An Experimental Study on the Absorption Performance of Steel-Wire Sound Absorbing Materials (금속와이어 흡음재의 흡음성능에 관한 실험적 연구)

  • 서성원;용호택;이동훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.413-421
    • /
    • 2003
  • The acoustic performances of steel-wire sound absorbing materials with different thicknesses and bulk densities were investigated experimentally. The well-known two-cavity method was used to measure the characteristic impedance, propagation constant and absorption coefficient. The normal absorption coefficients measured by two-cavity method agreed well with those by the two-microphone impedance tube method. The experimental results showed that the magnitude of the absorption coefficient and the frequency range of the maximum absorption coefficient were controllable by changing the thickness and bulk density of the steel-wire. Therefore, the steel-wires obtained from the crushed tire chips could be used as a good absorbing material.

Wideband Power Divider Using a Coaxial Cable (동축선을 이용한 광대역 전력 분배기)

  • Park, Ung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.661-668
    • /
    • 2012
  • A coaxial-cable impedance transformer that can be used in high power and wideband frequency range is an arbitrary impedance transformation ratio by an additional coaxial cable. The coaxial-cable impedance transformer to be 50-${\Omega}$ to 25-${\Omega}$ impedance transformation ratio is easily operated an wideband power divider by connecting two 50-${\Omega}$ lines at 25-${\Omega}$ impedance point. This wideband power divider has a poor output matching characteristic and a poor isolation characteristic between two output ports. In this paper, it proposes a coaxial-cable power divider to be a good output matching and isolation characteristics as it uses the singly terminated filter design theory. The odd-mode operation characteristic of the suggested power divider to use singly terminated low pass filter coefficient due to matching order and ripple value is examined by ADS program. And, it fabricates and measures the operation characteristic of 2-way power divider with 2nd-order and 4th-order matching circuit.

Design of Broad Band Piezoelectric Transducer Using Matching Layers (정합층을 이용한 광대역 압전 진동체 설계)

  • 조치영;서희선
    • Journal of KSNVE
    • /
    • v.6 no.6
    • /
    • pp.749-754
    • /
    • 1996
  • In this paper, a design method of matching layers is presented for the sandwich type broad band underwater acoustic vibrators. The characteristic impedances of matching layers are determined to be matched to the characteristic impedance of head mass material. For the dynamic characteristic analysis of the sandwich type transducers, one dimensional FEM technique is also introduced. A test vibrator with the quarter wave matching layers has been designed to verify the proposed method. And the wide band characteristics of the input impedance and transmitting voltage response (TVR) are investigated.

  • PDF

Analysis for the conventional impedance of counterpoise using EMTP (EMTP를 이용한 매설지선의 규약접지임피던스 해석)

  • Kim, Jong-Ho;Joe, Jeong-Hyeon;Beak, Young-Hwan;Lee, Gang-Su;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.47-50
    • /
    • 2009
  • When the lightning currents flow through the ground electrode, the grounding system should be evaluated by the grounding impedance rather than the ground resistance because a grounding system shows the transient impedance characteristic by the inductance of the ground electrode and the capacitance of the soil. The ratio of the peak values of electric potential and currents is the conventional impedance that shows the transient characteristic about impulse currents of the grounding system in a roundabout way. The grounding system having low conventional impedance is a fine grounding system with low electric potential when the lightning currents flow. In this paper the conventional impedance of the counterpoise is calculated by using the distributed parameter circuit model and embodied the distributed parameter circuit model by using the EMTP program The adequacy of the distributed parameter model is examined by comparing the simulated and the measured results. The conventional impedance of the counterpoise is analyzed for first short stroke and subsequent short stroke currents.

  • PDF

an Analysis of the Variation on the Impedance Characteristic according to Effective Area of Globe Control Valve at Low Frequency Perturbation (저주파 압력섭동에서 글로브 제어밸브의 유효 단면적에 따른 임피던스 특성 변화 해석)

  • Park, Seungsoo;Yoon, Woongsup;ohm, Wonsuk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.718-723
    • /
    • 2017
  • In this paper, Analytical study is carried out on the impedance characteristics of the globe control valve, which is mainly used for thrust control in liquid rockets, according to the effective area at low frequency perturbation. The impedance tends to increase according to effective area and the cause of impedance characteristic change through flow field visualization is investigated. In the future, the information on the change in the impedance characteristics of the control valve can be used to obtain the impedance of the supply system and it can be utilized to predict pogo phenomenon as well as design accumulator and orifice to reduce the pogo phenomenon.

