Radiosterilization of Medical Producys(IV) (전이방사선을 이용한 의약제품 멸균연구 IV)

  • 이강순;천기정;김기수
    • Korean Journal of Microbiology
    • /
    • v.15 no.2
    • /
    • pp.85-92
    • /
    • 1977
  • We have in vestigated on physico-chemical and biological test of plastic transfusion set which was manufactured from the three companies after $Co^{60}\;{\gamma}-radiation$. The results obtained were as follows ; 1) In physico-chemical test generally showed a tendency to decrease of pH and tensile strength, and increase of oxidizable matter, phosphoric acid-phosphosphate and heavy metals in its eluted solution by irradiation of 2,5 Mrad. 2) In biological test including toxicity and safety test were passed but indicating haemolysis range the haemolysis test were failed to pass from 30% to 50%. 3) We have found that the raw materials of plastic transfusion set according to manufactures are all different and especially the most radioresistant raw material wss found in the product which was manufactured from C company.

  • PDF

Analysis on the Results of the Rockwell Hardness Round Robin Test (로크웰 경도도 순회 비교측정 결과에 대한 분석)

  • Bahng, G.W.;Tak, N.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.5
    • /
    • pp.275-281
    • /
    • 2001
  • To improve the reliability of hardness test results, Rockwell hardness round robin test was carried out for 10 laboratories. The test condition was the same with the ISO(International Standards Organization) standards. Korea Research Institute of Standards and Science(KRISS) supplied the hardness standard blocks and an indenter to laboratories for the measurement. The participating laboratories measured hardness of the specified areas on the blocks for 6 times with their own indenter as well as common indenter, respectively, and reported the results to KRISS. The result showed that quite large amount of the differences came from the indenter and it is necessary to change indenter with better quality for improved reliability in hardness measurement.

  • PDF

Solar Cell Reliability Data Bank (태양전지 신뢰성 정보은행)

  • So, Wonshoup;Oh, Soo Young
    • Current Photovoltaic Research
    • /
    • v.2 no.3
    • /
    • pp.140-145
    • /
    • 2014
  • The globally used PV qualification tests and reports the pass/fail only. Therefore, the reliability of new PV materials and parts can't be compared quantitatively with the reliability of the PV parts and materials in the market. Global PV materials and parts companies test and compare their materials, parts, and modules using the failure-to-test (FTT). However, it takes a long accelerated stress test (AST) until failure. It also needs to test the new and existing materials and parts. Therefore, it requires excessive equipment time and cost. In order to reduce the time and cost, a new reliability enhancement methodology has been developed. It tests the PV materials, parts, and modules in the global market and stores them in the PV reliability database. It reduces the time and cost of the comparison and enhancement of PV reliability. An example of the reliability enhancement of the PV encapsulant, EVA is presented.

A Case Study on Using Uncritical Inference Test to Promote Malaysian College Students' Deeper Thinking in Organic Chemistry

  • Kan, Su-Yin;Cha, Jeongho;Chia, Poh Wai
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.2
    • /
    • pp.156-163
    • /
    • 2015
  • In Malaysia, the students' poor performance in mathematics and sciences needs immediate attention and remedies. In order to tackle this problem, an active learning environment that encourages students' question-asking capability must be molded. Transformation from traditional teacher-based approach to active-learning classroom is the key to develop question-asking capability. The classroom activity that the authors used in this study is based on the uncritical inference test to promote students' deeper thinking which encouraged students to verify facts that was previously learnt in classroom through group discussion activity. Three sets of uncritical inference test were developed and applied to Malaysian college course of basic organic chemistry. Students' answers to the impact of using uncritical inference test with a group discussion on learning and communication skills were positive.

A study on the strengthening of Sodalime glass using ion exchange method (이온강화법을 이용한 소다라임 글라스 강화에 관한 연구)

  • Ahn, H.W.;Oh, J.H.;Kweon, S.G.;Choi, S.D.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.145-151
    • /
    • 2014
  • The glass used for mobile display windows is required to have high strength. Chemical strengthening by means of ion exchange is widely used glass. The depth of the layer and the compressed stress are affected by tempering temperature and time. The purpose of this study is to investigate the range of DOL and CS, which to less breakage during reliability tests such as the ball drop test, hole drop test, 3-point bending test, drop test, and tumble test with Soda-lime Glass.

Degradation Accelerated Stress Test of Electrode and Membrane in PEMFC (PEMFC에서 전극과 전해질 막의 열화 가속 시험)

  • Song, Jin-Hoon;Kim, Sae-Hoon;Ahn, Byung-Ki;Ko, Jai-Joon;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.778-782
    • /
    • 2012
  • Until a recent day, degradation of PEMFC MEA (membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. Therefore in this work, AST (Accelerated Stress Test) of MEA degradation was done at the condition that membrane and electrode were degraded simultaneously. There was interaction between membrane degradation and electrode degradation. Membrane degradation reduced the decrease range of catalyst active area by electrode degradation. Electrode degradation reduces increase range of the hydrogen crossover current and FER (Fluoride Emission Rate) by membrane degradation.

