• Title/Summary/Keyword: Change-point analysis

Search Result 1,300, Processing Time 0.032 seconds

Analysis of Heating Effect of an Infrared Heating System in a Small Venlo-type Glasshouse (소형 벤로형 유리온실에서 적외선등 난방 시스템의 난방효과 분석)

  • Lim, Mi Young;Ko, Chung Ho;Lee, Sang Bok;Kim, Hyo Kyeong;Bae, Yong Han;Kim, Young Bok;Yoon, Yong Cheol;Jeong, Byoung Ryong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.3
    • /
    • pp.186-192
    • /
    • 2010
  • An infrared heating system, installed in a small venlo-type glasshouse ($280m^2$) in Gyeongsang National University, Jinju, Korea, was used to investigate its heating effect with potted Phalaenopsis, Schefflera arboricola 'Hongkong', Ficus elastica 'Variegata', and Rosa hybrida 'Yellow King' as the test plants. Temperature changes in test plants with the system turned 'On' and 'Off' were measured by using an infrared camera and the consumption of electricity by this infrared heating system was measured and analyzed. In potted Phalaenopsis, when the set air temperature of the greenhouse was $18^{\circ}C$, temperature of leaves and the growing medium were $22.8{\sim}27^{\circ}C$ and $21.3{\sim}24.3^{\circ}C$, respectively. In such tall plants as Schefflera arboricola 'Hongkong' and Ficus elastica 'Variegata', the upper part showed the highest temperature of 24.0 and $26.9^{\circ}C$, respectively. From the results of temperature change measurements, the plant temperatures were near or above the set point temperatures with some fluctuations depending on the position or distance from the infrared heating system. When air temperature between night and dawn dropped sharply, plant temperatures were maintained close to the set temperature ($18^{\circ}C$). There was a significant difference between 'On' and 'Off' states of the infrared heating system in average temperatures of root zone and leaf: 21.8 and $17.8^{\circ}C$ with the system 'On' and 20.4 and $15.5^{\circ}C$ with the system 'Off', respectively, in a cut rose Rosa hybrida 'Yellow King'. The heating load was about $24,850{\sim}35,830kcal{\cdot}h^{-1}$, which comes to about 27,000~40,000 won in Korean currency when calculated in terms of the cost of heating by a hot water heating system heated by petroleum. The cost for heating by the infrared heating system was about 35% of that of a hot water heating system. With the infrared heating system, the air temperature during the night was maintained slightly lower than the set point air temperature, probably due to the lack of air tightness of the glasshouse. Therefore, glasshouses with an infrared heating system requires further investigation including the installation space of the heat-emitting units, temperature sensor positions, and convection.

The Effects of Environmental Dynamism on Supply Chain Commitment in the High-tech Industry: The Roles of Flexibility and Dependence (첨단산업의 환경동태성이 공급체인의 결속에 미치는 영향: 유연성과 의존성의 역할)

