• 제목/요약/키워드: Chemical imaging

검색결과 364건 처리시간 0.03초

두경부암에서 방사면역치료의 역할 (Radioimmunotherapy in Head and Neck Cancer)

  • 최익준
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • 제61권12호
    • /
    • pp.637-643
    • /
    • 2018
  • Radioimmunotherapy (RIT) is a therapy that takes advantage of the "cross-fire" effect of emitted radiation by radionuclides conjugated to tumor-directed monoclonal antibodies (mAb) (including those fragments) or peptides. While RIT has been successfully employed for the treatment of lymphoma, mostly with radiolabeled antibodies against CD20 [$^{90}yttrium$ ($^{90}Y$)-ibritumomab tiuxetan; $Zevalin^{(R)}$ and $^{131}iodine$ ($^{131}I)-tositumomab$; $Bexxar^{(R)}$], its use in solid tumors is more challenging, so far. Immuno-PET, a tool for tracking and quantification of mAbs with PET in vivo, is an exciting novel option to improve diagnostic imaging and guide mAb-based therapy. RIT in solid tumors including head and neck cancer may be an alternative treatment with advances in various biological, chemical, and treatment procedures, and it may help to reduce unnecessary exposure and enhance the therapeutic efficacy. Also, immuno-PET based on RIT might play an important role in cancer staging, in patients or targets selection of targeted therapeutics and in monitoring the response of targeted therapeutics as precision medicine. In this review, fundamentals of RIT/immune-PET and current knowledge of the preclinical/clinical trials in RIT for solid tumor including head and neck cancer are reviewed.

Deep Impact: Molecular Gas Properties under Strong Ram Pressure Probed by High-Resolution Radio Interferometric Observations

  • 이범현;정애리
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.39.3-39.3
    • /
    • 2019
  • Ram pressure stripping due to the intracluster medium (ICM) is an important environmental process, which causes star formation quenching by effectively removing cold interstellar gas from galaxies in dense environments. The evidence of diffuse atomic gas stripping has been reported in several HI imaging studies. However, it is still under debate whether molecular gas (i.e., a more direct ingredient for star formation) can be also affected and/or stripped by ram pressure. The goal of this thesis is to understand the impact of ram pressure on the molecular gas content of cluster galaxies and hence star formation activity. To achieve this, we conducted a series of detailed studies on the molecular gas properties of three Virgo spiral galaxies with clear signs of active HI gas stripping (NGC 4330, NGC 4402, and NGC 4522) based on high-resolution CO data obtained from the Submillimeter Array (SMA) and Atacama Large Millimeter/submillimeter Array (ALMA). As a result, we find the evidence that the molecular gas disk also gets affected by ram pressure in similar ways as HI even well inside of the stellar disk. In addition, we detected extraplanar 13CO clumps in one of the sample, which is the first case ever reported in ram pressure stripped galaxies. By analyzing multi-wavelength data (e.g., Hα, UV, HI, and CO), we discuss detailed processes of how ram pressure affects star formation activities and hence evolution of cluster galaxies. We also discuss the origin of extraplanar 13CO, and how ram pressure can potentially contribute to the chemical evolution of the ICM.

  • PDF

이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구 (The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique)

  • 염헌규;이종민;김용선;이상권;서경진;배성진;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권2호
    • /
    • pp.94-99
    • /
    • 2004
  • 목적 : 인체의 심근 및 간조직의 생체내 $^{31}P$ MRS에서 NOE 효과에 의한 분광신호 세기의 증가를 평가하고자 하였으며 또한 동일 장기에서 대사물질에 따른 NOE 효과의 차이를 알아보고자 하였다. 대상 및 방법: 열명의 정상 성인군(남:여=8:2, 연령분포=24-32)을 대상으로 1.5T 자기공명영상/분광 장치에서 $^1H-^{31}P$ 이중 튜닝 표면 코일을 사용하여 생체내 $^{31}P$ MRS를 시행하였다. $^{31}P$ MRS 측정은 이차원 화학변위영상기법을 사용하였으며 동일한 파라미터에서 NOE 효과 없이 그리고 $^1H$ decoupling상태에서 NOE 효과에 의한 $^{31}P$ MRS 데이터를 획득하였다. $^{31}P$ MRS raw data의 postprocessing 후 얻어진 스펙트럼에서 주요 대사물질들의 신호증가를 비교하였다. 결과: 간조직의 $^{31}P$ HRS에서 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%),\;PME\;(31\%)$였다. 간조직의 경우 크리아틴 키나제가 없기 때문에 PCr 신호는 관찰되지 않았다. 심근의 $^{31}P$ MRS은 whole body 코일이 표면 코일보다 우수한 scout 영상을 제공하여 $^{31}P$ MRS의 localization에 유리하였다. $^{31}P$ 심근 다중 체적 스펙트럼에서 , 혈액의 DPG 신호는 심근으로부터 멀어질 수록 증가하는 양상을 나타내었고 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;PDE\;(51\%),\;DPG\;(72\%)$ 였다. 결론: 간조직에 비해 심근의 경우 큰 신호증가를 보였고 이는 간조직 대사물질들의 $^{31}P$가 심근과는 다른 $^1H$ coupling을 나타냄을 의미한다고 해석할 수 있다.

  • PDF

폐FRP 미분말을 재활용한 BMC 복합재료의 제조 및 기계적 물성 (Preparation and Mechanical Properties of Bulk Molding Compound Composite Prepared using Recycled FRP Waste Powder)

  • 황의환;전종기
    • 공업화학
    • /
    • 제21권2호
    • /
    • pp.217-223
    • /
    • 2010
  • 일반적으로 FRP 폐기물은 단순하게 매립하거나 소각처리하고 있다. 매립은 난분해성으로 인하여 토양을 영구 오염시키고, 소각은 분진과 유독가스를 발생시키게 된다. FRP 폐기물의 처리방법으로 매립, 소각, 화학적 재활용, 재료적 재활용 및 연소열의 에너지활용 등 몇 가지 방법이 알려져 있다. 재료적 재활용을 포함한 모든 처리방법이 경제적 기술적 환경적 관점에서 제한적인 요소를 가지고 있다. 그러나 재료적 재활용방법이 가장 바람직한 방법으로 알려져 있다. 본 연구에서는 재료적 재활용의 가능성을 조사할 목적으로 불포화폴리에스테르수지의 첨가량을 다양하게 변화(25, 30, 35 wt%)시키고 또 충전재 대신 폐FRP 미분말을 대체(0, 25, 50, 75, 100 wt%) 사용하여 다양한 BMC시편을 제조하였다. 제조한 BMC시편의 물리적 특성을 평가하기 위하여 인장강도, 굴곡강도, 충격강도, 내열수성시험 및 전자현미경 관찰을 행하였다. 시험결과 폐FRP 미분말의 치환량이 증가됨에 따라 기계적 강도는 감소되었으며, 내열수성시험에 의하여 시편의 물성은 크게 열화되었다. 폐FRP 미분말의 치환량 50 wt% 이상에서 BMC의 유동성이 크게 저하되어 BMC 복합재료에 문제가 발생하였다.

세로토닌 5-HT1A수용체 방사성 추적자 18F-Mefway의 합성과 소동물 뇌 PET 연구 (Synthesis and Small Animal Brain PET Study of a Serotonin Receptor Radiotracer, 18F-Mefway)

  • 안성민;홍태기;유영훈;최재용;김성철
    • 한국콘텐츠학회논문지
    • /
    • 제9권11호
    • /
    • pp.262-270
    • /
    • 2009
  • 세로토닌 수용체 5-$HT_{1A}$에 대한 방사성추적자로 알려진 $^{18}F$-mefway를 개선된 방법으로 합성하고, 소 동물 뇌 microPET 연구를 통해서 이 수용체에 선택적으로 결합하는 지를 확인하려고 한다. 기존 합성 방법을 수정하여 전구체를 합성하고, $[^{18}F]^-$$130^{\circ}C$에서 30분간 교반하여 $^{18}F$-mefway를 합성하여, Solid phase extraction(SPE)과 HPLC를 이용해 정제한 다음, 소동물 뇌의 microPET 다이나믹 영상을 얻었다. Oxalyl chloride와 LAH/diethyl ether을 사용해서 기존 합성수율 9%에서 34%로 $^{18}F$-mefway 전구체를 향상된 수율로 합성할 수 있는 개선된 방법을 확립하였다. 이렇게 합성된 $^{18}F$-mefway는 세로토닌 5-$HT_{1A}$수용체 영상용 방사성 의약품으로서 신경정신질환 연구에 이용될 수 있을 것으로 사료된다.

