• Title/Summary/Keyword: Characteristic time

Search Result 5,063, Processing Time 0.033 seconds

A Design Method Reducing the Effect of Zeros of a Cascaded Three-Parameters Controller: The Characteristic Ratio Assignment Approach (종속형제어기의 영점의 영향을 고려한 3-파라미터 제어기의 설계: 특성비지정 접근법)

  • Jin Li-Hua;Lee Kwan-Ho;Kim Young-Chol
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.1
    • /
    • pp.20-23
    • /
    • 2006
  • This paper presents a new approach to the problem of designing a cascaded three-parameters controller for a given linear time invariant (LTI) plant in unity feedback system. We consider a proportional-integral-derivative (PID) and a first-order controller with the specified overshoot and settling time. This problem is difficult to solve because there may be no analytical solution due to the use of low-order controller. Furthermore, the zeros of controller just appear in the zeros of feedback system. The key idea of our method is to impose a constraint on the controller parameters so that the zeros of resulting controller are distant from the dominant pole of closed-loop system to the left as far as the given interval. Two methods realizing the idea are suggested. We have employed the characteristic ratio assignment (CRA) in order to deal with the time response specifications. It is noted that the proposed methods are accomplished only in parameter space. Several illustrative examples are given.

Evaluation of the Relationship Between Possible Earthquake Time History Shape Occurring in a Target Fault Using Pseudo-Basis Function (유사기저함수를 사용한 대상 단층에서 발생 가능 지진파 형태 사이의 관계 표현 방법 개발 및 포항 단층과 경주 단층 발생 지진에의 적용)

  • Park, Hyung Choon;Oh, Hyun Ju
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.139-145
    • /
    • 2023
  • It is essential to determine a proper earthquake time history as a seismic load in a seismic design for a critical structure. In the code, a seismic load should satisfy a design response spectrum and include the characteristic of a target fault. The characteristic of a fault can be represented by a definition of a type of possible earthquake time history shape that occurred in a target fault. In this paper, the pseudo-basis function is proposed to be used to construct a specific type of earthquake, including the characteristic of a target fault. The pseudo-basis function is derived from analyzing the earthquake time history of specific fault harmonic wavelet transform. To show the feasibility of this method, the proposed method was applied to the faults causing the Gyeong-Ju ML5.8 and Pohang ML5.3 earthquakes.

An Estimation of Breakdown Time of the Epoxy Composites according to Filler and Silane Treatment (충진제와 실란처리에 따른 에폭시 복합체의 파괴시간 예측)

  • Shin, Cheol-Gi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.793-797
    • /
    • 2007
  • In this paper, the long time breakdown characteristic of the epoxy composite, which is widely used in the insulation system for high voltage application, was estimated with Weibull distribution. In the procedure of the estimation, the short time breakdown characteristics for the epoxy composite specimens, which were made with the variation of hardener and/or filler, were tested firstly. Then the long time voltage-to-time test was implemented. Finally, the long time breakdown voltage of each specimen was estimated with the parameters obtained from the statistical treatment with Weibull distribution. Base on the results, it has been found that the optimal weight ratio of epoxy resin/hardener/filler that has the excellent long time breakdown characteristic was 100/100/65. It was due to the silane treatment which relieves the electric field at the interface between filler and epoxy.

Criterion for judging seismic failure of suspen-domes based on strain energy density

  • Zhang, Ming;Parke, Gerry;Tian, Shixuan;Huang, Yanxia;Zhou, Guangchun
    • Earthquakes and Structures
    • /
    • v.15 no.2
    • /
    • pp.123-132
    • /
    • 2018
  • In this paper the strain energy density (SED) model is used to analyze the seismic behavior of suspen-domes and a new criterion is established for judging the seismic failure based on a characteristic point in the SED model. Firstly, a nonlinear time-history response analysis was carried out using the finite-element package ANSYS for typical suspen-domes subjected to different ground motions. The seismic responses including nodal displacements, ratios of yielding members, strain energy density and structural maximum deformation energy were extracted corresponding to the increasing peak ground acceleration (A). Secondly, the SED sum ($I_d$) was calculated which revealed that the $I_d-A$ curve exhibited a relatively large change (called a characteristic point) at a certain value of A with a very small load increment after the structures entered the elastic-plastic state. Thirdly, a SED criterion is proposed to judge the seismic failure load based on the characteristic point. Subsequently, the case study verifies the characteristic point and the proposed SED criterion. Finally, this paper describes the unity and application of the SED criterion. The SED method may open a new way for structural appraisal and the SED criterion might give a unified criterion for predicting the failure loads of various structures subjected to dynamic loads.

Analysis of Applicability in the Public Transportation System considering the Cost-volume Supply Curve of New Transit System Bi-Modal Tram (녹색 신교통 시스템 바이모달트램의 비용-수요 공급곡선을 고려한 도시 대중교통체계 적용 특성 분석)

  • Kim, Hong-Seok;Kim, Ryang-Gyun;Ham, Jae-Hyun;Jeon, Jae-Cheong;Yoon, Hee-Taek
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2303-2308
    • /
    • 2010
  • We studied the cost-volume supply characteristic of public transportation systems focused on Bi-modal Tram in the main cities to analyze the applicability and status for the new transit system Bi-modal Tram as public transportation system. The operation cost considering the characteristic of vehicle, facilities, operation and average cost for respective public transportation system and the time cost considering the travel and transfer time are defined to the social cost, and the cost-volume supply curve is based on this social cost. The cost-volume supply characteristic between public transportation modes in the city is determined on the basis of cost-volume supply curve. Through the comparison between cost-volume supply characteristic of main transportation systems, it is analyzed about the relation between public transportation systems in the city and the characteristic for proper service provision. The application of Bi-modal Tram in the city is concluded that it is effective to reduce the social cost on the existing public transportation system.

