• Title/Summary/Keyword: Chemical Detection

Search Result 1,715, Processing Time 0.033 seconds

Nano-scale Probe Fabrication Using Self-assembly Technique and Application to Detection of Escherichia coli O157:H7

  • Oh, Byung-Keun;Lee, Woochang;Lee, Won-Hong;Park, Jeong-Woo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.227-232
    • /
    • 2003
  • A self-assembled monolayer of protein G was fabricated to develop an immunosensor based on surface plasmon resonance (SPR), thereby improving the performance of the antibodybased biosensor through immobilizing the antibody molecules (lgG). As such, 11-mercaptoundecanoic acid (11-MUA) was adsorbed on a gold (Au) support, while the non-reactive hydrophilic surface was changed through substituting the carboxylic acid group (-COOH) in the 11-MUA molecule using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrocholide (EDAC). The formation of the self-assembled protein G layer on the Au substrate and binding of the antibody and antigen were investigated using SPR spectroscopy, while the surface topographies of the fabricated thin films were analyzed using atomic force microscopy (AFM). A fabricated monoclonal antibody (Mab) layer was applied for detecting E. coli O157:H7. As a result, a linear relationship was achieved between the pathogen concentration and the SPR angle shift, plus the detection limit was enhanced up to 10$^2$ CFU/mL.

Alarm substance Detection and Fright Reaction in Giant Danio (Danio malabaricus)

  • Sung Hwaon Cho
    • Journal of Aquaculture
    • /
    • v.12 no.1
    • /
    • pp.63-69
    • /
    • 1999
  • A series of experiments were conducted to examine on what stimulus giant danio (Danio malabaricus) were mainly responsible for detecting alarm substance. When 0.15 ml alarm substance (10 ppm) was introduced into the tank, fish showed no notable change in swimming pattern. However, the introduction of 1.5 ml alarm substance (100 ppm) could induce fright reaction about in 6 minutes. Further, when 15 ml alarm substance (1,000 ppm) was introduced into the tank, fish showed the following fright reaction in a few seconds; suppressing to feed diet, no swimming, strong chasing, and visual alertness. In detecting alarm substance, fish were mainly depending on the chemical stimulus (nares) rather than the vision stimulus (eyes) because fish detected alarm substance by the chemical cue showed the significantly stronger fright reaction than by the visual cue. The time for fish to show the initial fright reaction after detecting alarm substance by the chemical cue was shorter than by the visual cue. Also after alarm substance was introduced into the tank, olfaction-deprived fish showed significantly weaker fright reaction and less frequency of chasing than the normal fish which detected alarm substance by both olfaction and gustation stimulus. These results indicated that chemical stimulus, especially olfaction might be the primary sensory modality used in the detection of the alarm substance for giant danio.

  • PDF

Propectives of Environmental Colorimetric-Sensors (환경색센서에 관한 기술 전망)

  • Kim, Younghun;Lee, Byunghwan
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.393-399
    • /
    • 2011
  • The electrochemical or optical sensors for environmental pollutants are developed over the past several years. Nowadays, the development of colorimetric sensing is particularly challenging since it requires no equipment at all as color changes can be detected by the naked eye. Visual detection can give immediate qualitative information and is becoming increasingly appreciated in terms of quantitative analysis. In addition, simple colorimetric-sensor have shown useful in the detection, identification, and quantification of volatile organic compounds(VOC) in gas phase or heavy metal ion in aqueous phase. In this review, we investigated the wide applications and some drawbacks of colorimetric-sensors. And thus, we try to suggest the methodologies of development approach of multi-functional and reversible colorimetric-sensor.

Study on the formulations for Topical Skin Protectant against Liquid-Phase Chemical Warfare Agents (액체성 화학작용제의 흡수를 차단하는 피부보호제 제제 설계 연구)

  • Kim, Sang Woong;Seo, Dong Sung;Son, Hong Ha;Yu, Chi Ho;Joe, Hae Eun;Cho, Young
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.210-217
    • /
    • 2022
  • Chemical warfare agents(CWA) such as nerve agents and vesicating agents show lethality by skin contamination. Skin protection, therefore, is one of the top priorities to deal with the growing threat from CWA. In an attempt to develop the most effective topical skin protectant(TSP), candidate substances including PFPE(perfluorinated polyether), PTFE(polytetrafluoroethylene), glycerin, and polysaccharides were evaluated in forms of various formulations against nerve agent simulant DMMP(dimethylmethyl phosphonate) penetration. The protective efficacy of the formulation against DMMP penetration was estimated as the onset time of color change of the KM9 chemical agent detection paper. Based on this study, it was found that several PFPE- and glycerin-based formulations exhibit remarkably superior efficacy as a protective cream. This protective cream is expected to be used as TSP for military application after further research.