근광장 측정에서 방사선 사진술의 정확도 (The Accuracy of the Radiographic Method in Root Canal Length Measurement)

  • 조은영;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

복부 자기공명영상에서 영상의 질 평가: 1.5 T 와 3.0 T 비교 (Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.367-373
    • /
    • 2016
  • 본 연구의 목적은 복부 자기공명영상에서 주로 적용되고 있는 4 종류의 펄스시퀀스를 중심으로 1.5 T 와 3.0 T 기기의 자기장의 차이로 나타나는 자기장의 속성 및 인공물 발생 차이를 비교하기 위해 분석을 하였다. PACS network로 전송된 총 500 명의 데이터를 정량적으로 SNR 값을 분석하였고, MSA, CSA, DA을 3 단계로 구분하여 정성적 평가를 하였다. 정량적 평가에서 SNR 값은 1.5 T 값 보다 의미 있는 결과로 높은 값을 얻었지만(p<0.05), 영상의 인공물이 발생하여 영상의 질을 저하시키는 요인도 있었다(p<0.05). 1.5 T는 3.0 T 보다 인공물 발생이 적어 3.0 T 만큼에 영상의 질을 보상 할 수가 있었다(0.05). 결론적으로, 이러한 결과를 토대로 자기장의 차이에 따라 발생되는 자기장의 속성 및 인공물 발생 차이를 파악 할 수 있었으며 이에 따른 대처방안을 제공할 수 있었다. 향후 임상현장에서 두 기기를 이용하여 복부 자기공명영상을 검사 할 때 환자를 직접 검사하는 MRI 사용자에게 가이드라인이 될 것이다.

말디토프 질량분석을 이용한 고분자의 특성분석 (Analysis of Polymer Characteristics Using Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry)

  • 강민정;성윤서;김문주;김명수;변재철
    • 공업화학
    • /
    • 제28권3호
    • /
    • pp.263-271
    • /
    • 2017
  • 최근에, 질량분석기술의 폴리머 분석에의 응용은 MALDI-TOF MS 개발 이후 급속도로 발전하였다. 이 리뷰 논문은 현재까지 연구된 MALDI-TOF MS의 폴리머 특성분석에의 응용에 관한 최신 논문을 정리하였다. MALDI-TOF MS는 바이오 폴리머와, 합성 폴리머의 평균분자량 분석, 폴리머의 시퀀스 분석을 통한 구조의 해석, 모노머의 조성분석에까지 이용되고 있다. 엔드그룹의 특성과 농도를 분석하는 연구도 많이 진행되었고, 복잡한 폴리머의 분자량의 분석에는 SEC와 MALDI-TOF MS를 연결한 분석법을 추천한다. MALDI에 tandem MS를 결합한 분석기술이나, 이온 모빌리티를 응용한 질량분석기, TOF-SIMS, MALDI-TOF-Imaging 기술도 급격히 발전하고 있으며, 이의 폴리머 특성분석에의 응용은 별도의 분리기술이 필요 없어 앞으로 더 많이 이용될 것으로 생각된다. 분자량, 시퀀스, 그리고 모노머의 조성을 정확하게 계산해주는 소프트웨어와 고분자량(> 100 kDa)의 분석을 가능하게 해주는 기술이 개발된다면, 폴리머를 연구하는 과학자들에게 MALDI-TOF MS의 이용은 문제점을 해결하고, 목적하는 폴리머를 합성하는 데 중요한 수단이 될 것이다.

기판 표면 기능화에 의한 실리카 나노입자의 선택적 패턴 성장 (Selective Pattern Growth of Silica Nanoparticles by Surface Functionalization of Substrates)