  • PDF

Wideband Impedance Transformer Using a Coaxial Cable (동축선을 이용한 광대역 임피던스 트랜스포머)

  • Park, Ung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.789-794
    • /
    • 2011
  • A coaxial-cable impedance transformer used in wideband frequency range is generally restricted to the fixed impedance transformation ratio as n2:1 or 1:n2(n: the number of coaxial cables). In this paper, we propose a new coaxial-cable impedance transformer to have an arbitrary impedance transformation ratio. We have fabricated three impedance transformers($50-{\Omega}$ to $25-{\Omega}$, $50-{\Omega}$ to $20-{\Omega}$ and $50-{\Omega}$ to $9-{\Omega}$) to confirm the operation characteristic of the suggested impedance transformer. The reflection characteristics (S11) of the fabricated $50-{\Omega}$ to $25-{\Omega}$ and $50-{\Omega}$ to $20-{\Omega}$ impedance transformer were less than -15dB over about 3-octaves frequency range and the reflection characteristic (S11) of the fabricated $50-{\Omega}$ to $9-{\Omega}$ impedance transformer was less than -15dB over about 1-octave frequency range, respectively.

A Study on the Transient Ground Impedance Modeling for Rod-type Grounding Electrodes by Frequency and Time Domain Characteristic Tests (주파수 및 시간영역 특성시험에 의한 봉형 접지전극의 과도 접지임피던스 모델링에 관한 연구)

  • Kim, Jong-Uk;Kim, Kyung-Chul;Shin, Pan-Seok;Choi, Jong-Ki;Choi, Sun-Kyu;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.133-141
    • /
    • 2010
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. Copper and concrete rod electrodes are the most commonly used grounding electrode in electric distribution systems. In this paper, the ground impedance of copper and concrete rods has been measured by frequency and time domain characteristic tests. An equivalent transfer function model of the ground impedance is identified from the measured values by using ARMA method and evaluated by comparing conventional grounding impedances.

Design of Microwave Unequal Power Dividers Using Defected Ground Structure (결함접지구조를 이용한 초고주파 비대칭 전력 분배기 설계)

  • Lim, Jong-Sik;Koo, Jae-Jin;Oh, Seong-Min;Ahn, Dal;Choi, Kwan-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1099-1104
    • /
    • 2007
  • A 1:6 Unequal 2-way Wilkinson power divider is proposed. The required microstrip line with $207{\Omega}$ characteristic impedance for 1:6 power divider is realized by adding defected ground structure (DGS) to the standard microstrip line. The adopted DGS has the rectangular geometry which results in the increased characteristic impedance. The rectangular-shaped DGS produces the transmission line having much higher characteristic impedance due to the increased equivalent inductance. The measured performances of the fabricated 1:6 power divider show the expected S-parameters with a good agreement with the predicted ones.

Theoretical Characteristics of the Probe with Respect to the Engine Oil States (엔진오일 상태에 대한 프로브의 이론 특성)

  • Kim, Young-Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.22-24
    • /
    • 2012
  • Depending on the status of the engine oil, the dielectric constant is changed. Dielectric constant of oil is related to the characteristic impedance of the probe and the characteristic impedance of the probe determines the reflected signal. In this paper, we derive an equivalent circuit of the probe and using the dielectric constant obtained by measuring the capacitance, the theoretical reflection coefficient of the probe was calculated. In the results, if the engine oil is deteriorated, we can see that the reflection coefficient is increased.

Study of supersonic flame acceleration within AN-based high explosive containing various gap materials (AN계열 화약의 다양한 Gap 실험을 통한 초음속 화염 전파 특성 연구)

  • Lee, Jin-Wook;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.342-349
    • /
    • 2012
  • We study the gap effect on detonating high explosives using the characteristic acoustic impedance theory and numerical simulation. A block of charge embedded with multiple gap inserts is detonated at one end to understand the ensuing flame propagation through multiple gap materials. The present high-order multimaterial simulation provides meaningful validation of complex interface tracking algorithm as it is implemented in the SNU-Hydropack code.

  • PDF