• 제목/요약/키워드: Characteristic Wave

검색결과 801건 처리시간 0.028초

Far infrared를 이용한 생체정보 인터페이싱에 대한 연구 (Research of human body information interfacing with Far infrared and application to physical therapy)

  • 박래준;김재윤
    • The Journal of Korean Physical Therapy
    • /
    • 제13권3호
    • /
    • pp.509-527
    • /
    • 2001
  • The Sun's ray is composed of Infrared(49%), Visible light(40%) and Ultra violet(11%), however the ray getting to the earth is FIR(Far infrared; 60%), IR(Infrared; 20%), and UV(Ultra Violet; 20%). Human beings has utilized FIR already from time immemorial. Hershel found out Infrared for the first time. in the Industrial Revolution the Infrared and FIR had been begun to use making products. In these days, with contemporary science FIR would be begun to clear up the implication in the human body and organic compound. IR classified by wavelength three parts NlR, MIR, FIR. There is FIR which is radiated from healthy human body the wave length is 8-l4m. The human body is composed of proteins which get easily changed by a thermal factor (about 42 $^{\circ}$C over). FIR with low temperature can deeply penetrate on the human body composed things without troublesomes, since FIR has effectively operated on the human body at low temperature (35-40 $^{\circ}$C). When FlR penetrated on the human body. it would inhibit the abnormal genes and cells expression, and then information of DNA and RNA would be reexpressed for arranging DNA and RNA abnormal state. As FlR's receptors in the body, it could be presumed that N-glycosyl linkage of purine and deoxyribose, RNA splicing process, and Heat shock protein. To take the FIR which was a optimized wavewlength and strength, at first, we induced the characteristic algorithm and the computerized programing. Then we formed that the formular of optimized FIR with physical, mathematical logic and theory. especially, Plank, Kirchhoff, Wien, Stefan-Boltzmann's logic and law. In the long run, the formular was induced with integration mathematical, since we had to know the molecular wavelength. Based on the induced formular as above, we programmed the optimized FlR radiating computerized program. In this research, we designed the eletronic circuit f3r interfacing with human body to diagnosis and treatment with FIR sensor which radiated FIR wavelength optimized.

  • PDF

프레스 금형 마모에 대한 음-초음파 신호 특성 분석 (Characterization of Acousto-ultrasonic Signals for Stamping Tool Wear)

  • 김용연
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.386-392
    • /
    • 2009
  • This paper reports on the research which investigates acoustic signals acquired in progressive compressing, hole blanking, shearing and burr compacting process. The work piece is the head pin of the electric connector, whose raw material is the preformed steel bar. An acoustic sensor was set on the bed of hydraulic press. Because the acquired signals include the dynamic characteristics generated for all the processes, it is required to investigate signal characteristics corresponding to unit process. The corresponding dynamic characteristics to the respective process were first studied by analyzing the signals respectively acquired from compressing, blanking and compacting process. The combined signals were then periodically analyzed from the grinding to the grinding in the sound frequency domain and in the ultrasonic wave. The frequency of around 9 kHz in the sound frequency domain was much correlated to the tool wear. The characteristic frequency in the acoustic emission domain between 100 kHz and 500 kHz was not only clearly observed right after tool grinding but its amplitude was also related to the wear. The frequency amplitudes of 160 kHz and 320 kHz were big enough to be classified by the noise. The noise amplitudes are getting bigger, and their energy was much bigger as coming to the next regrinding. The signal analysis was based on the real time data and its frequency spectrum by Fourier Transform. As a result, the acousto-ultrasonic signals were much related to the tool wear progression.

OSSB 변조의 비선형성을 고려한 OFDM MMoF 시스템의 성능 (Performance of OFDM MMoF System considering Nonlinearity of OSSB Modulation)

  • 김창중;이호경
    • 대한전자공학회논문지TC
    • /
    • 제43권3호
    • /
    • pp.27-31
    • /
    • 2006
  • Millimeter over Fiber (MMoF) 기법은 저손실로 장거리에 신호를 전송하기 위하여 밀리미터 대역의 신호를 광학적으로 변조하여 광섬유에 실어서 전송하는 기법이다. 이때 광학적 변조 기법으로는 색 분산(chromatic dispersion)이 적고 대역폭 효율이 뛰어난 광학적 단측파대 변조 (Optical Single sideband; OSSB) 방식이 주로 사용된다. OSSB를 사용하는 MMoF 시스템의 광학 연결부는 비선형 증폭기로 취급될 수 있으며, 그것의 AM/AM 특성 함수는 제 1차 제 1종 베셀 함수이다. 본 논문에서는 이를 고려한 OFDM MMoF 시스템의 성능을 알아보았다. 우리는 OFDM MMoF 시스템의 비선형 왜곡 잡음 전력을 추정하여 이론적인 비트 오율(Bit Error Rate; BER)을 분석하였으며, 모의실험을 통해 이를 검증하였다.

