• Title/Summary/Keyword: Chemical resistance concrete

Search Result 283, Processing Time 0.024 seconds

An Experimental Study on the Salt Resistance Properties with Concrete Materials under Marine Environment (Exposure period : 5 years) (해양환경에 폭로한 콘크리트의 내염특성에 대한 실험적 연구 (폭로기간 : 5년))

  • Kim, Yong-Chul;Suk, Jun-Yeoll;Shin, Do-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.169-172
    • /
    • 2006
  • The IIA structures exposed to marine environment is subject to many different types of potential attack. The physical attack due to drying and wetting would increase the internal stress of concrete. The chemical attack resulting from the diffusion of ions$(Cl^-,SO_4^{2-},Mg^+)$ from seawater through the pores in concrete. Therefore the sea water resistance of concrete must be considered when it is used for structure in the ocean. The objective of this study is to evaluate chloride diffusion and corrosion characteristics of concrete when using the various concrete materials under marine environment. After 5 years of exposure, concrete incorporating 40% blast-furnace slag as replacement for type I cement with low w/c ratio of 0.42 and using the inhibitor shows excellent performance.

  • PDF

State-of-the-Art Research and Experimental Assessment on Fire-Resistance Properties of High Strength Concrete (고강도 콘크리트의 내화 특성에 관한 기존연구 고찰 및 실험적 연구)

  • Kim, Woo-Suk;Kang, Thomas H.K.;Kim, Wha-Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.28-39
    • /
    • 2014
  • This paper reviews past literatures relevant to fire-resistance properties of high strength concrete and investigates spalling mechanism of high strength concrete in fire. First, literatures were reviewed on spalling occurrence and fire-resistance methods. Second, a chemical change of concrete components in an elevated temperature was presented. Finally, the mechanism of the spalling occurrence and spalling resistance were examined in terms of hybrid fiber content. The focus of the experimental study as part of this research is to investigate the effects of fire on the variation of thermal properties of high strength concrete, which tends to be used in super tall buildings. This experimental study was devised to investigate the fire-resistance performance of high strength concrete containing hybrid fibers. A total of 48 test specimens were exposed to high temperature ranging from $100^{\circ}C$ to $700^{\circ}C$, including room temperature (${\sim}20^{\circ}C$). Test results provide valuable information regarding fire-resistance properties of strength concrete with 100 MPa or greater.

Experimental Study on Correlation Analysis of Air-void, Air-spacing factor and Long-term Durability for Roller-compacted Concrete pavement (롤러 전압 콘크리트 포장의 공기량 및 기포간격계수와 장기 내구성의 상관관계 분석을 위한 실험적 연구)

  • Lee, Jun Hee;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.18 no.1
    • /
    • pp.63-72
    • /
    • 2016
  • PURPOSES : The use of roller-compacted concrete pavement (RCCP) is an environmentally friendly method of construction that utilizes the aggregate interlock effect by means of a hydration reaction and roller compacting, demonstrating a superb structural performance with a relatively small unit water content and unit cement content. However, even if an excellent structural performance was secured through a previous study, the verification research on the environmental load and long-term durability was conducted under unsatisfactory conditions. In order to secure longterm durability, the construction of an appropriate internal air-void structure is required. In this study, a method of improving the long-term durability of RCCP will be suggested by analyzing the internal air-void structure and relevant durability of roller-compacted concrete. METHODS : The method of improving the long-term durability involves measurements of the air content, air voids, and air-spacing factor in RCCP that experiences a change in terms of the kind of air-entraining agent and chemical admixture proportions. This test should be conducted on the basis of test criteria such as ASTM C 457, 672, and KS F 2456. RESULTS : Freezing, thawing, and scaling resistance tests of roller compacted concrete without a chemical admixture showed that it was weak. However, as a result of conducting air entraining (AE) with an AE agent, a large amount of air was distributed with a range of 2~3%, and an air void spacing factor ranging from 200 to $300{\mu}m$ (close to $250{\mu}m$) coming from PCA was secured. Accordingly, the freezing and thawing resistance was improved, with a relative dynamic elastic modulus of more than 80%, and the scaling resistance was improved under the appropriate AE agent content rate. CONCLUSIONS : The long-term durability of RCCP has a direct relationship with the air-void spacing factor, and it can be secured only by ensuring the air void spacing factor through air entraining with the inclusion of an AE agent.

The Study on Long-Terms Properties of Concrete Using C Class Fly Ash (C급 플라이애쉬 콘크리트의 장기특성에 관한 연구)

  • Lee, Sang-Soo;Won, Cheol;Kwon, Yeong-Ho;Ahn, Jae-Hyen;Park, Chil-Lim
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.141-145
    • /
    • 1996
  • The primary purpose of this study is to investigate reusal techniques of by-product produced the combined heat power plant in the construction field, which may contribute to the savings of construction materials and the conservation of enviornment. This study is compared and evaluated by testing the chemical resistance, adiabatic temperature rising test, creep and drying shrinkage. As the result of the study, the following conclusions are derived : (1) hydration heat of the fly ash concrete is less than the plain concrete in adiabatic temperature rising test, (2) the fly axh concrete (FA 30%) is similar to the plain concrete in the chemical resistamce, (3) the fly ash concrete (FA 10, 30%) is similar to the plain concrete in drying shrinkage, but the fly ash concrete (FA 50%) is highly increased, (4) the fly ash concrete (FA 30%) is less than the plain concrete in creep test.

