• Title/Summary/Keyword: Charging Infrastructure

Search Result 98, Processing Time 0.031 seconds

Design of AC/DC Combined V2X System for Small Electric Vehicle (소형 전기차 적용을 위한 AC/DC 복합 V2X 시스템 설계)

  • Kim, Yeong-Jung;Chang, Young-Hag;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.617-624
    • /
    • 2022
  • The small electric vehicles equipped with V2X(vehicle to everything) systems may provide more information and function to the existing navigation system of the vehicle. The key components of V2X technology include V2V (vehicle to vehicle), V2N(vehicle to network) and V2I (vehicle to infrastructure). This study is to design and implementation of VI type E-PTO which is interfaced with external equipments, the work designs the components of E-PTO such as DC/DC converter, DC/AC converter, battery bidirectional charging system etc. Also, it implements the devices and control systems for driving. The test results of VI type E-PTO components showed allowable 10% requirements of transient voltage variation rate and recovery time within 100ms for start/stop and normal operation.

Human Resource Nurturing Algorithm Leading the Energy and Electric Element Technology of Electric Vehicles (전기자동차의 에너지 및 전기 요소기술을 선도하는 인력양성 알고리즘)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.181-186
    • /
    • 2022
  • The world's electric automobile sector has shifted beyond technological environmental changes to a stage that has an impact on the market environment. And automakers are shifting from the existing strategy of "technological advantage → brand enhancement → sales expansion of existing internal combustion engine vehicles" to the expansion of the electric automobile market itself, which is to enhance market competitiveness. In addition, competition in the electric automotive parts market is expected to intensify due to the expansion of the business areas of existing parts makers and the entry of new companies, and development cooperation is expected to actively proceed to improve the efficiency of major eco-friendly parts. Along with this prospect, electric vehicles are expected to change the overall structure of the automobile industry, the overall growth of the electric vehicle value chain such as batteries, power trains (motors, power management and control systems), electric vehicle production, and charging infrastructure Is expected. Therefore, in this thesis, in order to cultivate a variety of high-quality human resources that companies want to keep pace with the changing automobile industry, we study a professional manpower training program that leads the growth engine of the electric automobile industry.

A Study on Damage Assessment for Fuel Cell Facilities in Gas Stations (주유소 내 연료전지설비에 대한 사고피해예측 연구)

  • Sung Yoon Lim;Jang Choon Lee;Jae Hoon Lee;Seung Ho Choi
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.1
    • /
    • pp.71-80
    • /
    • 2023
  • Fuel cells are low-carbon power sources that can expand distributed energy system and electric vehicle charging infrastructure when installing fuel cells in gas stations. In order to ensure safety for fuel cells in gas stations, quantitative risk assessments were conducted after deriving accident scenarios based on accident data of domestic and foreign gas stations and fuel cells. It calculates the expected extent of damage from fire and explosion that can occur in reality, not the worst accident scenario, and analyzes the damage impact. The separation distance of more than 9.0 m from a dispenser, 15.5 m from a car under refueling, 4.1 m from the ventilation pipe, 1.1 m from the gas adjustment device prevent the severe damage caused by the expected accident. This study result can be used to deploy fuel cells in gas stations and establish safety measures.

Risk Assessment for High Capacity Multiport Hydrogen Refueling Station (대용량 멀티포트 동시 충전 기반 수소충전소 안전성 평가 연구)

  • CHOONGHEE JOE;SEUNGKYU KANG;BUSEUNG KIM;KYUNGSIK LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.505-513
    • /
    • 2023
  • Hydrogen infrastructure is expanding. High-capacity hydrogen refueling stations offer advantages because they can refuel a variety of light and heavy-duty vehicles, and multi-port refueling technology is developing to reduce charging time for heavy-duty vehicles. In this study, we suggest directions to lower the risk by analyzing the risk factors for each process involved in the installation of a high-capacity multi-port hydrogen refueling station in Changwon city. We conducted both qualitative and quantitative risk assessments of the equipment to evaluate the station. A hazard and operability study was performed for qualitative risk assessment, and PHAST/SAFETI were used for quantitative risk assessment. Quantitative risk assessment was used to calculate the consequence analysis of the facility to ensure secure design prior to station development and to predict individual and societal risks in various scenarios. As a result, the station's risk level was determined to be as low as reasonably practicable.

