
    • 2018
  • Background: Accurate, rapid, and cost-effective screening tests for hepatitis B virus (HBV) and hepatitis C virus (HCV) infection may be useful in laboratories that cannot afford automated chemiluminescent immunoassays (CLIAs). We evaluated the diagnostic performance of a novel rapid automated fluorescent lateral flow immunoassay (LFIA). Methods: A fluorescent LFIA using a small bench-top fluorescence reader, Automated Fluorescent Immunoassay System (AFIAS; Boditech Med Inc., Chuncheon, Korea), was developed for qualitative detection of hepatitis B surface antigen (HBsAg), antibody to HBsAg (anti-HBs), and antibody to HCV (anti-HCV) within 20 minutes. We compared the diagnostic performance of AFIAS with that of automated CLIAs-Elecsys (Roche Diagnostics GmbH, Penzberg, Germany) and ARCHITECT (Abbott Laboratories, Abbott Park, IL, USA)-using 20 seroconversion panels and 3,500 clinical serum samples. Results: Evaluation with the seroconversion panels demonstrated that AFIAS had adequate sensitivity for HBsAg and anti-HCV detection. From the clinical samples, AFIAS sensitivity and specificity were 99.8% and 99.3% for the HBsAg test, 100.0% and 100.0% for the anti-HBs test, and 98.8% and 99.1% for the anti-HCV test, respectively. Its agreement rates with the Elecsys HBsAg, anti-HBs, and anti-HCV detection assays were 99.4%, 100.0%, and 99.0%, respectively. AFIAS detected all samples with HBsAg genotypes A-F and H and anti-HCV genotypes 1, 1a, 1b, 2a, 2b, 4, and 6. Cross-reactivity with other infections was not observed. Conclusions: The AFIAS HBsAg, anti-HBs, and anti-HCV tests demonstrated diagnostic performance equivalent to current automated CLIAs. AFIAS could be used for a large-scale HBV or HCV screening in low-resource laboratories or low-to middle-income areas.

Alternative Immunossays

  • Barnard, G.J.R.;Kim, J.B.;Collins, W.P.
    • Korean Journal of Animal Reproduction
    • /
    • v.9 no.2
    • /
    • pp.133-139
    • /
    • 1985
  • An immunoassay may be defined as an analytical procedure involving the competitive reaction between a limiting concentration of specific antibody and two populations of antigen, one of which is labelled or immobillized. The advent of immunoassay has revolutionised our knowledge of reproductive physiology and the practice of veterinary and clinical medicine. Radioimmunoassay (RIA) was the first of these methods to be developed, which meausred the analyte with good sensitivity, accuracy and precision (1,2). The essential components of RIA are:-(i) a limited concentration of antibodies, (ii) a reference preparation, and (iii) an antigen labelled with a radioisotope (usually tritium or iodine-125). Most procedures invelove isolating the antibody-bound fraction and measuring the amount of labelled antigen. Good facilities are available for scintilltion counting, data reduction nd statistical analysis. RIA is undergoing refinement through:-(i) the introduction of new techniques to separate the antibody-bound and free fractions which minimize the misclassification of labelled antigen into these compartments, and the amount of non-specfic binding. (3), (ii) the development of non-extration for the measurement of haptens (4), (iii) the determination of a, pp.rent free (i.e. non-protein bound) analytes (5), and (iv) the use of monoclonal antibodies(6). In 1968, Miles and Hales introduced in important new type of immunoassay which they termed immunora-diometric assay (IRMA) based on t도 use of isotopically labelled specific antibodies(7) in a move from limited to excess reagent systems. The concept of two-site IRMAs (with a capture antibody on a solid-phase, and a second labelled antibody to a different antigenic determinant of the analyte) has enabled the development of more sensitive and less-time consuming methods for the measurement of protein hormones ovar wide concentration of analyte (8). The increasing use of isotopic methos for diverse a, pp.ications has exposed several problems. For example, the radioactive half-life and radiolysis of the labelled reagent limits assay sensitivity and imposes a time limit on the usefulness of a kit. In addition, the potential health hazards associated with the use and disposal of radioactive cmpounds and the solvents and photofluors necessary for liquid scientillation counting are incompatable with the development of extra-laboratory tests. To date, the most practical alternative labels to radioisotopes, for the measurement of analytes in a concentration > 1 ng/ml, are erythrocytes, polystyrene particiles, gold sols, dyes and enzymes or cofactors with a visual or colorimetric end-point(9). Increased sensitivity to<1 pg/ml may be obtained with fluorescent and chemiluminescent labels, or enzymes with a fluorometric, chemiluminometric or bioluminometric end-point. The sensitivity of any immunoassay or immunometric assay depends on the affinity of the antibody-antigen reaction, the specific activity of the label, the precision with which the reagents are manipulated and the nonspecific background signal (10). The sensitivity of a limited reagent system for the measurement of haptens or proteins is mainly dependent upon the affinity of the antibodies and the smalleest amount of reagent that may be manipulated. Consequently, it is difficult in practice to improve on the sensitivity obtained with iodine-125 as the label. Conversely, with excess reagent systems for the measurement of proteins it is theoretically possible to increase assay sensitivity at least 1000 fold with alternative luminescent labels. To date, a 10-fold improvement has been achieved, and attempts are being made to reduce the influence of other variables on the specific signal from the immunoreaction.

