• Title/Summary/Keyword: Chemical Supply System

Search Result 282, Processing Time 0.028 seconds

Study on Simulation of a physical distribution system (물류과정(物流過程)에서 물류비용절감(物流費用節減)을 위한 Simulation 연구(硏究))

  • Kim, Man-Sik
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.3 no.2
    • /
    • pp.41-55
    • /
    • 1977
  • The physical distribution system is composed of all the activities associated with getting products from the factory to the consumer through the firm's channels of distribution. An increasing amount of attention has been recently devoted to the component problems associated with distribution system analysis. This paper analyzes effect of system parameters which are safety factor of depot's stock, limitation of direct supply from shop stock to customer and ordering quantity on the physical distribution cost and the evaluated items by the Simulation. The distribution system simulator views system as being composed of three structural entities, presents a case study of a Chemical manufactures and carried on one year computer running.

  • PDF

A Study on the Trouble of Turbine EHC System by Chloride (염소성분에 의한 터빈 EHC계통 손상에 관한 연구)

  • Kim, Seung Min;Yang, Cheon Gyu;Yoon, Gi Nam;Jung, Jae Won;Shin, Yeul Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.366-372
    • /
    • 2000
  • In a power plant, it is generally accepted that a turbine governor system is necessary to control amount of steam supply toward the turbine system. There are many kinds of trouble at this governor system, which is recognized one of the most sensitive systems in the power plant. Especially we have experienced the internal leakage of motorization oil of servo valve. In the study, we investigated the mechanism of an internal leakage such as erosion by foreign materials and corrosion by chemical reaction between chloric healed oil and motorization oil. A precautionary measures is also performed to help the field service engineers.

  • PDF

Influence of DI Water Pressure and Purified $N_2$Gas on the Inter Level Dielectric-Chemical Mechanical Polishing Process (탈이온수의 압력과 정제된 $N_2$가스가 ILD-CMP 공정에 미치는 영향)

  • 김상용;이우선;서용진;김창일;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.812-816
    • /
    • 2000
  • It is very important to understand the correlation of between inter dielectric(ILD) CMP process and various facility factors supplied to equipment to equipment system. In this paper, the correlation between the various facility factors supplied to CMP equipment system and ILD-CMP process was studied. To prevent the partial over-polishing(edge hot-spot) generated in the wafer edge area during polishing, we analyze various facilities supplied at supply system. With facility shortage of D.I water(DIW) pressure, we introduced an adding purified $N_2$(P$N_2$)gas in polishing head cleaning station for increasing a cleaning effect. DIW pressure and P$N_2$gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. We estimated two factors (DIW pressure and P$N_2$gas) for the improvement of CMP process. Especially, we obtained a uniform planarity in patterned wafer and prohibited more than 90% wafer edge over-polishing. In this study, we acknowledged that facility factors supplied to equipment system played an important role in ILD-CMP process.

  • PDF

Removal of iron oxide scale from feed-water in thermal power plant using superconducting magnetic separation

  • Nishijima, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.2
    • /
    • pp.22-25
    • /
    • 2019
  • The superconducting magnetic separation system has been developing to separate the iron oxide scale from the feed water of the thermal power plant. The accumulation in the boiler lowers the heat exchange rate or in the worst case damages it. For this reason, in order to prevent scale generation, controlling pH and redox potential is employed. However, these methods are not sufficient and then the chemical cleaning is performed regularly. A superconducting magnetic separation system is investigated for removing iron oxide scale in a feed water system. Water supply conditions of the thermal power plant are as follows, flow rate 400 t / h, flow speed 0.2 m / s, pressure 2 MPa, temperature $160-200^{\circ}C$, amount of scale generation 50 - 120 t / 2 years. The main iron oxide scale is magnetite (ferromagnetic substance) and its particle size is several tens ${\mu}m$. As the first step we are considering to introduce the system to the chemical cleaning process of the thermal power plant instead of the thermal power plant itself. The current status of development will be reported.

A Study on the Simple Piped Water Supply System in a Rural Area (일부 농촌지역의 간이 상수도 운영실태와 개선 방안에 관한 조사연구)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 1991
  • This study was carried out for 5 years between 1984 and 1986 and 1989 and 1990. This interviewers visited 292 households to evaluate the perception of the residents using .the. Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 42 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are surmnarized as follows: 1) Approximately 55% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 16 sites and valley water in 26 sites. 3) Considering the type of distribution of the SPWS, there are 28 natural gravity systems and 14 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 74% of the SPWS facilities were used more than ten years. In addition, 40% of residents expressed the need for repairs of old facilities. 5) 48% of the SPWS facilities are neighbored with pollution source. 6) 50% of the maintenance crews were not committed totheir job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 85% of the residents answered that SPWS was convenient and helpful. 8) About 57% of the residents complaind that the amount of daily water supply is not adequate. 9) About 74% of the residents felt that the water quality is high for dringking water and therefore, 52% of the facilities were not properly chlorinated. But in contrast, the biochemical tests indicated that only 28% of the SPWS met the dringking water quality standards. 10) Maintenance cost per a household ranges form 500 to 2, 000Won (1 $ = 700 Won) a month. Most of the cost was to cover the power electric charge. For the effective maintenance and arrangement of the facilities, gorvermental financial support for the maintenance is strongly recommended.