  • Kim, Sang-Deok;Ji, Seong-Goo
    • Journal of Global Scholars of Marketing Science
    • /
    • v.17 no.2
    • /
    • pp.31-54
    • /
    • 2007
  • The exchange between buyers and sellers in the industrial market is changing from short-term to long-term relationships. Long-term relationships are governed mainly by formal contracts or informal agreements, but many scholars are now asserting that controlling relationship by using formal contracts under environmental dynamism is inappropriate. In this case, partners will depend on each other's flexibility or interdependence. The former, flexibility, provides a general frame of reference, order, and standards against which to guide and assess appropriate behavior in dynamic and ambiguous situations, thus motivating the value-oriented performance goals shared between partners. It is based on social sacrifices, which can potentially minimize any opportunistic behaviors. The later, interdependence, means that each firm possesses a high level of dependence in an dynamic channel relationship. When interdependence is high in magnitude and symmetric, each firm enjoys a high level of power and the bonds between the firms should be reasonably strong. Strong shared power is likely to promote commitment because of the common interests, attention, and support found in such channel relationships. This study deals with environmental dynamism in high-tech industry. Firms in the high-tech industry regard it as a key success factor to successfully cope with environmental changes. However, due to the lack of studies dealing with environmental dynamism and supply chain commitment in the high-tech industry, it is very difficult to find effective strategies to cope with them. This paper presents the results of an empirical study on the relationship between environmental dynamism and supply chain commitment in the high-tech industry. We examined the effects of consumer, competitor, and technological dynamism on supply chain commitment. Additionally, we examined the moderating effects of flexibility and dependence of supply chains. This study was confined to the type of high-tech industry which has the characteristics of rapid technology change and short product lifecycle. Flexibility among the firms of this industry, having the characteristic of hard and fast growth, is more important here than among any other industry. Thus, a variety of environmental dynamism can affect a supply chain relationship. The industries targeted industries were electronic parts, metal product, computer, electric machine, automobile, and medical precision manufacturing industries. Data was collected as follows. During the survey, the researchers managed to obtain the list of parts suppliers of 2 companies, N and L, with an international competitiveness in the mobile phone manufacturing industry; and of the suppliers in a business relationship with S company, a semiconductor manufacturing company. They were asked to respond to the survey via telephone and e-mail. During the two month period of February-April 2006, we were able to collect data from 44 companies. The respondents were restricted to direct dealing authorities and subcontractor company (the supplier) staff with at least three months of dealing experience with a manufacture (an industrial material buyer). The measurement validation procedures included scale reliability; discriminant and convergent validity were used to validate measures. Also, the reliability measurements traditionally employed, such as the Cronbach's alpha, were used. All the reliabilities were greater than.70. A series of exploratory factor analyses was conducted. We conducted confirmatory factor analyses to assess the validity of our measurements. A series of chi-square difference tests were conducted so that the discriminant validity could be ensured. For each pair, we estimated two models-an unconstrained model and a constrained model-and compared the two model fits. All these tests supported discriminant validity. Also, all items loaded significantly on their respective constructs, providing support for convergent validity. We then examined composite reliability and average variance extracted (AVE). The composite reliability of each construct was greater than.70. The AVE of each construct was greater than.50. According to the multiple regression analysis, customer dynamism had a negative effect and competitor dynamism had a positive effect on a supplier's commitment. In addition, flexibility and dependence had significant moderating effects on customer and competitor dynamism. On the other hand, all hypotheses about technological dynamism had no significant effects on commitment. In other words, technological dynamism had no direct effect on supplier's commitment and was not moderated by the flexibility and dependence of the supply chain. This study makes its contribution in the point of view that this is a rare study on environmental dynamism and supply chain commitment in the field of high-tech industry. Especially, this study verified the effects of three sectors of environmental dynamism on supplier's commitment. Also, it empirically tested how the effects were moderated by flexibility and dependence. The results showed that flexibility and interdependence had a role to strengthen supplier's commitment under environmental dynamism in high-tech industry. Thus relationship managers in high-tech industry should make supply chain relationship flexible and interdependent. The limitations of the study are as follows; First, about the research setting, the study was conducted with high-tech industry, in which the direction of the change in the power balance of supply chain dyads is usually determined by manufacturers. So we have a difficulty with generalization. We need to control the power structure between partners in a future study. Secondly, about flexibility, we treated it throughout the paper as positive, but it can also be negative, i.e. violating an agreement or moving, but in the wrong direction, etc. Therefore we need to investigate the multi-dimensionality of flexibility in future research.

  • PDF

Clinical Study of Corrosive Injury of the Esophagus (식도부식증의 임상적 고찰)

