• Title/Summary/Keyword: Characteristic simulator

Search Result 268, Processing Time 0.031 seconds

Study on Coupling Characteristics between TE01δ Mode Dielectric Resonator and Coplanar Waveguide Structure (TE01δ 모드 유전체 공진기와 코플래나 웨이브가이드 구조들과의 결합 특성 연구)

  • Kim, Jong-Hyuk;Kim, Ihn S.
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.2
    • /
    • pp.147-155
    • /
    • 2005
  • In this paper, we propose that three uniform coplanar waveguides(CPWs), such as a conventional, finite grounded(FG), and grounded(G) CPWs, can be coupled with a $TE_{01{\delta}}$ mode dielectric resonator(DR) for a parallel resonant characteristic as a microstrip line coupled with the DR. Coupling characteristics have been investigated by placing the DR on a dielectric support above the CPWs and by moving the DR away from the center of a slot of the CPWs to the ground plane. FEM simulation(HFSS) results in terms of S-parameters agree well with measurement results. Finally, unloaded Q values of the DR coupled with the three uniform CPWs are compared with those of the DR coupled with a microstrip line. The comparison shows that the DR coupled with the three CPWs has higher unloaded Qs than that coupled with a microstrip line and that the GCPW case has the highest unloaded Qs.

  • PDF

Development of Galileo E5 Signal Receiving Software for AltBoc Signal Modulation (AltBOC 변조 특성을 활용한 Galileo E5 신호 수신 소프트웨어 개발)

  • Jeon, Sang-Hoon;So, Hyoung-Min;Lee, Taik-Jin;Kim, Ghang-Ho;Jeon, Seung-Il;Kim, Chong-Won;Kee, Chang-Don;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.9
    • /
    • pp.855-862
    • /
    • 2009
  • This paper contains the signal receiving algorithm for Galileo E5 AltBOC signal and the development of Galileo E5 signal receiving software. The software runs the process from signal acquisition to extracting measurement data to get navigation solution. It uses logged IF data file as an input. In signal acquisition stage, 1ms and delayed 1ms data are used for reducing correlation ross from secondary code and navigation bit conversion. Signal tracking stage is made of two stages which are coarse tracking and fine tracking. It is for taking advantage of AltBOC characteristic and resolving ambiguity problem due to BOC modulation. The functions of software are verified by signal processing using logged IF data from commercial GNSS simulator.

Characteristic Study of the Pulse Position on CHON, KWAN and CHUCK Using the Ultrasonic Waves (초음파 분석을 이용한 촌관척 위치별 혈관의 특성연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Ryu, Hyun-Hee;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-117
    • /
    • 2007
  • The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women(22.28${\pm}$2.62 age) considered normal in terms of Body Mass Index(BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value. Results showed there is a statistically significant difference among the variables measured on CHON, KWAN and CHUCK. A difference according to gender was also observed. This explains why an oriental medical doctor can tell the difference in pulses depending on the location of CHON, KWAN and CHUCK. In addition, the difference in pressure between CHON and KWAN was higher than that in pressure between KWAN and CHUCK. The findings explain why oriental medical doctors take pulses by dividing CHON, KWAN and CHUCK in the short length of the three fingers. It can be used to develop a pulse diagnosis device enabling accurate measurement according to the characteristics of blood vessel structure based on where the pulse is taken. Furthermore, the results can be used as basic data for the development of a pulse diagnosis simulator.