Smart Electric Mobility Operating System Integrated with Off-Grid Solar Power Plants in Tanzania: Vision and Trial Run (탄자니아의 태양광 발전소와 통합된 전기 모빌리티 운영 시스템 : 비전과 시범운행)

  • Rhee, Hyop-Seung;Im, Hyuck-Soon;Manongi, Frank Andrew;Shin, Young-In;Song, Ho-Won;Jung, Woo-Kyun;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.127-135
    • /
    • 2021
  • To respond to the threat of global warming, countries around the world are promoting the spread of renewable energy and reduction of carbon emissions. In accordance with the United Nation's Sustainable Development Goal to combat climate change and its impacts, global automakers are pushing for a full transition to electric vehicles within the next 10 years. Electric vehicles can be a useful means for reducing carbon emissions, but in order to reduce carbon generated in the stage of producing electricity for charging, a power generation system using eco-friendly renewable energy is required. In this study, we propose a smart electric mobility operating system integrated with off-grid solar power plants established in Tanzania, Africa. By applying smart monitoring and communication functions based on Arduino-based computing devices, information such as remaining battery capacity, battery status, location, speed, altitude, and road conditions of an electric vehicle or electric motorcycle is monitored. In addition, we present a scenario that communicates with the surrounding independent solar power plant infrastructure to predict the drivable distance and optimize the charging schedule and route to the destination. The feasibility of the proposed system was verified through test runs of electric motorcycles. In considering local environmental characteristics in Tanzania for the operation of the electric mobility system, factors such as eco-friendliness, economic feasibility, ease of operation, and compatibility should be weighed. The smart electric mobility operating system proposed in this study can be an important basis for implementing the SDGs' climate change response.

Crash Safety Evaluation of LNG Fuel Containers for Vehicles using ANSYS Explicit Dynamics (ANSYS Explicit Dynamics 해석을 활용한 차량용 LNG 용기의 충돌안전성 평가)

  • Nam, SuHyun;Kim, JiYu;Kim, EuiSoo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.58-63
    • /
    • 2022
  • With the emergence of environmental problems caused by fine dust worldwide, LNG, which is cheaper and less pollution than diesel, is attracting attention as the next generation energy of automobiles and is expanding its supply. However, it is difficult to operate smoothly due to the lack of infrastructure for LNG charging stations in Korea and the limited size of containers that can be installed according to regulations. In Korea, research and development on the contents of containers for the smooth operation of natural gas vehicles are underway, but there is a problem that the container directly receives the impact of the vehicle collision and explodes, causing a major disaster. Therefore, in this study, the safety of the container was verified by deriving the strain and stress values through ANSYS Explicit Dynamics analysis. As a result, a maximum stress of 565.37MPa occurred in the container, and it is expected that plastic deformation will occur as it exceeds the yield stress of STS304 used as a material for the container, which is beyond 505MPa. When an impact caused by a collision between a vehicle and a container is applied, it is considered necessary to design a support or reinforcement because the container may be damaged or defective.

Assessment of the Potential Consumers' Preference for the V2G System (V2G 시스템에 대한 잠재적 소비자의 선호 평가)

  • Lim, Seul-Ye;Kim, Hee-Hoon;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.93-102
    • /
    • 2016
  • Vehicle-to-Grid (V2G) system, bi-direction power trading technology, enables drivers possessing electric vehicle to sell the spare electricity charged in the vehicle to power distribution company. The drivers gain profit by charging electricity in the day time of high electricity rate. In this regard, the government is preparing the policies of building and supporting V2G infrastructure and demanding the potential consumers' preference for the V2G system. This paper attempts to analyze the consumers' preference using the data from obtained a survey of randomly selected 1,000 individuals. To this end, choice experiment, an economic technique, is employed here. The attributes considered in the study are residual amount of electricity, electricity trading hours, required plug-in time, and price measured as an amount additional to current gasoline vehicle price. The multinomial logit model, which requires the assumption of 'independence of irrelevant alternatives', is applied but the assumption could not be satisfied in our data. Thus, we finally utilized nested logit model which does not require the assumption. All the parameter estimates in the utility function are statistically significant at the 10% level. The estimation results show that the marginal willingness to pay (MWTP) for one hour increase in electricity trading hours is estimated to be KRW 1,601,057. On the other hand, a one percent reduction in residual amount of electricity and one hour reduction in required plug-in time in V2G system are computed to be KRW -91,911 and -470,619, respectively. The findings can provide policy makers with useful information for decision-making about introducing and managing V2G system.

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.