  • 박철원;송기준;이형석;안경성;김선곤
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.5.3-6
    • /
    • 1981
  • There are too many kinds of esophageal corrosive agents, such as sodium hydrochloride, acetic acid, hydrochloric acid, etc. Esophageal burn due to above chemical agents are decreasing recently, but still many patients visited to the hospital because of swallowing corrosive agents for the purpose of suicide or accidentally. Among the treatment of corrosive injury of the esophagus, prevention of esophageal stricture is the key point. Recently various methods are using as the treatment of corrosive esophagitis and prevention of esophageal stricture. 51 cases of corrosive injury of the esophagus who had been admitted and treated at the Dept. of Otolaryngology, Han Yang University Hospital during past 9 years (from May 1972 to Dec. 1980) were evaluated and report the result about age distribution, sex incidence, monthly distribution, cause of swallowing, swallowing agents, arriving time at hospital after swallowing, changes on oral and pharyngeal mucosa, laboratory findings, emergency treatment and treatment during admission, treatment follow up results and complications with review of liter ature. Following results were obtained; 1. Female patients 27 cases (52.9%) were more than male patients 24 cases (47.1%) and its ratio was 1.13 : 1. 2. Age distribution showed predilection for age of 21-30 with 20 cases(39.2%), and 11-20 with 11 cases (21.6%), 31-40 with 7 cases(13.7%), over 50 with 7 cases (13.7%) were following. 3. Monthly distribution showed predilection for March with 8 cases(15.7%), and April, July with 7 cases (13.7%), September with 6 cases(l1.8%), October 5 cases(9.8%) were following. 4. For the purpose of suicide was the most cause of swallowing with 40 cases(78.4%), and accidentally swallowing 11 cases(21.6%). 5. Acetic acid was the most swallowing agent with 24 cases (47.0%), and hydrochloric acid 11 cases (21.5%), lye 8 cases(15.7%), iodine 2 cases(3.9%) were following. 6. Arriving time at the hospital after swallowing showed predilection for within 12 hours with 42 cases (82.4%), and from 12 hours to 24 hours with 4 cases(7.8%) was next. 7. Moderate change with injection and swelling was the prevalent change on oral and pharyngeal mucosa with 20 cases(39.2%) and severe cases with ulceration 18 cases (35.3%), mild cases with injection 10 cases (19.6%) were following. 8. Leukocytosis was seen on 40 cases (78.4%), and increased Hct. was seen 31 cases (60.8%). On urine analysis, 14 cases(27.5%) showed over 1.030 S.G., and proteinuria was seen on 25 cases(49.0%), glycosuria was seen on 5 cases(9.8%) and hematuria was seen on 6 cases(11.8). 9. Gastric lavage was done on 30 cases (58.8%) as emergency treatment and on 3 cases(5.9%) tracheostomy was done for the airway keeping. 10. As methods of treatment during admission, L-tube insertion was done on 50 cases (98.0%), antibiotics was given to 49 cases (96.1%), steroid and antacid were given to 46 cases(90.2%). 11. 36 cases(70.6%) were in favorable condition after proper treatment, but 2 cases (3.9%) were expired during admission, 4 cases (7.8%) showed esophageal stricture in-spite of treatment, and 1 case(2.0%) showed pyloric stenosis. 12. Complications were observed in 8 cases (17.7%). Renal failure (4 cases), aspiration pneumonia (2 cases), upper G-I bleeding (1 cases), and diabetic coma (1 cases) were seen in order of frequency.

  • PDF

The Kinematic Analysis of the Pitching motion for the Straight and Curve ball (직구와 커브 투구동작의 운동학적 비교 분석)

  • Lee, Young-Jun;Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.109-130
    • /
    • 2002
  • The purpose of this paper was to make a comparative analysis for the difference of the various kinematic variation which is occurred in the each situation when pitchers throw a straight and a curve ball. Four pitchers, who are two national team players and two high level pitchers, were selected among the right over hand pitchers of D university in the Busan for this paper. The data were analyzed by using 3D equipment. The results of the analysis which was about the elapsed time of the pitching, the movement of the body center-point, the highest height of the left knee, stride length, knee joint angle, shoulder joint angle, elbow joint angle and wrist joint angle in the each section(ST, LKU, HBP, LCF, MCP, BRP) were as follows : 1. Pitching time in the each section and step in the pitching for straight and curve ball was similar. The total elapsed time of the straight and curve ball was 1.78${\pm}$0.07sec and 1.77${\pm}$0.11sec in the order. 2. The position change of the body center to the Z(above below) direction did not show significant difference in the each situation of the section and step between pitching for the straight and curve ball. 3. Height of the left knee did not show significant difference as 125.38${\pm}$11.85cm and 124.95${\pm}$11.63m in the each pitching motion for straight and curve ball. The rate(%H) between height and stride length showed 68.42${\pm}$5.53(%H), 68.40${\pm}$5.45(%H) in the each pitching motion. 4. Pitching for curve ball showed longer stride length than pitching for straight ball that as the stride length was 140.35${\pm}$4.96cm and 144.8${\pm}$1.69cm. The rate(%H) between height and stride length showed 76.9${\pm}$3.77(%H), 79.39${\pm}$2.23(%H) in the each pitching motion. 5. Left knee joint angle did not show significant difference in the ST, LKU and HBP section in the each pitching motion. However, it was shown that knee joint angle was flexed much more in the LFC, MCP and BRP section in the pitching for curve ball. 6. Right shoulder joint angle did not show significant difference in the ST, LKU and HSP section. However, when pitches threw a curve ball in the LKU section. In the LFC section, the right shoulder joint angle was extended much more in the pitching for curve ball, and the angle was extended much in the MCP and BRP section in the pitching for curve ball than straight ball. 7. Right elbow joint angle did not show significant difference in the ST, LKU and HRP section in the two pitching motion. The angle had more flexion in the LFC and MCP section in the pitching for curve ball than the pitching for straight ball. The angle in the each pitching motion for straight ball and curve ball were extended by a narrow margin in the BRP section. 8. Right wrist joint angle was extended much more in the LFC and MCP section in the pitching for curve ball. In the BRP section, the angle was extended much more in the pitching for straight ball than curve ball.