  • PDF

Chemical Attack and Carbonation Properties of Latex-Modified Concrete Using Blast-furnace Slag (고로(高爐)슬래그 미분말(微粉末)을 사용(使用)한 라텍스개질(改質) 콘크리트의 화학적(化學的) 침식(侵蝕) 및 탄산화 특성(特性))

  • Hong, Chang-Woo;Jeong, Won-Kyong;Sim, Do-Sik
    • Resources Recycling
    • /
    • v.17 no.5
    • /
    • pp.11-18
    • /
    • 2008
  • The purpose of this study was to evaluate the effects of blast-furnace slag on chemical attack and carbonation of latex-modified concrete (LMC) and ordinary portland cement concrete as slag contents. Main experimental variables were performed latex contents (0%, 15%) and slag contents (0%, 30%, 50%). The compressive strengths, chemical attacks resistance and carbonation depth were measured to analyze the characteristic of the developed LMC and BS-LMC(latex-modified concrete added blast-furnace slag) on hardened concrete. The test results showed that compressive strength of BS-LMC with blast-furnace slag content 30% was quite similar to it of OPC without slag content. The structural quality deterioration was concerned when blast slag content was up to 50%. However, carbonation restraint of BS-LMC with blast-furnace slag 30% was bigger then that of opc. Also, the effects of added latex on OPC and BS-LMC were increased on the carbonation restraint and chemical attacks resistance.

A Study for Chemical Resistance of Polymer Cement Concrete Using Tailing (폐석 미분말을 혼입한 폴리머 시멘트 콘크리트의 내약품성에 관한 연구)

  • 전철수;연규석;이윤수;이필호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.355-360
    • /
    • 1999
  • Polymer cement is made by the modifying ordinary cement concrete with polymer additive. Until now polymer cement concrete is not used for the structural member, but it is growing to be considered as developing uses such as a waterproof of roof slab, the structural member for protecting corrosion, and a road pavement. The plymer cement concrete, being used for those uses, is superior to the cement concrete against the inorganic, organic acid, salt of acetic acid and organic solvents generally. In this paper, the polymer cement concrete was made by the ratio of 1:1 of sands and tailing in fine aggregate in order to solve the environmental pollution which causes the social problem by the tailing, It was measured for the compressive strength, flexural strength, and chemicals resistance was tested by dealing with 10% HCI, 20% NaOH and 10% NaCl aqueous solution.

  • PDF

Magnesium Sulfate Resistance of Concrete Containing Waste Glass (폐유리를 혼입한 콘크리트의 황산마그네슘 저항성에 관한 연구)

  • Kim, Young-Su;Jeong, Yoo-Jin;Lee, Dong-Un
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.3
    • /
    • pp.109-116
    • /
    • 2009
  • The magnesium sulfate solution digestion test carried out for resistance of concrete containing waste glass powder on magnesium sulfate attack. Moreover, it yielded S.D.F index was used for the criteria of quantitative assessment to the resistance of magnesium sulfate for the purpose of evaluation of chemical deterioration on concrete. Furthermore, to evaluate for micro-cracks within concrete and external corrosion, the weight variation of specimens and the dynamic elasticity were compared and analyzed and also the applicability was examined using the analysis of product of hydration through out observing external deformation and micro-structural deformation.

The Fundamental Properties of Mortar Using the Electric Arc Furnace Slag in Chemical Solutions (약품용액에 침지한 전기로슬래그 잔골재 사용 모르터의 기초 물성)

  • 문한영;서정우;윤희경;문재흠
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.683-686
    • /
    • 1998
  • In this paper, we carried out the fundamental experiments on the resistance of chemical attack of mortar using the electric are furnace slag as fine aggregate. The mortar specimens made from the EAF slag as fine aggregate were immersed in four sorts of chemical solutions, and measured to investigate the change of compressive strength and weight. As the results of this study, it was found that compressive strength and weight were increased with incresing replacement ratio of the EAF slag.

  • PDF

An Experimental Study on the Fundamental Properties of Electric Pole Recycled Aggregate(EPRA) and Characteristics of High Strength Concrete by Replacement Ratios of EPRA (폐전주 재생골재의 기초물성 및 대체율에 따른 고강도영역 재생골재 콘크리트의 특성에 관한 실험적 연구)

  • 이강우;이종호;강석표;최세진;최희용;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.495-500
    • /
    • 2001
  • In this study, it was analized and examined fundamental properties of Electric Pole Recycled Aggregate(EPRA) and hardened properties & chemical resistance with H$_2$SO$_4$by replacement ratios of EPRA, and the results are as follows 1) In the case of electric pole recycled coarse aggregate, All fundamental properties are better than that of normal recycled aggregate and both water absorption and amount of crushed loss are with level of natural aggregate 2) As the replacement ratio of electric pole recycled fine aggregate is increased strength development is decreased. but in the case of coarse aggregate, that of it is with level of natural aggregate 3) As the replacement ratio of electric pole recycled fine aggregate is increased chemical resistance is decreased. but in the case of coarse aggregate, that of it is with level of natural aggregate

  • PDF

An Experimental Study on the characteristics of Mortar Using the Ground Granulated Blast-Furnace Slag (고로서냉슬래그 미분말 사용 모르터의 물성에 관한 실험적 연구)

  • Park, Jung-Woo;Choi, Chang-Ki;Kim, Woo-Jae;Kim, Sung-Sik;Lim, Nam-Gi;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.107-112
    • /
    • 2000
  • In this study, when ground granulated blast-furnace slag is intermixed to mortar, the strength test, watertightness test, resistance to chemical attack of hardened mortar are compared and analyzed according to the replacement rate of slag. w/(cc+Bs) and Ground Granulated Blast-furnace slag. As a result, compared with ordinary portland cement, ground granulated blast-furnace slag intermixed concrete shows development of a long term strength, chemical-resistance, and excellent watertightness.

  • PDF