• 제목/요약/키워드: Characteristic line

검색결과 1,633건 처리시간 0.027초

불평형 고장시의 초전도 케이블의 응동 특성 (Dynamic Characteristic of the Superconducting Cable in unbalanced Faults)

  • 이근준;이종배;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.37-39
    • /
    • 2007
  • In the faults of power line, single line ground and line-to-line fault make power system to unbalanced. These fault currents make unbalanced power system. This paper suggests the simulation results of dynamic characteristic of HTS cable system under unbalanced faults condition using EMTDC, Quench phenomenon and current limiting effects are observed. However, quench on the HTS is destroy cable system, coordination with SFCL has to be considered.

  • PDF

전송선형 초광대역 FM변별기에서 결합 저항기의 오차가 미치는 영향 (Effects of Coupling Resistor Resistance Discrepancy from Characteristic Impedance on Discriminating Characteristics of Super Wide-Band FM Line Discriminator)

  • 이충웅
    • 대한전자공학회논문지
    • /
    • 제7권4호
    • /
    • pp.1-5
    • /
    • 1970
  • 본 논문에서는 전차선형초광대역 FM 변별기의 결합저항식(변별기에 사용된 전송선의 특성임피단스)와의 오차가 ±10%이내일 때 전송선형 FM 변별기의 입력임피단스와 출력파형의 디스토숀에 미치는 영향을 고찰했다.

  • PDF

GaAs MMIC상에서 주기적으로 천공된 홀을 가지는 접지 금속막 구조를 이용한 전송선로 특성연구 및 코프레너 선로를 이용한 온칩 초소형 임피던스 변환기에의 응용 (A Study on Characteristics of the Transmission Line Employing Periodically Perforated Ground Metal on GaAs MMIC and Its Application to Highly Miniaturized On-chip Impedance Transformer Employing Coplanar Waveguide)

  • 윤영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1248-1256
    • /
    • 2008
  • In this paper, basic characteristics of transmission line employing PPGM (periodically perforated ground metal) were investigated using theoretical and experimental analysis.According to the results, unlike the conventional PBG (photonic band gap) structures, the characteristic impedance of the transmission line employing PPGM structure showed a real value, which exhibited a very small dependency on frequency. The transmission line employing PPGM structure showed a loss (per quarter wave length) higher by $0.1{\sim}0.2\;dB$ than the conventional microstrip line. According to the investigation of the dependency of RF characteristic on ground condition, the RF characteristic of the transmission line employing PPGM structure was hardly affected by the ground condition in the frequency lower than Ku band, but fairly affected in the frequency higher than Ku band, which indicated that coplanar waveguide employing PPGM structure was optimal for RF characteristic and reduction of size. Considering above results, impedance transformer was developed using coplanar waveguide with PPGM structure for the first time, and good RF characteristics were observed from the impedance transformer. In case that {\lambda}/4$ impedance transformer with a center frequency of 9 GHz was fabricated for a impedance transformation from 20 to10 {\Omega}$, the line width and length were 20 and $500\;{\mu}m$, respectively, and its size was only 0.64 % of the impedance transformer fabricated with conventional microstrip lines. Above results indicate that the transmission line employing PPGM is a promising candidate for a development of matching and passive elements on MMIC.

광대역 동축선로 임피던스 변환회로의 동작 특성 분석 (The analysis of the operating characteristic for the wideband coaxial line impedance transformer)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제23권2호
    • /
    • pp.165-172
    • /
    • 2019
  • 두 개 이상의 동축선을 사용하여 한 쪽은 동축선을 직렬로 연결하고, 반대 쪽은 동축선을 병렬로 연결하면 광대역에서 동작하는 임피던스 변환회로가 된다. 동축선을 이용한 광대역 임피던스 변환회로는 동축선의 외곽 도체를 임피던스 변환에 이용하기 때문에 수식 또는 시뮬레이션 프로그램을 통한 예측이 매우 어렵다. 본 논문에서는 ${\lambda}/4$-마이크로스트립 선로 임피던스 변환회로의 선로 신호 감쇄에 대한 전달 특성(S21) 해석을 바탕으로 $25{\Omega}$ 동축선 두 개를 이용한 광대역 4:1($50{\Omega}:12.5{\Omega}$) 전송선로 임피던스 변환회로를 제작하여 동작 특성을 살펴보았다. 두 개의 동축선을 이용한 광대역 임피던스 변환기는 동축선의 길이를 90도(${\lambda}/4$)로 인식하는 주파수에서 신호 전달 특성(S21)이 급격히 감소하는 노치 특성이 발생하였다. 또한, 동축선 길이의 $0.06{\sim}0.2{\lambda}$에 해당하는 주파수 범위에서 신호 전달특성(S21) -0.2dB 이내의 값을 가졌다. 이러한 신호 전달특성(S21)은 출력 단에 연결된 마이크로스트립 선로의 길이 변화를 통해 약간의 동작 주파수 범위 변화와 원하는 주파수에서 최적의 신호 전달특성(S21)을 설정할 수 있음을 확인하였다.

