• Title/Summary/Keyword: Charging current

Search Result 590, Processing Time 0.031 seconds

Hydrogen Embrittlement Evaluation of Subsurface Zone in 590DP Steel by Micro-Vickers Hardness Measurement (미소경도 측정에 의한 590DP강 Subsurface Zone 내 수소취성 평가)

  • Choi, Jong-Un;Park, Jae-Woo;Kang, Kae-Myung
    • Korean Journal of Materials Research
    • /
    • v.21 no.11
    • /
    • pp.581-586
    • /
    • 2011
  • This study describes a hydrogen embrittlement evaluation of the subsurface zone in 590DP steel by micro-Vickers hardness measurement. The 590DP steel was designed to use in high-strength thin steel sheets as automotive materials. The test specimens were fabricated to 5 series varying the chemical composition through the process of casting and rolling. Electrochemical hydrogen charging was conducted on each specimen with varying current densities and charging times. The relationship between the embrittlement and hydrogen charging conditions was established by investigating the metallography. The micro-Vickers hardness was measured to evaluate the hydrogen embrittlement of the subsurface zone in addition to the microscopic investigation. The micro-Vickers hardness increased with the charging time at the surface. However, the changing ratio and maximum variation of hardness with depth were nearly the same value for each test specimen under the current density of 150 mA/$cm^2$ and charging time of 50 hours. Consequently, it appears that hydrogen embrittlement in 590DP steel can be evaluated by micro-Vickers hardness measurement.

Design of a Bidirectional Converter for Battery Charging, Discharging and Zero-voltage Control (배터리 충, 방전 및 영전압 제어를 위한 양방향 컨버터 설계)

  • Choi, Jae-Hyuck;Kwon, Hyuk-Jin;Kwon, Jae-Hyun;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.431-437
    • /
    • 2022
  • This study proposes a converter that makes battery charging, discharging, and zero voltage control possible. The proposed topology consists of an LLC converter and a half-bridge inverter, and all power semiconductor devices are applied Si-MOSFETs. The topology is designed with an LLC switching frequency of 100 kHz, a half-bridge inverter switching frequency of 50 kHz, and a battery voltage of 5 V. The advantages of the charging/discharging operation of the 5 V battery voltage and the zero voltage control of the battery are verified. In addition, by using a two-stage topology, the battery can be charged, discharged through current control, and discharged to zero voltage. With the proposed topology, the current can be maintained even when the battery voltage drops to zero.

Power stage for Contact-less Induction Charging (비접촉식 충전기의 전력 전달부 설계)

  • 이민철;최배근;홍영욱;조규형
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2939-2942
    • /
    • 2003
  • A new contactless Li-ion battery charging system was proposed. The conventional methods for charging Li-ion battery have some weak points. For example, there can be a contact failure, a poor waterproof, and a difficulty to standardize the battery charging systems. The new proposed system can overcome these weak points. The new charging system is composed of power transfer part and data transfer part. This paper focuses on the power transfer part for contactless battery charging. The power stage is mainly composed of PPRC(Push-pull Parallel Resonant Converter) and flyback converter. The new method of chaging Li-ion battery was proposed and PPRC + flyback-boost topology was analyzed. The proposed toplogy was tested under the constant voltage control and the constant current control which are adequate for charging Li-ion battery.

  • PDF

Analysis of Time-Dependent Behavior of Plasma Sheath using Ion Fluid Model (이온유체방정식을 이용한 Plasma Sheath 시변 해석)

  • Lee, Ho-Jun;Lee, Hae-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2173-2178
    • /
    • 2007
  • Dynamics of plasma sheath was analyzed using simple ion fluid model with poison equation. Incident ion current, energy, potential distribution and space charge density profile were calculated as a function of time. The effects of initial floating sheath on the evolution of biased sheath were compared with ideal matrix sheath. The effects of finite rising time of pulse bias voltage on the ion current and energy was studied. The influence of surface charging on the evolution of sheath was also investigated

The study of self excited type brushless charging generator, it has generated region (발전영역을 갖은 자동형 brushless 충전발전기에 관한 연구)