  • 김기출
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.20-25
    • /
    • 2020
  • 나노과학과 나노기술의 발전에 따라 선택적 패턴 성장을 위한 기술이 주목을 받고 있다. 실리카(Silica) 나노입자는 바이오 라벨링, 바이오 이미징 및 바이오 센싱에 사용되고 있는 유망한 나노소재이다. 본 연구에서는 실리카 나노입자를 수정된 스토버 방법(Stöber Method)인 졸겔(Sol-Gel) 공정으로 합성하였다. 또한 기판의 표면을 미세접촉프린팅 기술로 발수 처리하여 실리카 나노입자를 선택적으로 패턴 성장시켰다. 합성된 실리카 나노입자의 크기와 선택적으로 패턴 성장된 실리카 나노입자의 표면형상을 전계방출 주사전자현미경(Field Emission Scanning Electron Microscopy, FE-SEM)으로 조사하였고, 기판의 표면 기능화에 따른 기판의 접촉각 특성을 조사하였다. 그 결과 OTS 용액으로 발수 처리된 기판에서는 실리카 나노입자를 스핀 코팅하였을 때, 실리카 나노입자를 관찰할 수 없었으나, KOH 용액으로 친수 처리된 기판에서는 실리카 나노입자가 잘 코팅되는 것을 확인하였다. 또한 미세접촉프린팅 기술로 발수 처리한 기판영역 외에서만 실리카 나노입자가 선택적으로 패턴 성장하는 것을 FE-SEM으로 확인하였다. 이러한 실리카 나노입자의 패턴성장 특성을 염료가 도핑 된 실리카 나노입자에 적용한다면, 실리카 나노입자의 패턴 성장 기술은 바이오 이미징 및 바이오 센싱 분야에 유용하게 활용될 것으로 기대된다.

Differential Diagnosis of Chemical-induced Hepatobiliary Toxicities Using a New Hepatobiliary Imaging Agent in Mice

  • Ryu, Chong-Kun;Pie, Jae-Eun;Choe, Jae-Gol;Cheon, Joon;Sohn, Jeong-Won;Jurgen Seidel;David S. Paik;Michael V. Green;Chang H. Paik;Kim, Meyoung-Kon
    • 한국환경성돌연변이발암원학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2001
  • We have synthesized $^{99m}$Tc-mercaptoacetyltriglycine (MAG3)-biocytin as a new imaging agent for hepatobiliary scintigraphy. The aim of this study was to evaluate the usefulness of $^{99m}$Tc-MAG3-biocytin scintigraphy in differentiating carbon tetrachloride ( $CCl_4$)-induced hepatotoxicity from $\alpha$-naphthylisothiocyanate (ANIT)-induced cholestasis in mice, which reflecting the differential diagnosis of neonatal jaundice caused by neonatal hepatitis from congenital biliary atresia in humans. Methods: Balb/c mice (female, 20 g, n=4-6) were pretreated with $CCl_4$(0.5 or $1.0m\ell$/kg) and ANIT ($150 or 300 m\ell$/kg) 18 h before scintigraphy. Biochemical and histopathological examinations showed a pattern of typical acute hepatitis (increase of transaminases and hepatocellular necnsis) in $CCl_4$-treated mice and cholestasis (increase of alkaline phosphatase and ${\gamma}$-glutamyltransferase, and biliary hyperplasia) in ANIT-treated mice, respectively, Mice were fasted at least 4 hr prior to the intravenous injection of $^{99m}$Tc-MAG3-biocytin (18.5 MBq/20$\mu\textrm{g}$) in 2% human serum albumin in saline. Scintigraphy was performed with a ${\gamma}$-camera equipped with a 1-mm diameter pin-hole collimator for 30 min and images were acquired every 15 s. We compared the values of physical parameters, such as peak liver/heart ratio ($${\gamma}$_{max}$) and peak ratio time ($t_{max}$) far $^{99m}$Tc-MAG3-biocytin scintigraphy. Results: Scintigraphic parameters of the $CCl_4$-pretreated (0.5 $m\ell$/kg) group showed a 81.9% decrease of r$_{max}$, and 42.2% decrease of $t_{max}$, whereas the ANIT-pretreated ( $150m\ell$/kg) group showed a 53% decrease of $r_{max}$, and 2.36-fold increase of $t_{max}$, (P<0.05). These results demonstrate that the decrease of $r_{max}$ and the shortening of $t_{max}$ are characteristic features for hepatotoxicity, in contrast to the increase of $t_{max}$ and decrease of $r_{max}$ for biliary hyperplasia. Conclusion: $^{99m}$Tc-MAG3-biocytin hepatobiliary scintigraphy can distinguish hepatitis from cholestasis in mice model and may be similarly useful in humans which differentiating the cause of neonatal jaundice in clinical study.cal study.cal study.cal study.

  • PDF