• 제목/요약/키워드: Chemical Process Pumps

검색결과 19건 처리시간 0.026초

석유화학 플랜트용 프로세스 펌프의 국산화율 제고 방안에 관한 연구 (A Study on plans for improving localization of process pumps for petrochemical plants)

  • 조원배;문승재;유호선
    • 플랜트 저널
    • /
    • 제5권3호
    • /
    • pp.50-58
    • /
    • 2009
  • In this paper, the present condition for localization of process pumps and the enhancement method of the localization ratio of process pumps for refinery and chemical plant market were studied. The market of plant industry in the world has grown rapidly since 2000. However, the profit of domestic plant EPC compaies cound not have been increased as much as the market scale because they procured most of equipment from overseas. To make remarkable profit of plant EPC companies in the petrochemical industry, localization of equipments is required. Suitable equipment for localization is process pump applied API 610 standard. An purchased amount of pumps from overseas by domestic plant EPC companies in the last two years were 230 billion won. If process pumps are localized then an profit of plant EPC project will increase.

  • PDF

Transient simulation and experiment validation on the opening and closing process of a ball valve

  • Han, Yong;Zhou, Ling;Bai, Ling;Xue, Peng;Lv, Wanning;Shi, Weidong;Huang, Gaoyang
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1674-1685
    • /
    • 2022
  • The ball valve is an important device in the pipeline transportation system of nuclear power plants. Its operational stability and safety directly affect the normal working of nuclear power plants. In this study, the transient numerical simulation of the opening and closing process of a ball valve was conducted on the basis of the flow interruption capability experiment of the ball valve by using the moving mesh method and inlet and outlet variable boundary conditions. The flow rate and pressure difference with time of the opening and closing process of the ball valve were studied. The internal flow characteristics of the ball valve under different relative openings were analyzed in conjunction with the typical back-step flow structure. Results show that the transient numerical results agree well with the experimental results. The internal flow characteristics of the ball valve are similar at the same opening during opening and closing process. At small opening, the spool and outlet channels easily form a back-step flow structure. The disappearance and generation of backflow vortices during opening and closing occur at 85% opening and 75% opening, respectively. With the decrease in opening degree, the difference in vortex core area in the flow channel of the ball valve spool in the opening and closing process gradually appears. The research results provide some reference value for the design and optimization of ball valves.

흐름주입식 바이오센서용 기질용액 자동희석 장치 개발 (Development of an Auto Dilution Unit of Substrate Solutionfor a Flow Injection Type Biosensor)

  • 송대빈;정효석;정대홍;김성태
    • Journal of Biosystems Engineering
    • /
    • 제31권5호
    • /
    • pp.443-448
    • /
    • 2006
  • For development of an on-line monitoring unit of fermentation process, an auto dilution unit based on traditional chemical and biological analytical method was developed and the performance was evaluated. The dilution unit was constructed with two syringe pumps and flow direction change valves and fully automated. Total delivery volume of two pumps using distilled water was measured to confirm the operating stability And diluted concentrations of three substrate solutions (glucose, lactic acid, ethanol) were compared with a standard method with a high performance liquid chromatograph (glucose, lactic acid) and gas chromatograph (ethanol). Relative error values of total delivery volume of the pumps were below 3% and standard deviation values were 0.003 (n=5). Relative error values of diluted concentration of the dilution unit measurements were below 2% with 1/10 of dilution ratio and 70, $80{\mu}{\ell}$ of sample volume conditions for glucose and lactic acid, 1/30 of dilution ratio and $70{\mu}{\ell}$ of sample volume conditions for ethanol, respectively. In case of the ethanol, cause of the evaporative characteristics, the relative error values showed over 5% whole experimental conditions.