  • PDF

The Study of Job Stress in Occupational Therapist (작업치료사의 직무 스트레스에 관한 연구)

  • Yang, Young-Ae;Hur, Jin-Gang;Noh, Young-Man;Lee, Gyu-Chang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.1-9
    • /
    • 2007
  • The purpose of this study was going to research relation of job stress and society psychologic stress according to general characteristic, work characteristic, health characteristic and personality characteristic for the occupational therapist in the working domestic rehabilitation therapy with hospital and welfare center occupational therapist. The research was 91 of withdrawal questionnaire among 102 occupational therapist from 1. November 2005 to 31. December 2005. In the result of analysis the given question for the ninety one occupational therapist showed just normal group 25% 23 person, potential stress group 47% 43 person, and the rest 28% 25 person high risk group. The result shows significance different in general characteristic of job stress about age, final scholarship and marriage. Job stress was included income, working time, office form and working position etc. Health special job stress was significance different according to sleep time. So we have to know a fact of job stress of occupational therapist and prevent of loss of business services. And we have to endeavoring removals factor of stress and good office culture fixation.

Transient Response of an Electrorheological Fluid in Shear Flow (전단 유동 하에서 전기유변유체의 과도응답 특성)

  • Choi, Byung-Ha;Nam, Yun-Joo;Park, Myeong-Kwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.411-417
    • /
    • 2009
  • The transient shear stress response of an electrorheological fluid is investigated experimentally. The characteristic time constants of an electrorheological fluid sheared between two concentric cylinders were obtained under various electric field strengths and shear rates. Also, two experimental modes are adopted to investigate the effect of the shear flow on the dynamic behavior of the fluid; one is that the electric field is induced before shearing, and the other is the electric field is induced after shearing. From the difference in the response time between two modes, the cluster formation time were obtained. The response times were decreased with the increase of the shear rate, irrelatively of the electric field strength. The cluster formation time were monotonically increased with increase of shear rate, and thereafter, were converged with a certain value.

A Study on Characteristic of Sedimentation-Consolidation Conduct for Dredged Soil through Geo-Centrifuge Test (원심모형실험을 이용한 준설토의 침강압밀 거동 특성)

  • Park, Hyunchul;Kang, Hongsig;Sun, Seokyoun;Park, Jongseo;Ahn, Kwangkuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.2
    • /
    • pp.59-65
    • /
    • 2017
  • The costal reclamation construction is for making reclaimed land by dredging marine clay with seawater, and then bringing the dredged soil into the reclaimed land. During the process, the dredged soil in the reclaimed land undergoes the sedimentation-consolidation process. Among the processes, the consolidation is a very critical factor when planning reclaimed land because of its requiring time and settlement. In order to predict the requiring time and settlement, the Column test, which was suggested by Yano, has been usually used in the nation. However, the test method needs a very long time to identify the characteristic of sedimentation-consolidation of dredged soil. Therefore, in this study, in order to supplement the weakness of the Column test which needs such a long time, and in order to identify the characteristic of the sedimentation-consolidation for dredged soil in a short time, the Geo-centrifuge test was examined as an alternative method. The result considered that Geo-centrifuge test would be useful to identify the characteristic of sedimentation-consolidation for dredged soil efficiently.

Prediction of Sludge-Water Interface Height Change in Batch Column (Batch Column에서의 슬러지계면층 높이변화 예측)

  • Park, Suk Gyun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.156-163
    • /
    • 2006
  • While sludge is settling in batch column, sludge concentration becomes high. Because the characteristic of sludge settling changes in function of time due to the sludge concentration change, the sludge settling velocity changes too. Also, because the sludge settling characteristic is influenced by a physical characteristic of sludge and a column height etc, it is difficult to exactly measure the sludge settling characteristic. Although the sludge volume indexes, SVI, SSVI and $SSVI_{3.5}$, are used to predict sludge settling characteristic, these indexes are not reliable values. Because the previously established models for sludge settling velocity predict the sludge settling velocity only, it is difficult to predict sluge-water interface height by using those models. The purpose of this experiment is to establish the empirical model which predicts the sludge interface height change with respect to the sludge physical characteristic and the settling condition.

A study on the effect of inverter nonlinear characteristic on the flux estimation of an induction motor (인버터의 비선형 특성이 유도전동기의 자속 추정에 미치는 영향에 대한 연구)

  • Kim, Sang-Hoon;Kim, Tae-Suk
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.167-174
    • /
    • 2008
  • In this paper, the analysis on type effect of inverter output voltage distortion on the control of an induction motor is discussed. The inverter output voltage is distorted differently from the reference voltage owing to the inverter nonlinear characteristic. The inverter nonlinear characteristic results from the voltage drop, the inherent characteristic of the power semiconductor, and the dead time for preventing the short circuit of the inverter leg. This characteristic distorts the inverter output voltage and then, causes the motor flux estimation error. Although this characteristics do not significantly effect in the general-purpose induction motor control, but significantly effect on the low-speed operation of high performance motor control such as the sensorless vector control.

  • PDF