Evaluation for Rock Cleavage Using Distribution of Microcrack Spacings (II) (미세균열의 간격 분포를 이용한 결의 평가(II))

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.151-163
    • /
    • 2016
  • The characteristics of the rock cleavage in Jurassic granite from Geochang were analysed. The evaluation for the three directions of rock cleavages was performed using the parameters such as (1) frequency of microcrack spacing(N), (2) total spacing(${\leq}1mm$), (3) mean spacing($S_{mean}$), (4) difference value($S_{mean}-S_{median}$) between mean spacing($S_{mean}$) and median spacing($S_{median}$), (5) density of spacing(${\rho}$), (6) difference value between two exponents for the whole range of the diagrams(${\lambda}_H-{\lambda}_L$), (7) mean value of exponent(${\lambda}_M$), (8) mean value of exponential constant($a_M$), (9) difference value between two exponents for the section under the initial points of intersection(${\lambda}t_H-{\lambda}t_L$), (10) mean value of exponent(${\lambda}t_M$) and (11) mean value of exponential constant($at_M$). The results of correlation analysis between the values of parameters for three rock cleavages and those for three planes are as follows. The values of (I) parameters(1, 2, 7 and 8) and (II) parameters(3, 4 and 5) are in orders of (I) H(hardway, (H1 + H2)/2) < G(grain, (G1 + G2)/2) < R(rift, (R1 + R2)/2) and (II) R < G < H. On the contrary, the values of the above two groups(I~II) of parameters for three planes show reverse orders. Besides, the values of parameter $6({\lambda}_H-{\lambda}_L)$, parameter $9({\lambda}t_H-{\lambda}t_L)$, parameter $10({\lambda}t_M)$ and parameter $11(at_M)$ for three planes are in orders of R(rift plane, (G1 + H2)/2) < H(hardway plane, (R2 + G2)/2) < G(grain plane, (R1 + H2)/2), H < G < R, H < R < G and R < H < G, respectively. The values of the above four parameters for three rock cleavages show the various orders of R < H < G, R < H < G, H < G < R and H < G < R, respectively. Meanwhile, the spacing values equivalent to the initial points of contact and intersection between the two directions of diagrams were derived. The above spacing values for three rock cleavages are in order of rift(R1 and R2) < grain(G1 and G2) < hardway(H1 and H2). The spacing values for three planes are in order of rift plane(G1 and H1) < hardway plane(R2 and G2) < grain plane(R1 and H2). In particular, the intersection angles for three rock cleavages and three planes are in order of rift and rift plane < hardway and hardway plane < grain and grain plane. Consequently, the two diagrams of rift(R1 and R2) and rift plane(G1 and H1) show higher frequency of the point of contact and intersection. These characteristics of change were derived through the general chart for three planes and three rock cleavages. Lastly, the correlation analysis through the values of parameters along with the distribution pattern is useful for discriminating three quarrying planes.

Optimization of Tube Voltage according to Patient's Body Type during Limb examination in Digital X-ray Equipment (디지털 엑스선 장비의 사지 검사 시 환자 체형에 따른 관전압 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.379-385
    • /
    • 2017
  • This study identifies the optimal tube voltages depending on the changes in the patient's body type for limb tests using a digital radiography (DR) system. For the upper-limp test, the dose area product (DAP) was fixed at $5.06dGy{\ast} cm^2$, and for the lower-limb test, the DAP was fixed at $5.04dGy{\ast} cm^2$. Afterwards, the tube voltage was changed to four different stages and the images were taken three times at each stage. The thickness of the limbs was increased by 10 mm to 30 mm to change in the patient's body type. For a quantitative evaluation, Image J was used to calculate the contrast to noise ratio (CNR) and signal to noise ratio (SNR) among the four groups, according to the tube voltage. For statistical testing, the statistically significant differences were analyzed through the Kruskal-Wallis test at a 95% confidence level. For the qualitative analysis of the images, the pre-determined items were evaluated based on a 5-point Likert scale. In both upper-limb and lower-limb tests, the more the tube voltage increased, the more the CNR and SNR of the images decreased. The test on the changes depending on the patient's body shape showed that the more the thickness increased, the more the CNR and SNR decreased. In the qualitative evaluation on the upper limbs, the more the tube voltage increased, the more score increased to 4.6 at the maximum of 55kV and 3.6 at 40kV, respectively. The mean score for the lower limbs was 4.4, regardless of the tube voltage. The more either the upper or lower limbs got thicker, the more the score generally decreased. The score of the upper limps sharply dropped at 40kV, whereas that of the lower limps sharply dropped at 50kV. For patients with a standard thickness, the optimized images can be obtained when taken at 45kV for the upper limbs, and at 50kV for the lower limbs. However, when the thickness of the patient's limbs increases, it is best to set the tube voltage at 50 kV for the upper limbs and at 55 kV for the lower limbs.

