• 제목/요약/키워드: Charge Coupled Device(CCD)

Search Result 181, Processing Time 0.028 seconds

Determination of the Depletion Depth of the Deep Depletion Charge-Coupled Devices

  • Kim Man-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.233-236
    • /
    • 2006
  • A 3-D numerical simulation of a buried-channel CCD (Charge Coupled Device) with a deep depletion has been performed to investigate its electrical and physical behaviors. Results are presented for a deep depletion CCD (EEV CCD12; JET-X CCD) fabricated on a high-resistivity $(1.5k\Omega-cm)\;65{\mu}m$ thick epi-layer, on a $550{\mu}m$ thick p+ substrate, which is optimized for X-ray detection. Accurate predictions of the Potential minimum and barrier height of a CCD Pixel as a function of mobile electrons are found to give good charge transfer. The depletion depth approximation as a function of gate and substrate bias voltage provided average errors of less than 6%, compared with the results estimated from X-ray detection efficiency measurements. The result obtained from the transient simulation of signal charge movement is also presented based on 3-Dimensional analysis.

Analysis of Hematoporphyrin Derivative by Design and Manufacture of High Resolution Charge Coupled Device in Spectrometry (분광기에 고 분해능 Charge Coupled Device의 설계 및 제작에 의한 Hematoporphyrin Derivative의 분석)

  • Kim, Ki-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.77-83
    • /
    • 2005
  • The influence of fluorescence, scattering, and absorbance in turbid material by light scattering was interpreted by the scattered fluorescence intensity and wavelength. The effect of optical property in scattering media was investigated. It is very important to study the charge coupled device(CCD) in spectrometry because we can use the molecular energy level, molecular structure, absorption or emission, intermolecular reaction, weakly bound molecular energy, photochemistry, fluorescence and photodynamic therapy. CCD is very essential to study the molecular structure and medical engineering combined laser spectroscopy in the modem physical and chemistry. Accordingly, this study has designed and manufactured the electromagnetic spectrometry with CCD, and has analyzed the hematoporphyrin derivative.

A Transversal Low Pass Filter Using Charge Coupled Device with Two Level Aluminum Electrode Structure (2중 알루미늄 전극구조의 Charge Coupled Device를 이용한 저역 여파기)

  • 신윤승;김오현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.3
    • /
    • pp.25-34
    • /
    • 1981
  • Aluminum anodization method has been investigated for fabricating charge coupled device(CCD) with two-level aluminum gate structure. Al2O3 films were formed to a thickness of 400-500A, by anodizing aluminum with 30-35V of anode voltage for 2 hours using 2 % ammonium tartrate solution as an electrolyte. Breakdown voltage of these films were about 30 volts. Using above mentioned Al2O3 film as an insulator between two aluminum electrodes, CCD transversal low pass filter has been fabricated. CCD transversal low pass filter with 17 tap coefficients has shown 22 dB stop-band attenuation. The operating clock frequency range of the fabricated device was from 3 KHz to 100 KHz.

  • PDF

DI water Nozzle Design for Effective Removal of the Particles Generated during Wafer-sawing (Wafer-Sawing시 발생하는 particle을 효과적으로 제거하기 위한 DI water 노즐의 최적 설계)

  • 김병수;이기준;이성재
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.53-60
    • /
    • 2003
  • CCD(Charge-Coupled Device) wafers, with a layer of micro lenses on top, usually are not passivated with dielectric films. Micro lenses, in general, are made of polymer material, which usually has a large affinity for particles generated in the various chip fabrication processes, most notably the wafer sawing for chip-dicing. The particles deposited on the micro lens layer either seriously attenuate or deflect the incoming light and often lead to CCD failure. In this study we introduce new type of saws which would significantly reduce the particle-related problems found in conventional type of saws. In the new saws, the positions and diverging angles of side and center nozzles have been optimized so as to flush the particles effectively. In addition, an independent nozzle is added for the sole purpose of flushing the generated particles. The test results show that, with the new saws. the ratio of the particle-related CCD chip failures has been dropped drastically from 9.1% to 0.63%.

  • PDF

Modulation Transfer Function Measurement of a Linear Charge Coupled Device Imager by Using a Knife-Edge Scanner (칼날주사방법에 의한 일차원 CCD의 MTF 측정)

  • 조현모;이윤우;이인원;이상태;이종웅
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.173-177
    • /
    • 1995
  • The scanning type modulation transfer function (MTF) measurement system of linear charge coupled device (CCD) imagers is fabricated and the MTF of a linear CCD imager is tested. Measured MTF values are very sensitive to small angle knife-edge skew within 1 degree and show different results in several wavelengths. The MTF of the linear CCD imager is measured in different color temperatures of a tungsten filament lamp and the MTF uniformity of ti,t eel) pixels is tested.tested.

  • PDF

The design and Manufacture of Laser Induced Fluorescence Spectroscope Using the High Resolution Charge Coupled Device (고정밀 전하결합장치를 이용한 레이저유도 형광분광기의 설계 및 제작)

  • Kim, Ki-Jun;Lee, Hoo-Seol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.129-133
    • /
    • 2005
  • It is very important to use the charge coupled devices (CCDs) in spectrometry because we can study the molecular energy level, molecular structure, absorption or emission, intermolecular reaction, weakly bound molecular energy, photochemistry, fluorescence and photodynamic therapy (PDT). CCD is very essential to study the molecular structure and medical engineering combining laser spectroscopy in the modem physicsal and chemistry. Therefore, this study has designed and manufactured the electromagnetic spectrometry with CCD and then analyzed the printed electronic circuit. In the yesterday, CCD was thought to be used in only broadcasting system. But nowadays, it is used by industrial demand in observations, instrumentations and robotics as the industry develop.

  • PDF

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF

Evaluation of color CRT monitor by MTFA (MTFA에 의한 칼라 CRT의 화질 평가)

  • 김태희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.205-211
    • /
    • 1998
  • The MTF(modulation transfer function) measuring system with a linear CCD(charge coupled-device) was constructed to cvaluate a color CRT(catode ray tube). The measured MTF values were corrected by considering the spectral response and the pixel sizes of CCD. The effects of a spot size, video bandwidth, pitch of shadow mask holes, display luminance, and ambient illumination on image quality were studied. The uniformity of resolution and the contrast Ioss by ambient light of the color CRT monitor were measured, and the results were analyzed by MTFA(modulation threshold area).

  • PDF

Satellite EOS(Electronic optical system) CCD(charge coupled device) detector control driver module design

  • Park, Jong-Euk;Kong, Jong-Pil;Yong, Sang-Soon;Heo, Haeng-Pal;Kim, Young-Sun;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1121-1123
    • /
    • 2003
  • The CCD (Charge coupled device) detector that is used to convert the light into electronic data is very important component in satellite camera. A Linear CCD Spectral detector shall be used in the MSC (Multi-Spectral Camera, to obtain data for high-resolution images) Payload. In this paper, the design concept of the CCD detector control module in the MSC CEU (Camera electronic unit) system which will be a payload on KOMPSAT is described in terms of H/W (clock speed and accuracy).

  • PDF