• Title/Summary/Keyword: Charging Particles

Search Result 93, Processing Time 0.025 seconds

Effect of Particle Loading on the Collection Performance of an Electret Cabin Air Filter for Submicron Particles (입자 퇴적이 승용차용 정전 필터의 미세 입자 포집 특성에 미치는 영향)

  • Ji, Jun-Ho;Gang, Seok-Hun;Hwang, Jeong-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1102-1114
    • /
    • 2002
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles were loaded. Long-term experiments were conducted by applying two different charging states, which were spray electrification and charge equilibrium by bipolar ionization. In order to investigate the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. Liquid DOS particles were used to evaluate the effect of liquid particles on the collection efficiency of an electret filter. The results show significant effect of charge amount and size distribution of loading particles on the collection performance of a filter media in submicron region. Smaller particles loaded in electret fibers cause a more rapid degradation in collection efficiency and have lower minimum efficiency with time. The pressure drop of a filter media do rarely increase when the collection efficiency decreases to the minimum value. For the larger particles charged by spray electrification, which have charge amounts more than that of Boltzmann equilibrium charge distribution, the pressure drop of a filter media slowly increases in comparison with that of equilibrium charged particles. For DOS particles it is shown that the charging level of an electret filter severely decreases and the collection efficiency is below 10% in some particle size range.

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

On-line Measurement of the Surface Area Concentration of Aerosols in Yokohama, Japan, using the Diffusion Charging Method

  • Hatoya, Kazuki;Okuda, Tomoaki;Funato, Koji;Inoue, Kozo
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.1-12
    • /
    • 2016
  • Numerous researchers have proposed that surface area is a more appropriate indicator than mass for evaluating pulmonary inflammatory responses caused by exposure to fine and ultrafine particles. In this study, measurements of surface area concentrations of aerosols were conducted in Yokohama, Japan, using the diffusion charging method. $PM_{2.5}$ mass concentration and black carbon concentration in $PM_{2.5}$ were also measured. The 24-hour continuous measurement campaigns were conducted 39 times from March to November, 2014. The surface area concentration was more closely correlated with the black carbon concentration than with the $PM_{2.5}$ mass concentration. It is considered that the abundance of black carbon particles significantly affects the surface area concentration of $PM_{2.5}$. The strength of the correlation between the surface area and black carbon concentrations varied considerably among the measurement campaigns. A relatively weaker afternoon correlation was observed compared with the other time zones (morning, evening, and night). We consider that these phenomena are due to the transportation/formation of the particles other than black carbon that affects surface area concentration and/or the variation of the surface condition of the black carbon particles.

Particle Agglomeration of a Bipolar Charging System with a Control Grid (제어전극을 갖는 쌍극성 하전장치의 입자응집 특성)

  • Moon, Jae-Duk;Ahn, Chang-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.465-470
    • /
    • 2005
  • In this paper. an experimental study, for method of increasing the efficiency of electrostatic precipitator for the collection of submicron-sized particles has been studied. All AC electric field was used to induce agglomeration of bipolory charged Particles. .4 bipolar AC-agglomeration system. consisted with a multineedle-mesh discharge system with a control grid, was proposed and investigated. Systematic experiments were carried out to investigate the agglomeration ratio of the AC-agglomeration system as a function of the different grid spacings and grid resistances for the submicron particles generated from liquid prorhane gas burning. The agglomeration ratios, which indicate the particle numbers before and after agglomeration of the test particles in number concentration base, were found to be 0.87, 1.80, 3.86, 9.50 and, 11.00 times for the particle sizes of 0.3. 0.5, 0.7, 1.0, and 2.0$\mu$m at applied voltage of 3.5kV, respectively which showed that the fine particle numbers were decreased while the larger particle numbers were increase greatly.

Particle Charging and Collection in Two-Stage, Parallel-Plate Electrostatic Precipitators (2단 평행판 정전식 집진기에서의 입자하전 및 포집)

  • 오명도;유경훈;이준식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.432-445
    • /
    • 1994
  • From a theoretical analysis point of view, the 2-stage precipitator is decomposed into two units: charging cell and collecting cell. Collection efficiency predictions of the two-stage parallel-plate electrostatic precipitator have been performed theoretically incorporating with the charging and the collecting cells. Particle trajectorise passing the charging cell have been modeled as a simple one. Particle charge distribution at the outlet of the charging cell is calculated through integration of the present unipolar combined charging rate along the entire particle trajectory, and average charge of particles at the outlet of the charging cell is obtained from the particle charge distribution. As for the collecting cell, the diminution of particle concentration along the longitudinal direction of the collecting cell is investigated considering the conventional Deutsch's theory and the laminar theory. One should note that the collection efficiency formula derived is based on monodisperse aerosols. It has been confirmed through the analysis that predictions of particle charge by applying White's unipolar diffusion charging theory overpredict actual cases in the continuum regime, while predictions by Fuch's unipolar diffusion charging theory indicate the reasonable result in the same regime. Theoretical predictions of collection efficiency are also compared with the available experimental results. Comparisons show that the experimental results are consistently located in the collection efficiency region bounded by the two limits, the Deutsch and the laminar collection efficiencies. Finally design parameters of the 2-stage electrostatic precipitator have been investigated systematically through the one-variable-at-a-time method in terms of collection efficiency. Applied voltages on the corona wire of the charging cell and the plate of the collecting cell, and the average air velocity have been selected as the design parameters.

