• 제목/요약/키워드: Charging air pressure

검색결과 51건 처리시간 0.035초

과급 LPLi 엔진의 공연비 변화에 따른 출력성능 및 배기특성에 관한 연구 (The Study of Engine Output and Emission Characteristics according to Air Fuel Ratio far a Supercharged LPLi Engine)

  • 류재덕;윤용원;이기형;이창식
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.77-84
    • /
    • 2002
  • For the purpose of obtaining a fundamental data which is needed to develope the port injection type charged LPLi engine system, we manufactured intake port injection system of liquid charging LPG and modified heavy duty single cylinder LPLi engine from heavy duty diesel engine. Engine output and emission characteristics were analyzed under variable air/fuel ratio and charging pressure. Since LPG is consisted of propane and butane, we investigated combustion characteristics using this two kinds of fuel. From the result of charging engine performance test, engine torque increase about 30% ∼ 40% with 0.3bar charging pressure. In low speed condition, as charging pressure increase, combustion stability improve ill lean bum condition, but, in high speed condition, combustion stability make worse in lean bum condition. We know that engine output decreased rapidly from the condition of air excess ratio 1.3. In addition, we measured emission characteristics under the lean bum and charging condition. From this experiment, we found that CO emission is out of the question in the range from stiochiometric to lean burn and charging condition, but charging pressure has influence on HC emission.

확산형 흡수식 냉장고에서 작동매체 충진조건이 증발온도에 미치는 영향 (Effects of Charging Conditions on Evaporating Temperature for Diffusion Absorption Refrigerator)

  • 김선창;김영률;백종현;박승상
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.828-834
    • /
    • 2003
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (hydrogen or helium). In this study, experimental investigations have been carried out to examine the effects of charging conditions of working fluids on the evaporating temperature for diffusion absorption refrigerator. Experimental parameters considered in the present experiments are charging concentration, solution charge and system pressure determined by auxiliary gas charged. As a result, in the charging condition of 35% of concentration and 20 kg$_{f}$cm$^2$ of system pressure, the system has the lowest evaporating temperature. It was found that there exists a minimum value of solution charge for the operation of diffusion absorption refrigerator.r.

가변체적내의 압축공기 충진 및 방출특성연구 (A Study on Chargin and Discharging Characteristics of Variable Volume with Compressed Air)

  • 김동수;김형의;박재범;강보식;성백주
    • 한국정밀공학회지
    • /
    • 제12권11호
    • /
    • pp.125-131
    • /
    • 1995
  • Pneumatic System has been mainly used as main equipment for actuation and control of fluid force in manufacturing industry. For velocity control of piston, meter-out restriction method is used in many cases. In this systems, meter-out restriction method is adopted for analysing the Dynamic Charging and Discharging Process which is Variable Volume Chamber. Experiments has been conducted for different supply pressure condition. As a experimental result, charge side chamber pressure rises to supply pressure rapidily and discharge side chamber pressure decreases. Also, when the air in the cylinder is discharged, tempdrature of air decreases steeply. Restriction of the Cylinder sometimes freeze and it dose not function. The result will be useful for the analysis of pneumatic system.

  • PDF

CNG버스 내압용기 사용 및 안전관리 실태 분석 (Analysis on Actual Condition of Usage and Safety Management for CNG Pressure Vessel in Bus)

  • 김의수
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.6-14
    • /
    • 2019
  • There are about 38,977 CNG cars and 247 natural gas vehicle charging stations in operation in order to improve the urban air environment. With the introduction of natural gas vehicles, the atmospheric environment, which was the main cause of air pollution in the metropolitan area, was remarkably improved. However, unlike these positive effects, CNG bus accidents, which occurred more than 10 times since 2005, have caused concern among the majority of citizens using public transportation. It is necessary to make a judgment on the feasibility and future direction of CNG pressure vessel safety management that can safeguard the safety of CNG pressure vessel at the time of starting. In this study, we investigates production and use of CNG vessel, the current status of safety management of CNG bus transportation companies & charging stations and then proposes measures to prevent accident recurrence and safety management based on the actual situation investigation and analysis.

Effects of the Charging Mass of Working Fluid on the Thermal Performance of Heat Pipe with Axially Grooved Wick

  • Suh, Jeong-Se;Kang, Chang-Ho;Hong, Jung-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.79-86
    • /
    • 2004
  • An analytical and experimental study has been conducted to determine the optimal charging mass of working fluid for the maximum heat transport capacity of heat pipe with axially grooved wick. When the heat pipe is operated in a steady state, the liquid-vapor meniscus recession of working fluid to the bottom of groove is occurred in the evaporator region. In this work, the optimal charging mass of working fluid was obtained by considering the meniscus recession from the axial variation of capillary pressure, the radius of curvature and wetting angle of meniscus of liquid-vapor interface. Experimental results were also obtained by varying the charging mass of working fluid within a heat pipe, and presented for the trend of maximum heat transport capacity corresponding to the operating temperature and the elevation of heat pipe. Finally, the analytical results of the optimal charging mass of working fluid were compared with those from the experiment, both of which were in good agreement with each other.

