• Title/Summary/Keyword: Characteristic

Search Result 30,204, Processing Time 0.056 seconds

Hydrodynamic performance of a pump-turbine model in the "S" characteristic region by CFD analysis

  • Singh, Patrick Mark;Chen, Chengcheng;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.10
    • /
    • pp.1017-1022
    • /
    • 2015
  • Specific hydrodynamic characteristic of pump-turbine during the start and load rejection process of generating mode causes anomalous increase of water pressure, along with large machine vibration, called "S" characteristic. The aim of this study is to understand and explain the hydrodynamic performance of pump-turbine at "S" characteristic region by using a model of pump-turbine system. The operation in the condition of runway and low discharge in a typical "S" characteristic curve may become unstable and complex flow appears at the passage of guide vane and impeller. Therefore, velocity and pressure distribution are investigated to give an all-sided explanation of the formation and phenomenon of this characteristic, with the assistance of velocity triangle analysis at the impeller inlet. From this study, the internal flow and pressure fluctuation at the normal, runway and low discharge points are explored, giving a deep description of hydrodynamic characteristic when the pump-turbine system operates with "S" characteristic.

The Analysis of Children's Private Speech on Age and Characteristic of Task (연령 및 과제특성에 따른 유아들의 혼잣말 발화 분석)

  • Lee, Jeong-Hwa;Park, Jeong-Eon;Lee, Myeong-Hee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.24 no.4
    • /
    • pp.494-506
    • /
    • 2012
  • The purpose of this study was to analyse 3, 4, 5-year-old children's private speech according to their age and task characteristics (structured task vs. unstructured task). In order to achieve the goal, the main effect of age, characteristic of tasks and interaction effect were considered among age and characteristic of tasks on preschool children's private speech. The subjects were each 30 3, 4, 5-year-olds from preschool in Busan, South Korea. The structured task was puzzle task and the unstructured task was drawing task from TCT-DP. The data was analyzed by repeated measurement two way ANOVA: 3(age) ${\times}$ 2((characteristic of task). As a result, firstly, total private speech of 4-year-old was higher than 3-year-old, 5-year-old in both tasks, and total private speech of 5-year-old was higher than 3-year-old in both tasks. Secondly, the task-irrelevant private speech was not affected by main effect of age and characteristic of task and interaction effect between age and characteristic of task. Thirdly, the task-relevant private speech was received both main effects and interaction effects between age and characteristic of task. Finally, the external manifestation of inner speech were not received effect of age but received effect of characteristic of task, and received interaction effect between age and characteristic of task. The results of this study imply that characteristic of task is an important factor inducing children's private speech.

A SPLIT LEAST-SQUARES CHARACTERISTIC MIXED FINITE ELEMENT METHOD FOR THE CONVECTION DOMINATED SOBOLEV EQUATIONS

  • OHM, MI RAY;SHIN, JUN YONG
    • Journal of applied mathematics & informatics
    • /
    • v.34 no.1_2
    • /
    • pp.19-34
    • /
    • 2016
  • In this paper, we present a split least-squares characteristic mixed finite element method(MFEM) to get the approximate solutions of the convection dominated Sobolev equations. First, to manage both convection term and time derivative term efficiently, we apply a least-squares characteristic MFEM to get the system of equations in the primal unknown and the flux unknown. Then, we obtain a split least-squares characteristic MFEM to convert the coupled system in two unknowns derived from the least-squares characteristic MFEM into two uncoupled systems in the unknowns. We theoretically prove that the approximations constructed by the split least-squares characteristic MFEM converge with the optimal order in L2 and H1 normed spaces for the primal unknown and with the optimal order in L2 normed space for the flux unknown. And we provide some numerical results to confirm the validity of our theoretical results.

Experimental Study for Soil-Water Characteristic Curves of Unsaturated Soil (불포화토의 흙-수분 특성곡선에 관한 실험적 고찰)

  • 송창섭;김명환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.6
    • /
    • pp.153-161
    • /
    • 2003
  • The purpose of this paper is to investigate the soil-water characteristic curves for an unsaturated soil. To this ends, a series of suction measured test was conducted on the selected 4 kinds of soils taken from different sites of Korea, using modified pressure plate apparatus. Form the test results, the water contents, degree of saturation and volumetric water contents were analyzed with the suction. And the soil-water characteristic curves of unsaturated soil were drawn from the test results for various factors. The characteristic curves drawn with water content vs matric suction were classified certainly the difference in wet side but were not classified in dry side. The characteristic curves drawn with degree of saturation vs matric suction for unsaturated soil were shown the opposite inclination as compared with the former curve. But the characteristic curve with volumetric water content vs matric suction was described suitably not only in wet side condition but also in dry side. And it was found that the volumetric water contents of loose soil was high at the initial condition but that of dense soil was high at final condition (dry side).

