• Title/Summary/Keyword: Check angle

Search Result 221, Processing Time 0.028 seconds

Analysis on Wood Quality, Geometry Factor, and Their Effects on Lathe Check of Samama (Anthocephalus macrophyllus) Veneer

  • Cahyono, Tekat Dwi;Wahyudi, Imam;Priadi, Trisna;Febrianto, Fauzi;Bahtiar, Effendi Tri;Novriyanti, Eka
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.828-841
    • /
    • 2016
  • Relatively little information is available regarding the correlation between wood and veneer quality, especially for Samama wood, an endemic wood species in eastern Indonesia. This study addresses the quality of 8 years old Samama wood and its effect on the veneer quality. Samama wood quality was determined by evaluating its specific gravity, moisture content, fiber dimensions, and microfibril angle from pith toward bark. Meanwhile, veneer quality was assessed by examining veneer thickness and lathe check characteristics. Geometry factor model was constructed to elaborate the quantities of lathe check from pith toward bark. Results show that fair variations of veneer thickness, ranging from 1.5 mm to 3.0 mm, could be obtained from Samama wood. The quantity, depth, and length of lathe check were noticeably decreasing toward bark. Further, in the same manufacturing process, geometry factor was determined as the dominant factor over other wood properties in affecting the frequency of lathe checks from pith towards bark. These facts should be put into consideration in producing veneer from Samama wood. Moreover, these results enlighten the potential of Samama wood as plywood and other excellent veneer-based products.

Nonlinear finite element analysis of top- and seat-angle with double web-angle connections

  • Kishi, N.;Ahmed, A.;Yabuki, N.;Chen, W.F.
    • Structural Engineering and Mechanics
    • /
    • v.12 no.2
    • /
    • pp.201-214
    • /
    • 2001
  • Four finite element (FE) models are examined to find the one that best estimates moment-rotation characteristics of top- and seat-angle with double web-angle connections. To efficiently simulate the real behavior of connections, finite element analyses are performed with following considerations: 1) all components of connection (beam, column, angles and bolts) are discretized by eight-node solid elements; 2) shapes of bolt shank, head, and nut are precisely taken into account in modeling; and 3) contact surface algorithm is applied as boundary condition. To improve accuracy in predicting moment-rotation behavior of a connection, bolt pretension is introduced before the corresponding connection moment being surcharged. The experimental results are used to investigate the applicability of FE method and to check the performance of three-parameter power model by making comparison among their moment-rotation behaviors and by assessment of deformation and stress distribution patterns at the final stage of loading. This research exposes two important features: (1) the FE method has tremendous potential for connection modeling for both monotonic and cyclic loading; and (2) the power model is able to predict moment-rotation characteristics of semi-rigid connections with acceptable accuracy.

Optical configurtion and fabriation for a reflective display using an antiferroelectric liquid crystal cell (AFLC 셀을 이용한 반사형 LCD의 설계 및 제작)

  • 김성철;박원상;이서헌;황용석;이기동;윤태훈;김재창
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.235-239
    • /
    • 2001
  • In this paper, we propose an optical configuration of a reflective AFLC display mode using a half-wave AFLC cell in which inplane tilt angle is $22.5^{\circ}C$. To check the validity of our design, we fabricate a reflective half-wave AFLC cell of which the in-plane tilt angle is $24.9^{\circ}C$, and measure viewing angle and visible spectra characteristics. In the results, the half-wave AFLC cell in the reflective configuration exhibits wide viewing-angle as well as high brightness and contrast. trast.

