• Title/Summary/Keyword: Charge amount

Search Result 657, Processing Time 0.032 seconds

A Study of the Irradiation Environment Effects on the Electrical Properties of Ethylene Propylene Rubber (방사선 조사 환경에 의한 에칠렌 프로필렌 고무의 전기 특성에 관한 연구)

  • 이성일
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.2
    • /
    • pp.187-200
    • /
    • 2000
  • The charge and discharge current in EPR(Ethylene Propylene Rubber), which were irradiated with the radiant capacity of 0~600 [kgy/h], have been measured in order to investigate the influence of the atmosphere (oxygen, air and vacuum) on electrical properties. It has been shown that the charge and discharge current increase as the amount of radiant capacity increases in air and vacuum atmosphere. This electrical property degradation can be speculated due to that the C=O radicals or impurities, which comes from during shaping process, may act as dipoles. On the other hand, the charge and discharge current are shown to be higher in the amount of 1[kgy/h] than these in 10[kgy/h] in air atmosphere, because the charge and discharge current can be increased as the exposure time is extended with slower rate. Under the same amount of irradiation, the charge and discharge current in oxygen atmosphere are shown to be higher than those in vacuum. This is possibly due to that the main chain can be broken by oxidation when it is exposed to the $\gamma$ -rays.

  • PDF

Prediction of practically chargeable cold energy in an ice storage system (빙축열시스템의 실질적인 최대 축열 가능량 예측)

  • Lee, D.-Y.;Kang, B.H.;Kim, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

A Study on Properties of Charge & Discharge Current by Degrade in EPR (EPR의 열화에 의한 충.방전 전류 특성에 관한 연구)

  • Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.7
    • /
    • pp.679-685
    • /
    • 2008
  • This paper describes the degraded properties of between the charge and discharge current for ${\gamma}$-ray irradiated in electric power cable rubbers using in nuclear power generating station. The charge and discharge current of degradation in EPR(Ethylene Propylene Rubber), which were irradiated with the radiant capacity of 0.033 Mrad/h, have been measured in order to investigate the influence of the atmosphere(in amount of reinforcing agent, moisture absorption and heat treatment) on electrical properties. When ${\gamma}$-ray were irradiated on the EPR with more reinforcing agent from 4 to 40 Phr, charge and discharge currents was increase due to the amount of reinforcing agent. It was verified that the discharging and charging currents irradiated by ${\gamma}$-ray were higher than those that was not irradiated. The amount of the degraded current was more after moisture absorption than before moisture absorption. The charge and discharge current after heat treatment was similar to that of before heat treatment and it was decreased with the time elapsed. As these properties related with ${\gamma}$-ray irradiation dose, it is suggested that these properties can be utilized as a index of irradiation degradation.

The Effect of Working Fluid Charge on the Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System (중온 태양열 축열조용 히트파이프의 작동액체 충전량이 열성능에 미치는 영향)

  • Min, Kyu-Park;Joon, Hong-Boo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.68-73
    • /
    • 2011
  • An experimental study was conducted to investigate the thermal performance of a medium-temperature heat pipe against the charge amount of working fluid. The container and the wick of the heat pipe were made of stainless steel and the working fluid was Dowtherm-A for medium-temperature applications around $250^{\circ}C$. The diameter and length of the heat pipe were 25.4 mm and 1 m, respectively. The maximum thermal load was 1 kW and the working fluid charge ratio varied from 372% to 420%. The results showed that the thermal resistance ranged from 0.12 to $250^{\circ}C/W$ and the effective thermal conductance ranged from 7,703 to $8,898 W/m{\cdot}K$. Dry-out occurred for the heat pipe with 372% fill-charge at the heat load of 950 W, while the other heat pipes with higher charge amount did not encounter dry-out up to 1060 W.

  • PDF

Evaluation of Copper-Chromium-Arsenic Preservatives Fixation on Wood by Measuring the Density of Surface Electric Charge (표면전하밀도(表面電荷密度)를 이용(利用)한 동(銅)·크롬·비소계(砒素系) 방부방충제의 정착(定着)에 관(關)한 연구(硏究))

  • Kim, Yeong-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 1990
  • This study was attempted to propose a method evaluating fixation of active ingredients in Copper-Chromium-Arsenic preservatives treatment. Fixated amount of active ingredients on wood was obtained by measuring the density of surface electric charge based on $\varsigma$ potential. Data accumulated from density of surface electric charge showed that the fixated amount of preservatives on wood increased linearly as concentration of treating solution increaced, which indicatied quantitative reactions in fixation of preservatives.