A Study of Korean (Industrial) Standards for Pneumatic Servo Valve (공압서보밸브 KS규격 정립에 관한 연구)

  • 김동수;이원희;최병오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1231-1234
    • /
    • 2003
  • Pneumatic servo valve which is widely applied in industrial world is advanced technology compounded with electric, electronic and machine. And It is consist of Linear Force Motor. Spool Commutation Mechanism and Microprocessor. In this study, we accomplished test method of Linear Force motor test, Static characteristic test, Dynamic characteristic test for KS(Koran industrial standard) of Pneumatic servo valve. we accomplished study about the main item of Static characteristic test which is related to unload flow characteristic test. And Dynamic characteristic test was step input test and frequency response test. Specially about frequency response test, There was a difficulty resulting from the time delay problem caused by the basic compressibility of air. In order to solve the problem in this study. we proposed two methods. First, displacement of the servo valve spool was directly measured by using a laser sensor. Second, method of calculating control flow by measuring pressure and temperature of chamber.

  • PDF

A Study for Parking Characteristic of Parking Operation Method (주차장 운영방식에 따른 주차특성 분석)

  • Jung, Ki-Soo;Lee, Young-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.1
    • /
    • pp.5-13
    • /
    • 2010
  • Industrialization and urbanization occurred-traffic delay, traffic accident and parking problem etc.-variety of transportation problems. Parking problem is one of the transportation problem then transportation engineers would get involved in trying to solve parking problem. A way to overcome a variety of parking problems needs preliminary data for conditions of parking but it lacks the preliminary data to do so. Thus this study analyzed a characteristic of a parking through a field survey for parking in Daegu Metropolitan City. This study analyzed parking characteristic of parking operation method. This study result reveals difference between a toll parking and a no charge parking characteristic. Thus a close examination for a toll parking characteristic and a no charge parking characteristic is a prerequisite for a rational parking policy.

  • PDF

A Study for Communication Mode of Bus Information System (도시별·용도지역별 주차특성 분석)

  • Lee, Young-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.3
    • /
    • pp.113-120
    • /
    • 2008
  • Rapid urbanization occurred a variety of transportation problems. Parking problem is one of the most problems of transportation problem then transportation engineers would get involved in trying to solve parking problem. A way to overcome a variety of parking problems needs preliminary data for conditions of parking but it lacks the preliminary data to do so. Thus this study analyzed a characteristic of a parking through a field survey for parking in Daegu Metropolitan City and Ulsan Metropolitan City. This study analyzed parking turnover, parking use ratio and parking basic unit for characteristic of a parking of each use districts and each cities. This study result reveals difference between the use districts' parking characteristic and cities' parking characteristic. Thus a close examination for use districts' parking characteristic and cities' parking characteristic is a prerequisite for a rational parking policy.

  • PDF

A Numerical Method for Strength Analysis of Composite Joints (복합재 체결부 강도해석을 위한 새로운 수치해석방법)

  • Kang BongSoo;Jung JaeWoo;Kweon Jin-Hwe;Choi Jin-Ho
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.202-205
    • /
    • 2004
  • A numerical method is presented to determine the characteristic lengths for the failure analysis of composite joints without characteristic length tests. In the conventional methods, compressive characteristic length was determined from the result of a combined bearing test and finite element analysis. The present study, however, shows that the same compressive characteristic length can be obtained by numerical calculation without the bearing test. A new method to define the tensile characteristic length is also introduced so that the tensile characteristic length is numerically determined without the tensile test. Failure loads based on the numerically calculated characteristic lengths are validated by the test results for composite joints

  • PDF

A Study on Soil-Water Characteristic Curves of Reclaimed Soil and Weathered Granite Soil (준설매립토 및 화강풍화토의 흙-수분 특성곡선에 관한 연구)

  • 신은철;이학주;김환준
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.743-750
    • /
    • 2002
  • Unsaturated soil has a possibility to induce a negative pore water pressure. Until now, saturated soil is mainly focused on the research of soil mechanics. Recently, soil mechanics is researched on two major parts such as saturated and unsaturated soil mechanics. Negative pore water pressure has a non-linear relationship with the water content changes. Soil-water characteristic curves of soil in Korea are not determined. There is no proper characteristic value such as air-entry value and residual water content. In this study, the characteristic curves of reclaimed soil, sand, and weathered granite soil were determined by laboratory tests. Air-entry value and residual water content were determined by fitting methods. Soil-water characteristic curves were estimated based on the particle-size distribution and compared with the laboratory test results. The results of soil-water characteristic curves estimation indicated that Fredlund and Wilson's model is excellent for sand and weathered granite soil. Arya and Paris's model is excellent for reclaimed soil.

  • PDF

Analysis of Characteristic Frequency along Fault Distance on a Transmission Line (송전 선로의 사고 거리에 따른 특성 주파수 해석)

  • 남순열;홍정기;강상희;박종근
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.8
    • /
    • pp.432-437
    • /
    • 2004
  • Since the characteristic frequency is decreased in proportion to the fault distance, the characteristic frequency component may be insufficiently eliminated by a low-pass filter on a long transmission line. In order to set a standard for the cut-off frequency of the low-pass filter, this paper proposes a method for obtaining the characteristic frequencies due to line faults. The application results of the proposed method are presented for line to ground (LG) faults and line to line (LL) faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault signals under different fault locations and fault inception angles. By comparison between the characteristic frequencies obtained from the proposed method and the EMTP simulation, it is shown that the proposed method accurately obtains the characteristic frequency.