A Basic Study on Electrification Phenomena of Synthetic Polymer Material (합성고분자재료의 대전현상에 관한 기초연구)

  • 이덕출;한상옥
    • 전기의세계
    • /
    • v.28 no.10
    • /
    • pp.48-54
    • /
    • 1979
  • The electrification phenomena of polymerized materials is governed by the competitive processes of the charge generation and the charge dissipation. In this paper, The charged particles were supplied on the naked upper surface of the polyethylene film from a point corona discharge with a screen electrode which controls the potential difference across the film. The charging current with the corona charging was found to be larger than that obtained with the electric charging on the MIM structure and the discharge current was found to flow in the same direction as that of the charging current. these results can suggest that the charge injection occurs from the interface between the polethylene surface and the accumulated charge layer, the injected charge are trapped and the space charge is established.

  • PDF

Investigation on the Electrical Discharge Characteristics of a Unipolar Corona-Wire Aerosol Charger

  • Intra, Panich;Yawootti, Artit;Vinitketkumnuen, Usanee;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.556-562
    • /
    • 2011
  • In the present study, a simple corona-wire charger for unipolar diffusion charging of aerosol particles is designed, constructed, and characterized. Experimental characterizations of the electrostatic discharge in terms of current-voltage relationships of positive and negative coronas of the corona-wire charger are also presented and discussed. The charging current and ion concentration in the charging zone increased monotonically with corona voltage. The negative corona showed higher current than the positive corona. At the same corona voltages, the current in the discharge zone is about 600 times larger than the charging current. The ion number concentrations ranged within approximately $5.0{\times}10^{10}$ to $1.24{\times}10^{16}$ and $4.5{\times}10^{12}$ to $2{\times}10^{16}$ ions/$m^3$ in the discharge and charging zones, respectively. A numerical model is used to predict the behavior of the electric potential lines. Numerical results of ion penetration through the inner electrode are in good agreement with the experimental results.

Preliminary Study on the Measurement of the Electrostatic Charging State of PM2.5 Collected on Filter Media

  • Okuda, Tomoaki;Yoshida, Tetsuro;Gunji, Yuma;Okahisa, Shunichi;Kusdianto, K.;Gen, Masao;Sato, Seiichi;Lenggoro, I. Wuled
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.137-145
    • /
    • 2015
  • This study focused on the measurement of the actual charging state of ambient aerosol particles, which is important for understanding the intricate process of adverse health effects caused by particulate matter (PM). The net electrostatic charging state of $PM_{2.5}$ collected on filter media was measured in this study. The Faraday cage method and surface potential measurements were used in this study. The results showed that the polarities of the net charging state measured using these two methods were in agreement for 42 out of 48 samples (87.5%), and 36 samples (75%) were negatively charged. The filters were not significantly charged by friction between the filters and air not containing PM. Charge addition to or leakage from the filters was not observed over a two-month storage period. Net charging state of $PM_{2.5}$ collected on the filters was concluded to be negative in most cases, based on data's support of the assumption that aerosol charging state is not altered by the process of PM collection using filter.

Energy Storage Characteristics in Fixed Beds;Part 1. Charging Mode

  • Hassanein, Soubhi A.;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.158-164
    • /
    • 2004
  • In the present work, the numerical model was refined to predict the thermal analysis of energy storage in a fixed beds during charging mode. The governing energy equations of both fluid and the solid particles along with their initial and boundary conditions are derived using a two-phase, one dimensional model. The refined model is carried out by taking into account change of (air density , air specific heat) with air temperature and also by taking into considerations heat losses from bed to surrounding. Finite difference method was used to obtain solution of two governing energy equations of both fluid and solid particles through a computer program especially constructed for this purpose. The temperature field for the air and the solid are obtained, also energy stored inside the bed is computed. A comparison between refined model and non refined model is done. Finally using refined model the effect of bed material (Glass, Fine clay ,and aluminum ), and air flow rate per unit area Ga (0.3, 0.4, and 0.5 kg/$m^2$-s) on energy storage characteristics was studied.

  • PDF

An Experimental Study on the Small Capacity EHD Power Generation (소용량 EHD 발전에 관한 실험적 연구)

  • Jhoun, C.S.;Lee, J.B.;Lim, E.C.
    • Solar Energy
    • /
    • v.9 no.2
    • /
    • pp.58-68
    • /
    • 1989
  • This paper describes an experimental study that was performed to determine the limiting factors on the power output in the closed cycle Electro-Hydro-Dynamic generator of small capacity. A corona discharge for producing unipolar charged particles used as the charging method. The experiment demonstrated that the corona method of charging was an efficient and effective means of producing unipolar charged particles. Four factors having an effect on the power output characteristics of EHD generator are discussed and examined experimentally, using methyl alcohol and kerosene as working fluides; a. The conversion length between attractor and collector. b. The corona current of Emitter. c. The flow velocity of working fluids. d. Load resistance. This results are as follows; 1) There in a critical value in conversion length for its maximum power output. 2) Power output increases almost linearly with corona current and flow velocity. 3) There is the critical value of load resistance producing a maximum power output. 4) Kerosene is known better working fluid than Methyl alcohol in this EHD generator.

  • PDF