Pink Noise가 개인별 특성에 따라 뇌파 집중지표에 미치는 영향과 다중지능과의 관계 (Relationship Between Effects of Pink Noise on Brain Wave Concentration Index by Individual Characteristics and Multiple Intelligence)

  • 신성권;심준영
    • 감성과학
    • /
    • 제16권4호
    • /
    • pp.481-492
    • /
    • 2013
  • 이 연구는 성인 남녀 462명을 대상으로 사전 설문검사를 통해 성별, 손잡이, 혈액형, 연령 등의 개인별 특성 집단과 다중지능 유형별 점수를 분류하였다. 그런 다음 뇌파측정시스템을 이용하여 전전두엽 부위인 Fp1과 Fp2 부위에 측정 전극을 부착하고 무자극 상태와 순수한 Pink noise 청각자극 상태에서의 집중력의 변화와 다중지능과의 관계를 알아보고자 하였다. 공분산분석 결과, 무자극에 비해 Pink noise 자극 시 대상자 전체의 평균 집중력이 유의하게 높게 나타났다. 개인별 특성에서는 남녀 성별을 제외한 왼손잡이, A형, 30대 집단에서 집중력이 유의하게 높게 나타났다. 그리고 무자극에 비해 Pink noise 상태의 집중력은 공간적 지능과의 관계가 더욱 강화되었고, 음악적 지능과는 음적 상관관계를 형성하였다. 이러한 결과는 집중력 향상을 위한 Pink noise 활용 시 개인별 특성을 반영해야할 필요성이 있음을 시사하였다.

Infrared 광학초자의 초정밀 가공 특성 (The Characteristics on Ultra Precision Machining for Infrared Optical Materials)

  • 양순철;허명상;김상혁;이길재;이상용;국명호;장기수;유선영;원종호;김건희
    • 한국정밀공학회지
    • /
    • 제29권3호
    • /
    • pp.253-260
    • /
    • 2012
  • In nowadays, the infrared optics is frequently employed to various fields such as military, aerospace, industry and medical. To develop the infrared optics, special glasses which can transmit infrared wave are required. Ge(Germanium), Si(silicon), and fluoride glasses are typically used for material of the infrared optics. Compared with Ge and Si glasses, fluoride glasses have high transmittance in infrared wavelength range. Additionally, UV(ultraviolet) and visible light can be transmitted through fluoride glasses. There characteristics of fluoride glasses makes it possible to evaluate optical performance with generally used visible testing equipment. In this paper, we used design of experiment to find ultra precision machining characteristic of Ge and fluoride glasses and optimized machining process to obtain required form accuracy of PV(Peak to Valley) $0.2\;{\mu}m$.

일방성(一方性) 복함재료(複合材料)의 파괴거동(破壞擧動) 및 강도평가(强度評價)에 관(關)한 연구(硏究) (A Study on the Strength Evaluation of Unidirectional Carbon Fiber Reinforced Plastics by Nondestructive Method)

  • 장홍근;이주석;조경식;이승희;박은수
    • 비파괴검사학회지
    • /
    • 제7권2호
    • /
    • pp.42-47
    • /
    • 1988
  • 이상의 결과를 요약하면 다음과 같다. 1) 초음파 C-scan 법에 의하여 층간분리, 기지균열 등의 손상 정도, 크기 및 형태의 판별이 가능하며 충격손상은 주로 섬유의 주축방향으로 성장한다. 2) 복합재료의 인장파괴시 적층구조에 따라 상이한 AE 양상을 나타내며 이 원인은 파괴 mode의 차이에 기인한다. 3) 섬유의 파단은 기지파단의 경우 보다 강력한 AE activity를 나타내며 peak amplitude의 분포를 분석하여 파괴 mode의 해석이 가능하다. 4) 복합재료의 파괴강도는 적층구조, 충격 손상 등에 영향을 받으며 응력파 계수(SWF)의 측정에 의해 정성적 평가가 가능하다.

