• 제목/요약/키워드: Chamber Monitoring

검색결과 188건 처리시간 0.027초

이온선택성 미소전극을 이용한 암모니아성 질소 및 질산성 질소의 연속 농도 측정 (Continuous Measurement of Ammonium-nitrogen and Nitrate-nitrogen using a Ion-Selective Microelectrode)

  • 임미지;선지윤;박정진;변임규;박태주;이태호
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.718-724
    • /
    • 2008
  • The ion selective microelectrode (ISME) has been used for measuring the ion profile of DO, $NH_4{^+}-N$, $NO_2{^-}-N$ and $NO_3{^-}-N$ in biofilm. In this study we evaluated the detection limit and validity of ISME and applied ISME for the continuous measurement of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration in the modified Ludzack-Ettinger (MLE) process. Average detection limits of $NH_4{^+}-N$ and $NO_3{^-}-N$ ISME were $10^{-4.44}M$ and $10^{-4.62}M$, respectively. Since the ISME with $5{\sim}10{\mu}m$ of tip diameter showed a faster response time than that of $1{\sim}5{\mu}m$, the ISME with a tip diameter of $5{\sim}10{\mu}m$ was fabricated and used to make real-time ion detections. Direct monitoring of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentrations in the aerobic (2) tank causes the instability of the electromotive force (EMF) for the initial 5~8 hours and also causes remarkable error values of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration. This phenomenon is caused by aeration and mixing in the reactor. Thus, the measuring chamber was newly designed for the aerobic (2) tank and then the EMF of the ISME were stabilized in less than 1 hour. Errors of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration were decreased after stabilization of the EMF. The ISME analysis were well corresponded to the results of auto analyzer and ion chromatography. Consequently, the concentration of $NH_4{^+}-N$ and $NO_3{^-}-N$ could be continuously measured for 178 hours by the ISME.

참메기, Silurus asotus의 수온과 광주기 변화에 따른 산소 소비량 (Oxygen Consumption of Far Eastern Catfish, Silurus asotus, on the Different Water Temperatures and Photoperiods)

  • 조재윤;김유희
    • 한국수산과학회지
    • /
    • 제32권1호
    • /
    • pp.56-61
    • /
    • 1999
  • 참메기, Silurus asotus를 대상으로 수온 ($15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C$$30^{\circ}C$)과 광주기 (24L:0D, 12L:12D 및 0L:24D)에 따른 산소 소비량의 변화를 연속적인 컴퓨터 모니터링 시스템을 이용하여 조사하였다. 평균 무게 280g의 참메기의 산소 소비량은 수온의 증가에 따라 증가하였고, $15^{\circ}C$에서 $35.2\~96.4mg\;O_2/kg$ fish/hr, $20^{\circ}C$에서$78.6\~127.9mg\;O_2/kg$ fish/hr, $25^{\circ}C$에서$120.1\~231.7mg\;O_2/kg$ fish/hr, $30^{\circ}C$에서 $197.5\~352.3mg\;O_2/kg$ fish/hr으로 나타났다(p<0.05). 광주기에 따른 산소 소비량은 암기 조건에서 보다 명기 조건에서 산소소비량이 더 높게 나타났다. 또한, 24L:0D와 12L:12D와 비교하여 0L:24D에서 평균 산소 소비량이 낮게 나타났다(p<0.05). 산소 소비량의 최대값과 최소값의 차이는 수온이 상승함에 따라 증가하였고, 12L:12D에서 가장 큰 것으로 나타났고, 새벽녁과 저녁 무렵에 산소 소비량의 급격한 변화를 나타내었다. 특히, 12L:12D의 조건에 두었을 때 명기와 암기에 대한 뚜렷한 반응을 보였다.

  • PDF

갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가 (Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients)