  • PDF

The Effect of Industrial Waste Water Effluent Charge Reform (수질배출부과금제도 개선 방안 연구)

  • Min, DongKi
    • Environmental and Resource Economics Review
    • /
    • v.18 no.4
    • /
    • pp.767-785
    • /
    • 2009
  • This paper studies the effect of industrial waste water effluent charge reform. The goal of the present effluent charge system is to use environmental resources in an efficient way by charging the cost for removing emitted water pollutants. However, the present system is a type of regulation instead of providing economic incentives to the industry. That is, if a firm emits pollutants greater than the limit, it has to pay an amount greater than the cost of cleaning them taking into account the amount of waste water discharged, region, the number of violation and the level of density of pollutants. However, the excessive fees have resulted in the lowest ratio of revenue-to-effluent charge among all environmental charges. The paper estimates the effect of the change in effluent fee and revenue when the present effluent charge system is converted to one that offers economic incentives. The results show that the amount of waste water effluent charge is about four times larger than the estimated environmental cleaning cost. In addition, the results show that by modifying the effluent charge system, the ratio of revenue to effluent charge can be raised.

  • PDF

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

Comparisons of Performance in CO2 Systems with Operating Conditions (운전조건 변화에 따른 이산화탄소 냉방시스템들의 성능 비교)

  • Bae, Kyung-Jin;Shin, Eun-Sung;Cho, Hong-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1484-1490
    • /
    • 2009
  • Since the cooling performance of a $CO_2$ cooling cycle is varied significantly with a variation of refrigerant charge amount and outdoor temperature, the reliability of $CO_2$ system is down. In this study, the performance characteristics of three kinds of $CO_2$ systems were measured and analyzed by varying refrigerant charge amount and outdoor temperature so as to study the characteristics of variation with cycle option. The applied system options are the single-stage compression(1C-1E) system, two-stage compression with 1-EEV(2C-1E) system, and two-stage compression with 2-EEV(2C-2E) system. The performances of two-stage compression with 2-EEV system were less sensitive than those of other systems and the system operated safely and steadily for wide charge amount. The performance of the two-stage compression with 1-EEV(2C-1E) system was the most sensitive to the charge amount, and that of the single-stage compression(1C-1E) system varied a lot with outdoor temperature.

  • PDF

Experimental Study on the Variation of the optimal charge with cycle option in the $CO_2$ Refrigeration (이산화탄소 냉동사이클에서 사이클 사양에 따른 최적충전량 변화에 관한 실험적 연구)

  • Cho, Hong-Hyun;Ryu, Chang-Gi;Lee, Ho-Seong;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.398-403
    • /
    • 2005
  • The cooling performance of a transcritical $CO_2$ cycle varies significantly with a variation of refrigerant charge amount. In this study, the performance of the $CO_2$ system was measured and analyzed by varying refrigerant charge amount with a change of cycle option. The applied cycle options are the single-stage compression system, two-stage compression with 1-EEV system, and two-stage compression with 2- EEV system. The optimum normalized charge were 0.363, 0.297, and 0.282 for the two-stage compression with 2-EEV system, two-stage compression with 1-EEV system, and single-stage compression system, respectively.

  • PDF

A study on Improvement and Invigoration of Cooperation Charge on Conservation Ecosystem Fund (생태계보전협력금 제도 활성화를 위한 부과금 개선 방안 연구)

  • Kim, Gyung-Ho;Lee, Sang-Houck
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.6
    • /
    • pp.97-109
    • /
    • 2011
  • Korea introduced the cooperation charge on conservation of ecosystem for minimizing damage of ecosystem due to development projects and their effects and for preparing resources for natural environment conservation projects. Advanced countries have made efforts by expanding investment in natural environment conservation and restoring projects to promote prevention of global warming and improvement of biological diversity, are establishing nationwide strategies and plans. To examine the reality of projects by returns of the cooperation charge on conservation of ecosystem, microsite projects in schools and public facilities take the largest share while their project budgets are only about 100~300 KRW, relatively small, which might be attributable to budget restrictions in accordance with the calculating method of levying cooperation charge on conservation of ecosystem and problems of project proceeding in the system of returning fund for projects in general. The conclusion which this study suggests on invigoration of cooperation charge on conservation of ecosystem and its operation are as followings. First, although the cooperation charge on conservation of ecosystem has been introduced in 2001, the amount of imposition per unit area remains unchanged. It is desirable to increase the amount into $1,400KRW/m^2$ as of August, 2011 as the price index has been continuously rising for the past 10 years and the upward adjustment of imposition per unit area should be notified by the decree of the Ministry of Environment every January. Second, the ceiling amount of the cooperation charge on conservation of ecosystem should be abolished. Now the ceiling amount is defined as 1 billion KRW but it was found that there was not any ceiling amount specified according to the comparative analysis of similar systems with the Korean environmental improvement fund. The ceiling should be abolished so that medium level businesses are carried out and ecosystem recovering projects in the true sense of the word can be made smoothly. Third, weight should be introduced in calculating amounts in accordance with ecologic and economic values. Harmony between development and environment can be achieved by applying differentiated weights of constant regional coefficient by use zone and ecologic and economic values. Continuous efforts of improving cooperation charge on conservation of ecosystem should be made more than anything else so that projects by returns of cooperation charge on conservation of ecosystem get effectiveness.