• Title/Summary/Keyword: Characteristic radiation

Search Result 604, Processing Time 0.036 seconds

Bandwidth Prediction for the Rectangular Planar Monopole Antenna by Radiation Mode Identification (복사 모드 해석에 의한 사각형 평면 모노폴 안테나의 대역폭 예측)

  • Chun, Joong-Chang;Shim, Jae-Ruen;Kim, Tae-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.1
    • /
    • pp.70-74
    • /
    • 2015
  • In this paper, we have illuminated the radiation modes of rectangular planar antennas to interpret the nature of the wideband characteristic upon which formulas for bandwidth prediction are presented. Rectangular planar antennas are being investigated by many researchers in virtue of relatively simple design and fabrication procedures to replace the cylindrical monopoles. But the design principle for rectangular planar antennas is still based on that of cylindrical monopoles, and the nature of the wideband characteristic and the formula to estimate the upper band frequency are not analyzed yet. In this research, we have shown the patterns of the radiation modes explaining the wideband characteristic and also proposed the upper band frequency with minor modification for the lower band frequency formula based on mode formation principles. Finally we have confirmed the validity of our results, within 10 % accuracy, by the application to some published results.

Comparison of Temperature Distribution in Agar Phantom and Gel Bolus Phantom by Radiofrequency Hyperthermia

  • Jung, Dong Kyung;Kim, Sung Kyu;Lee, Joon Ha;Youn, Sang Mo;Kim, Hyung Dong;Oh, Se An;Park, Jae Won;Yea, Ji Won
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.224-231
    • /
    • 2016
  • The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with that of the Gel Bolus phantom under conditions similar to those of an agar phantom that can continuously carry out temperature measurement. The temperatures of the agar phantom and the Gel Bolus phantom were raised to $36.5{\pm}3^{\circ}C$ and a temperature sensing was inserted at depths of 5, 10, and 15 cm from the phantom central axis. The temperature increase rate and the coefficient of determination were analyzed while applying output powers of 100 W and 150 W, respectively, at intervals of 1 min for 60 min under conditions where the indoor temperature was in the range $24.5{\sim}27.5^{\circ}C$, humidity was 35~40%, internal cooling temperature of the electrode was $20^{\circ}C$, size of the upper electrode was 250 mm, and the size of the lower electrode was 250 mm. The coefficients of determination of 150 W output power at the depth point of 5 cm from the central axis of the phantom were analyzed to be 0.9946 and 0.9926 in the agar and Gel Bolus phantoms, respectively; moreover, the temperature change equation of the agar and Gel Bolus phantoms with time can be expressed as follows in the state the phantom temperature is raised to $36^{\circ}C:Y(G)$ is equation of Gel Bolus phantoms (in 5 cm depth) applying output power of 150 W. Y(G)=0.157X+36. It can be seen that if the temperature is measured in this case, the Gel Bolus phantom value can be converted to the measured value of the agar phantom. As a result of comparing the temperature distribution characteristics of the agar phantom of a human-body-equivalent material with those of the Gel Bolus phantom that can be continuously used, the usefulness of Gel Bolus phantom was exhibited.

Design of a radiation-tolerant I-gate n-MOSFET structure and analysis of its characteristic (I 형 게이트 내방사선 n-MOSFET 구조 설계 및 특성분석)

  • Lee, Min-woong;Cho, Seong-ik;Lee, Nam-ho;Jeong, Sang-hun;Kim, Sung-mi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1927-1934
    • /
    • 2016
  • In this paper, we proposed a I-gate n-MOSFET (n-type Metal Oxide Semiconductors Field Effect Transistor) structure in order to mitigate a radiation-induced leakage current path in an isolation oxide interface of a silicon-based standard n-MOSFET. The proposed I-gate n-MOSFET structure was designed by using a layout modification technology in the standard 0.18um CMOS (Complementary Metal Oxide Semiconductor) process, this structure supplements the structural drawbacks of conventional radiation-tolerant electronic device using layout modification technology such as an ELT (Enclosed Layout Transistor) and a DGA (Dummy Gate-Assisted) n-MOSFET. Thus, in comparison with the conventional structures, it can ensure expandability of a circuit design in a semiconductor-chip fabrication. Also for verification of a radiation-tolerant characteristic, we carried out M&S (Modeling and Simulation) using TCAD 3D (Technology Computer Aided Design 3-dimension) tool. As a results, we had confirmed the radiation-tolerant characteristic of the I-gate n-MOSFET structure.