  • 임상무;우광선;정위섭;홍성운;김장휘;김기섭
    • 대한핵의학회지
    • /
    • 제29권1호
    • /
    • pp.54-60
    • /
    • 1995
  • 방사성 핵종의 체내 투여 또는 체내 오염에 의한 내부피폭 흡수선량 측정을 위하여 개발된 MIRD 씨스템을 이용하여 175mCi $^{131}I$ 치료를 받는 8명의 분화된 갑상선암의 주변림프절 전이 환자에서 전신, 위, 신장, 방광 및 골수 등의 흡수선랑을 측정하였다. 전리함 검출기와 자료저장 장치가 부착된 Eberline Smart 200 씨스템을 이용하여 전신 $^{131}I$의 시간 방사능 곡선을 얻었고, 선형 회귀분석을 하여 곡선하면적을 구한 값을 투여 방사능량(Ao)으로 나누어 체류시간($\tau$)으로 하였다. MIRDose2의 S값을 이용하여 전신흡수선량을 구하였으며 ICRP publication 53의 표준인 신장, 방광, 위의 체류시간을 이용하여, 이들 장기의 흡수선량을 구하였다. 전신 및 골수의 흡수선량은 22.4 및 25.4rad로 ICRP 최대허용선량보다 훨씬 낮았으며, 방광에 375.1, 위에 285.1rad로 심각한 증상을 초래할 정도의 선량은 아니었다. 분화된 갑상선암의 폐 및 뼈전이 환자에서 200mCi 이상 투여방사능량을 증가시킬 경우 이 방법으로 전신 및 골수 등의 흡수 선량을 평가하여 안전성을 확인할 수 있을 것으로 생각된다.

  • PDF

수소 가스 원격 모니터링을 위한 라만 라이다 시스템 개발 (Development of a Raman Lidar System for Remote Monitoring of Hydrogen Gas)

  • 최인영;백성훈;박락규;강희영;김진호;이나종
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.166-171
    • /
    • 2017
  • 수소 가스는 연소과정에서 오염물질의 배출이 없는 친환경 에너지원이다. 그러나 연소 및 폭발성이 매우 강해 매우 위험한 특징을 갖고 있다. 원자력 발전소의 중대 사고 발생시 핵연료의 산화 과정에서 다량의 수소 가스가 발생하며 원전 격납 건물의 2차 사고의 원인으로 작용함으로 원전의 안전을 확보하기 위하여 수소 가스의 검출 기술은 매우 중요하다. 본 논문은 수소 가스의 원격 계측을 위한 라만 라이다 시스템의 개발에 관한 것이다. 소형의 이동 가능한 라만 라이다 시스템을 설계 및 개발하였으며, 수소 가스의 농도를 정량적으로 계측하기 위한 계측 알고리즘을 개발하였다. 개발된 수소 가스 계측을 위한 라만 라이다 시스템의 수소 가스 검출 능력을 검증하기 위하여 수소 가스의 농도를 조절할 수 있는 가스 챔버를 이용하여 낮에 야외 환경에서 수소 가스 검출 실험을 실시하였다. 그 결과 20미터 거리에서 최소 0.67 Vol.%의 수소 가스 농도의 검출이 가능하였다.

Photosynthesis Monitoring of Rice using SPAR System to Respond to Climate Change

  • Hyeonsoo Jang;Wan-Gyu Sang;Yun-Ho Lee;Hui-woo Lee;Pyeong Shin;Dae-Uk Kim;Jin-Hui Ryu;Jong-Tag Youn
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2022년도 추계학술대회
    • /
    • pp.169-169
    • /
    • 2022
  • Over the past 100 years, the global average temperature has risen by 0.75 ℃. The Korean Peninsula has risen by 1.8 ℃, more than twice the global average. According to the RCP 8.5 scenario, the CO2 concentration in 2100 will be 940 ppm, about twice as high as current. The National Institute of Crop Science(NICS) is using the SPAR (Soil-Plant Atmosphere Research) facility that can precisely control the environment, such as temperature, humidity, and CO2. A Python-based colony photosynthesis algorithm has been developed, and the carbon and nitrogen absorption rate of rice is evaluated by setting climate change conditions. In this experiment, Oryza Sativa cv. Shindongjin were planted at the SPAR facility on June 10 and cultivated according to the standard cultivation method. The temperature and CO2 settings are high temperature and high CO2 (current temperature+4.7℃ temperature+4.7℃·CO2 800ppm), high temperature single condition (current temperature+4.7℃·CO2 400ppm) according to the RCP8.5 scenario, Current climate is set as (current temperature·CO2400ppm). For colony photosynthesis measurement, a LI-820 CO2 sensor was installed in each chamber for setting the CO2 concentration and for measuring photosynthesis, respectively. The colony photosynthetic rate in the booting stage was greatest in a high temperature and CO2 environment, and the higher the nitrogen fertilization level, the higher the colony photosynthetic rate tends to be. The amount of photosynthesis tended to decrease under high temperature. In the high temperature and high CO2 environment, seed yields, the number of an ear, and 1000 seed weights tended to decrease compared to the current climate. The number of an ear also decreased under the high temperature. But yield tended to increase a little bit under the high temperature and high CO2 condition than under the high temperature. In addition, In addition to this study, it seems necessary to comprehensively consider the relationship between colony photosynthetic ability, metabolite reaction, and rice yield according to climate change.