  • PDF

Comparison between the method of the measurement 25 Vitamin D3 (25 Vitamin D3 측정에 있어서 화학발광미세입자 측정법과 화학발광면역 측정법 간의 비교 및 고찰)

  • Kim, dae-won;Lee, jung-hee;Jung, an-na;Seo, so-yoen
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.112-114
    • /
    • 2015
  • Purpose Vitamin D to Anti- Rickets both steroid compounds showing activity, By acting on bone tissue secretary and the key to maintain serum Ca homeostasis. The blood level of vitamin D is the largest in D3 that the concentration of the metabolite is reflected in the holding state of vitamin D in vivo. Sunlight to change the 7-dehydrocholesterol in the skin and through the skin to D3, In the liver in combination with the D2 and D3 D4 changes. The Radioimmunoassay(RIA) method is measuring the D 3, the sensitivity can be measured also difficult trace substance to measure the normal test because it is very sensitive, but recently, a check is possible, for the Total D3 in Chemimicroparticle immunoassay(CMIA) or Chemiluminescent immunoassay(CLIA) measuring using microparticle RIA and CMIA(Architect i2000SR) / use the CLIA(DXI-800) method to compare and evaluate the correlation between the tests in the same test items. Materials and Methods Commissioned from January 2014 to March 2015 patients were enrolled in a total of 273 people. 29 out of 273 people conducted by RIA were compared with CMIA, 244 patients were compared with CLIA. Using reagents and equipment were used RIA(Diasource), CMIA(Architect i2000SR, Abbott Diagnostics) / CLIA( Unicel DXi-800, Beckman coulter). Results Correlation of the RIA and CLIA was a R2 = 0.1844 (y = 0.7303x + 3.9005), and the correlation of RIA CMIA is R2 = 0.2762 (y = 0.8862x + 4.56) respectively. (According to statistics, during the same period RIA is Deficiency 4.31%, Insufficiency 90.53%, Sufficiency 5.16%, was Excess 0%, CLIA / CMIA is Deficiency 17.02%, Insufficiency 75.91%, Sufficiency 7.03%, indicating the distribution of 0.03 % Excess) Conclusion Serum vitamin D and parathyroid hormone that show an inverse relationship, the level above which are not parathyroid hormone and vitamin D reduced the increase. The density is different for each study, at most 20 is reported to be the maximum between 30 ng / ml. In Korea it requires a proposed standard of vitamin D deficiency, reference to the WHO lack the case more than 10ng/ml, 20ng/ml and defined by the lack of, if not more than, the IOM, but looking at 12ng/ml or less to the normal to lack, at least 20ng/ml, the reference do not match the deficit under 20ng/ml, 21-29ng/ml relative lack between, was also defined as a sufficient condition for more than 30ng/ml. Although not statistically is between RIA and CLIA two ways to vitamin D levels change according to season match, when seasonally seen in summer as commonly known (April to September), winter (October to March) relative to the increase measured than it was found. Finally, the study on the correlation between the two methods have been expected to result in a consistent and apply the same view high reference value on the graph is difficult. However, there may be differences between the test equipment and methods, and could be especially the case of RIA method using an organic solvent is difficult to compare different methods and correlated view similar trend in vitamin D deficiency and quarterly aspect ratio.

  • PDF

Associations of Perceived Stress Level, Serum Cortisol Level, and Telomere Length of Community-dwelling Adults in Korea (지역사회 거주 성인의 지각된 스트레스, 혈중 코티졸 수준 및 텔로미어 길이의 관련성)