Characteristic analysis of solar radiation and atmospheric transmissivity at Chupungryeong (추풍령의 일사량과 대기투과율의 특성 분석)

  • Park, Jin Ki;Kim, Bong Seop;Park, Jong Hwa
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.2
    • /
    • pp.149-155
    • /
    • 2014
  • The surface solar radiation is an important indicators for climate and agricultural research over the Earth system. For the climate and agricultural research, long-term meteorological data and accurate measured data are needed. The daily solar radiation from Jan. 2001 to Dec. 2010 have been employed in this study analyze atmospheric transmissivity for Chupungryeong. The corresponding daily value of atmospheric transmissivity is calculated for Chupungryeong meteorological data. In this paper, relationship analysis of daily solar radiation and atmospheric transmissivity is presented. It shows that atmospheric transmissivity over late December peaked in the 2000s, substantially decreased from the early-January, and changed little after that in summer. Reduction of solar radiation caused a reduction of more than 0.3 in atmospheric transmissivity during July to August. It was concluded that the atmospheric transmissivity could be very useful for evaluating solar radiation. Atmospheric transmissivity approach is suitable for daily-term simulation studies and useful for computing solar radiation.

Distribution and Variation Characteristic of Solar Radiation Resources in Korea (국내 태양복사 분포 및 변화특성)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.1-200.1
    • /
    • 2010
  • Solar energy is one of the most promising energy resources in the future. For the application and dissemination of solar energy technologies in various fields, reliable data sets of solar irradiation are needed for engineers, researchers, businessmen, and policy makers. Global horizontal solar radiation is needed for the use of flat plate collector, solar domestic hot water system, photovoltaic devices and passive systems like green house. In many countries, solar radiation data accumulated for more then 40 or 50 years and typical weather data are published with average of more then 30 years. In Korea, those global total radiations are measured for about 30 years. With the connections of computer network, measured data could be transmitted to the central control system at key station through Ethernet lines. The data acquisition systems are connected to be automatically controlled by the monitoring network. Global horizontal solar radiation data 16 locations were measured and averaged from 1982 to 2008.

  • PDF

Development of p-MOSFET Type Accumulated Radiation Dose Monitoring Sensor (p-MOSFET 타입 방사선 누적선량 모니터링 센서 개발)

  • 이남호;최영수이용범육근억
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.597-600
    • /
    • 1998
  • When a semiconductor(pMOSFET) sensor is exposed to ionizing radiation, electrons/holes are generated in its oxide layer. By the phenomenon of hole traps in oxide layer during their move, the characteristics of semiconductor is changed. This paper describes the output characteristic changes of two kind of pMOSFET(domestic, japan) after C0-60 ${\gamma}$-irradiation on them for their application as radiation accumulated dose monitoring sensors. We found the threshold voltage shifts (VT) of pMOSFETs in proportion to irradiated radiation dose and their linear properties. These results make us confirm that we will be able to develop good accumulated radiation dose monitoring sensors.

  • PDF

Acute Radiation Syndrome in an Irradiated Minipig Model for Patients with Radiation Exposure

  • Jang, Hyosun;Kim, Joong-sun;Shim, Sehwan;Jang, Won-seok;Lee, Sun-Joo;Myung, Jae Kyung;Lee, Seung-Sook;Park, Sunhoo
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.3
    • /
    • pp.146-153
    • /
    • 2017
  • Background: Acute radiation syndrome (ARS) primarily refers to damage to the hematopoietic system, myeloid system, and gastrointestinal (GI) system caused by radiation exposure. Such damage progresses to become life-threatening. In particular, as the syndrome develops very rapidly-within several hours from radiation exposure-prompt and accurate diagnosis and treatment are needed, as is further research into appropriate diagnostic and treatment modalities. Materials and Methods: Minipigs, which display human-like properties, underwent whole-body irradiation at 2 or 4 Gy (doses causing hematopoietic ARS) or at higher doses of 7 or 12 Gy. Changes in the blood cells and clinical symptoms were analyzed and we performed a necropsy when the animals succumbed to ARS. Results and Discussion: The minipig irradiated with 2 Gy showed a decrease in white blood cells, including neutrophils, lymphocytes, and platelets in the early stages. However, the blood cell counts gradually increased and returned to normal values. The minipig irradiated with 4 Gy succumbed due to hematopoietic ARS. In contrast, the minipigs irradiated with 7 or 12 Gy exhibited clinical symptoms of combined GI damage and hematopoietic syndrome. Moreover, a characteristic pattern of platelet changes was observed in the 7 and 12 Gy irradiated minipigs. Conclusion: The changes in the platelet count caused by radiation exposure observed in minipigs, which are hematologically and pathohistologically similar to humans, suggest that they can be used as a novel diagnostic criterion.

