• Title/Summary/Keyword: Chamber width

Search Result 158, Processing Time 0.026 seconds

Development and Applications of Material Testers for the Thin Films (박막 재료 시험기 개발 및 응용)

  • Ahn Hyun-Gyun;Lee Hak-Joo;Oh Chung-Seog
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.163-170
    • /
    • 2006
  • Thin films play an important role in many technological applications including microelectronic devices, magnetic storage media, MEMS and surface coatings. It is well known that a thin film's material properties can be very different front the corresponding bulk properties and thus there has been a strong need for the development of a miniature tester to measure the mechanical properties of a thin film. Two testers are designed and set up in small size of 62 mm width, 20 mm depth and 90-120 mm height to fit in a chamber of scanning electron microscope (SEM). One tester has a homemade 0.2 N load cell and a low-priced electromagnetic actuator. The other has a commercial 5 N load cell, a $52{\mu}m$ piezoelectric actuator and some novel grips. Two types of 3.5 microns thick polysilicon specimen are tested to prove the testers' applicability. The strain is measured by the two ways. Firstly, it is measured by an ISDG system in the atmosphere far the reference. Secondly, the same test is repeated in a SEM chamber to monitor the strain as an in-situ experiment. The strain is evaluated by observing the gap change between two markers.

On an Analysis of Reflection Coefficients by a Partially Immersed Slotted Plate with a Back Wall (직립벽 앞에 놓인 일정깊이 잠긴 슬릿판에 의한 반사율 해석)

  • 조일형
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.3
    • /
    • pp.143-150
    • /
    • 2003
  • Based on the eigenfunction expansion method, the interaction between monochromatic waves and a partially immersed slotted plate with a back wall has been investigated. Analytical results show that the reflection coefficients by a partially immersed slotted plate depend on the porosity, immersed depth, chamber width, incidence angle and wave frequency. It is found that the reflection coefficient has minimum value within entire frequency range when the porosity has optimal value 0.1. Comparison between the analytical results and the experimental results(Zhu,2001) of reflection coefficients is made for various chamber widths, immersed depths and wave periods with good agreement. The present analytic method can account adequately for energy dissipation caused by flow separation behind a slotted plate and provide the design informations for the construction of slit caisson breakwater.

A Study About PDMS-Glass Based Thermopneumatic Micropump Integrated with Check Valve (체크밸브가 달린 열공압 방식의 PDMS-유리마이크로 펌프에 관한 연구)

  • Ko, Young-June;Cho, Woong;Ahn, Yoo-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.720-727
    • /
    • 2008
  • Microfluidic single chip integrating thermopneumatic micropump and micro check valve are developed. The micropump and micorvalve are made of biocompatible materials, glass and PDMS, so as to be applicable to the biochip. By using the passive-type check valve, backward flow and fluid leakage are blocked and flow control is stable and precise. The chip is composed of three PDMS layers and a glass substrate. In the chip, flow channel and pump chamber were made on the PDMS layers by the replica molding technique and pump heater was made on the glass substrate by Cr/Au deposition. Diameter of the pump chamber is 7 mm and the width and depth of the channel are 200 and $180{\mu}m$, respectively. The PDMS layers chip and the heater deposited glass chip are combined by a jig and a clamp for pumping operation, and they are separable so that PDMS chip is used as a disposable but the heater chip is able to be used repeatedly. Pumping performance was simulated by CFD software and investigated experimentally. The performance was the best when the duty ratio of the applied voltage to the heater was 33%.

The Study of Fire Detector Circuit with Wireless Communication (무선통신기능을 갖는 화재감지기 회로에 대한 연구)

  • Baek, Dong-Hyun;Kim, Jang-Won
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.111-115
    • /
    • 2010
  • For the development of fire detector equipments that was fused independent type of fire detector and a wireless communication function, this paper adopted a signal processing method of an independent formation fire sensor by a ZigBee communication method, and it was designed that the combinations of fire detector and wireless communications network were enabled. When a fire occurred, output voltage of a fire detector was 0.4 V, the movement pulse width was $600{\mu}s$, and that was confirmed by an experiment. When it has lookout state, LED worked by 30 s cycle and working current is 0.12 mA. When a fire occurred, LED worked by 0.5 s cycle and working current was 7 mA, and through this experiment of power source, Chamber tester, smoke tester,IRED, LED lighting, the propriety of the method that we showed in this paper confirmed.

The Effects of CO2 Enrichment on the Radial Growth of Pinus densiflora

  • En-Bi CHOI;Hyemin LIM;Jeong-Wook SEO
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.3
    • /
    • pp.289-299
    • /
    • 2024
  • The current study aimed to investigate the impact of CO2 enrichment on the width of annual tree rings, earlywood and latewood, and the area of annual growth of Pinus densiflora Siebold & Zucc. grown in open-top chamber (OTC). To this end, two CO2 enrichment cases were considered, namely 1.4 × increment (560 ppm in OTC-II) and 1.8 × (720 ppm in OTC-III) were compared with the current atmosphere (400 ppm in OTC-I). The CO2 enrichment conditions for a period of 12 years (2010-2021) were considered, and all measurements were done through image analysis. The study showed that the increment in CO2 concentrations positively affected the tree growth. The measurement data from the trees in OTC-III were considerably higher than those from OTC-I, whereas those from OTC-II were slightly higher than those from OTC-I. Decreasing patterns of the measured widths and area in 6-7 years after the beginning of CO2 enrichment was found for all the OTCs. These patterns were possibly due to changes in the physiological features, such as aging. The findings of the present study can have potential uses as fundamental data for forest management considering CO2 concentrations.

