• 제목/요약/키워드: Changing factor

검색결과 1,165건 처리시간 0.033초

헬멧형 뇌자도 장치로의 활용을 위한 Pb 초전도 차폐의 특성 (Characteristics of Superconductive Pb shield for a Whole Head MEG System)

  • 유권규;김기웅;이용호
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.30-35
    • /
    • 2009
  • We have investigated the characteristics of a superconductive Pb shield for hemispherical shape and plate to improving signal-to-noise ratio(SNR) of biomagnetism. We measured the shielding factor for the position of helmet shape Pb and for changing the distance from Pb surface. To make a uniform magnetic field, a $1.5m{\times}1.5m$ set of the helmholtz coils activated at several frequencies. The shielding factor of hemispherical shape Pb was from 20 to 57 dB and of Pb plate was about $6{\sim}26dB$ as a function of distance from the lead surface. The shielding factor was rapidly reduced as increasing the distance from Pb surface. The white noise of superconductive quantum interference device(SQUID) with a superconductive shield was about $12fT/Hz^{1/2}$ at 1 Hz, $7fT/Hz^{1/2}$ at 100 Hz. The white noise was more increased about two times than conventional SQUID system without Pb shielding. An auditory signal was measured by first order gradiometer and magnetometer with Pb superconductive shield and compared the SNR. The SQUID system with Pb shield had better performance at low frequency noise level.

  • PDF

미립잠열슬러리의 유체역학적 특성연구 (Fluid dynamical characteristics of microencapsulated phase change material slurries)

  • 이효진;이승우;이재구
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.549-559
    • /
    • 1999
  • An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.

  • PDF

상용관 마찰계수에 따른 관망해석 (Pipe Network Analysis according to Friction Factor of Commercial Pipe)

  • 유동훈;원유승;윤계섭
    • 물과 미래
    • /
    • 제29권5호
    • /
    • pp.161-172
    • /
    • 1996
  • 상용관 마찰계수 산정을 위해 개발된 기존의 Hazen-Williams 식, Colebrook-White 식과 유동훈(1995)이 제안한야 영점높이 평균법과 마찰계수 평균법의 산정식들을 비교 검토하였다. 간단한 관망에 대하여 관종류, 관경, 유속, 관길이를 변화시켜 수리조건을 구성하였으며, 네가지 상용관 마찰계수 산정식을 적용하여 구한 압력차이를 비교하여 각각의 산정식들이 가지는 특징을 논하였고, 입력자료의 변화에 따라 마찰손실이 어떠한 거동을 하는지 알아보았다. 관경을 소형관 및대형관으로 변화시켰을 때의 분석결과와 중형관일 때의 분석결과를 세 종류의 강관에 대하여 비교하였고, 유속 변화와 압력 변화와의 비교를 통하여 기존 상용관 마찰 계수 산정식의 문제점에 대하여 논하였다.

  • PDF

점호각을 고려한 유도전동기의 소프트 기동 특성 해석 (Analysis of Soft Start-up Characteristics of the Induction Motor Considering the Firing Angle)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1007-1012
    • /
    • 2016
  • Induction motors are used widely in driving load of a fluid, such as a pump or a fan in the industry. Induction motor has been generated the voltage drop by the occurrence of a high current during startup. In addition, high start-up current can act as a mechanical stress on the shaft of the motor. So there is need a way to reduce the starting current. Soft start method is one of the many ways to reduce the starting current. This method uses silicon-controlled rectifiers(SCRs) for varying value of the voltage applied to the motor. There is a case for fixing or changing the thyristor firing angle to adjust the magnitude of the voltage. Starting power factor of induction motor is very low compared to the normal operation. Soft starting with the firing angle fixed needs to be considered a low power factor at startup. In this study, we compared the direct start characteristics and soft start characteristics considering the low power factor at the time of start-up. It was possible to confirm that the starting current and the voltage drop is present differently according to the firing angle.

심벌형 압전 에너지 하베스터 에너지 수율 향상 연구 (Research on the Efficiency Improvement of the Cymbal-type Piezoelectric Energy Harvester)

  • 나영민;박종규
    • 한국기계가공학회지
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 2017
  • The pollution problem of fossil energy sources has caused the development of green energy harvesting systems. Piezoelectric energy harvesting technology has been developed under those external environmental factors. A piezoelectric energy harvester can be defined as a device which transforms mechanical vibration or impact energy into electrical energy. Most researches have focused on bender structures. However, these have a limitation on energy efficiency because of the small effective electromechanical coupling factor, around 10%. Therefore, we should look for a new design for energy harvesting. A cymbal energy harvester can be a good candidate for the high-power energy harvester because it uses a high amplification mechanism using endcaps while keeping a higher electromechanical coupling factor. In this research, we focused on energy efficiency improvements of the cymbal energy harvester by changing the polarization direction, because the electromechanical coupling factor of the k33 mode and the k15 mode is larger than that of the k31 mode. Theoretically, we checked the cymbal harvester with radial polarization and it could obtain 6 times larger energy than that with the k31 direction polarization. Furthermore, we verified the theoretical expectation using the finite element method program. Consequently, we could expect a more efficient cymbal harvester with the radial polarization by comparing two polarization directions.