Experimental investigation of the aeroelastic behavior of a complex prismatic element

  • Nguyen, Cung Huy;Freda, Andrea;Solari, Giovanni;Tubino, Federica
    • Wind and Structures
    • /
    • v.20 no.5
    • /
    • pp.683-699
    • /
    • 2015
  • Lighting poles and antenna masts are typically high, slender and light structures. Moreover, they are often characterized by distributed eccentricities that make very complex their shape. Experience teaches that this structural type frequently suffers severe damage and even collapses due to wind actions. To understand and interpret the aerodynamic and aeroelastic behavior of lighting poles and antenna masts, this paper presents the results of static and aeroelastic wind tunnel tests carried out on a complex prismatic element representing a segment of the shaft of such structures. Static tests are aimed at determining the aerodynamic coefficients and the Strouhal number of the test element cross-section; the former are used to evaluate the critical conditions for galloping occurrence based on quasi-steady theory; the latter provides the critical conditions for vortex-induced vibrations. Aeroelastic tests are aimed at reproducing the real behavior of the test element and at verifying the validity and reliability of quasi-steady theory. The galloping hysteresis phenomenon is identified through aeroelastic experiments conducted on increasing and decreasing the mean wind velocity.

Characteristics and Pot Test according to Blending of PVA/Algin (PVA와 Algin의 블렌딩에 따른 특성과 토양분해)

  • Cho, Hyung-Jae;Oh, Se-Young;Lee, Ki-Chang;Jung, Duck-Chea;Kim, Yong-Yeul;Hwang, Seong-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.25-31
    • /
    • 1999
  • Algin is known as biodegradable natural polymer from marine plants. PVA/Algin blend films were prepared by solution blending method for the purpose of useful biodegradable polymer. Characteristics properties of PVA/Algin blend films such as DSC, Elongation, Tensile strength and Morphological change by SEM were determined. Tensile strength and Elongation were rapidly reduced as increasing the blend ratio of Algin. PVA/Algin blend films were found that phase separation was occured as more than 25wt% increasing the blend ratio of Algin. Blend films were observed to be less partially compatibility than 10wt% increasing the blend ratio of Algin by DSC, mechanical properties and SEM. Also, PVA/Algin blend films at the laboratory soil test(Pot Test) were completely degraded in months with four kinds of soils by microorganisms.

A Study on the Corrosion Behavior of Magnesium Alloy Sealed with Chemical Conversion Coating and Sol-gel Coating

  • Lee, Dong Uk;Chaudhari, Shivshankar;Choi, Seung Yong;Moon, Myung Jun;Shon, Min Young
    • Corrosion Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.175-182
    • /
    • 2021
  • Magnesium alloy is limited in the industrial field because its standard electrode potential is -2.363 V vs. NHE (Normal Hydrogen Electrode) at 25 ℃. This high electrochemical activity causes magnesium to quickly corrode with oxygen in air; chemical conversion coating prevents corrosion but causes surface defects like cracks and pores. We have examined the anti-corrosion effect of sol-gel coating sealed on the defected conversion coating layer. Sol-gel coatings produced higher voltage current and smaller pore than the chemical conversion coating layer. The conversion coating on magnesium alloy AZ31 was prepared using phosphate-permanganate solution. The sol-gel coating was designed using trimethoxymethylsilane (MTMS) and (3-Glycidyloxypropyl) trimethoxysilane (GPTMS) as precursors, and aluminum acetylacetonate as a ring-opening agent. The thermal shock resistance was tested by exposing specimens at 140 ℃ in a convection oven; the results showed changes in the magnesium alloy AZ31 surface, such as oxidization and cracking. Scanning electron microscope (FE-SEM) analysis confirmed a sealed sol-gel coating layer on magnesium alloy AZ31. Electrochemical impedance spectroscopy (EIS) measured the differences in corrosion protection properties by sol-gel and conversion coatings in 0.35 wt% NaCl solution, and the potentiodynamic polarization test and confirmed conversion coating with the sol-gel coating show significantly improved resistance by crack sealing.

Prediction of Acute Toxicity to Fathead Minnow by Local Model Based QSAR and Global QSAR Approaches

  • In, Young-Yong;Lee, Sung-Kwang;Kim, Pil-Je;No, Kyoung-Tai
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.613-619
    • /
    • 2012
  • We applied several machine learning methods for developing QSAR models for prediction of acute toxicity to fathead minnow. The multiple linear regression (MLR) and artificial neural network (ANN) method were applied to predict 96 h $LC_{50}$ (median lethal concentration) of 555 chemical compounds. Molecular descriptors based on 2D chemical structure were calculated by PreADMET program. The recursive partitioning (RP) model was used for grouping of mode of actions as reactive or narcosis, followed by MLR method of chemicals within the same mode of action. The MLR, ANN, and two RP-MLR models possessed correlation coefficients ($R^2$) as 0.553, 0.618, 0.632, and 0.605 on test set, respectively. The consensus model of ANN and two RP-MLR models was used as the best model on training set and showed good predictivity ($R^2$=0.663) on the test set.