• 제목/요약/키워드: Characteristic radiation

검색결과 614건 처리시간 0.068초

The Measurements of Plasma Cytokines in Radiation-induced Pneumonitis in Lung Cancer Patients (폐암환자에서 방사선 폐렴 예측을 위한 혈장 Cytokine측정)

  • Hur Won Joo;Youn Seon Min;Lee Hyung Sik;Yang Kwang Mo;Sin Geun Ho;Son Choon Hee;Han Jin Yeong;Lee Ki Nam;Jeong Min Ho
    • Radiation Oncology Journal
    • /
    • 제18권4호
    • /
    • pp.314-320
    • /
    • 2000
  • Purpose :To investigate whether changes in plasma concentrations of transforming growth factor-$\beta$1(TGF-$\beta$1), tumor necrosis factor-alpha (TNF-$\alpha$) and interleukin-6 (IL-6) could be used to identify the development of radiation-induced pneumonitis in the lung cancer patients. Methods and Materials :Seventeen patients with lung cancer (11 NSCLC, 6 SCLC) were enrolled in a prospective study designed to evaluate clinical and molecular biologic correlation of radiation-induced pneumonitis. The study began in May 1998 and completed in July 1999. All patients were treated with radiotherapy with curative intent : 1.8 Gy per day, 5 fractions per week. Serial measurements of plasma TGF-$\beta$1, TNF-$\alpha$ and IL-6 were obtained in all patients before, weekly during radiotherapy and at each follow-up visits after completion of treatment. These measurements were quantified using enzyme linked immunosorbent assay (ELISA). All patients were evaluated for signs and symptoms of pneumonitis at each follow-up visit after completion of radiotherapy. High resolution CT (HRCT) scans were obtained when signs and symptoms of pneumonitis were developed after completion of radiotherapy. Results : Thirteen patients eventually developed signs and symptoms of clinical pneumonitis 씬file four patients did not. TGF-$\beta$ 1 levels were elevated in all 13 patients with pneumonitis, which showed characteristic pattern of elevation (38.45 ng/ml at pretreatment, 13.66 ng/ml during radiotherapy, then 60.63 ng/ml at 2-4 weeks after completion of radiotherapy). The levels of TNF- $\alpha$ and IL-6 were also elevated In the group of patients who developed pneumonitis but the pattern was not characteristic. Conclusions : Changes in plasma TGF$\beta$-1 levels before, during and after radiotherapy appears to be a useful means by which to identify patients at risk for the development of symptomatic pneumonitis. Other cytokines like TNF- $\alpha$ and IL-6 shows no meaningful changes in association with radiation pneumonitis.

  • PDF

Inductively Coupled Plasma discharge characteristic of Ne, Ar, Kr mixed gas (Ne, Ar, Kr 혼합가스에서의 유도결합형 플라즈마 방전특성)

  • Her, In-Sung;Choi, Yong-Sung;Lee, Chong-Chan;Jeong, Young-Il;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.9-12
    • /
    • 2004
  • Recently, the environmental problem has received considerable attention. so, many lamps have been developing for environmental requirement and energy efficiency. also, at glow discharge lamp researchers try to reduce energy spending that is power saving lamp. this kind requirement agree with strong points of electrodeless fluorescent lamp has received to now lighting sauce. At low pressure as mTorr I.C.P make high density plasma easily, is good to maintain discharge, has high ionization and does not have failing lighting and losing ability of electron radiation by oxidation and volatilization of electrodes, because this tape does not have electrodes This point of I.C.P can use at electrodeless fluorescent lamp in this study ICP display elements and Ar, Ne, Kr are researched for optical characteristic. each gas is looked into optical characteristic, also mixed gases is experiment for optical characteristic.

  • PDF

A Study of Characteristic of Oriental Herbal Medicine Storage System using Ozone Lamp (오존램프를 이용한 한약재 저장 장치의 특성 연구)

  • Woo, Sung-Hun;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제21권1호
    • /
    • pp.98-103
    • /
    • 2007
  • We made a oriental herbal medicine storage system and studied a preservation characteristic of oriental herbal medicine in this research. The lamp(OZ-Lamp) in a storage system is the low pressure ultraviolet lamp which radiates the sterilizing and ozonic rays. We made research ozone generation and electric discharge characteristic of a oriental herbal medicine storage system, which have radiation feature of ultraviolet rays of a short wavelength to be happened in the electric discharge. Also, we made research an ingredient and quality characteristic of oriental herbal medicine according to ozone treatment storage.

A Study on the Antenna Characteristic Variation according to Ground Plane Size of Print Type Antenna (프린트형 안테나의 접지면 크기에 따른 안테나 특성 변화에 관한 연구)

  • 송면규;양규식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제4권2호
    • /
    • pp.365-370
    • /
    • 2000
  • In this dissertation, in order to analyze the ground plane size which will affect the antenna characteristic, the appropriate antenna was designed and produced in compliance with the needs that the existing antenna should be improved, and then the optimum ground plane size was calculated. It was proved it affected the radiation characteristic greatly but didn't affect the impedance characteristic nearly when ground plane size of the existing folded slot antenna was enlarged with using the copper e cut in some size. Though it require the complicate procedure by the strict design in order to calculate exactly, if it is made of the antenna of the appropriate size that the effect of ground plane can be taken no account, it can be made easily.