MEMS 적용을 위한 폴리실리콘 CMP에서 디싱 감소에 대한 연구 (Dishing Reduction on Polysilicon CMP for MEMS Application)

  • 박성민;정해도
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.376-377
    • /
    • 2006
  • Chemical Mechanical Planarization (CMP) has emerged as an enabling technology for the manufacturing of multi-level metal interconnects used in high-density Integrated Circuits (IC). Recently, multi-level structures have been also widely used m the MEMS device such as micro engines, pressure sensors, micromechanical fluid pumps, micro mirrors and micro lenses. Especially, among the thin films available in IC technologies, polysilicon has probably found the widest range of uses in silicon technology based MEMS. This paper presents the characteristic of polysilicon CMP for multi-level MEMS structures. Two-step CMP process verifies that is possible to decrease dishing amount with two type of slurries characteristics. This approach is attractive because two-step CMP process can be decreased dishing amount considerably more then just one CMP process.

  • PDF

Decontamination of radioactive wastewater by two-staged chemical precipitation

  • Osmanlioglu, Ahmet E.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.886-889
    • /
    • 2018
  • This article presented two-staged chemical precipitation for radioactive wastewater decontamination by using chemical agents. The total amount of radioactive wastewater was $35m^3$, and main radionuclides were Cs-137, Cs-134, and Co-60. Initial radioactivity concentration of the liquid waste was 2264, 17, and 9 Bq/L for Cs-137, Cs-134 and Co-60, respectively. Potassium ferrocyanide, nickel nitrate, and ferrum nitrate were selected as chemical agents at high pH levels 8-10 according to the laboratory jar tests. After the process, radioactivity was precipitated as sludge at the bottom of the tank and decontaminated clean liquid was evaluated depending on discharge limits. By this precipitation method decontamination factors were determined as 66.5, 8.6, and 9 for Cs-137, Cs-134, and Co-60, respectively. By using the potassium ferrocyanide, about 98% of the Cs-137 was removed at pH 9. At the bottom of the tank, radioactive sludge amount from both stages was totally $0.98m^3$. It was transferred by sludge pumps to cementation unit for solidification. By chemical processing, 97.2% of volume reduction was achieved. The potassium ferrocyanide in two-staged precipitation method could be used successfully in large-scale applications for removal of Cs-137, Cs-134, and Co-60.

화학공정용 전동기에 사용된 3D 프린팅 플라스틱 볼베어링의 내화학성 평가 및 현장적용 연구 (Chemical Resistance and Field Trial of 3D-Printed Plastic Ball Bearing Used in Electric Motors for Chemical Processes)

  • 권영준;노명규
    • Tribology and Lubricants
    • /
    • 제39권1호
    • /
    • pp.1-7
    • /
    • 2023
  • Fluid pumps in chemical processes are typically driven by electric motors. Even if the motor is separated from the pump with seals, wear resulting from friction and misalignment can lead to leakage of chemical fluid, causing corrosion in the bearing supporting the motor, and, eventually, failure of the motor. It is thus a standard procedure to replace bearings at regular intervals. In this article, we propose 3D-printed plastic ball bearings for use as an alternative to commercial stainless-steel ball bearings. The plastic bearings are easy to manufacture, require less time to replace, and are chemically resistant. To validate the applicability of the plastic bearings, we first conducted chemical resistance tests. Bearings were immersed in 30 caustic acid and 30 nitric acid for 30 min and 24 h, respectively. The test results showed no corrosive damage to the bearings. A test rig was set up to compare the performance of the plastic bearings with that of the commercially equivalent deep-groove ball bearings. Loading test results showed that the plastic bearings performed as well as the commercial bearing in terms of vibration level and load-handling capability. Finally, a plastic bearing was subjected to a clean-in-place process for three months. It actually outperformed the commercial bearing in terms of chemical resistance. Thus, 3D-printed plastic bearings are a viable alternative to stainless-steel ball bearings.