  • PDF

펄스 레이저와 CFPI를 이용한 이종금속 접촉부의 이물질 측정에 관한 연구 (A Study on the Measurement of Foreign Material in Dissimilar Metal Contact Using Pulse Laser and Confocal Fabry-Perot Interferometer)

  • 홍경민;강영준;박락규
    • 비파괴검사학회지
    • /
    • 제33권2호
    • /
    • pp.160-164
    • /
    • 2013
  • 레이저 초음파검사 장치는 레이저 빔을 이용하여 초음파 신호를 발생시키고 측정하는 비접촉식 결함 검사 장치이다. 이 장치는 펄스 레이저 빔을 이용하여 광대역 주파수 범위를 갖는 초음파 신호를 발생시키고 작은 점으로 집속된 레이저 빔을 이용하여 초음파 신호를 측정하므로 우수한 측정 분해능을 제공한다. 본 연구에서는 이종금속 접촉부식(갈바닉 부식) 현상을 레이저를 이용한 비파괴, 비접촉 방법으로 측정하였다. 부식된 부분에 이물질이 혼합되는 경우를 가정하고, 레이저 초음파 실험을 진행하였다. 시편의 뒷면에서 펄스 레이저로 초음파를 발생시키고, 같은 위치의 앞면에서 CW 레이저와 CFPI를 이용하여 초음파 신호를 획득하였다. 이물질이 존재하는 부분의 초음파 신호 특성을 분석하여 이물질의 위치 및 크기를 측정하였다.

직사각형 다중 양자 우물 도파관의 모드특성 분석 : Scanning angle method를 사용한 새로운 접근 (Modal Analysis of Rectangular MQW Waveguide : A Novel Approach using Scanning Angle Method)

  • 임연섭;최영완
    • 대한전자공학회논문지SD
    • /
    • 제37권4호
    • /
    • pp.45-52
    • /
    • 2000
  • 본 논문에서는 직사각형 다중 양자 우물 광 도파관의 간단하고 효율적인 분석을 위한 새로운 모의 실험방법을 제시한다. 우선적으로 2 차원 도파관 구조는 유효 굴절률 법을 사용하여 1 차원 도파관 구조로 변형되고 이렇게 얻어진 등가의 평면 다중 양자 우물 도파관의 도파 특성 행렬은 새롭게 제시된 각도 스캔법(scanning angle method)에 의하여 분석된다. 직사각형 다중 양자 우물 도파관의 유효 굴절률, 모드 전장세기, 광 구속 인자는 이 방법을 사용하여 효율적으로 얻을 수 있다. 모의 실험결과는 유한 요소 법에 기초된 해와 거의 정확한 일치를 보인다. 또한 직사각형 다중 양자 우물 도파관의 분석을 위한 두 가지의 근사 해석 방식을 새롭게 도입하고 그 방식들의 유효성을 검증하였다. 퍼터베이션 분석(perturbation analysis)을 사용하여 직사각형 다중양자 우물 도파관에서 전송되는 모드의 전력 손실 계수를 새롭게 유도하고 평면 다중 양자 우물 도파관 근사를 사용한 전형적인 방법의 결과와 비교하였다.

  • PDF

UHF 대역 CP 스파이럴 RFID 리더 안테나 설계 (Design of a CP Spiral RFID Reader Antenna in UHF Band)

  • 이주용;추호성;박익모;한원근
    • 한국전자파학회논문지
    • /
    • 제19권5호
    • /
    • pp.562-571
    • /
    • 2008
  • 본 논문에서는 스파이럴 구조를 이용하여 UHF 대역에서 원형 편파 특성을 가지는 RFID 리더 안테나를 제안하였다. 제안된 안테나는 FR-4 기판에 스트립 라인으로 인쇄되어 대량 생산이 용이한 평면 구조이며, UHF RFID 주파수 대역폭($860{\sim}960$ MHz)을 만족시킬 수 일도록 설계하였다. 또한, 본체를 스파이럴 구조로 제작하여 원형 편파 특성이 광대역($860{\sim}960$ MHz)에서 일어날 수 있도록 하였으며, 급전 부분은 0.25 $\lambda$ 정합기를 사용하여 임피던스 정합이 이루어지도록 하였다. 제안된 안테나는 복사 이득과 복사 패턴의 조절이 용이하고, 크기가 소형화되었음에도 불구하고 광대역에서 임피던스 정합 및 원형 편파 특성을 유지할 수 있다. 측정 결과, 제작된 안테나는 반사 손실 대역폭 13%, 원형 편파 대역폭 23%의 특성을 가지고, 동작 주파수 대역에서 약 6.5 dBi의 복사 이득을 가져, RFID 리더 안테나로 활용할 수 있음을 확인하였다.

경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성 (Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy)

  • 임정환;송준혁;신규만;김성학
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF