• Title/Summary/Keyword: Characteristic line

Search Result 1,631, Processing Time 0.029 seconds

Analysis of Characteristic Frequency along Fault Distance on a Transmission Line (송전 선로의 사고 거리에 따른 특성 주파수 해석)

  • 남순열;홍정기;강상희;박종근
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.8
    • /
    • pp.432-437
    • /
    • 2004
  • Since the characteristic frequency is decreased in proportion to the fault distance, the characteristic frequency component may be insufficiently eliminated by a low-pass filter on a long transmission line. In order to set a standard for the cut-off frequency of the low-pass filter, this paper proposes a method for obtaining the characteristic frequencies due to line faults. The application results of the proposed method are presented for line to ground (LG) faults and line to line (LL) faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault signals under different fault locations and fault inception angles. By comparison between the characteristic frequencies obtained from the proposed method and the EMTP simulation, it is shown that the proposed method accurately obtains the characteristic frequency.

A Method for Calculating the Characteristic Impedance of Substrate Integrated Artificial Dielectric Transmission Lines (기판적층형 가유전체 전송선로의 특성 임피던스 계산 방법)

  • Lim, Jong-Sik;Koo, Ja-Kyung;Han, Sang-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1585-1591
    • /
    • 2009
  • This paper describes a new method for extracting characteristic impedance of transmission line using Substrate Integrated Artificial Dielectric (SIAD). The new procedure to calculate the characteristic impedance of SIAD transmission line is described with the proper equations and basic transmission line theory. The characteristic impedance is determined as an almost fixed value in the proposed method, while it fluctuates according to frequency in the previous method. As the result, the effective dielectric constant of SIAD transmission line is calculated as a fixed value rather than fluctuating one. In order to show the validity of the proposed method, SIAD microstrip lines are simulated and measured, and characteristic impedances and effective dielectric constant are calculated and compared to the previous method.

Measurement method of the signal transfer characteristic(S21) of the impedance transformer (임피던스 변환회로의 신호 전달특성(S21) 측정 방법)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1282-1289
    • /
    • 2019
  • In order to measure the transfer characteristic(S21) of the impedance transformer, two impedance transformers must be symmetrically connected. However, the transfer characteristic of two symmetrically connected impedance transformers is influenced by the length of the intermediate connection line. This paper theoretically examines closely the length of the intermediate connection line to obtain the accurate transfer characteristic of the impedance transformer. The electrical length of the intermediate connection line for obtaining the accurate transfer characteristic of the 4:1(50-Ω:12.5-Ω) impedance transformer is calculated about 45°. Using the calculated length of the connection line, The λ/4-microstrip impedance transformer is fabricated at 1 GHz to measure the transfer characteristic. The symmetrically connected impedance transformer is measured the reflection characteristic(S11) of -40.64dB and the transfer characteristic(S21) of -0.154dB at 0.980GHz. This value is approximately equal to the theoretical calculated 987MHz center frequency and -0.15dB transfer loss value of the λ/4-microstrip impedance transformer.

A Slotted Triangular-Patch Type Artificial Transmission Line (슬롯을 가진 삼각패치형 인공전송선로)

  • Oh, Song-Yi;Choi, Kyung;Hwang, Hee-Yong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.4
    • /
    • pp.164-167
    • /
    • 2010
  • In this paper, an artificial transmission line of triangular-patch type with slots is proposed. This artificial transmission line is useful for miniaturizing the electrical lengths of conventional transmission lines. Also, this structure is easy to regulate the characteristic impedance and electrical lengths. The electrical lengths and the characteristic impedances of the proposed artificial transmission line with some parameters are researched and summarized The proposed artificial transmission line could be useful for compact designs for most of the passive microwave components. The optional-artificial transmission line is fabricated and measured at 2.45GHz.

  • PDF

The Research Study on the Products Purchase Type of On-line Shopping Mall Buyer (온라인 쇼핑몰 구매자의 제품별 구매 유형에 관한 조사연구)

  • Seo, Gab-Sung;Jang, Gi-Young
    • International Commerce and Information Review
    • /
    • v.9 no.4
    • /
    • pp.91-104
    • /
    • 2007
  • The recent stabilization of the Internet is now driving every aspect of life into an Internet presence. In the coming years, the Internet will see growth in numbers unlike the world has ever seen. The subject of this study is the Research Study on the Products Purchase Type of On-line Shopping Mall Buyer. Also, this paper is to examine the relations between customer satisfaction and intensity of repurchase intention and complaining behavior in on-line context. On-line shopping customer depths interview it led and the online afternotes trust evaluation dimension was discovered the of useful characteristic, intention characteristic, exaggerating characteristic and on-line afternotes with or without. From these results, this paper suggests effective marketing strategy to the marketer who plans to run on-line shopping mall in the near future and also to the marketer who plans to sell products through the on-line shopping mall.

