• Title/Summary/Keyword: Chamber size

Search Result 696, Processing Time 0.026 seconds

Characterization of Particle Size Distribution of Infiltrated Secondhand Smoke through the Gap in a Single Glazed and a Secondary Glazed Window by Indoor and Outdoor Pressure Differences (실내외 압력 차에 따른 단창과 이중창의 틈새로 침투된 간접흡연의 입자 크기 분포 특성)

  • Kim, Jeonghoon;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.360-369
    • /
    • 2018
  • Objectives: Outdoor tobacco smoke can penetrate into the indoor environment through cracks in the building envelope. This study aimed to characterize the particle size distribution of infiltrated secondhand smoke (SHS) through the gap in a single glazed and a secondary glazed window according to pressure differences in a chamber. Methods: Two polyvinyl chloride sliding windows were evaluated for infiltration, one with a glazed window and the other with a secondary glazed window. Each window was mounted and sealed in a polycarbonate chamber. The air in the chamber was discharged to the outside to establish pressure differences in the chamber (${\Delta}P$). Outdoor smoking sources were simulated at a one-meter distance from the window side of the chamber. The particle size distribution of the infiltrated SHS was measured in the chamber using a portable aerosol spectrometer. The particle size distribution of SHS inside the chamber was normalized by the outdoor peak for fine particles. Results: The particle size distribution of SHS inside the chamber was similar regardless of window type and ${\Delta}P$. It peaked at $0.2-0.3{\mu}m$. Increases in particulate matter (PM) concentrations from SHS infiltration were higher with the glazed window than with the secondary glazed window. PM concentrations of less than $1{\mu}m$ increased as ${\Delta}P$ was increased inside the chamber. Conclusions: The majority of infiltrated SHS particles through window gap was $0.2-0.3{\mu}m$ in size. Outdoor SHS particles infiltrated more with a glazed window than with a secondary glazed window. Particle sizes of less than $1{\mu}m$ were associated with ${\Delta}P$. These findings can be a reference for further research on the measurement of infiltrated SHS in buildings.

Combustion Characteristics in Small Combustion Chamber Size about Quenching Distance (소염 거리에 근접하는 소형 연소실 환경에서의 연소특성)

  • Lee, Dae-Hoon;Choi, Kwon-Hyoung;Kwon, Se-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.2
    • /
    • pp.63-68
    • /
    • 2000
  • Combustion phenomenon in scale-downed combustor is investigated. As the combustor scale decreases surface to volume ratio increases and chamber size approaches quenching distance. As the combustor scales down surface to volume ratio increases resulting increased heat loss. And this heat loss can affect quenching and instability of the flame. To investigate this effect plastic mini combustor is made. Stoichiometricaly premixed Hydrogen / air gas is used as fuel. Initial chamber pressure and chamber size are varied and the effects are evaluated. Peak pressure decreased with the decrease in chamber height. As initial chamber pressure decreases peak pressure decreases and this change is more important than scale down effect till the chamber height of 1mm. With this result and further information following the experiments design parameter for micro engine can be established.

  • PDF

Size Control of Bismuth Nanoparticles by Changes in Carrier-Gas Flow Rate and Chamber Pressure of Gas Condensation Apparatus (가스응축장치 캐리어가스 공급속도 및 압력변화를 통한 비스무스 나노분말 입도제어)

  • Lee, Gyoung-Ja;Kim, Chang-Kyu;Lee, Min-Ku;Rhee, Chang-Kyu
    • Journal of Powder Materials
    • /
    • v.17 no.5
    • /
    • pp.379-384
    • /
    • 2010
  • In the present work, bismuth nanopowders with various particle size distributions were synthesized by controlling argon (Ar) gas flow rate and chamber pressure of a gas condensation (GC) apparatus. From the analyses of transmission electron microscopy (TEM) images and nitrogen gas adsorption results, it was found that as Ar gas flow rate increased, the specific surface area of bismuth increased and the average particles size decreased. On the other hand, as the chamber pressure increased, the specific surface area of bismuth decreased and the average particles size increased. The optimum gas flow rate and chamber pressure for the maximized electrochemical active surface area were determined to be 8 L/min and 50 torr, respectively. The bismuth nanopowders synthesized at the above condition exhibit 13.47 $m^2g^{-1}$ of specific surface area and 45.6 nm of average particles diameter.

Effect of Internal Swirler Angle and Swirl Chamber Aspect Ratio of Nozzle on Spray Characteristics (노즐 내부 스월러각과 스월실 형상비 변화가 분무특성에 미치는 영향)

  • Kim, Y.J.;Jung, H.C.;Jung, J.W.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.8 no.4
    • /
    • pp.39-45
    • /
    • 2003
  • The Objective of this study is to investigate the effect of internal swiller angle and swirl chamber aspect ratio of nozzle on spray characteristics for application of spray system in micro fabrication process. The macro-spray characterictics such as the spray angle and breakup process were obtained by photographs illustrating atomization. The micro-spray characteristics such as droplet size and axial velocity were measured by using PDA with swirler angle and swirl chamber aspect ratio. The swiller angles were $13.5^{\circ},\;27^{\circ},\;and\;40.5^{\circ}$. The swirl chamber aspect ratios were 1.2, 1.6, and 2.0. It was found that the smaller swirl chamber aspect ratio was, the larger axial velocity and drop size were.

  • PDF

Analysis of Impingement Lands to Help Diesel Combustion Chamber Using Spray Impaction (분무충돌을 이용하는 디젤연소실 설계를 위한 충돌면 분석)

  • Park, K.
    • Journal of ILASS-Korea
    • /
    • v.1 no.2
    • /
    • pp.24-32
    • /
    • 1996
  • Most of the research of small engines to date focused on developing spark ignition engines occupied much parts. Recently the number of a small direct injection diesel engine applied in small cars has been increased and considered as a next generation power source for passenger cars because of its high efficiency. Therefore the combustion chamber becomes smaller and the fuel injection pressure goes higher, which makes fuel sprays impinged easily on the combustion chamber walls. When strong swirls are not induced, the fuel may not mix with air because of fuel deposition on the wall. As a positive way, the combustion chamber systems which is using spray wall impaction has been introduced and assessed by an experimental or a simulate manner. In these systems the raised lands are positioned in tile chamber for spray impaction in order to break up the fuel drops into much smaller and direct them into desirable direction. This study addresses to the effects of rho position and size of the raised land or glow plug to help the chamber design using spray wall impaction. The characteristics of the spray impinged on various lands are investigated and compared with each other. Then the chamber shapes are discussed with the characteristics and their proper position and size is proposed in any chamber volume.

  • PDF

Determination of Egg Freshness and Internal Quality Measurement Using Image Analysis (계란의 신선도 결정과 영상분석을 이용한 내부품질 측정)

  • Kim, Hyeon-T.;Ko, Han-J.;Kim, Ki-Y.;Kato, K.;Kita, Y.;Nishizu, T.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.166-172
    • /
    • 2007
  • Egg quality indices are related with freshness, size of air chamber, loss of weight, and viscosity of the yolk and the protein. However, since the described quality parameters require measured in a destructive way, it is not suitable to inspect the egg quality with complete enumeration. Therefore, this study was performed to investigate the potential of image analysis method for evaluation of internal egg quality. Samples of 90 fresh eggs were collected immediately after laying and stored up to 24 days. Five eggs were randomly drawn from each storage condition (packing vs unpacking) at a regular interval and loss of weight, specific gravity and size of air chamber were measured. The image analysis for nondestructive measurement of size of air chamber was also studied. Results showed that the egg weight and gravity gradually decreased with increasing of storage days, while the size of air chamber linear increased caused by evaporation of water through the shell. A relationship a between conventional method and the image analysis method for measuring the size of air chamber was developed with the correlation coefficient of 0.928. The new finding implied that image analysis might provide a useful nondestructive tool to assess internal egg quality.

The Evaluation of Multiplane-Parallel Chamber Using Crystal Plate as Ionization Medium for Therapeutic Radiation Beams

  • Young W. Vahc;Park, Kyung R.;Kim, Sookil;Chul W. Joh;Kim, Tae H.
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 1998
  • There has been necessity of an air free ionization chamber using the gold-crystal-aluminium plates, henceforth called the crystal chamber. The crystal chamber formed of parallel plates is very small in size and has more response for absorbed dose of therapeutic radiation beams. The gold plate on the crystal facing the photon and electron beam acts as an intensifier of signals and crystal plate as an ionization medium respectively. Both the copper guard ring and the aluminum collecting electrode are connected to an electrometer. Using high energy photon (6, 15 MV) and electron (9, 12, 15, 18 MeV) beams, the responses of the crystal chamber are evaluated against a PTW Farmer-type chamber at a field size of 10${\times}$10cm$^2$ and 100 cm SSD. The responses of crystal chamber for therapeutic radiation electron and photon beams are greater in magnitude by several order than Farmer. The crystal chamber has good linearity without correction factor C$\_$t,p/ with respect to the signals, a reading reproduction with good accuracy and precision less than 0.5%, and has other useful functions in measuring radiation beams.

  • PDF

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

The Size Analysis of Raised Lands Prepared for Spray Impaction in OSKA Typed D.I. Diesel Engine Combustion Chamber (OSKA형 디젤기관 연소실의 충돌면 크기 분석)

  • 김재휘;홍영표;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.82-90
    • /
    • 1996
  • In a diesel engine the phenomenon of spray impaction on a chamber wall has been taken as an undesirable matter because of the deposition of fuel on the surfaces, and the subsequent slow evaporation and mixing with air resulting in unburned hydrocarbons. Therefore many researches have concentrated on avoiding fuel impingement on surfaces. On the contrary done a number of studies using spray wall impactions in a positive way, which makes the droplets smaller, changes the direction into free spaces far from the wall and also improves mixing with air. In this paper the size of the impaction site prepared for the injection spray which is raised from the bottom in the piston bowl center is analysed as both simulative and experimental manner.

  • PDF

Effects on Diesel Spray for Variation of Ambient Pressure and Impingement Land Position (주위 압력 및 충돌면 위치 변화가 디젤분무에 미치는 영향)

  • 박대순;김문헌;박권하
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.95-105
    • /
    • 1997
  • A diesel engine has become smaller and higher, thus sprays injected in high speed may be impinged on a small combustion chamber wall if there is not enough strong swirl. Those combustion chambers should have proper measures to avoid the spray impinged and deposited on a wall. One of the measures is a chamber prepared impingement parts raised on a chamber wall surface. In this system a spray is injected into the raised pip, broken into a number of smaller drops and spreaded out away from the wall surface. Therefore the fuel droplets distributes over inside of the combustion chamber. In this study, the positions, sizes and angles of the raised land are discussed to help the chamber design using spray wall impaction. The characteristics of the spray impinged on various lands are investigated and compared with each other. Then chamber shapes are discussed with the spray characteristics and the proper positions and size are proposed in some chamber volumes.

  • PDF