• Title/Summary/Keyword: Charge Calculation

Search Result 279, Processing Time 0.029 seconds

Development of Battery Management System for Electric Vehicle Applications of Ni/MH Battery

  • Jung Do Yang;Lee Baek Haeng;Kim Sun Wook
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.4
    • /
    • pp.152-159
    • /
    • 2001
  • Electric vehicle performance is very dependent on traction batteries. For developing the electric vehicles with high performance and good reliability, the traction batteries have to be managed to get maximum performance under various operating conditions. The enhancement of the battery performance can be accomplished by implementing battery management system (BMS) that plays important roles of optimizing the control mechanism of charge and discharge of the batteries as well as monitoring battery status. In this study the battery management system has been developed for maximizing the use of Ni/MH batteries in electric vehicle. This system provides several tasks: the control of charging and discharging, overcharge and over-discharge protection, the calculation and display of state of charge, safety and thermal management. The BMS was installed in and tested using the DEV5-5 electric vehicle developed by Daewoo Motor Co. and Institute for Advanced Engineering in Korea. The 18 modules of Panasonic Ni/MH battery, 12 V-95 Ah, were used in the DEV5-5. The high accuracy within the range of $3\%$ and the good reliability were shown in the test results. The BMS can also improve the performance and cycle life of Ni/MH battery pack as well as the reliability and safety of the electric vehicles (EV).

A Study Based on Molecular Orbital Theory of Polymerization of Oxetane High Explosives (옥세탄 고폭 화약류의 중합반응에 관한 분자 궤도론적 연구)

  • Kim, Joon-Tae
    • Applied Chemistry for Engineering
    • /
    • v.20 no.2
    • /
    • pp.159-164
    • /
    • 2009
  • Monomers of oxetane high explosives were theoretically examined in terms of reactivity, reaction mechanism and process of polymerization substituted by azido $(-CH_2N_3)$, nitrato $(-CH_2ONO_2)$ and hydrazino $(-CH_2N_2H_3)$ which belong to the 5th class hazardous materials and have explosiveness under acid catalyst using MINDO/3, MNDO, and AMI methods for formal charge, heat of formation, and energy level. Nucleophilicity and base of oxetane high explosives could be explained by negative charge size of oxetane oxygen atom and reactivity of oxetane in the growth stage of polymerization under acid catalyzer could be expected to be governed by positive charge size of axial carbon atom and low LUMO energy of electrophile. It could be estimated that carbenium ion was more beneficial in the conversion process of oxetane high explosives than that of stabilization energy (13.90~31.02 kcal/mole) of oxonium ion. In addition, concentration of oxonium ion and carbenium ion in equilibrium state influenced mechanism and it was also estimated that $S_N1$ mechanism reacts faster than that of $S_N2$ in prepolymer growth stage considering quick equilibrium based on form and calculation of polymerization under acid catalyzer.

Molecular Orbital Theoretical Study on the Conformation and Chemical Reactivity of Insecticidal 0,0-Diethylphenylphosphate Derivatives (살충성(殺蟲性) 0,0-Diethylphenylphosphate 유도체(誘導體)의 형태(形態)와 반응성(反應性)에 관(關)한 분자궤도론적(分子軌度論的) 연구(硏究))