  • PDF

Study on the IPMC electrical characteristic change For the utilization of Ocean Current Energy (해양 에너지 활용을 위한 IPMC의 전기적 특성 변화 연구)

  • Son, Kyung Min;Kim, Min;Kim, Gwan-Hyung;Kim, Hyun-jo;Byun, Gi-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.531-533
    • /
    • 2013
  • In this paper, to study the IPMC (Ionic exchange Polymer Metal Composite) material consisting of a sulfonic acid ion and fluoride combination of carbon with Nafion film greatly affected the electro-active polymer (Electro Active Polymer) characteristics and the presence of water and cationshave properties. Use or electrical energy into mechanical energy, mechanical energy, electrical energy, and can be utilized to its characteristics, depending on the water and cations in water varies greatly. Configure the device simulations in order to study the electrical properties of these IPMC. Stepper Motor using MCU and simulator designed for the electrical characterization due to the movement and to the implementation of the mechanical movement of ocean currents. In this study, configuration the IPMC and simulation device to the area of the IPMC to the efficient use of energy currents, frequency, salinity concentration, through the efficient use of the IPMC due to the bend angle of the electrical analysis and research methods we propose.

  • PDF

Material Characteristics of Dental Implant System with In-Vitro Mastication Loading

  • Jeong, Tae-Gon;Jeong, Yong-Hun;Lee, Su-Won;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Gang, Gwan-Su
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.72-72
    • /
    • 2018
  • A dynamic fatigue characteristic of dental implant system has been evaluated with applying single axial compressive shear loading based on the ISO 14801 standard. For the advanced dynamic fatigue test, multi-directional force and motion needed to be accompanied for more information of mechanical properties as based on mastication in oral environment. In this study, we have prepared loading and motion protocol for the multi-directional fatigue test of dental implant system with single (Apical/Occlusal; AO), and additional mastication motion (Lingual/Facial; LF, Mesial/Distal; MD). As following the prepared protocol (with modification of ISO 14801), fatigue test was conducted to verify the worst case results for the development of highly stabilized dental implant system. Mechanical testing was performed using an universal testing machine (MTS Bionix 858, MN, USA) for static compression and single directional loading fatigue, while the multi-directional loading was performed with joint simulator (ADL-Force 5, MA, USA) under load control. Basically, all mechanical test was performed according to the ISO 14801:2016 standard. Static compression test was performed to identify the maximum fracture force with loading speed of 1.0 mm/min. A dynamic fatigue test was performed with 40 % value of maximum fracture force and 5 Hz loading frequency. A single directional fatigue test was performed with only apical/occlusal (AO) force application, while multi directional fatigue tests were applied $2^{\circ}$ of facial/lingual (FL) or mesial/distal (MD) movement. Fatigue failure cycles were entirely different between applying single-directional loading and multi-directional loading. As a comparison of these loading factor, the failure cycle was around 5 times lower than single-directional loading while applied multi-directional loading. Also, the displacement change with accumulated multi-directional fatigue cycles was higher than that of single directional cycles.

  • PDF

A Study on Modeling of Fighter Pilots Using a dPCA-HMM (dPCA-HMM을 이용한 전투기 조종사 모델링 연구)

  • Choi, Yerim;Jeon, Sungwook;Park, Jonghun;Shin, Dongmin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.1
    • /
    • pp.23-32
    • /
    • 2015
  • Modeling of fighter pilots, which is a fundamental technology for war games using defense M&S (Modeling & Simulation) becomes one of the prominent research issues as the importance of defense M&S increases. Especially, the recent accumulation of combat logs makes it possible to adopt statistical learning methods to pilot modeling, and an HMM (Hidden Markov Model) which is able to utilize the sequential characteristic of combat logs is suitable for the modeling. However, since an HMM works only by using one type of features, discrete or continuous, to apply an HMM to heterogeneous features, type integration is required. Therefore, we propose a dPCA-HMM method, where dPCA (Discrete Principal Component Analysis) is combined with an HMM for the type integration. From experiments conducted on combat logs acquired from a simulator furnished by agency for defense development, the performance of the proposed model is evaluated and was satisfactory.