PVDF/PDMS 복합막의 제조와 투과증발을 이용한 n-부탄올/물 혼합물의 분리 (Preparation of PVDF/PDMS Composite Membrane and Separation of n-butanol/water Mixtures by Pervaporation)

  • 이용택;지기용;전은주;김노원
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.212-221
    • /
    • 2009
  • 본 연구는 PVDF/PDMS 복합막을 제조하여 부탄올을 농축을 위한 투과증발특성에 대해 알아보았다. 또한 복합막의 제조 방법에 따른 투과특성을 알아보기 위해 지지층의 PVDF 농도변화와 활성층의 경화조건에 따라 투과증발 최적막을 선정하였다. 이 막을 사용하여 공급액의 농도, 온도 및 순환 유속을 변화시켜 부탄올의 투과특성에 미치는 영향에 대해 알아보았다. 그 결과 공급액의 농도, 온도, 순환 유속이 증가할 경우 부탄올의 플럭스와 투과 농도가 증가함을 확인하였으며 상용막인 GKSS사의 PVDF/POMS 복합막과 비교한 결과 부탄올 투과 플럭스, 투과 농도, 선택도 등 모두 높은 값을 나타내었다.

감압용 배수탱크내의 분기형 증기분사기의 유동특성에 관한 연구 (A Study on Flow Characteristics of Branch Type Sparger in Drain Tank for Depressurization)

  • 김광추;박만흥;박경석
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.356-367
    • /
    • 2001
  • A numerical analysis on branch type sparger in drain tank for depressurization is performed to investigate the flow characteristics due to the change of design factor. As the result of this study, sparger\\`s flow resistance coefficient(K) is 3.53 at the present design condition when engineering margin for surface roughness is considered as 20%, and flow ratio into branch pipe ($Q_s/Q_i$) is 0.41. The correlation for calculating flow resistance coefficients as design factor is presented. Flow resistance coefficient is increased as section area ratio of branch pipe for main pipe and outlet nozzle diameter of main pipe decreasing, but the effects of branch angle and inlet flow rate of main pipe are small. As the change rate of ($Q_s/Q_i$)becomes larger, the change rate of flow resistance coefficient increases. The rate of pressure loss has the largest change as section area ratio changing. The condition of maximum flow resistance in sparger is when the outlet nozzle diameter ratio of main pipe ($D_e/D_i$) is 0.167, the section area ratio ($A_s/A_i$) is 0.1 and the branch angle ($\alpha$) is 55^{\circ}$.

  • PDF

한국무역항만 총요소생산성 증가의 원동력에 관한 연구 (A Study on Source of Total Factor Productivity Growth of Trade Ports in Korea)

  • 곽염;김한신;이창호
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.183-190
    • /
    • 2010
  • This paper selects length of berth, area of yard, unloading capacity and number of berth as the input indexes, and cargo turnover as output index to research the source of TFP(Total Factor Productivity) growth of 23 main ports in Korea. The major conclusions are as follows. The TFP of the trade ports in Korea is at the fluctuating stage, but it generally displays a rising trend, and it’s growth originate from the growth of technical efficiency. The Growth rates of TFP of trade ports in the different areas are different, and the sources of growth are also different, but the changing trends are basically the same. Four major factors to the increase of TFP are following: competition between ports, reform of property system, harbor-hinterland economic and international trade, modeling, imitation and innovation in management, technology and system.

Effects of Process Variables on the Gas Penetrated Part in Gas-Assisted Injection Molding

  • Han, Seong-Ryeol;Park, Tae-Won;Jeong, Yeong-Deug
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.8-11
    • /
    • 2006
  • Gas-assisted injection molding (GAIM) process reduces the required injection pressure during mold filling stage as well as the shrinkage and warpage of the part and cycle time. Despite of these advantages, this process needs new parameters and makes the application more difficult because gas and melt interact during the injection molding process. Important GAIM factors involved in this process are gas penetration design, locations of gas injection points, shot size, delay time to inject gas as well as common injection molding parameters. In this study, the experiments are conducted to investigate effects of GAIM process variables on the gas penetration for PP (Polypropylene) and ABS (Acrylonitrile Butadiene Styrene) moldings by changing the gas injection point. Taguchi method is used for the design of the experiments. When the gas is injected at a cavity's center, the most effective factor is the shot size. When the gas is injected at a cavity's end, the most effective factor is the melt temperature. The injection speed is also an effective factor in GAIM process.

차세대 장수명화를 위한 가변성능요소의 분석과 적용에 관한 연구;공동주택을 중심으로 (A Study on Analysis and Application of Factor of Improving the Flexibility for a long life housing at the Next Generation;Focusing on Apartment Housing)

  • 이정석;안병주;이윤선;김재준
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2007년도 정기학술발표대회 논문집
    • /
    • pp.943-946
    • /
    • 2007
  • 최근 가변성능에 관하여 공간, 재료, 구조, 공법 등 건설 산업 전반에 걸쳐 많은 연구가 진행 중이다. 시대적인 주거환경 변화, 미래지향적인 건설 트랜드 변모 그리고 수요중심적인 인식을 만족하기 위해서 주택의 모습과 공간, 형식이 진화되어가고 있다. 이에 따라 본 연구에서는 가변성을 지니고 있는 건축의 성능요소들을 비교 분석하여 대안을 제시하고자 하며, 적용 가능한 다양한 분류예시를 통하여 실제적인 차세대 장수명화를 실현시키기 위한 방향과 지침을 제시하고자한다.

  • PDF