Fault Detection and Diagnosis for EVA Production Processes Using AE-SOM (AE-SOM을 이용한 EVA 생산 공정 이상 검출 및 진단)

  • Park, Byeong Eon;Ji, Yumi;Sim, Ye Seul;Lee, Kyu-Hwang;Lee, Ho Kyung
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.408-415
    • /
    • 2020
  • In this study, the AE-SOM method, which combines auto-encoder and self-organizing map, is used to detect and diagnose faults in EVA production process. Then, the fault propagation pathways are identified using Granger causality test. One year and seven months of operation data were obtained to detect faults of the process, and the process variables of the autoclave reactor are mainly analyzed. In the data pretreatment process, the data are standardized and 200 samples of each grade are randomly chosen to obtain a fault detection model. After that, the best matching unit (BMU) of each grade is confirmed by applying AE-SOM. The faults are determined based on each BMU. When a fault is found, the most causative variable of the fault is identified by using a contribution plot, and the fault propagation pathway is identified by Granger causality test. The prognostic of the two shutdowns is detected, and the fault propagation pathway caused by the faulty variable was analyzed.

Characterization of the Surface Contribution to Fluorescence Correlation Spectroscopy Measurements

  • Chowdhury, Salina A.;Lim, Man-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.583-589
    • /
    • 2011
  • Fluorescence correlation spectroscopy (FCS) is a sophisticated and an accurate analytical technique used to study the diffusion of molecules in a solution at the single-molecule level. FCS is strongly affected by many factors such as the stability of the excitation power, photochemical processes, mismatch between the refractive indices, and variations in the cover glass thickness. We have studied FCS near the surface of a cover glass by using rhodamine 123 as a fluorescent probe and have observed that the surface has a strong influence on the measurements. The temporal autocorrelation of FCS decays with two characteristic times when the confocal detection volume is positioned near the surface of the cover glass. As the position of the detection volume is moved away from the surface, the FCS autocorrelation becomes one-component decaying; the characteristic time of the decay is the same as the faster-decaying component in the FCS autocorrelation near the surface. This observation suggests that the faster component can be attributed to the free diffusion of the probe molecules in the solution, while the slow component has its origin from the interaction between the probe molecules and the surface. We have characterized the surface contribution to the FCS measurements near the surface by changing the position of the detection volume relative to the surface. The influence of the surface on the diffusion of the probe molecules was monitored by changing the chemical properties of the surface. The surface contribution to the temporal autocorrelation of the FCS strongly depends on the chemical nature of the surface. The hydrophobicity of the surface is a major factor determining the surface influence on the free diffusion of the probe molecules near the surface.

A Study on the Simultaneous Analysis of Fat-Soluble Vitamins in Food Stuffs and Vitamin Products by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 식품 및 비타민 제제중의 지용성 비타민의 동시 분석에 관한 연구)

  • Poongzag Kim;Chong-Hyeak Kim
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.46-54
    • /
    • 1989
  • The extraction method and quantitative analysis for the fat-soluble vitamins present in food stuffs and vitamin products have been investigated. The simultaneous separation and analysis of the vitamins by reverse phase high performance liquid chromatographic method was conducted using an isocratic elution with methanol : water (95 : 5) eluent on a Novapak $C_{18}$ column. The detection of vitamins was achieved by a variable wavelength UV detector. To improve the detection sensitivity detection wavelengths were set at the highest absorption bands such as 330, 265, 285, and 290nm for the respective vitamins. The analysis for the fat-soluble vitamins was finished within 40 minutes. Alkaline hydrolysis and enzymatic hydrolysis were investigated for the sample preparation; and liquid-liquid extraction and liquid-solid extraction were attempted for the extraction of vitamins. Both hydrolysis methods were turned out to be appropriate for the analysis for vitamins A, D, and E, while for the analysis of vitamin K the enzymatic hydrolysis method demonstrated better results. Diethyl ether, pentane, and n-hexane were found to give higher recovery for the liquid-liquid extraction and silica cartridge for the liquid-solid extraction.

  • PDF

Detection of Molecules using the Nanoparticle Arrays (나노입자 배열을 이용한 분자 검출)

  • Ha, Dong-Han;Kim, Sang-Hun;Yun, Yong-Ju;Park, Hyung-Ju;Yun, Wan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1617-1622
    • /
    • 2008
  • We report a new molecular detection process which measures the changes in the plasmon resonance peaks of periodic Au nanoparticle arrays fabricated using the electron beam lithography. As the Au nanoparticle arrays are modified by the chemical reaction in solutions having various concentrations of a target molecule, both the position and intensity of the plasmon peak change in proportion to the concentration of the target molecule. We expect that the process developed in this work can be employed for fine tuning of the plasmon peak wavelength and also for the optical detection of various kinds of molecules. Moreover, this method may improve the measurement accuracy compared with existing approaches that use only one change (peak wavelength or peak intensity) as a readout value for the molecular detection.

  • PDF