  • PDF

The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 반도체 검출기 설계에 관한 연구)

  • Kim, Kyo-Tae;Kim, Joo-Hee;Han, Moo-Jae;Heo, Ye-Ji;Ahn, Ki-Jung;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • 제11권3호
    • /
    • pp.171-175
    • /
    • 2017
  • In the non-destructive inspection field, we invest a lot of time and resources in developing the radiation source system to ensure the safety of the workers. However, the probability of accidents is still high. In order to prevent potential radiation accidents in advance, it is necessary to directly verify the position of the radiation source, but the research is still insufficient. In this study, we developed a monitoring system that can detect the position of the radiation source in the source guide tube in the gamma-ray irradiator. The characteristics of the radiation detector are estimated by monte carlo simulation. As a result, the radiation detector for Ir-192 gamma-ray energy was analyzed to have secondary electron equilibrium at $150{\mu}m$ regardless of the semiconductor material. Also, it is expected that the gamma ray response characteristic is the best in $HgI_2$. These results are expected to be used as a basis for determining the optimal thickness of the radiation detector located in the detection part of the future monitoring system. In addition, when developing a monitoring system based on this, radiation workers can easily recognize the danger and secure safety, as well as prevent and preemptively respond to potential radiation accidents.

Compact Band-notched UWB Antenna Design Based On Transmission Line Model

  • Zhu, Xiaoming;Yang, Xiaodong;Chen, Peng
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.338-343
    • /
    • 2015
  • In order to avoid the interference from existing narrowband communication systems, this paper proposes a compact band-notched UWB (ultra wideband) antenna with size of $12mm{\times}22mm{\times}1.6mm$. Transmission line model is applied to analyzing wide impedance matching characteristic of the modified base antenna, which has a gradual stepped impedance feeder structure. The proposed antenna realizes dual band-notched function by combining two biased T-shaped parasitic elements on the rear side with a window aperture on the radiation patch. The simulation current distributions of the antenna reflect resonant suppression validity of the two methods. In addition, the measured radiation characteristics demonstrate the proposed antenna prevents signal interference from WLAN (5.15-5.825GHz) and WiMAX (3.4-3.69GHz) effectively, and the measured patterns show the antenna omnidirectional radiation in working frequencies.

Design of Data Transmission Corrugated Horn Antenna for RF Sensor Satellite System (RF센서 위성시스템용 데이터 전송 컬러게이트 혼 안테나 설계)

  • Jeon, Jung-Ik;Choi, Hak-Keun;Lim, Seong-Bin;Jang, Jae-Woong;Kim, Tae-Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제11권3호
    • /
    • pp.1-8
    • /
    • 2011
  • In this paper, data transmission corrugated horn antenna for RF sensor satellite system and its radiation characteristic are presented. The proposed antenna is designed, fabricated and measured to obtain the maximum gain at ${\pm}60^{\circ}$ of its radiation patterns. The result of the proposed antenna is that the return loss is less than -15 dB and the gain is over 5 dBi at ${\pm}60^{\circ}$ of its radiation patterns. From these results, it is confirmed that the proposed can be used as data transmission corrugated horn antenna for RF sensor satellite system.

Compact Circularly Polarized Composite Cavity-Backed Crossed Dipole for GPS Applications

  • Ta, Son Xuat;Han, Jae Jin;Park, Ikmo
    • Journal of electromagnetic engineering and science
    • /
    • 제13권1호
    • /
    • pp.44-50
    • /
    • 2013
  • In this paper, we present a circularly polarized (CP) composite cavity-backed crossed dipole antenna for global positioning system (GPS) applications. We produce the CP radiation by crossing two dipoles through a $90^{\circ}$ phase delay line of a vacant-quarter printed ring, which also has a broadband impedance matching characteristic. Two techniques, insertion of meander lines in the dipole arm and arrowhead-shaped trace at its end, are employed to reduce the sizes of the primary radiation element. The compact radiator is backed by a cavity reflector to achieve a wide CP radiation beamwidth. The proposed antenna exhibits a measured bandwidth of 1.450~1.656 GHz for a voltage standing wave ratio (VSWR) < 2 and 1.555~1.605 GHz for AR < 3-dB. At 1.575 GHz, the antenna has a gain of 7 dBic, a frontto-back ratio of 27 dB, AR of 1.18 dB, and 3-dB AR beamwidths of $130^{\circ}$ and $132^{\circ}$ in the x-z and y-z planes, respectively.

Radiation Characteristics of Log Periodic Cantor Koch Dipole Antennas (대수 주기 칸토어 코흐 다이폴 안테나의 복사 특성)

  • Park, Jae-Sung;Choi, Hak-Keun;Park, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제21권9호
    • /
    • pp.1005-1012
    • /
    • 2010
  • In this paper, a novel log periodic cantor koch dipole antenna(LPCKDA), which is composed of the cantor Koch dipole elements instead of the Koch dipole elements, is proposed to reduce the size of the log periodic koch dipole antenna(LPKDA). To investigate the reliability of the proposed antenna, the LPCKDA is designed and analyzed at 0.5~1.5 GHz and compared with the LPKDA(Log Periodic Koch Dipole Antenna) characteristic. It is shown that although the proposed LPCKDA has a decreases of 5 % in the length of the dipole elements, radiation characteristics of LPCKDA are similar to radiation characteristics of the LPKDA.

A Combustion Characteristic Analysis of PMMA by Cone Heater of the flexible Heat Flux (콘 히터의 유동적인 열선속을 적용한 PMMA의 연소 특성 분석)

  • Moon, Sung-Woong;Ryu, Sang-Hoon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • 제24권3호
    • /
    • pp.39-44
    • /
    • 2010
  • The cone calorimeter method which is currently used to measure the heat release rate has a fixed rate of radiation. However, in the real fire, when flame combustible material burns, it releases the identical heat flux. We measured the changes of temperature of a fire using FDS in order to analyze flexible heat flux of combustion characteristics. In this study, the rate of radiation of cone calorimeter was adopted by using FDS. Follow those results, it produce between the rate of radiation in the growth period and decline period have a significant impact on heat release rate of PMMA.