실리콘에 기초한 새로운 크로스바 구조의 손실있는 대칭 결합선로에 대한 유한차분법을 이용한 해석 (Analysis of Symmetric Coupled Line with New Crossbar Embedded on Si-based Lossy Structure using the FDTD Method)

  • Kim, Yoonsuk
    • 한국군사과학기술학회지
    • /
    • 제4권2호
    • /
    • pp.122-129
    • /
    • 2001
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite- Difference Time-Domain(FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency- dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

  • PDF

X선 CT화상을 이용한 사상체질의 형태학적 특징 파라메타의 제안 (Suggestion of the morphological characteristic parameters according to the Lee's physical constitution theory using X-ray computed tomography)

  • 조봉관;배종일;고병희;제등정남
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.13-16
    • /
    • 1993
  • In this paper the morphological characteristic parameters according to the Lee's physical constitution theory are suggested using the X-ray computed tomography. The Lee's physical constitution theory is classify into 4 physical constitutional types by the relative degree of visceral function: those are macro-negative(strong liver- weak lung), micro-negative(strong kidney- weak spleen), micro-positive(strong spleen- weak kidney) and macro-positive(string lung- weak liver). The morphological characteristic parameters are the following. The AA-line is the distance between Rt. & Lt. acupuncture point keug-cheun. The BB-line is the length of lung. The CC-line is the longest width of thorax. The DD-line is the vertical distance between the CC-line and the EE-line. The EE-line is the distance between the Rt. and Lt. anterior superior iliac spines. As the results macro-negative(strong liver-weak lung) has the longest CC-line and the short BB-line. Micro-negative(strong kidney-weak spleen) has the longest EE-line and the short CC-line. Micro-positive(strong spleen-weak kidney) has the longest DD-line and the short BB-line. And macro-positive(strong lung-weak kidney) has the longest BB-line and the short EE-line.

  • PDF

실험계획법을 이용한 단상 유도형 동기전동기의 최적 설계 (Optimal Design of Single-Phase Line-Start Permanent Magnet Synchronous Motor by using Design of Experiment)

  • 김승주;정대성;이철규;이형우;이주;오세영
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.699-704
    • /
    • 2007
  • In this paper, optimized model was designed for the starting characteristic of the Single-Phase Line-Start Permanent Magnet Synchronous Motor by using the Design of Experiment. A field pole angle, thickness and distance from center axis of permanent magnet were selected as design factor. We executed the transient state characteristic analysis of 8 test models. The transient state characteristic analysis was executed by using the 2 dimensional Finite Element Method and the Time Difference Method. We checked the fact that the selected design factor affected starting characteristic of the Line-Start Permanent Magnet Synchronous Motor. Depend on this result we found the optimized design point by using the response optimization.

Design of an extremely miniaturized branch-line coupler

  • Kang, In Ho;Li, Xi Qiang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권8호
    • /
    • pp.995-999
    • /
    • 2014
  • In this paper, a new size-reduction approach for branch-line coupler is introduced which uses parallel end-shorted coupled lines with lumped capacitors. The characteristic of the new design was analyzed using even-odd mode method, and simulated on HFSS before fabricated on the FR4 epoxy glass cloth copper-clad plat (CCL) PCB substrate at center frequency of 1 GHz. The electrical length of transmission line was reduced to 15 degrees, therefore the size of branch-line coupler was largely reduced approximately maintaining the same characteristic around the stable center frequency. The insertion loss of the branch-line coupler filter was -4.39 dB. The size of the overall hybrid is $20mm{\times}20mm$. Measurements results were well agreed with the simulated ones.

두꺼운 외부도체를 가진 손실이 있는 동축선로의 특성임피던스 근사 (Approximation of the Characteristics Impedance of a Lossy Coaxial Line with a Thick Outer Conductor)

  • 강진섭;김정환
    • 한국전자파학회논문지
    • /
    • 제11권4호
    • /
    • pp.649-656
    • /
    • 2000
  • 본 논문에서는 두꺼운 외부도체를 가진 손실이 있는 동축선로의 해석적인 특성임피선스 표현식 및 근사식을 제안했다. 그리고 제안된 근사식을 동축선로의 동작 주파수대역에서 사용 가능하다는 것을 3.5mm reference air line에 대해 보였다.

  • PDF

Skew를 고려한 유도기동형 영구자석 동기전동기의 특성 해석 (Characteristic Analysis of Line-start Permanent Magnet Synchronous Motor considering Skew Effect)

  • 오영진;이인우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.12-14
    • /
    • 2005
  • This study investigates the characteristic analysis of Line-start Permanent Magnet Synchronous Motor considering skew effect. The effects of the skew on machine characteristic are analyzed by using direct co-simulation of Matlab Simulink and Flux2D. Validity of analysis method is confirmed by the analysis result of Non-skew Model.

  • PDF