직분식 예혼합 압축착화 디젤엔진의 운전조건과 연료조성에 따른 연소 및 배기 특성 (The Characteristics of Combustion and Exhaust Emission according to Operating Condition and Fuel Composition in a Direct Injection Type HCCI Diesel Engine)

  • 이기형;류재덕;이창식
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.10-16
    • /
    • 2004
  • The Homogeneous Charge Compression Ignition (HCCI) engine has advantage for reducing the NOx and P.M. simultaneously. Therefore, HCCI engine is receiving attention as a low emission diesel engine concept. This study was carried out to investigate the characteristics of combustion and exhaust emission for operating conditions in a direct injection type of HCCI engines such as supercharged and naturally aspirated using diesel fuel and additive. From the experimental result, we found that cool flame was always appeared and also it was difficult to control combustion characteristics by changing the injection timing in HCCI. In addition, at the lean air-fuel ratio and high speed range, it was observed that charging air pressure, additive or increasing intake air temperature is effective to increase combustion performance and reduce exhaust emission. We concluded that chemical reaction by the increasing intake air temperature or additive without physical improvement has limitation for reduction of exhaust emission.

자동차용 정전 필터의 미세 입자 포집 특성 (Collection Performance of an Electret Cabin Air Filter for Fine Particles)

  • 지준호;강석훈;김동철;황정호;윤웅섭;배귀남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.85-90
    • /
    • 2001
  • This work presents experimental results of filter media test by using particles from $0.02\;to\;0.6{\mu}m$ in diameter and by applying different charging states. In order to investigate the electret filter performance, the collection efficiency and the pressure drop of filter were measured. The face velocities of test filters varied from 2.4 to 20.4 cm/s. Another experiment setup for the cartridge cabin air filter was used to get an collection efficiency in submicron region. After charging level of electret filter severely decreased, the change of collection efficiency was verified. Experimental results show that the reliability of electret filters can be poor in some conditions.

  • PDF

재생기 및 냉각기가 VM열펌프의 냉방성능에 미치는 영향 (Effects of regenerator and cooler on the cooling performance of a vuilleumier cycle heat pump)

  • 이건태;강병하;유호선;이재헌
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.333-342
    • /
    • 1997
  • An experimental study has been carried out to investigate the effects of the combination of the different wire mesh number in a regenerator and the tube number in a cooler on the cooling performance of a Vuilleumier cycle heat pump. Effects of operating conditions, such as charging pressure, operating speed, and heat input, on the cooling performance are also studied. The experimental results obtained indicate that the cooling performance could be improved with the proper combination of different wire meshes in a regenerator. More tubes in a cooler are desirable for better cooling performance. It is also found that the cooling capacity is enhanced, whereas COP is reduced with an increase in the heater tube temperature and the revolution speed. Both the cooling capacity and COP are incereased with a higher charging pressure.

  • PDF

냉매 내 공기혼입에 따른 에어컨 시스템의 냉각성능 저하 (Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제34권6호
    • /
    • pp.470-475
    • /
    • 2009
  • This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.

열교환기 형상에 따른 분리형 히트파이프 성능 비교 (Separate type heat pipe performance comparison by the heat exchanger shapes)

  • 전성택;조진표
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.723-729
    • /
    • 2016
  • 본 연구에서는 핀-관형 히트파이프와 평행류형 히트파이프 제작하여 시험하였으며 분리형 히트파이프의 작동유체의 충진량은 40~60(% vol.), 풍량은 300~1,400 사이에서 변화시켜가며 온도교환 효율, 열회수량, 공기측 압력강하를 비교하였다. 온도교환 효율은 두 종류의 히트파이프 모든 경우에서 저 풍량에서는 작동유체 충진량이 40(%vol.)일 때가 가장 높았으며 풍량이 증가함에 따라 최대 효율을 가지는 작동유체 충진량이 다름을 알 수 있었고, 환기량이 작을수록 온도교환 효율이 높게 나타났다. 평행류형 히트파이프 60(%vol.)의 실험결과에서 보는 것과 같이 작동 유체를 너무 많이 충진하게 되면 오히려 낮은 온도교환 효율을 보이는데 이는 관벽의 액막이 두터워지면서 열전달 효과를 악화시킨 결과로 최적 충진량이 40~50(%vol.) 사이에 있음을 알 수 있다. 풍량 변화에 따른 공기측 압력강하 비교에서는 증발부 히트파이프가 응축부 히트파이프 보다 크게 계측 되었는데 증발부 표면에 생긴 결로수의 영향으로 생각된다. 평행류형 히트파이프는 핀-관형 히트파이프와 비교하여 냉매 충진량은 48%, 체적은 41%에서 동등이상의 성능을 보였으며, 공기측 압력강하도 37% 정도로 좋은 성능을 나타내었다.