  • Kim, A Young;Kim, Nahyun
    • Journal of Korean Biological Nursing Science
    • /
    • v.24 no.4
    • /
    • pp.235-242
    • /
    • 2022
  • Purpose: To investigate associations of perceived stress level, serum cortisol level, and telomere length of community-dwelling adults in Korea. Methods: Data of a total of 135 community-dwelling adults aged over 40 years living in D metropolitan city from December 2020 to March 2021 were collected. Perceived stress level over the past month were measured using the Perceived Stress Score. Serum cortisol level was analyzed using a chemiluminescent microparticle immunoassay. Telomere length was determined using quantitative real-time polymerase chain reaction. The statistical package SPSS 23.0 was used to perform Chi-square test, independent t-test, and Pearson's correlation coefficient analysis. Results: There was no association between perceived stress and serum cortisol level (r = .07, p= .402). Serum cortisol level was not significantly associated with telomere length either (r = -.15, p= .081). However, the higher the perceived stress level, the shorter the telomere length (r= -.29, p= .001). Conclusion: These results suggest that perceived stress might induce physiological stress, which might partially affect gene biology. Further longitudinal research is needed to investigate the effect of perceived stress on telomere length. Intervention for relieving stress should be included in stabilizing the genetic environment of adults.

Age-related Changes in blood Chemistry and Thyroid hormones in Senescence Accelerated Mice(SAM R1 and SAM P6) (노화 방지를 위한 한약재의 효능 연구 (I))

  • Kim, Chung-Sook;Lee, Je-Hyun;Ma, Jin-Yeul;Jeon, Won-Kyung
    • Korean Journal of Oriental Medicine
    • /
    • v.1 no.1
    • /
    • pp.401-418
    • /
    • 1995
  • Aging process can be explained by many factors. In this study, we counted complete Blood Cells (CBC) such as WBC, Lymphocytes, Monocytes, Granulocytes, RBC, HGB, and HCT of both SAM P6 and SAM P1 during the aging process. Plasma albumin, glucose, alkaline phosphatase, calcium, creatinine, inorganic phosphate, urea concentrations were also measured at the same time. In addition to these, plasma concentrations of cortisol, total T3, and total T4 were analyzed by Chemiluminescent Immunoassay. There were no change in CBC counts of SAM R1 and SAM P6 during this study. Plasma concentratins of albumin and glucose decreased significantly in SAM R1. However, plasma alkaline phosphatases and creatinine concentration in SAM P6 decreased significantly at 16 week after birth comparing to the control. Total T4 levels were siginificantly increased although cortisol and total T3 concentrations were the same in SAM R1 groups. Especially, the after birth of creatinine, alkaline phosphatase, T4 of SAM P6 at 16 week were significantly different form those of SAM R1. At 12 week after birth, pilose antler extract was given 5g/kg/day p.o. for 0, 7, 14, 21, and 30 days each in both SAM R1 and SAM P6. The RBC, HGB, and HCT levels started to increase significantly from 7 days after the dose at SAM P6 only. Total T4 conectrations were elevated gradually during the study although the antler extract administration did not prevent or inhibit the increase in total T4 concentration during the study. Therefore, the elevation of erythrocytes after administration of the extract needs to be studied in future.

  • PDF

Changes in Physiological Responses of Senescence Accelerated Mice(SAM) P6 and SAM R1 by Administration of Herbal Merbal Medicine Extracts (한약의한 의향 SAM P6와 SAM R1의 생리적인 변화)

  • 김정숙;김연태;이제현;하혜경;전원경;한상섭
    • Biomolecules & Therapeutics
    • /
    • v.5 no.1
    • /
    • pp.23-35
    • /
    • 1997
  • Physiological effects in SAM P6 and Rl by administration of Cervus cornu, Astragali Radix, Rehmanniae Radix, and Angelicae Radix extracts were screened to know in vivo activities of each extracts. We measured complete blood cells (CBC) such as aBC, HGB, and HCT using coulter's method. Plasma concentrations of albumin, glucose, alkaline phosphatase, calcium, creatinine, inorganic phosphate, urea and total iron ere also analyzed using biochemical clinical autoanalyzer. Plasma concentrations of cortisol, total T$_3$, and total T$_4$ were measured by chemiluminescent immunoassay methods. At 12 weeks after birth, Cervus conu or Astragali Radix or Rehmanniae Radix extracts were given 5 g/Kg.day p.o. for 0,7,14,21, and 30 days each in both SAM Rl and SAM P6. Angelicae Radix study was done the same as the others except the mice were 16 weeks after birth. The RBC, HGB, and HCT levels after administration of Astragali and Rehmanniae were elevated in SAM Rl, but those in Cervi study were increased in SAM P6 the most. Decreases in alkaline phosphatase concentration of SAM Rl and P6 after Cervi administration were detected. Total plasma iron concentration was decreased by Angelicae administration in SAM P6. In general, Angelicae and Rehmanniae stimulate increases in cortisol, but total T$_3$ and T$_4$ levels were also elevated by all these extracts. In conclusion, these herval medicine extracts help hematopoiesis in SAMs through probably different mechanisms.