핵융합 공정주기에서의 생산 계획 최적화 (Mathematical Modeling of Scheduling Problems for the Fusion Fuel Cycle)

  • 이서영;하진국;이인범;이의수
    • Korean Chemical Engineering Research
    • /
    • 제58권4호
    • /
    • pp.596-603
    • /
    • 2020
  • 본 연구에서는 화학공정 최적화에 사용되는 생산계획최적기법을 도입하여 핵융합 공정에서의 삼중수소 재고량을 최소로 유지하는 수학적 모델을 구축하여 최적 운전 시나리오를 도출하였다. 핵융합 발전을 위한 공정 중 연료주기 공정(fuel cycle)은 반응연료인 중수소와 삼중수소를 저장 하고 공급하는 시스템과 핵융합 반응 배가스로부터 이를 회수 및 분리하는 세부 공정들로 구성되어 있다. 이들 공정들은 삼중수소가 방사성 물질이라는 것을 제외하면 대부분 촉매반응과 분리공정으로 이루어져 화공플랜트에 적용된 기술과 유사한 특성이 많아 화학공정에 사용되는 스케줄링 기법을 통해 최적 운전 시나리오를 도출 가능하다. 본 연구에서는 핵융합로의 다양한 장치의 특성을 반영해서, 펌프내부의 삼중수소량을 최소로 하는 최적 재생주기를 구하고, 구해진 최적 재생주기 결과를 반영하여 후단의 트리튬 플랜트에서의 최적 운전 시나리오를 확인해 보았다. 구축된 모델은 실제 토카막 시나리오에 적용되어 ITER 연료주기 내 공정의 연료흐름 및 밸런스 분석에 활용되었다.

스프레이 슬러리 노즐 시스템에서 슬러리 유동이 Cu CMP에 미치는 영향 (Effect of Slurry Flow in Spray Slurry Nozzle System on Cu CMP)

  • 이다솔;정선호;이종우;정진엽;정해도
    • 한국정밀공학회지
    • /
    • 제34권2호
    • /
    • pp.101-106
    • /
    • 2017
  • The chemical mechanical planarization (CMP) process combines the chemical effect of slurry with the mechanical effect of abrasive (slurry)-wafer-pads The slurry delivery system has a notable effect on polishing results, because the slurry distribution is changed by the supply method. Thus, the investigation of slurry pumps and nozzles with regard to the slurry delivery system becomes important. This paper investigated the effect of a centrifugal slurry pump on a spray nozzle system in terms of uniform slurry supply under a rotating copper (Cu) wafer, based on experimental results and computational fluid dynamics (CFD). In conventional tools, the slurry is unevenly and discontinuously supplied to the pad, due to a pulsed flow caused by the peristaltic pump and distributed in a narrow area by the tube nozzle. Adopting the proposed slurry delivery system provides a higher uniformity and lowered shear stress than usual methods. Therefore, the newly developed slurry delivery system can improve the CMP performance.

Cavitation에 의한 슬러지 가용화와 PGA를 이용한 하수고도처리에 관한 연구 (Advanced Wastewater Treatment using Sludge Solubilization by the Cavitation and PGA addition)

  • 김동하
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.449-454
    • /
    • 2008
  • Some pretreatment methods have been proposed to enhance the biodegradability and to shorten the hydrolysis reaction time. By means of efficient pretreatment the suspended solids (SS) can be made of better accessible for the anaerobic bacteria. There are several ways how this can be accomplished, which include biological, mechanical, thermal, and chemical methods. For the sludge solubilization using the cavitation phenomenon, we have tried to develop a pretreatment process consisted of a reactor and pumps. The objectives of this study were to develop a advanced wastewater treatment consisted of IABR and the cavitation with PGA. The most effective removal for organic matter and nutrients were occured when both cavitation pretreatment and ${\gamma}$-PGA were applied at the IABR process. Only small portion of ${\gamma}$-PGA at a rate of 1.38mg/L, was enough to improve sedimentation ability, SS removal efficiencies, and sludge volume reduction. After the sludge solubilization by the cavitation, SCOD increased to 193% and SS decreased to 36%. The removal ratio of BOD was 94.5%, T-N removal ratio was 85.5% and T-P removal ratio was 84.9%. The combination process of the IABR with the cavitation and PGA addition seems to be very effective alternative wastewater treatment process.