  • PDF

스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발 (Development of B4C Thin Films for Neutron Detection)

  • 임창휘;김종열;이수현;조상진;최영현;박종원;문명국
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.79-86
    • /
    • 2015
  • 헬륨-3는 높은 반응효율, 장시간 사용가능성, 감마선에 대한 낮은 반응확률 등과 같은 장점들을 가지고 있기 때문에 대부분의 중성자 검출기의 반응물질로 사용되어 왔다. 그러나 지난 몇 년 사이 전세계적인 헬륨-3의 부족으로 인해 기체의 수급이 어려워지고 있고 이에 따라 가격이 급격히 증가하게 되었다. 이러한 이유로 헬륨-3 대체 물질들을 이용한 고효율의 중성자 검출기의 개발에 대한 연구가 많은 연구그룹에 의해 활발히 진행되기 시작하였다. 이러한 연구에서는 다양한 물질들을 이용하고 있으며, 이 중에서 붕소-10은 다른 대체물질과 비교할 때 상대적으로 높은 중성자 반응확률, 낮은 감마반응효율, 물질의 안정성, 가격적 이점 그리고 기존 헬륨-3를 이용한 검출기의 계측회로의 재활용 가능성 등과 같은 장점들 때문에 많은 연구그룹에서 붕소-10을 이용한 중성자 검출기 개발을 진행하고 있다. 본 논문에서는 중성자 검출기에 사용될 수 있는 붕소-10 박막을 개발하고 이에 대한 성능평가를 수행하였다. 중성자 검출기의 반응물질로 붕소-10을 사용하기 위해서는 중성자와 붕소-10이 반응하여 생성되는 이차방사선을 측정할 수 있어야 한다. 본 연구에서 활용한 기체충진형 중성자 검출기의 경우 붕소-10을 얇은 박막 형태로 제작하여 중성자와 반응하여 생성된 이차방사선이 기체를 이온화 시켜서 생성되는 이온쌍을 측정하는 방법을 이용한다. 그러므로 중성자 반응효율과 이차방사선의 재흡수율을 고려한 붕소-10(탄화붕소)의 적절한 두께를 선정할 필요가 있다. 이를 위해서 본 논문에서는 몬테칼로 기법을 이용하는 MCNP6를 이용하여 다양한 두께에 따른 중성자신호수집효율의 변화를 계산하였다. 또한, 스퍼터링 기법을 이용하여 다양한 두께의 박막을 제작하고 이를 이용하여 중성자 반응신호를 측정하였다. 그리고 제작된 박막의 2차원 모니터링을 위한 다중선 비례계수기의 적용가능성을 타진하기 위해 제작된 붕소박막이 설치된 2차원 다중선 비례계수기를 제작하고 중성자 응답 특성을 평가하였다.

탄소나노튜브 가스센서의 SF6 분해생성물 검출 및 확산현상에 관한 연구 (Detection with a SWNT Gas Sensor and Diffusion of SF6 Decomposition Products by Corona Discharges)

  • 이종철;정세훈;백승현
    • 한국진공학회지
    • /
    • 제18권1호
    • /
    • pp.66-72
    • /
    • 2009
  • 가스절연개폐장치 (Gas-insulated switchgear, GIS)의 내부에는 절연에 관한 이상 여부를 감시하고 판단할 수 있는 시스템이 요구된다. 부분방전에 의해 발생되는 $SF_6$ 분해생성물에 관한 단일벽 탄소나노튜브 (Single-walled carbon nanotube, SWNT)가 지닌 우수한 검출기능 때문에 SWNT를 이용한 가스센서 개발이 활발히 진행되고 있다. 하지만 아직까지 부분방전에 의해 발생된 분해생성물의 확산현상에 관한 해석적 연구는 미흡한 실정이다. 본 논문에서는 실험 데이터 및 상용 CFD (Computational Fluid Dynamics) 프로그램을 이용하여 SWNT 가스센서에 포획되는 분해생성물의 코로나 방전에 의한 발생 과정과 챔버 내부에서의 확산과정을 모델링하여 부분방전 발생 시 챔버 내부의 온도, 압력, 그리고 분해생성물의 농도 등을 수치계산하였다. 분해생성물의 시간당 질량생성율과 발생온도는 각각 $5.04{\times}10^{-10}$ [g/s]와 773 K이라 가정하였다. 농도방정식을 계산함에 있어 미지의 확산계수를 임의의 값으로 가정하여 직접 부여하는 방법을 사용하지 않고, 확산계수를 정의하는데 사용되는 Schmidt수의 값을 지정하여 확산계수가 $SF_6$ 가스의 물성치인 점성계수와 밀도의 함수로 계산되도록 하였다. 수치결과로부터 분해생성물의 농도구배가 확산을 일으키는데 주요 구동포텐셜 (Drive potential)이 됨을 확인하였다. 센서 설치위치가 부분방전 발생영역에서 멀리 떨어질수록 분해생성물 농도가 낮음을 알 수 있었고, 부분방전이 지속될수록 분해생성물의 농도가 증가함을 확인하였다. 다수의 센서를 챔버 내부에 설치하면 각 센서의 응답시간을 확인하여 PD 발생위치를 판단할 수 있을 것이고, 이를 통해 GIS 진단 및 유지보수에 관한 유용한 정보로 사용될 수 있을 것이다.