  • PDF

A Development of a Shape Optimization Design Techniques for the Diagrid Tapered Tall-Building (테이퍼드 다이아그리드 초고층 구조물의 형상 최적설계기법 개발)

  • Han, Sang-Eul;Lee, Han-Joo;Ryu, Jong-Hye;Jeong, So-Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.349-356
    • /
    • 2011
  • In this paper, the optimal diagrid angle of atypical tall buildings has been found using diagrid optimization technique which is based on parametric algorithm. A diagrid is a diagonal grid which can be seen among atypical tall buildings and structures which effectively resist horizontal and vertical direction loads. Therefore, it is also the objective of this studyto find the maximum stiffness of atypical tall buildings by optimizing diagrid angle. Moreover, this study touches on both cylindrical and tapered off cylindrical structures, as shown in the examples to check the compatibility of optimum diagrid angle, which effectively resists horizontal deformation on top by optimization algorithm.

Review of Regulation for Rollover Test and Evaluation of Safety for Buses by using Simulation of Multi-body Dynamics (다물체 동역학 시뮬레이션을 통한 버스의 전복 시험 규정과 안전성 평가에 관한 고찰)

  • Park, Seung Woon;Choi, Yo Han;Lee, Chul-Hee
    • Journal of Drive and Control
    • /
    • v.19 no.3
    • /
    • pp.39-46
    • /
    • 2022
  • In South Korea, to evaluate the rollover safety of domestic vehicles, the maximum slope angle of the vehicle is specified, which is verified by the rollover safety test of driving vehicles. However, the domestic rollover safety test is not suitable for buses, because the small amount of static stability factor (SSF) will invalidate the rollover experimental equation due to the high center of mass position of buses. To solve the above problems, a dynamic model of the bus is prepared with assumptions of mass and suspension spring properties. Subsequently, the maximum slope angle of the model was computed by using the simulation of multi-body dynamics, and the result was compared with actual test results to validate the dynamics model. Also, the rollover Fishhook (roll stability) test was conducted in the simulation for driving model. During the simulation, roll angle and roll rate were calculated to check if a rollover occurred. Through the rollover simulation of buses, the domestically regulated formula for rollover safety and the procedure of rollover test for driving vehicles are evaluated. The conclusion is that the present regulation of rollover test should be reconsidered for buses to ensure to get the valid results for rollover safety.

A STUDY ON THE DIFFERENCE OF THE SAGITTAL CONDYLAR GUIDANCES BY MEASURING METHODS (측정방법에 따른 시상과로 경사각의 차이에 관한 연구)

  • Lew, Jin-Young;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.77-86
    • /
    • 1993
  • The purpose of this study was to compare the sagittal condylar guidance obtained by the graphic method(pantographic tracing) with that produced by the positional method(check-bite). Ten adults who had normal occlusion and were free of TMJ dysfunction were selected, and the clutches were constructed. At first pantographic survey was performed and the articulator was adjusted with each pantographic recording. And then three protrusive check-bite were taken on the subjects using the polyether$(Lamitec^{(R)})$ on the buccal side of the posterior teeth without the interocclusal record method and the vericheck method was performed with each protrusive check-bite. Sagittal condylar guidances obtained by using the pantograph and Vericheck were compared and analyzed statistically. The results were as follows: 1. The average condylar guidance ankle at 4mm and 7mm from centric relation point on the pantograph $(35.9{\pm}1.10^{\circ},\;32.4{\pm}1.55^{\circ})$ was statisccally significant(P<0.01). 2. The average condylar guidance angle of the Vericheck was $27.0{\pm}3.43^{\circ}$. 3. The comparison of the right and left was not statistically significant in all group(P>0.05). 4. The comparison of pantograph and Vericheck was statistically significant in the right and left(P<0.001).

  • PDF

FEASIBILITY ON GENERATING STEREO MOSAIC IMAGE

  • Noh, Myoung-Jong;Lee, Sung-Hun;Cho, Woo-Sug
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.201-204
    • /
    • 2005
  • Recently, the generation of panoramic images and high quality mosaic images from video sequences has been attempted by a variety of investigations. Among a matter of investigation, in this paper, left and right stereo mosaic image generation utilizing airborne-video sequence images is focused upon. The stereo mosaic image is generated by creating left and right mosaic image which is generated by front and rear slit having different viewing angle in consecutive video frame images. The generation of stereo mosaic image proposed in this paper consists of several processes: camera parameter estimation for each video frame image, rectification, slicing, motion parallax elimination and image mosaicking. However it is necessary to check the feasibility on generating stereo mosaic image as explained processes. Therefore, in this paper, we performed the feasibility test on generating stereo mosaic image using video frame images. In doing so, anaglyphic image for stereo mosaic images is generated and tested for feasibility check.