  • Park, Seung-Heui;Sung, Nack-Do;Myung, Pyung-Keun;Jeon, Young-Koo;Lee, Chun-Bae
    • Korean journal of applied entomology
    • /
    • v.24 no.4 s.65
    • /
    • pp.231-238
    • /
    • 1986
  • Molecular orbital theoretical study on the stability of conformations and chemical reactivity of 0,0-diethylphenylphosphate derivatives were carried out by EHT and CNDO/2 molecular orbital calculation method. The results shown that the dipole moment(${\mu}$) and total energies of the ${\theta}=90^{\circ}$ conformer were ${\mu}=3.185D\;&\;E_t=-162.6479(au)$ and also that of the ${\theta}=0^{\circ}$ conformer were ${\mu}=5.596D\;&\;E_t=-162.4013(au)$, respectively. Therefore, the values of ${\mu}\;&\;E_t$ of the ${\theta}=90^{\circ}$ conformer were much smaller than that of the ${\theta}=0^{\circ}$ conformer. The form with angle of rotation ${\theta}=90^{\circ}$ of phenyl ring was shown to be most stable and this was interpreted in terms of electrostatic and steric effect. 0,0-diethylphenylphosphate derivatives are predicted to increase both charge and orbital controlled $SN_2$ reactivity of the electron withdrawing substituent reduces the HOMO & LUMO energy, while the electron withdrawing substituent due to increase in positive charge of phosphorus atom of phosphate molecule.

  • PDF

A Study on the Feasibility of the Electrostatic Cell (PN접합 SCR내 전하주입을 통한 정전기전지 제작 가능성에 관한 연구)

  • Kang Hoe-Jong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.9-12
    • /
    • 2005
  • This paper describes the feasibility of the electrostatic cell using carrier injection in SCR(space charge region) of PN junction. It compares the principle of the electrostatic cell's operation with the solar cell's. According to the experiment and calculation of this paper, when the cross section area of the device is $0.0001cm^2$, the device current becomes 0.15mA which is practically high enough. This paper proposes that the electrostatic cell can be used as a physical battery.

Analytical Investigations on the Figures of Meander Lines on the YBCO Thin Film for Resistive Fault Current Limiters (YBCO 박막형 저항형 한류기에 적용 가능한 Meander Line 해석 연구)

  • 이방욱;강종성;박권배;오일성;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.221-224
    • /
    • 2002
  • Superconducting electrical devices are under development in a national project in Korea. And KEPCO and LGIS are in charge of development of a resistive type fault current limiters(FCLs) with YBCO thin films. In order to realize FCLs, the rated power of FCLs must be increased. For this purpose, it is of great interest to increase of allowed voltage of unit component without electrical and thermal damages. So, meander lines were widely used for the conducting path to increase maximum electric field. In this research, numerical simulations on the electromagnetic behaviors of the device were carried out, especially focusing on the effect of meander line structures on the YBCO thin films. To evaluate the structures of meander lines, three types of meander lines were considered for numerical analysis using finite element method (FEM). In this simulation, both normal state and fault conditions were considered for calculation of electric field, current density, magnetic field density. And the simulation resulted are compared to find the optimum design of meander lines for resistive FCLs.

  • PDF

Estimation of Resident Support Fund Regarding Types of Environmental Foundational Facilities - Focus on Gangwon Provincial Government - (환경기초시설별 주민지원금 산정방안 - 강원도 중심으로 -)

  • Choi, Yong-Bum;Lee, Hae-Seung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.9
    • /
    • pp.905-910
    • /
    • 2006
  • This research is conducted to calculate optimum residents grant regarding types of environmental foundational facilities. In the case of Gangwon province, it was particularly referred in this study, the residents grant of waste treatment facilities was excessively discharged as $1.6{\sim}75.0%$ of construction cost. This kind of excessive residents grant has overweighted the local governments' financial conditions. Accordingly, it is necessary to increase the amount of charge on the national treasury. In the calculation method of optimum residents grant reasonable resident support fund of waste treatment facilities was computed the range of 20%, food waste treatment facilities was 10% ranges and sewage and night soil combination treatment facilities was $3{\sim}5%$ ranges.