A Study on Hand-signal Recognition System in 3-dimensional Space (3차원 공간상의 수신호 인식 시스템에 대한 연구)

  • 장효영;김대진;김정배;변증남
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.3
    • /
    • pp.103-114
    • /
    • 2004
  • This paper deals with a system that is capable of recognizing hand-signals in 3-dimensional space. The system uses 2 color cameras as input devices. Vision-based gesture recognition system is known to be user-friendly because of its contact-free characteristic. But as with other applications using a camera as an input device, there are difficulties under complex background and varying illumination. In order to detect hand region robustly from a input image under various conditions without any special gloves or markers, the paper uses previous position information and adaptive hand color model. The paper defines a hand-signal as a combination of two basic elements such as 'hand pose' and 'hand trajectory'. As an extensive classification method for hand pose, the paper proposes 2-stage classification method by using 'small group concept'. Also, the paper suggests a complementary feature selection method from images from two color cameras. We verified our method with a hand-signal application to our driving simulator.

A Study on Ship Evacuation Safety Consequent on the Size and Sort of Fire (화재의 크기와 종류에 따른 선박 피난 안전 연구)

  • KIM, Won-Ouk;KIM, Dae-Hee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1358-1364
    • /
    • 2016
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crewmen are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. According to the ship fire survey, about 50% of the total fire accidents occurred at an engine room, and the main fire origin was analyzed to be oil. In addition, ship fire breaks out in the order of baggage racks and living quarter. In short, the survey indicates that all sorts of fires belonging to A, B, C and D-class have occurred. This study, targeting an actual passenger ship 'A', found the response time to evacuation, during which the people on board a ship recognize the outbreak of fire, and act, and the travel time for evacuation which is the actual travel time. In addition, this study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of passengers and crew based on the collected simulation data by fire size and sort. As a result of the analysis, it was found that when examining the only actual evacuation movement time excepting the response time to evacuation, people are safe by completing evacuation before the effective evacuation time only in case fire size is 100Kw among all sorts of fires. In other words, in case of the outbreak of fire more than 1 MW, it was found to fail to meet evacuation safety regardless of fire size.

Analysis of SCR, MVSCR, LVTSCR With I-V Characteristic and Turn-On-Time (SCR, MVSCR, LVTSCR의 Turn-on time 및 전기적 특성에 관한 연구)

  • Lee, Joo-Young
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.295-298
    • /
    • 2016
  • In this paper, we analysed the properties of the conventional ESD protection devices such as SCR, MVSCR, LVTSCR. The electrical characteristics and the turn-on time properties are simulated by Synopsys T-CAD simulator. As the results, the devices have the holding voltages between 2V and 3V, and the trigger voltage of about 20V with SCR, of about 12V with MVSCR, of about 9V with LVTSCR. The results of the simulation for the turn-on time properties are 2.8ns of SCR, 2.2ns of MVSCR, 2.0ns of LVTSCR. Thus, we prove that LVTSCR has the shortest turn-on time. However, the second breakdown currents(It2) of the devices are 7.7A of SCR, 5.5A of MVSCR, 4A of LVTSCR. This different properties have to be adapted by the operation voltages for I/O Clamps.

High Power Amplifier Design and Fabrication for Tactical Data Link (전술데이터링크용 고출력증폭기 설계 및 제작)

  • Kim, Jong-Sung;Bae, Moon-Kwan;Kim, Joo-Yeon
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.338-347
    • /
    • 2017
  • This paper describes the design and fabrication of a high power amplifier which is a component of TDL(Tactical Data Link) aircraft terminal. We applied high-speed frequency hopping technology, cognitive radio technology, and receive filter bank technology to efficiently use limited frequency resources with radar and other communication equipment using the same frequency band. The high-power amplifier is physically composed of a transmitter, a receiver, a mechanical part, and a cable assembly, and is designed to meet temperature characteristics and electrical characteristics such as maximum transmission distance and reception sensitivity. Modeling and simulator were used to satisfy the requirement of high power amplifier. The transmit power and the noise figure were measured at 50.02dBm and 2.682dB, respectively. It was confirmed that all the required specifications were satisfied in the electrical characteristics test and the environmental characteristic test.