  • PDF

A Study about Grid-Connected Wind Power Generation System (계통연계 풍력발전 시스템에 관한 연구)

  • Cho, Moon-Taek;Hwang, Lak-Hun;Kim, Young-Soo;Na, Seung-Kwon;Song, Ho-Bin;Kim, Yeal-Chung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1238-1240
    • /
    • 2007
  • The wind force development system is applying variableness inside system recently. High-capacity system performs blade pitch check and main point check, but because pitch angle is fixed in case of capacity system, development efficiency drops. Must do to achieve variableness inside control about change of manners to be acted in maximum electric power point hereupon. Treatise that see hereupon proves this theoretically, and proved validity through 400 [W] experiments.

  • PDF

Design of Infrared Angular Sensor for Human Joint Angle (관절각 측정을 위한 적외선 각도 센서 연구)

  • Oh, Han-Byeol;Kim, Ji-Sun;Kim, A-Hee;Goh, Bong-Jun;Kim, Jun-Sik;Lee, Eun-Suk;Choi, Ju-Hyeon;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.792-798
    • /
    • 2015
  • Joint angle generally can be measured to check the recovery process in rehabilitation field. This paper suggests to measure joint angle with Infrared sensor based on triangulation principle. We performed various experiments to find the optimal condition of the sensor’s attached distance, height, and angle. The results were compared with commercial goniometer for accuracy. The proposed infrared joint angle sensor can be effectively used in rehabilitation and sport science fields.

An Analysis of Muscular Activity of the Long and Short Heads of Biceps Brachii Muscle According to the Elbow Flexion Angle (위팔두갈래근의 긴갈래와 짧은갈래의 팔굽관절 굽힘 각도에 따른 근활성도 분석)

  • Kim, Jeong-Wook;Park, Min-Chull
    • PNF and Movement
    • /
    • v.18 no.1
    • /
    • pp.127-132
    • /
    • 2020
  • Purpose: This study aimed to investigate the impact of resistance on the muscle activities of the long and short heads of the biceps brachii, according to the elbow angle in supination, and the difference in muscle activity between the long and the short heads. Methods: This study was conducted with 22 men in their 20s who voluntarily agreed to participate. With the glenohumeral joint neutral in a position of supination, the elbow angle was randomly moved to 0°, 30°, 60°, and 90°. Using an 8-channel surface EMG while the participants held a 2-kg. dumbbell, the muscle activities of the long and the short heads of the biceps brachii were measured. The measured data were statistically processed using SPSS for Windows 12.0. For the activities of the short and the long heads according to the angle, a one-way ANOVA was conducted, and subsequently, to check the results of an analysis of the difference between groups, an LSD post-hoc test was conducted. An independent t-test was used to compare the activities of the long head and the short head according to the angles. Results: The analysis of the impact of the load of the dumbbell at each elbow angle on the muscle activities of the long and short heads of the biceps brachii revealed significant differences in both heads (p < 0.05). The result of the post-hoc analysis showed significant differences in both heads at angles between 0° and 30°, between 0° and 60°, and between 0° and 90°. Analysis of the impact of the load of the dumbbell in supination on the muscle activities of the long and short heads showed a significant difference at the angle between 0° and 30° (p < 0.05). Conclusion: The long head of the biceps brachii mainly acts in supination; however, in supination at elbow-bending angles of 60° and 90°, there was no difference in muscle activity between the short head and the long head.