  • PDF

Studies on the Rapid and Competitive Enzyme-linked Immunosorbent Assay for the Detection of Thyroxine (T$_4$) in Human Sera (경쟁적 효소면역측정법을 이용한 환자 혈청 내 Thyroxine (T$_4$)의 검출)

  • Sang-Wook Park;Jong-Bae Kim
    • Biomedical Science Letters
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 1999
  • Thyroxine (3,5,3',5'-L-tetraiodothyronine; T$_4$) is the most commonly measured thyroid hermono for the diagnosis of various thyroid disorders. Although radioimmunoassay (RIA) is still considered as the reference technique for the measurement of T$_4$, it is generally regarded that RIA has its primary disadventages in handling the wastes and controling the human and material resources. Therefore, establishment of enzyme-linked immunosorbent assay (ELISA) has of great significance. To verify the usefulness of our enzyme immunoassay, we have obtained the standard dose response curve of T$_4$ in patient's sera which is inversely proportional to the amount of herseradish peroxidase (HRP) conjugated monoclonal antibody of T$_4$ bound to the wells. The correlation coefficient (r) between the ELISA and chemiluminescent assay was 0.444 (n=38). Thus we have investigated the establishment of rapid and sensitive competitive ELISA assay method for detection of T$_4$ in patient's sera.

  • PDF

The Relation between Exposure to Environmental Tobacco Smoke and the Quantity of Cotinine in the Urine of School Children in Taif City, Saudi Arabia

  • Desouky, Dalia El Sayed;Elnemr, Gamal;Alnawawy, Ali;Taha, Azza Ali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.139-145
    • /
    • 2016
  • Environmental tobacco smoke (ETS) is a major public health problem for all ages. Despite the high prevalence of smoking among the Saudi population, there is limited information about levels of urinary cotinine in Saudi children exposed to SHS. The aim of the study was to assess the exposure of schoolchildren to ETS, and measure their urinary cotinine levels. Multistage cluster sampling was carried out, where schoolchildren from 4 schools were randomly chosen from primary schools in Taif city. A questionnaire including questions on SHS exposure and smoking rules in the residence were sent to students parents/guardians. Urine samples were taken and analyzed for total cotinine using chemiluminescent immunoassay. Of the studied children, 38.4% had a smoking father, 61.8%, 41.2% and 49.3% of them were exposed to ETS indoors, outdoors and both indoors and outdoors respectively. The mean urinary cotinine was significantly higher among children exposed to ETS compared to unexposed children. Urinary cotinine levels in children with both indoor and outdoor exposure was significantly higher compared with its level in children with single exposure. A significant positive correlation was found between urinary cotinine concentrations and the number of cigarette packs smoked by parents, and the number of smokers in the residence. The mean urinary cotinine level was significantly higher in children who reported no smoking rules at the residence.. The study revealed a high exposure of Saudi children to ETS. An antismoking media awareness campaign on the harmful effects of ETS should be carried out, in addition to family counseling programs targeted to parents to protect their children from ETS.

Association of serum 25-hydroxyvitamin D concentrations with Schirmer tear test 1 and tear film breakup time in dogs

  • Youngsam Kim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.2
    • /
    • pp.32.1-32.10
    • /
    • 2023
  • Background: The association between vitamin D and canine keratoconjunctivitis sicca (KCS) has not been investigated in dogs. Objectives: To investigate the association of serum 25-hydroxyvitamin D [25(OH)D] concentrations with Schirmer tear test 1 (STT-1) and tear film breakup time (TFBUT) in dogs. Methods: Sixty-one clinically healthy, client-owned dogs were enrolled. STT-1 and TFBUT were measured in 122 (61dogs) and 82 (41 dogs out of total 61 dogs) eyes, respectively. Serum 25(OH)D concentrations were evaluated by quantitative chemiluminescent immunoassay. The dogs were classified into 6 groups according to the evaluations (STT-1: group 1, normal [≥ 15 mm/min] in both eyes; group 2, normal in one eye and abnormal [< 15 mm/min] in the fellow eye; group 3, abnormal in both eyes; TFBUT: group 4, normal [≥ 20 sec] in both eyes; group 5, normal in one eye and abnormal [< 20 sec] in the fellow eye; group 6, abnormal in both eyes). Results: STT-1 was positively correlated with TFBUT (p < 0.001). Among the STT-1 groups, the mean serum 25(OH)D concentration in group 1 was significantly higher than in groups 2 and 3 with positive correlation (p < 0.001). However, there were no significant differences among the TFBUT groups 4, 5, and 6. Conclusions: In dogs, it was found that serum 25(OH)D concentrations had a greater effect on quantitative KCS than qualitative KCS. Therefore, it is considered that measurement of serum 25(OH)D concentration could be included in the diagnostic tests in canine quantitative KCS patients.