• Title/Summary/Keyword: Characteristic scale

Search Result 1,151, Processing Time 0.032 seconds

Study on Performance Characteristics of Reduced-Scale Lead Rubber Bearings with Three different Diameters of Lead Pluge (직경이 다른 납을 삽입한 축소규모 면진베어링의 성능특성비교)

  • Yoo, Bong;Lee, Jae-Han;Koo, Gyeong-Hoi
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.328-334
    • /
    • 1998
  • The characteristic tests for the reduced-scale lead rubber bearings are performed with three different diameters of lead plugs. The test frequencies are 0.05Hz and 0.5Hz of the sinusoidal waves. The roles of lead plugs in the behavior of lead rubber bearings are investigated. The shear-deformation characteristic values such as stiffness, damping and yield load values are increased according to the increase of the diameter of lead plugs. The high damping value can be obtained by increasing the diameter of lead plug.

  • PDF

MHD turbulence in expanding/collapsing media

  • Park, Jun-Seong;Ryu, Dong-Su;Cho, Jung-Yeon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.85.2-85.2
    • /
    • 2011
  • We investigate the driven magnetohydrodynamic (MHD) turbulence by including the effect of the expansion and collapse of background medium. The main goal is to quantify the evolution and saturation of the strength and characteristic length scales of magnetic fields in expanding and collapsing media. Our findings are as follows. First, with the expansion and collapse of background medium, the time evolution of the magnetic and kinetic energy densities depends on the nature of forcing as well as the rate of expansion and collapse. Second, at scales close to the energy injection (or driving) scale, the slope of magnetic field power spectrum shallows with expansion but steepens with collapse. Third, various characteristic length scales, relative to the energy injection scale, decrease with expansion but increase with collapse. We discuss the astrophysical implications of our results.

  • PDF

Degree of Cognitive function, Self-esteem and Depression of the Elderly by Aging (노인의 인지기능, 자아존중감과 우울정도)

  • 성기월
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.1
    • /
    • pp.36-48
    • /
    • 1997
  • This survey was performed to evaluate and compare cognitive function, self-esteem and depression in the elderly related to aging. The data were collected from 200 elders in eight homes for the elderly in Taegu. Data collection was done from June 1 to 31, 1996. The scale used to measure cognitive function was the MMSE-K(Mini-Mental State Examination-Korea), Self-esteem was measmed using Rosenberg's self-esteem scale and depression using SDS(Self-rating Depression Scale). A comparison of cognitive function, self-esteem and depression by aging were summarised as follows : 1. There were significant differences on the cognitive function score in the elderly according to age group(F=24.81, P<.01). 2. There were significant differences on the self-esteem score in the elderly according to age group(F=3.84, P<.5). 3. There were significant differences on the depression score in the elderly according to age group (F=5.90, P<.1). 4. The general characteristics which affected the cognitive function scores of the elders were sex (F=8.45, P<.5), educational level(F=8.86, P<.5), spousing(F=34.59. P<.01), and the perception of health(F=4.63, P<.5). 5. The general characteristic which affected the self-esteem scores of the elders was the perception of health(F=3.81. P<.5). 6. The general characteristic which affected the depression scores was the educational level(F=3.96, P<.5).

  • PDF

A Study on the Heat Release Characteristic of Household Items using LSC(Large Scale Cone Calorimeter) (LSC를 이용한 생활용품의 발열량 특성에 관한 연구)

  • Park, Ju Young;Baek, Chang Sun;Lee, Hae Pyeong;Hong, Yi Pyo
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.38-44
    • /
    • 2015
  • For this study, fire tests were performed targeting household items (Sofa, Drawer, Refrigerator, Washing machine) using a large cone calorimeter (Large Scale Cone Calorimeter, LSC). The data were obtained focusing on the fire characteristic of the data when the actual fire occurs. The study results showed the following mean HRR of the household items; drawer 2843 KW, sofa 2939 KW, washing machine 719 KW, refrigerator 2907 KW, and THR is found in sofa 2202 MJ, drawer 1559 MJ, refrigerator 1193 MJ, washing machine 627 MJ. From the result, it could be found that the sofa can cause significant heat generation when the fire occurs, and the flashover tendency was found relatively high in compartment fire. In addition, a weight of the four our household items was reduced sharply in a similar time (20min before and after) degree after ignition. The drawer and sofa which has a high heat release can be considered to speed up the fire spread as their weight decrease rapidly and showed relatively weak to the fire compared to the refrigerator and washing machine.