  • PDF

Emission Analysis in Catalytic Converter Adopted Secondary Air Injection System for Cold Start Period (2차 공기 공급 시스템을 채택한 촉매 변환기 내 냉 시동 구간 배기가스 해석)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.46-52
    • /
    • 2010
  • In this paper, emission analysis during cold start period of CVS-75 mode in LPG vehicle was performed to find out proper operating conditions of SAI(Secondary Air Injection) system. In order to meet SULEV target, the simulated emission system had a SAI system as well as a MCC(Manifold Catalytic Converter) and a UCC(Under body Catalytic Converter). Using commercial 1-D code AMESIM, in which 7 step global surface chemical reactions of Langmuir-Hinshelwood type were adopted, transient emission analysis in the exhaust system during cold start period of CVS-75 mode were carried out to figure out the effects of flow rate, duration of supply air on HC, CO, NO emission.

A STUDY ON DEGREASING DETERGENT AND METHOD FOR THE IPP TEST FACILITY

  • Kim Yong-Wook;Lee Jung-Ho;Kang Sun-Il;Kim Sang-Heon;Oh Seung-Hyub
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.262-265
    • /
    • 2004
  • As a cryogen, LOx is a light blue, odorless, transparent liquid. Also it is not shock sensitive and does not decompose. However, it is a strong oxidizer and will vigorously support combustion. Therefore all harmful contaminants (such as grease, oil, fingerprint and organic materials) that could cause malfunctions, fires, or explosions in a oxygen environments must be completely removed prior to the introduction of oxygen. Especially, grease ingredient located inside of the LOx supply line, pipe and PHS (Pneumo-Hydraulic System) part can make drastic chemical reaction with oxygen. Therefore, to protect rapid reaction such as explosion, grease ingredient must be surely eliminated by a regular and irregular degreasing. Study on the availability, effectiveness and selection of degreasing detergents and method is described in this paper, and it will be useful for the construction and management of IPP test facility.

  • PDF

Development of Guidelines for Physical Security Systems of Small-scale Water Supplies (소규모수도시설의 보안시설 설치지침 개발)

  • Kim, Youngil;Yi, Sangjin;Lee, Doojin;Lee, Wontae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.723-730
    • /
    • 2013
  • Due to the event of hazardous chemical injection into a water storage tank in Hongseong, Chungcheongnam-do in 2012, the Korean Ministry of Environment has revised the enforcement rules of the Water Supply and Waterworks Installation Act to install surveillance equipments such as closed-circuit television(CCTV). However, the enforcement rules still do not provide concrete provision for installation of physical security equipments. Thus we studied vulnerability of small-scale water supplies in Korea and developed guidelines for the physical security system of the facilities. The guidelines include selection and recommendation of the physical security approaches and measures to detect, delay and response to the presence of an intruder in small-scale water supplies. The security features include protection utilities(e.g., fencing and fence topping), exterior intrusion detectors and alarms, locks and padlocks, surveillance utilities(e.g., CCTV), and others.

Research for the Chemical Emergency Oxygen Supply and Lighting System for Aircraft Passengers (항공기 승객용 화학적 비상산소 공급 및 조명시스템에 대한 연구)

  • Kim, Young-In
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2022
  • A PSU (passenger service unit) is mounted on passenger seats in a cabin on an aircraft and consists of a crew call lamp, a reading lights, an information display lamp, an emergency oxygen generator, and an emergency oxygen mask. It is a safety device for providing convenience to passengers and providing oxygen to passengers in an emergency. This paper is a study on emergency oxygen supply systems and light systems of aircraft PSUs and a control device was developed to operate the system by analyzing the B767-300 aircraft's PSU circuit diagram. And the temperature generated by the B777-200ER aircraft's emergency oxygen generator was also measured by operating it directly. Through this, precautions for explaining the operation of an oxygen mask in an emergency were described and improvements were presented. Data acquired in these research processes can be used in the future to develop aircraft PSU (passenger service unit) and emergency oxygen generators.

OPTIMAL DESIGN OF BATCH-STORAGE NETWORK APPLICABLE TO SUPPLY CHAIN

  • Yi, Gyeong-beom;Lee, Euy-Soo;Lee, In-Beom
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1859-1864
    • /
    • 2004
  • An effective methodology is reported for the optimal design of multisite batch production/transportation and storage networks under uncertain demand forecasting. We assume that any given storage unit can store one material type which can be purchased from suppliers, internally produced, internally consumed, transported to or from other plant sites and/or sold to customers. We further assume that a storage unit is connected to all processing and transportation stages that consume/produce or move the material to which that storage unit is dedicated. Each processing stage transforms a set of feedstock materials or intermediates into a set of products with constant conversion factors. A batch transportation process can transfer one material or multiple materials at once between plant sites. The objective for optimization is to minimize the probability averaged total cost composed of raw material procurement, processing setup, transportation setup and inventory holding costs as well as the capital costs of processing stages and storage units. A novel production and inventory analysis formulation, the PSW(Periodic Square Wave) model, provides useful expressions for the upper/lower bounds and average level of the storage inventory. The expressions for the Kuhn-Tucker conditions of the optimization problem can be reduced to two sub-problems. The first yields analytical solutions for determining lot sizes while the second is a separable concave minimization network flow subproblem whose solution yields the average material flow rates through the networks for the given demand forecast scenario. The result of this study will contribute to the optimal design and operation of large-scale supply chain system.

  • PDF