A Study On the Operating Room Nurses' Performances of Duties and Their Fatigue (수술실간호사의 직무수행과 피로에 관한 연구)

  • Park, Jeong Sook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.6 no.2
    • /
    • pp.110-127
    • /
    • 1997
  • The aim of this study is to present the basic datum for the promotion of effectiveness and improvement of nursery tasks, by grasping the situation of operating room nurses tasks and the degree of their fatigue. For these researches, 70 nurses out of the operating rooms of 3 university-affiliated hospitals-two in Seoul and one in Pusan, were chosen at random by a non-probability sampling method. These researches were done from April 14 to April 26 in 1997 by questionairing method. The questionaire was composed of 30 items, which asks the examinees of their physical, mental, and neurosensory symptoms, with 10 items respectively. The reliability of the research instrument was turned out very high with Cronbach's ${\alpha}=.9376$. The datum were electronically processed using Statistics Program for Social Sciences(SPSS). The analysis of datum in this study has a general character, in which the demosociological character and the special ex-officio character was calculated by frequency and percentage. The situation of tasks in operating rooms was calculated by frequency and percentage. The fatigue of operating room nurses was calculated by average and standard deviation. To compare the fatigue with regard to the character of operating room nurse's tasks, t-test and F-test(ANOVA) were used after the character of variations, and the variations at the level of P<.05 which might have some meaning was verified after the fact with Duncan's Multiple Range(DMR). The results of this research are as follows : 1) The nurses working in operating rooms show their fatigue in three fields-in Group I physical symptoms 3.28, in Group III neurosensory symptoms 2.85, and in Group II mental symptoms 2.73, which shows I Dominant type (general type). 2) They complain, in Group I they are "feeling the heavy legs," 3.28 and in Group II they "occasionally forget soon what to do," 3.09. and in Group III, they "feel lumbago," 3.47, which is the highest rate of the three. The highest rate results from the character of their tasks, in which they have to move rapidly the heavy appliances and do their jobs standing many hours, especially wearing heavy radiation protector. 3) As to transportation, subway using group feel the greatest fatigue, 3.18(F=4.315, P=.008). 4) As to department, nurses in the orthopedic's surgery part feel the greatest fatigue, 3.26(F=2.040, P=.050). 5) As to the change of physical symptoms, the group answering that they found physical abnormality after working in operating rooms show the greatest fatigue, 3.12(t=-3.13, P=.003). 6) At to the general circumstances, the group answering that they receive insufficient consideration on their physical abnormality in their department, show the greatest fatigue, 3.10(F=3.200, P=0.47). 7) As to the relation with superior officers, the group answering that their superior officer has an impetuous temperament, show great fatigue, 3.11(F=4.855, P=.011). 8) As to the time of feeling fatigue, the fatigue reaches the highest point 1~2 hours after operations, 3.04(F=2.703, P=.046). 9) When they feel fatigue after scrub nurse duties, they feel the greatest fatigue 2 hours after the duties, 3.09( F=2.841, P=.038). 10) As to the operation instruments, when they use complex instruments borrowing from the outside in addition to the basic instruments, their fatigue becomes the greatest, 3.09(F=7.831, P=.000). 11) As to the kind of operation, when they participate in orthopedic's surgery operations, they feel the greatest fatigue, 3.18(F=4.362, P=.000). With the above results, it is proved that the degree of operating room nurses' fatigue is considerably high. So it may be concluded that the measure for lessening the fatigue should be find immediately, not on the level of personal matters but on the level of hospital nursing administration.

