• Title/Summary/Keyword: Chemical control system

Search Result 1,085, Processing Time 0.038 seconds

Development of Multi-Chemical Supply System for Semiconductor Wafer Cleaning Station

  • Chung, Myung-Jin;Song, Young-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1309-1312
    • /
    • 2005
  • A multi-chemical supply system is developed and applied to a wet station, which uses the multi-chemical process in one bath. To control the concentration of two chemicals, control logic of a supply pump is programmed using the programable logic controller (PLC). By using the multi-chemical supply system, wet station with single bath is applied to cleaning process using multi chemicals such as buffed oxide etchant (BOE) and standard clean 1 (SC-1). The concentration of each chemical is measured in the bath to verify the multi-chemical supply system. The control range in the each chemical concentration is measured to 1.33weight% in NH4OH and 0.23weight% in H2O2. The multi-chemical supply system can be movable and usable as an independent module of fixed wet station. By simply midifying the PLC, a multi-chemical supply system can be developed for a wet station.

  • PDF

Factors Affecting the Internal Control System: A Case Study of Chemical Enterprises in Vietnam

  • NGO, Hoang Thanh;NGUYEN, Tung Dao;NGUYEN, Nga Thuy Thi;DAO, Ha Ngoc;VU, Anh Phuong Tran
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.12
    • /
    • pp.371-376
    • /
    • 2021
  • The article analyzes the impact of factors affecting the internal control system of chemical enterprises in Vietnam, providing more empirical evidence on factors affecting the system of internal control. Research data is collected in the form of face-to-face interviews and email interviews with managers and employees working in different positions, managers at all levels, chief accountants, and accountants of 52 chemical enterprises in Vietnam. The survey results collected 310 questionnaires. After eliminating the invalid questionnaires due to many blank cells, the authors chose to use 297 questionnaires. Quantitative research was carried out with SPSS 25 software. Research results show that Business Strategy, Organizational Structure, Organization's perception of the instability of the external environment, and Organizational culture are the factors that positively affect the internal control system of chemical enterprises. This can be explained that, for chemical enterprises, Business strategy, Organizational structure, Organization's perception of the instability of the external environment, and Good organizational culture will positively impact the internal control system of chemical enterprises. Based on the research results, the authors have proposed recommendations to enhance the effectiveness of the internal control system of chemical enterprises in Vietnam, thereby contributing to improving the performance of enterprises in the chemical Vietnamese.

The Development of a remote monitoring and control system for a Fire Protection of Chemical Factory (화학공장의 소방안전을 위한 원격감시 제어시스템 개발)

  • Kim, Hyung-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2009
  • At this study, we are developing a possible control system through remote monitoring for fire protection in various chemical factory facilities. It's possible to do real time confirmation of a normal operation presence of the various equipment installed in a chemical factory through the internet network at a fire fighting head office, an area fire department and a chemical factory situation room using this remote monitoring control system. When occurring, abnormal operation is the remote monitoring control system, which can check this immediately and notify the situation room administrator. After it was tested using developed remote monitoring control system, the remote monitoring for which the internet network was used confirmed possible.

Application of dynamic matrix control (Dynamic Matrix Control의 응용)

  • Moon, Il;Eyo, Young-Koo;Song, Hyung-Keun;Park, Won-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.652-657
    • /
    • 1987
  • The Dynamic Matrix Control(DMC) technique was applied to nonlinear and nonminimum phase system. System model was identified by using Least Square method. Desired output trajectory was prespecified and input suppression parameter was also introduced. It was shown that DMC technique worked with great success in solving both nonminimum phase system and nonlinear system.

  • PDF

Development of Anti-windup Techniques for Cascade Control System (다단제어용 안티 와인드업 기술 개발)

  • Bae, Jeong Eun;Kim, Kyeong Hoon;Chu, Syng Chul;Heo, Jaepil;Lim, Sanghun;Sung, Su Whan
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.430-437
    • /
    • 2020
  • In this research, the anti-windup techniques for the cascade control system are newly developed. Cascade control system has an additional internal feedback control loop to reject disturbances better than the conventional control system. Remarkable difference between the conventional single-loop control system and the cascade control system is the interaction that the controller output saturation of the secondary control loop strongly affects the integral action of the primary control loop. In industry, local back calculation anti-windup method has been mainly used for each controller without considering the interaction between the two controllers. But it cannot eliminate the integral-windup of the primary controller originated from the saturation of the secondary controller output. To solve the problem, the two anti-windup techniques of the cascade conditional integration and the cascade back calculation are proposed in this research by extending the local anti-windup techniques for the single-loop control system to the cascade control system. Simulation confirmed that the proposed methods can effectively remove the integral windup of the primary controller caused by the saturation of the secondary controller output and show good control performances for various types of processes and controllers. If the reliability of the proposed methods is proved through the applications to real processes in the future, they would highly contribute to improving the control performances of the cascade control system in industry.