The Characteristic of Radiation Exposure for Radiologist with Applying Condition in Interventional Radiology in Cardiology (심장내과의 중재적 시술시 시술조건에 따른 방사선사의 방사선 노출 특성)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.3
    • /
    • pp.421-429
    • /
    • 2012
  • Lately, the number of interventional radiology is increased by the extension of procedure in medical radiation, and radiation exposure may be appeared differently by interventional radiologists, it is caused increase of radiation dose for radiation worker, patient, and radiologists. This study has done a comparative analysis characteristic of radiation exposure for five radiologists who executed interventional cardiology for 303 patients in S university hospital of Gyeong-Buk from Nov. 1, 2011 to Jan. 31, 2011. The average exposure time of five radiologists was 697.95sec. The average of cumulative DAP(exp) for patients was $52,730mGycm^2$ and the average of total DAP for patients was $104,875.14mGycm^2$. The average of frames for image was 855.52 frames in acquired images, and the average of frames for images was 802.2 frames in exposure images. They were statistically significant differences (p<0.05). Exposure time, cumulative DAP(fluro), cumulative DAP(exp), total DAP, acquired image, and exposure image were high correlation except cumulative DAP(exp), and acquired runs in x-ray exposure characteristics of machine. Exposure time was a great influence on radiologist. It signified that the more exposure time lead to the more radiation dose for radiologist. Radiation dose is related to ability, experience, difficulty, and precision of procedures in interventional procedure. The number of angiography and exposure time is difficult to control by radiologists. Therefore, it is in need of reasonable system which was evaluated the real dose of medical teams in interventional proceedings. We think that self education and training are required to reduce radiation dose for radiologists and radiation workers.

Observation and Analysis of the Long and Short Wave Radiation According to Different Altitudes and Locations in Daegu During Summer (대구지역의 고도와 위치에 따른 하절기 장·단파복사 관측과 해석)

  • Choi, Dong-Ho;Lee, Bu-Yong;Oh, Ho-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.71-81
    • /
    • 2012
  • This study for the understanding of the radiation environment according to the altitude in urban area in the summer observes the long and short wave radiation environment at the 4 urban areas with different height and the 1 suburban area. The results of this study are as follows. (1) When the altitude was high, the more short wave radiation was observed. (2) As the altitude was high, the temperature of atmosphere got lower. And because of that the downward long wave radiation was also lower. This general trend was confirmed through the study. (3) Through the observation of long wave radiation, the upper atmosphere of suburban area had the atmosphere characteristic which the temperature was rising and decreasing faster. Therefore, the difference radiation characteristics between the urban and suburban area were confirmed. (4) The result of the ratio of short wave radiation to long wave radiation(short wave radiation/long wave radiation) according to the altitude and location, the value was increased when the distance was far from the artificiality structure or a heat source, and the urban effect became smaller. Thus, it is expected that the ratio will be an evaluation index for evaluating urbanization effect.

A Study on the Characteristic of the $^6Li$ Neutron Spectrometer ($^6Li$ 중성자분광계 특성 연구)

  • Choe, Seong-Ho;Kang, Sam-Woo;Lee, Kwang-Pill;Lee, Kyung-Ju;Hwang, Sun-Tae
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.57-61
    • /
    • 1992
  • For the neutron spectrum measurement, $^6Li$ neutron spectrometer system is installed. The characteristic of the $^6Li$ detector are investigated using a $^{137}Cs$ and $^{207}Bi$ point source, and the neutron capture peaks and the pulse height spectrum using an $^{214}Am-Be$ neutron source are measured. Furthermore, the pulse height spectrum for the irradiation time variation from the (214)^Am-Be neutron source, and for the distance variation between detector and source, and the threshold variation of discriminator are measured.

  • PDF