  • Byung In Oh
    • 전기의세계
    • /
    • v.18 no.4
    • /
    • pp.7-15
    • /
    • 1969
  • In this method the condenser excite winding has the phase angle of 90 electrical degree, with the load winding in stator. The condenser excite wing is connected with the condenser while the load winding is with the full rectifer. Direct and quardrature axis components of rotating field winding are composed, of balanced two phase winding, and each one of them is connected with half wave rectifiers. Initically, small amount of lead current can be induced at the condenser excite winding by residual magnetism of rotor. The induced lead current forces the rotating field winding to be excited by synchronous alternating magnetic field. The speed electromotive force, there for, induced in rotating field winding shall electro magnetize the rotating field pole by rotating half wave rectifiers. In the case of the charging generator directly coupled with engines at the operation of wide range speed, the generated region, such as vehicles, aircraft, ships etc, is occured. In conclusion, we can take the advantage of, omitting of voltage regurator and current limiter for charging load and reducing the consumption of fuel using the generated region which can be devided in to Impossible generated region, Generated region, and suspension generated region.

  • PDF

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway (전철 지중배전선로의 충전전류보상에 관한 연구)

  • Kim, Yang-Su;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

Study of Constant Current-Constant Voltage Output Wireless Charging System Based on Compound Topologies

  • Tan, Linlin;Pan, Shulei;Xu, Changfu;Yan, Changxin;Liu, Han;Huang, Xueliang
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1109-1116
    • /
    • 2017
  • Wireless power transfer (WPT) technology has the advantages of intelligence and facilitation. This paper designs a WPT system applied to battery charging and provides a strategy which switches from the constant current (CC) charging mode to constant voltage (CV) charging mode. The LCL-LCL topology is used to realize the CC output, while the LCL-S (series compensation) topology is used to realize the CV output. The main factor affecting the output characteristics is extracted by analyzing the two topologies above. Based on the main factor, this paper puts forward a modified way to design the system. In addition, on-line monitors for the battery and switches are placed at receiving side, which avoids the need for introducing an information interaction module into the system. Therefore, the complexity of the controlling system is reduced. Finally, simulation and experimental analyses are carried out to verify the correctness of the compound topologies.

Characteristics of Variable Wireless Charging System Applying Superconducting Coils (초전도 코일을 적용한 무선 충전시스템 특성)

  • Jeong, In-Sung;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.804-808
    • /
    • 2018
  • Interest in wireless power transfer (WPT) has been growing recently due to the rapid increase in the use of electronic devices. Wireless charging systems are currently being applied to mobile phones and many studies are being conducted to apply wireless charging systems to various devices. The current wireless charging systems are capable of 1:1 charging. For wireless charging, when the devices with the same resonance frequency are present in the vicinity, the charging efficiency may be significantly lowered due to frequency interference or the wireless charging systems may stop operating. In this paper, variable capacitors were applied to a superconducting WPT system to solve the frequency interference among multiple devices with the same frequency. When a wireless charging system was performing 1:1 operation, the frequency of the other devices was varied using variable capacitors. As a result, it was confirmed that the highly efficient WPT is possible without frequency interference even when multiple receivers are present.

Power Control of Three Phase PWM Converter for Small-scale Wind Power using Flux Weakening Control in Over Wind Speed Region (과풍속 영역에서의 약계자 제어를 이용한 풍력발전용 3상 PWM 컨버터의 출력제어)

  • Ku, Hyun-Keun;Kim, Jae-Heung;Lee, Hyung-Uk;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • This paper proposes the battery charging algorithm for small-scale wind power generator using three phase PWM converter. it is impossible to control output power of the converter in over wind speed region since back EMF of PMSG is higer than battery voltage. Therefore, battery charging algorithm is proposed to expand battery charging over wind speed region. The suggested method is using the q-axis current for battery charging in the rated wind speed region. In the over wind speed region after it lower back EMF of PMSG using d-axis current it can control output power of the converter. The validity of the proposed algorithm are verified by experiments.