Effects of the Particle Electric Conductivity on the Aggregation of Unipolar Charged Nanoparticles (단극하전 나노입자의 응집성장 과정에서 입자의 전기전도도의 효과에 대한 연구)

  • Park, Hyung-Ho;Kim, Sang-Soo;Chang, Hyuk-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.173-180
    • /
    • 2003
  • Effects of the electric conductivity of particles were studied for the aggregation process of charged particles with a Brownian dynamic simulation in the free molecular regime. A periodic boundary condition was used for the calculation of the aggregation process in each cell with 500 primary particles of 16 nm in diameter. We considered two extreme cases, a perfect conductor and a perfect nonconductor. The electrostatic force on a particle in the simulation cell was considered as a sum of electrostatic forces from other particles in the original cell and its replicate cells. We assumed that aggregates were only charged with pre-charged primary particles. The morphological shape of aggregates was described in terms of the fractal dimension. The fractal dimension for the uncharged aggregate was D$_{f}$= 1.761. However, the fractal dimension decreased from 1.694 to 1.360 for the case of the perfect conductor, and from 1.610 to 1.476 for the case of the perfect nonconductor, with the increase of the average number of charges on the primary particle from 0.2 to 0.3. These values were smaller than that of the centered charge case.e.

Design, Implementation and Testing of HF transformers for Satellite EPS Applications

  • Zahran, Mohamed
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.217-227
    • /
    • 2008
  • The electric power subsystems (EPS) of most remote sensing satellites consist of a solar array as a source of energy, a storage battery, a power management and control (PMC) unit and a charge equalization unit (CEU) for the storage battery. The PMC and CEU use high frequency transformers in their power modules. This paper presents a design, implementation and testing results of a high frequency transformer for the EPS of satellite applications. Two approaches are used in the design process of the transformer based on the pre-determined transformer specifications. The transformer is designed based on an ETD 29 ferrite core. The implemented transformer consists of one center-tapped primary coil with eleven center-tapped secondary coils. The offline calculation results and measured values of R, L for transformer coils are convergence. A test circuit for measuring the transformer parameters like voltage, current and B-H hysteresis was implemented and applied. The test results confirm that the voltage waveforms of both primary and secondary coils were as desired. No overlapping occurred between the control signal and the transformer, which was not saturated during testing even during a short circuit test of the secondary channels. The dynamic B-H loop characteristics of the used transformer cores were measured. The sample test results are given in this paper.

Calculation of Distribution Network Charging for DG Embedded Distribution System (분산전원 투입을 고려한 배전망 이용요금 산정에 관한 연구)

  • Hwang, Seok-Hyun;Kim, Mun-Kyeom;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.513-521
    • /
    • 2012
  • With the advent of smart grid, distribution network charges have been one of keystones of ongoing deregulation and privatization in power industries. This paper proposes a new charging methodology to allocate the existing distribution network cost with an aim of reflecting the true cost and benefit of network customers, especially of distribution generator (DG). The proposed charging methodology separates distribution network costs due to the respective real and reactive power flows. The costs are then allocated to network users according to each charge for the actual line capacity used and available capacity. This distribution network charging model is able to provide the economic signals to reward network users who are contributing to better power factors, while penalizing customers who worsen power factors. The proposed method is shown on IEEE 37 bus system for distribution network, and then the results are validated through the comparison with the MW-Miles and MVA-Miles methods. The charges derived from the proposed method can provide appropriate incentives/penalties to network customers to behave in a manner leading to a better network condition.

Development of catering system using 3-Tier architectures (3-Tier 구조를 이용한 케이터링 시스템 개발)

  • Kim, Hyeock-Jin
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.4
    • /
    • pp.421-426
    • /
    • 2006
  • Because the 3-Tier structure cia share a business logic, the reuse of existing code could be guaranteed Al so tiny and little client application in charge of user interface can he made that it doesn't need plenty of client memory and calculation capability. Catering system that capable of meal material code management autom atic production of requiring quantity, purchase and shipping management menu management, account management was developed for grafting 3-Tire structure technology using database language and ADO(ActiveX Dat a Object). This system improved production in field of school lunch program and saved o(poises. finally, this system is suitable to the service environment of school lunch program and lots of utilizations would be anticipated.

  • PDF