호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증 (Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period)

  • 전수동;배선명;윤인하;강태영;백금문
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.137-147
    • /
    • 2014
  • 목 적 : 호흡연동 용적변조 회전방사선치료(Gated Volumetric Modulated Arc Therapy)에서 환자의 호흡주기 변화에 따른 선량전달의 정확성을 검증하고자 한다. 대상 및 방법 : 실험에는 TrueBeam STxTM(Varian Medical Systems, Palo Alto, CA)치료기를 사용하였다. 인체모형등가팬텀(Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA)의 전산화단층영상에 전산화치료계획시스템(Eclipse 10.0, Varian, USA)을 이용하여 10 MV FFF(Flatenning Filter Free), 선량률 1200 MU/min으로 1500 cGy/fx(Case1, 2, 3)과 220 cGy/fx(Case4, 5, 6)의 치료계획을 수립하였다. $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc)을 이용하여 1.5, 2.5, 3.5, 4.5 sec의 일정한 호흡주기와 평균호흡주기가 2.2, 3.5 sec인 환자의 호흡주기를 재현하였고 위상모드 30~70% 구간에서 방사선이 조사되도록 설정하였다. 각각의 호흡 조건에서 2차원 이온전리함 배열 검출기(I'mRT Matrixx, IBA Dosimetry, Germany)와 MultiCube Phantom(IBA Dosimetry, Germany)을 이용하여 측정하였고 세기변조 방사선치료 분석 프로그램(OmniPro I'mRT, IBA Dosimetry, Germany)을 이용하여 Gamma pass rate(3 mm, 3%)을 비교하였다. 결 과 : Case 1, 2, 3, 4, 5, 6의 Gamma pass rate은 일정한 호흡주기 1.5 sec에서 100.0, 97.6, 98.1, 96.3, 93.0, 94.8%, 2.5 sec에서 98.8, 99.5, 97.5, 99.5, 98.3, 99.6%, 3.5 sec에서 99.6, 96.6, 97.5, 99.2, 97.8, 99.1%, 4.5 sec에서 99.4, 96.3, 97.2, 99.0, 98.0, 99.3%의 결과를 보였다. 환자의 호흡을 재현한 경우 평균 호흡주기 2.2 sec에서는 97.7, 95.4, 96.2, 98.9, 96.2, 98.4%, 3.5 sec에서는 97.3, 97.5, 96.8, 100.0, 99.3 99.8%의 결과를 보였다. 결 론 : 2.5 sec이상의 일정한 호흡주기와 환자의 호흡을 재현한 실험에서 Gamma pass rate 95%이상의 임상적으로 신뢰할 만한 결과를 보였다. 일정한 호흡주기 1.5 sec의 Case 5, 6 에서 93.0, 94.8%의 결과를 보였으나 100명의 환자 호흡주기 분석 결과 1.5 sec의 호흡을 지속했던 경우는 없었던 점으로 보아 대부분의 호흡조건에서 정확한 선량전달이 가능함을 확인 하였다. 다만 극히 짧은 호흡주기로 인한 오차발생 가능성을 배제할 수 없기 때문에 치료전 선량전달 정확성 검증이 선행되어야 하며 모의치료시 환자 교육으로 안정된 호흡을 유지하고 정확한 모니터링을 통해 치료중 환자 호흡변화에 대처한다면 더욱 안정적이고 정확한 치료가 이루어질 것으로 사료된다.