Development of automatic flow control system based on LabView (LabView를 이용한 자동유량제어 시스템의 개발)

  • Kang, Tae-Won;Kim, Du-Seob;Ann, Sung-Gyu
    • Journal of Engineering Education Research
    • /
    • v.19 no.2
    • /
    • pp.3-7
    • /
    • 2016
  • A flow control system was designed and fabricated to control the flow rate of liquid through the pipe. This control system was composed of hardwares and software, hardwares as controller, gate valve, orifice meter and data aquisition board and software as National instruments Labview program. Control of flow rate was executed by adjusting the pneumatic valve located at the center of pipe line based on the control signal generated by LabView PID control algorithm, which converts analog signal measured by pressure difference of orifice to digital signal to adjust pneumatic valve. For the controller setup Ziegler-Nichols tuning technique was applied and control performances were investigated for not only the disturbance but also the set point changes. Developed system showed good control performances in flow control enough to use as teaching tool of feedback control theory and practice in university, and also as industrial application.

A Simple Method to Make the Quadruple Tank System Near Linear

  • Lee, Jietae;Kyoung, Inhyun;Heo, Jea Pil;Park, YoungSu;Lim, Yugyeong;Kim, Dong Hyun;Lee, Yongjeh;Yang, Dae Ryook
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.767-770
    • /
    • 2017
  • Quadruple tank liquid level systems are popular in testing multivariable control systems for multivariable processes with positive or negative zeros. The liquid level system is nonlinear and it will help to illustrate the robustness of control systems. However, due to nonlinearity, it can be cumbersome to obtain process parameters for testing linear control systems. Perturbation sizes are limited for valid linearized process models, requiring level sensors with high precision. A simple method where the outlet orifice is replaced to a long tube is proposed here. The effluent flow rate becomes proportional to the liquid level due to the friction loss of long tube and the liquid level system shows near linear dynamics. It is applied to the quadruple tank system for easier experiments.

Property Control in a Continuous MMA Polymerization Reactor using EKF based Nonlinear Model Predictive Controller

  • Ahn, Sung-Mo;Park, Myung-June;Rhee, Hyun-Ku
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.468-473
    • /
    • 1998
  • A mathematical model was developed for a continuous re-actor in which free radical polymerization of methyl methacrylate (MMA) occurred. Elementary reactions considered in this study were initiation, propagation, termination, and chain transfers to monomer and solvent. The reactor model took into account the density change of the reactor contents and the gel effect. A control system was designed for a continuous reactor using extended Kalman filter (EKF) based non-linear model predictive controller (NLMPC) to control the conversion and the weight average molecular weight of the polymer product. Control input variables were the jacket inlet temperature and the feed flow rate. For the purpose of validation of the control strategy, on-line digital control experiments were conducted with densitometer and viscometer for the measurement of the polymer properties. Despite the com-plex and nonlinear features of the polymerization reaction system, the EKF based NLMPC performed quite satisfactorily for the property control of the continuous polymerization reactor.

  • PDF

Profile Position Control of Extractive Thermally Coupled Distillation System (추출 열 통합 증류계의 프로필 위치 제어)

  • Cho, Hoon;Choi, Yu-Mi;Lee, Jin-Hong;Cho, Im-Pyo;Han, Myung-Wan
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.815-824
    • /
    • 2012
  • Extractive distillation system can be used when the components to be separated have close boiling points or form azeotropes. Extractive distillation is one of the most important and widely used separation methods in chemical process industry. The main disadvantage of the distillation is its high-energy requirements. Thermally coupled distillation system (TCDS) can provide significant savings in energy consumption and capital cost over the operation of sequences based on conventional distillation column. Despite such advantages of the thermally coupled distillation system, the process is not widely used in industry because control and operation of the column are difficult. In this study, we propose several control schemes for thermally coupled distillation system to overcome the difficulties and make the column stable when the process is confronted with feed disturbances. Profile position control scheme shows best control performance among the proposed control schemes.

Analysis and Suggestions on Current Chemical Management in Korea (국내 화학물질 관리에 대한 현행 법률 분석과 발전방향)

  • Park, Geun Seong;Kim, Hyun Sub;Jeon, Byeong Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.11
    • /
    • pp.650-654
    • /
    • 2017
  • As the amount of chemicals increases, there is a global movement to reorganize the chemical management system. Korea has also reorganized its chemical management system to enact the act on Chemical Control and Registration and Evaluation etc. of chemical substance. However, it is true that there are not enough explanations in domestic workplaces. Therefore, deepening understanding of chemical control act and searched for a complementary point and future development direction. Through the proposed method, chemical control act should be widely adopted and studied both inside and outside the country as a safe chemical management system.