  • PDF

Design and Implementation of a directional coupler with high directivity using Branch Line Structure (Branch-Line 구조를 이용한 높은 방향성을 가지는 결합기 설계 및 제작)

  • 심부석;이승철;한대현;안점영
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.350-353
    • /
    • 2003
  • In this paper, we designed and implemented a 10dB directional coupler with high directivity using branch line structure. The characteristic impedance of parallel branch line for 10 dB directional coupler is about 150 $\Omega$. To realize high characteristic impedance in microstrip line, we used the coupled line structure. The directional coupler were implemental and measured. The measured results show that the directivity is high than 24 dB.

  • PDF

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

Dynamic Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor by Parameter Variation (단상 유도형 동기전동기의 파라미터 변화에 따른 동특성 해석)

  • Oh, Se-Young;Jung, Dae-Sung;Lim, Seung-Bin;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.763-764
    • /
    • 2006
  • In this paper, optimized model was designed for the starting characteristic of the Single-Phase Line-Start Permanent Magnet Synchronous Motor by using the Design of Experiment. A field pole angle, thickness and distance from center axis of permanent magnet were selected as design factor. We executed the transient state characteristic analysis of 8 test models. The transient state characteristic analysis was executed by using the 2 dimensional Finite Element Method and the Time Difference Method. We checked the fact that the selected design factor affected starting characteristic of the Line-Start Permanent Magnet Synchronous Motor. Depend on this result we found the optimized design point by using the response optimization.

  • PDF

Characteristic Analysis of Gapped Surge Arresters for D.C. Railway Line (직류 전차선로용 공극형 피뢰기의 특성 분석)

  • 조한구;한세원;윤한수;천종욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.485-488
    • /
    • 2001
  • This paper provides the result of analysis of the structure and I-V characteristics of D.C. 1500 V surge arresters which were installed in railway line currently. As Porcelain housed surge arresters have unstable elements such as exploding and dispersion, so it is thought that the system is protected more stably with replacement of polymer housing. The adoption of gap mitigates the voltage stress which is degradation factor of surge arresters and the research is needed to enhance the life characteristic in additive and manufacturing process. Therefore, it is thought that the research should be continued to develop homemade the surge arresters for D.C. railway line as well as transmission line.

  • PDF

mechanism of Equivalent Power Distribution in Parallel Connected ICP for Large Area Processing

  • Lee, Jin-Won;Bae, In-Sik;An, Sang-Hyeok;Jang, Hong-Yeong;Yu, Sin-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.510-510
    • /
    • 2012
  • 반도체, 디스플레이, 태양광 등의 공정에서 사용되는 웨이퍼의 크기가 증가하고, 생산률이 플라즈마의 밀도에 비례한다는 연구 결과가 발표되면서 대면적 고밀도 플라즈마 소스 개발에 대한 연구가 활발히 진행되고 있다. 특히, ECR, ICP, Helicon plasma 등 고밀도 플라즈마 소스에 대한 관심이 높아지고 있다. 이에 따라, 여러 개의 ICP를 결합한 multiple ICP를 이용해 대면적 고밀도 플라즈마 소스 개발을 진행했다. Multiple ICP의 경우 각 ICP 소스에 같은 power (current)를 공급해야만 균일한 플라즈마 방전이 발생되어 균일도를 확보 할 수 있다. Current controller 같은 추가적인 장비를 설치하지 않고, power를 분배하는 transmission line을 coaxial 형태로 설계하고 같은 길이로 병렬 연결함으로써 각각의 ICP소스에서 균일한 플라즈마를 방전시킬 수 있었다. Power generator에서 보는 각 ICP의 total impedance는 각 ICP 소스의 impedance와 coaxial 형태의 transmission line의 characteristic impedance, frequency, 길이의 함수로 구할 수 있고, 이 total impedance가 일정하기 때문에 current가 균등하게 분배되어 각 ICP소스에 균등한 power 분배가 가능한 것이다. 실질적으로 ICP 소스의 impedance는 플라즈마 방전 유무에 따라 변화하기 때문에 일정하게 유지하는 것은 어렵다. Transmission line의 characteristic을 사용함으로써 ICP의 impedance의 변화에 상관없이 Total impedance를 일정하게 유지시킴으로써 균등한 power 분배가 가능하다는 것을 연구했다. Frequency는 13,56MHz, characteristic impedance를 $50{\Omega}$ (coaxial cable)으로 고정하고, ICP 소스의 플라즈마 방전 유무/antenna turn/소스 위치에 따른 total impedance를 transmission line의 길이에 따라 측정하고, 이를 이론값, 그래프와 비교하였다. 특정 length에서 플라즈마 방전 유무(ICP의 impedance 변화)와 상관없이 비교적 일정한 total impedance를 유지하는 것을 확인 했다. 이것은 특정 길이를 갖는 coaxial형태의 transmission line를 연결하면, total impedance는 플라즈마 방전 유무로 발생하는 ICP의 impedance 변화와 상관없이 일정하게 유지되어 각 ICP소스에 균등한 파워 분배가 가능하다는 것을 보여준 결과이다. 이것을 토대로 frequency에 따라(또는 characteristic impedance에 따라) 균등한 파워 분배가 가능한 coaxial 형태 transmission line의 특정 길이를 구할 수 있고, 대면적 소스에서 균등한 파워 분배를 위한 병렬연결에 적용할 수 있을 것이다.

  • PDF