• 제목/요약/키워드: Chemical Mechanical Micro machining

검색결과 45건 처리시간 0.017초

전해 프로세스를 이용한 미세축 제작 (Fabrication of Microshafts using Electrochemical Process)

  • 임영모;임형준;김수현
    • 한국정밀공학회지
    • /
    • 제18권3호
    • /
    • pp.169-174
    • /
    • 2001
  • We proposed a new fabrication method using electrochemical process for microshafts. This method is a kind of atomic removal process by chemical reaction. Therefore, it is possible to make thin and long shafts regardless of the stiffness of materials. Because shaping process is simply switched to polishing process by varying process conditions, we can precisely fabricate microshafts with very smooth surface. We also fabricated a very thin shaft with the diameter as small as 10$\mu$m and a microshaft with high aspect ratio.

  • PDF

미세홈 가공시 고압공기분사에 의한 형상정밀도의 향상 (The Improvement of Form Accuracy by High Pressure Air Jet in Slot Grinding)

  • 이석우;이용찬;정해도;최헌종
    • 한국정밀공학회지
    • /
    • 제16권1호통권94호
    • /
    • pp.68-74
    • /
    • 1999
  • One of the recent changes in machining technology is rapid application of micro- and high precision grinding processes. A fine groove generation is necessary for the fabrication of optic, electronic and semiconductor parts, and achieved by chemical or mechanical processes. Slot grinding is very efficient for the generation of micro ordered groove with hard and brittle materials. As slot grinding is continuous, the ground depth become gradually shallow because of wheel wear. The form accuracy become worse from the increase of ground slot width by the loading phenomena at wheel side, results on chipping damage of the workpiece. The experiments achieve to the enhancement of the form accuracy and chipping free of the brittle materials using V shaped cast iron bonded diamond wheels. In this study we focused on the investigation of the effect of the high pressure air jet on the grinding characteristics. As a results, we found that the high pressure air jet is very effective on the reductions of the wheel wear, enhancement of the form accuracy.

  • PDF

Pentacene Thin Film Transistors Fabricated by High-aspect Ratio Metal Shadow Mask

  • Jin, Sung-Hun;Jung, Keum-Dong;Shin, Hyung-Chul;Park, Byung-Gook;Lee, Jong-Duk;Yi, Sang-Min;Chu, Chong-Nam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.881-884
    • /
    • 2004
  • The robust and large-area applicable metal shadow masks with a high aspect ratio more than 20 are fabricated by a combination of micro-electro-discharge machining (${\mu}$-EDM) and electro chemical etching (ECE). After defining S/D contacts using a 100 ${\mu}m$ thick stainless steel shadow mask, the top-contact pentacene TFTs with channel length of 5 ${\mu}m$ showed routinely the results of mobility of 0.498 ${\pm}$ 0.05 $cm^2$/Vsec, current on/off ratio of 1.6 ${times}$ $10^5$, and threshold voltage of 0 V. The straightly defined atomic force microscopy (AFM) images of channel area demonstrated that shadow effects caused by the S/D electrode deposition were negligible. The fabricated pentacene TFTs have an average channel length of 5 ${\pm}$ 0.25 ${\mu}m$.

  • PDF

빔 위치 관련 제어인자가 집속이온빔 패턴 증착공정에 미치는 영향 (The Influence of Parameters Controlling Beam Position On-Sample During Deposition Patterning Process with Focused Ion Beam)

  • 김준현;송춘삼;김윤제
    • 대한기계학회논문집A
    • /
    • 제32권3호
    • /
    • pp.209-216
    • /
    • 2008
  • The application of focused ion beam (FIB) depends on the optimal interaction of the operation parameters between operating parameters which control beam and samples on the stage during the FIB deposition process. This deposition process was investigated systematically in C precursor gas. Under the fine beam conditions (30kV, 40nm beam size, etc), the effect of considered process parameters - dwell time, beam overlap, incident beam angle to tilted surface, minimum frame time and pattern size were investigated from deposition results by the design of experiment. For the process analysis, influence of the parameters on FIB-CVD process was examined with respect to dimensions and constructed shapes of single and multi- patterns. Throughout the single patterning process, optimal conditions were selected. Multi-patterning deposition were presented to show the effect of on-stage parameters. The analysis have provided the sequent beam scan method and the aspect-ratio had the most significant influence for the multi-patterning deposition in the FIB processing. The bitmapped scan method was more efficient than the one-by-one scan type method for obtaining high aspect-ratio (Width/Height > 1) patterns.

표면처리 시간에 따른 임플란트 미세구조의 변화;SLA와 TB 표면 임플란트 (Microstructural Change of Implant Surface conditioned with Tetracycline-HCI;SLA and TB surface implant)

  • 우정아;허익;권영혁;박준봉;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.921-937
    • /
    • 2005
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline- HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml tetracycline - HCl solution for $\frac{1}{2}$ min., 1min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}min.$ respectively in the test group and with no treatment in the control group. The sponge was soaked in every 30 seconds. Then, the specimens were processed for scanning electron microscopic observation. Based upon the analysis of photographs by three dentists who are not related with this study, the results were obtained as follows; 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml tetracycline - HCl solution, in general, test specimens were similar to control. 3. In the $TiO_2blasted$ surfaces, the control specimen showed the rough surface With small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas got wider after 1 minute.