  • PDF

A Study on the Changes of Gender Identity Found in the Character of Elsa on Frozen -Focus on Queer Theory- (겨울왕국의 엘사 캐릭터에 나타난 젠더 정체성의 변화 -퀴어이론을 중심으로-)

  • Lee, Jun-Soo
    • Cartoon and Animation Studies
    • /
    • s.38
    • /
    • pp.1-28
    • /
    • 2015
  • The work appeared a featured female character in the Disney animation film begins with 'Snow White' released in 1937. After then, the 11 female characters appeared included 'Tangled' in 2010. Female characters reveal their identity due to obedient, family-oriented and marriage with prince and then gradually develop to heroine who leads to man, and is independent, pioneering, and sometimes saves the nation. Nevertheless, the ending of the Disney animation was still not escape the institutional, traditional discourse. Female characters are followed to meet the featured actor kissing and marriage, or was to show the virtues of sacrifice for the actor. However, Elsa in 'Frozen' is the character with an independent identity compared with the patriarchy, male chauvinism and heterosexual dichotomous discourse given so far in Disney. In this study, it is to explain the change of gender identity in the character of Elsa through Queer theory that deconstructs the distinction between sex and gender, and is constituted by the actions typed and performed the gender concept, and is dismantling the dichotomy itself such as male/female, heterosexual/homosexual. The performative of Queer make the boundaries between lesbian-gay, sexuality and heterosexual ambiguous. It can be said that the performative has political nature resisted to the dominant discourse through these parodiable strategy. The performative showed of Elsa is in the boundaries between the sisterhood and the heterosexual. When analyzed in a heterosexual perspective Elsa's identity is to be understood as simply just love the intimacy of a sister and a sister. On the other hand, if you focused on the relationship between women and the relationship between Elsa and Anna is recognized as the point of view of homosexuality. Because if you look at the concept of lesbian continuum, the homosexual love in the female characters of Disney seems like a bond between women, easier than heterosexual love can be hidden sexual desires. Elsa has developed into a performative identity through the expression of performative and the inhibitory of queer identity. And then the her sorcery that was initially contraindicated and the presence of a fear became to the 'lesbian phallus'. The sorcery that can be seen the signifying phallus against to the privileges of heterosexual patriarchy is recognized in the world of Arendal. Elsa is a new women featuring Disney characters. as this character is analysised by Queer theory, this study seeks to expand the area of the various character analysis methods.

Learning Curve of a Laparoscopy Assisted Distal Gastrectomy for a Surgeon Expert in Performing a Conventional Open Gastrectomy (개복 위절제술에 경험이 풍부한 술자에 의한 복강경 보조하 원위부 위절제술의 Learning Curve)

  • Kim, Ji-Hoon;Jung, Young-Soo;Jung, Oh;Lim, Jeong-Taek;Yook, Jeong-Hwan;Oh, Sung-Tae;Park, Kun-Choon;Kim, Byung-Sik
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.167-172
    • /
    • 2006
  • Purpose: The laparoscopy assisted gastrectomy has been increasingly reported as the treatment of choice for early gastric cancer. However, expert surgeons, who have performed a conventional open gastrectomy for a long time, tend to have a negative attitude toward laparoscopic procedures. The aim of this study was to determine the learning curve of a laparoscopy assisted distal gastrectomy (LADG) for a surgeon expert in performing an open gastrectomy and to analyze the factors that have an effect on a LADG. Materials and Methods: Between April 2005 and March 2006, 62 patients underwent a LADG with D1+beta lymph-node dissection. The 62 patients were divided into 10 sequential groups with 6 cases in each group (the last group was 8 cases), and the time required to reach the plateau of the learning curve was determined by examining the average operative times of these 10 groups. Other factors, such as sex, BMI, complications, transfusion requirements, the number of retrieved lymph nodes, and change of postoperative hemoglobin level, were also analyzed. Results: With the $5^{th}$ group (after 30 cases), the operative time reached a plateau (average: 170 min/operation). The differences between before the $30^{th}$ case and after the $31^{st}$ case with respect to changes in the postoperative hemoglobin level, the number of retrieved lymph nodes, the transfusion requirements, and the complications rate were not significant. Conclusion: According to an analysis of the operative time, experience with 30 LADGs in patients with early gastric cancer is the point at which the plateau of the learning curve (7 months) is reached. Abundant experience with a conventional open gastrectomy and a well-organized laparoscopic surgery team are important factors in overcoming the learning curie earlier.

  • PDF

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.