Novel Fabrication and Testing of a Bubble-Powered Micropump (새로운 기포동력 마이크로펌프 제작 및 실험)

  • Jung, Jung-Yeul;Kwak, Ho-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1196-1200
    • /
    • 2004
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. In this study, a bubble-powered micropump was fabricated and tested. The micropump consists of two-parallel micro line heaters, a pair of nozzle-diffuser flow controller and a 1 mm in diameter, 400 ${\mu}m$ in depth pumping chamber. The two-parallel micro line heaters with 20 ${\mu}m-width$ and 200 ${\mu}m-length$ were fabricated to be embedded in the silicon dioxide layer of a wafer which serves as a base plate for the micropump. The pumping chamber, the pair of nozzle-diffuser unit and microchannels including the liquid inlet and outlet port were fabricated by etching through another silicon wafer. A glass wafer (thickness of $525{\pm}15$ ${\mu}m$) having two holes of inlet and outlet ports of liquid serve as upper plate of the pump. Finally the silicon wafer of the base plate, the silicon wafer of pumping chamber and the glass wafer were aligned and bonded (Si-Si bonding and anodic bonding). A sequential photograph of bubble nucleation, growth and collapse was visualized by CCD camera. Clearly liquid flow through the nozzle during the period of bubble growth and slight back flow of liquid at the end of collapsing period can be seen. The mass flow rate was found to be dependent on the duty ratio and the operation frequency. As duty ratio increases, flow rate decreases gradually when the duty ratio exceeds 60%. Also as the operation frequency increases, the flow rate of the micropump decreases slightly.

  • PDF

Design of an Antenna Using Four-wires for EMI/EMC Experiment (EMI/EMC 실험을 위한 Four-wires을 이용한 안테나 설계)

  • Gang, Sung-Won;Kim, Jun-Kyu;So, Jun-Ho;Chung, Young-Seek;Cheon, Chang-Yul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.6 s.121
    • /
    • pp.612-619
    • /
    • 2007
  • In this paper, a Four-wired antenna was designed and manufactured using Four-wires in order to perform EMI/EMC experiments. As compared with a TEM cell, the feature of the Four-wired antenna has simple installment with broadband balun, a Four-wired antenna, and loading resistances in an anechoic chamber. And the E-field polarization of antenna can be easily changed. Without the limitation of space, EMI/EMC experimental environment could be built within the anechoic chamber with the moderate cost. In S, C, and X-bands, the manufactured antenna was able to make an experiment on EMI/EMC with the DUT which has the quiet zone of the height, width, length equal to about 10 cm.

YBCO coated conductor with a single buffer layer of Yttrium Oxide

  • Park, Chan;Dongqi Shi;Kyujeong Song;Rokkil Ko;Park, Soojeong;Yoo, Sang-Im
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.20-22
    • /
    • 2003
  • Y$_2$O$_3$ films were pulsed laser deposited on cube textured Ni and Ni-W substrates to be used as a single buffer layer of YBCO coated conductor. Initial deposition of $Y_2$O$_3$ films was performed in a reducing atmosphere, and subsequent deposition was done in the base pressure of the chamber and oxygen atmosphere. The $Y_2$O$_3$ films have a strong cube texture (The full width at half maximum of the ø-scan of $Y_2$O$_3$ was 8.4 which was the same as that of metal substrate) and smooth crack-free microstructure. The biaxially textured YBCO films (The full width at half maximum of the ø-scan was 10.2) pulsed laser deposited on the $Y_2$O$_3$/metal exhibited Tc(R=0) of 86.5K and Jc of 0.7 MA/cm2 at 77K in self field, representing that the $Y_2$O$_3$ single buffer layer is an efficient diffusion barrier of Ni and thus very promising for the achievement of high-Jc YBCO coated conductor.

Effect of High Injection Pressure and Ambient Pressure on the DME Spray Characteristics Injected Through a Common-rail Diesel Injector (커먼레일 디젤 인젝터에서 연료 분사 및 분위기 압력이 DME 분무 특성에 미치는 영향)

  • Kim, Hyung-Jun;Park, Su-Han;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.14 no.2
    • /
    • pp.71-76
    • /
    • 2009
  • The aim of this investigation is to study the effect of the high injection pressure on the dimethyl ether (DME) spray characteristics injected through a common-rail diesel injector under various ambient pressures. In order to investigate the effect of the injection pressure and ambient condition, the common-rail injection system with two high pressure pumps and high pressure chamber pressurized up to 40 bar were used, respectively. Spray images of DME fuel obtained from a visualization system composed of high speed camera and two metal halide lamps as the light source. From the obtained images, the spray behaviors such as a spray development process, spray tip penetration, spray width, and spray cone angle were measured for analyzing the DME spray characteristics under various experimental conditions. It was found that the spray development slowed as the ambient pressure increased and spray tip penetration at injection pressure of 90 MPa is longer than that at 50 MPa. In addition, the spray width at the end stage of injection decreased under the atmospheric conditions due to the evaporation property of DME fuel, and DME spray shows narrow spray cone angle according to the injection pressure increased.

  • PDF

Conceptual Design Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine (풍력터빈 성능시험을 위한 풍동 개념연구)

  • Kang, Seung-Hee;Choi, Woo-Ram;Kim, Hae-Jeong;Kim, Yong-Hwi
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.431-434
    • /
    • 2009
  • Conceptual study of an open-circuit type low-speed wind tunnel for test of wind turbine blade is conducted. The tunnel is constituted of a settling chamber, a contraction, closed and open test sections, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The open test section with dimension width of 1.8 m, height of 1.8 m and length of 4.14 m is adopted for aeroacoustic test. The contraction ratio is 9 to 1 and maximum speed in the closed test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine.

  • PDF