A Study on the Customer Voltage Characteristic of Distribution System with Large Scale PV (대용량 태양광발전이 연계된 배전계통의 수용가 전압 특성해석에 관한 연구)

  • Kim, Byung-Ki;Ryu, Kyung-Sang;Kim, Chan-Hyeok;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • This paper deals with the analysis of the customer voltage characteristic in distribution system interconnected with large scale PV system. There would be many power quality issues which are caused by reverse power flow of PV system interconnected with distribution system. In order to analyze the effect of PV system on the customer voltage, detailed modeling method of distribution system and modified modelling method of PV system are proposed using PSCAD/EMTDC in this paper. So far, less than dozens KW of PV system can be simulated with the existing modelling method. Therefore, a new modeling method which can simulate the large scale PV system is proposed by considering the relationship equation on the phase and voltage in the current control algorithm. From the simulation result of proposed modelling method, it is confirmed that an optimal operation method in distribution system is suggested by analyzing the effect of PV system on customer voltage.

Investigation of Large-scale Transmission Tower Grounding Grid with High Amplitude and Uniform Flowing Impulse Current

  • Yang, Shuai;Huang, Jiarui;Wei, Shaodong;Zhou, Wenjun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2050-2058
    • /
    • 2018
  • Impulse characteristic of transmission tower grounding grid is needed for lightning protection of transmission line. This paper describes an outdoor experimental test facility established for large-scale grounding grid of transmission tower, made up of four impulse current generators and a circle current return electrode. The amplitude of impulse current is up to 100 kA. The results of the CDEGS simulation and GPR measurement reveal the uniform current distribution in the test arrangement. An impulse test for a square electrode with extended conductors is carried out in condition of three current waveforms with different amplitude. Based on the electrical network model and iterative algorithm method, a calculation model is proposed to simulate the impulse characteristic of large-scale grounding grid considering soil ionization. The curve of impulse resistance against the current amplitude shows the soil ionization both from the simulation and test. Deviation between the simulation and test result is less than 15%.

Analysis of Performance Characteristic for Small Scale Hydro Power Plant with Long Term Inflow Condition Change (장기유입량 변화에 의한 소수력발전소 성능특성분석)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.39-43
    • /
    • 2009
  • The variation of inflow at stream and hydrologic performance for small scale hydro power(SSHP) plants due to climate change have been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the variation of inflow caused from rainfall condition. And another model to predict hydrologic performance for SSHP plants is established. Monthly inflow data measured at Andong dam for 32 years were analyzed. The existing SSHP plant located in upstream of Andong dam was selected and analyzed hydrologic performance characteristics. The predicted results from the developed models show that the data were in good agreement with measured results of long term inflow at Andong dam and the existing SSHP plant. Inflow and ideal hydro power potential had increased greatly in recent years, however, these did not lead annual energy production increment of existing SSHP plant. As a results, it was found that the models represented in this study can be used to predict the primary design specifications and inflow of SSHP plants effectively.

  • PDF

A test for friction and wear characteristic of brake disk materials (제동디스크 소재의 마찰-마모특성 시험)

  • Lim, Choong-Hwan;Goo, Byeong-Choon
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1761-1765
    • /
    • 2008
  • In the braking of a railroad car, mechanical brake systems using wheel tread and brake disk are applied as well as electrical brake systems by regenerator and rheostat. It is very important to consider the frictional characteristic because kinetic energy of the vehicle is dissipated as converted thermal energy through friction between disk and brake pad during disk braking. A friction coefficient and wear characteristic are decided from the interrelationship of disk and friction material in the disk brake system. Lab-scale dynamometer test on developed brake disk materials for increasing heat resistance was performed in this study. Each candidate material was tested at various braking speeds and pressures and we obtained the friction coefficient and wear characteristic. And we executed comparative evaluation of the result from the test.

  • PDF

A Large-scale Structural Mixing Model applied to Blowout of Turbulent Nonpremixed Jet Flames in a Cross air-flow

  • Lee, Kee-Man;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.163-173
    • /
    • 1997
  • This article presents an application of a large-scale structural mixing model (Broadwell et al. 1984) to the blowout of turbulent reacting jets discharging perpendicularly into an unconfined cross air-flow. In an analysis of a common stability curve, a plausible explanation can be made that the phenomenon of blowout is related only to the mixing time scale of the two flows. The most notable observation is that the blowout distance is traced at fixed positions at all times according to the velocity ratio R. Measurements of the lower blowout limits in the liftable flame agree qualitatively with the blowout parameter ${\varepsilon}$, proposed by Broadwell et al. Good agreement between the results calculated by a modified blowout parameter ${\varepsilon}^'$ and experimental results confirms the important effect of a large-scale structure in specifying the stabilization feature of blowouts.

  • PDF