• Title/Summary/Keyword: Cervical angle

Search Result 317, Processing Time 0.031 seconds

THE CORRELATION BETWEEN CRANIAL BASE SIZE, SHAPE AND HEAD POSTURE, AND THE POSITION OF MAXILLO-FACIAL STRUCTURES (두개저의 크기, 형태 및 두부자세와 악안면구조의 위치적 상관관계)

  • Hong, Yong-Seok;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.743-760
    • /
    • 1997
  • This study was done to evaluate the correlations between the size, the form of the cranial base, head posture and the horizontal and vertical position of craniofacial structures. For this purpose, 100 cephalometric radiographs were taken from the sample composed of 51 male and 49 female, 12 measurement criteria and 37 reference points were established and digitized, then calculation was performed for the values of measurement variables and the horizontal and vertical position of reference points. The correlations be4ween them were analyzed statistically and mean facial diagrams were constructed and compared with the selected groups which were composed of 10 Samples each as large and small group from the measurement value. The following results were obtained: 1. The angles n-s-ba and n-s-ar as variables for the ion of cranial base correlated highly to the horizontal and vertical position of reference points in the cervical column with statistical significance($0.1\%$ level). 2. The angles n-s-ba and n-s-ar as variables for the form of cranial base correlated to the horizontal position of the reference points in the facial structure with statistical significance($1\%$ level), but not to the vertical position of them($5\%$ level). 3. The length n-s, s-ba, and n-ar as variables for the size of cranial base were correlated th the position of craniofacial structures in various ways, but in general, highly correlated to the horizontal and vertical position of midfacial structures around the teeth and alveolar area. 4. the angle NSL/CVT and NSL/OPT as postural variables tot the inclination of cranial base and cervical column were correlated to the horizontal position of the craniofacial structures with statistical significance($1\%$ level), but not to the vortical position of them($5\%$ level). 5. The angle OPT/HOR and CVT/HOR as postural variables lot the inclination of cranial base and true horizontal line were not correlated to the horizontal and vertical position of the craniofacial structures with statistical significance($5\%$ level). 6. The correlation between the measurement variables and horizontal and vortical positions of the reference poits in soft tissue were shown as similar to the related hard tissue points.

  • PDF

Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer (자궁경부암 환자의 근접치료시 재현성 평가)

  • Kim Jong-Hwa;Son Jung-Hae;Jung Chil;Kim Mi-Hwa
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • I. Purpose Brachytherapy is the main component in treatment of patients with uterine cervical cancer. The reproducibility of applicator position in the same patient at repeated treatments was very important for accurate dose delivery. It was aimed to evaluate the change of applicator location between each high dose rate(HDR) brachytherapy insertion in the patients with uterine cervical cancer. II. Materials and Methods From January 1999 to October 2001, total 52 patients were treated with external beam radiotherapy and HDR brachytherapy (Microselectron, Nucletron). During six to seven times of brachytherapy, all patients had three treatment plans. From the orthogonal radiographs, we measured the following variables; height from upper border of pubic bone to os (HPO), distance from sacral promontory to tip of tandem (DST), distance from coccyx to os (DCO), distance from tip of right ovoid to os (DRO), distance from tip of left ovoid to os (DLO), and distance from center of the first tandem source to ovoid (DTO). To evaluate the reproducibility of applicator position, it was calculated the standard deviation of differences between three insertions for the 7 parameters in each patient. III. Results The ranges of standard deviations of interfractional differences for the variables were as follows. 1)HPO : $0{\sim}0.79cm$ 2)DST : $0{\sim}0.9cm$ 3)DCO : $0.06{\sim}0.76cm$ 4)DRO : $0{\sim}0.53cm$ 5)DLO : $0{\sim}0.45cm$ 6) DTO $0{\sim}0.36cm$ IV. Conclusions There was some change in applicator position on repeated implants in our study. But variation of the interfractional differences was minimal; in all parameters, there were less than 1 cm. We are continued to try for reducing the geometric variation between each procedure.

  • PDF

Effects of abutment angulation and type of connection on the fracture strength of zirconia abutments (지대주 각도와 연결방식이 지르코니아 지대주의 파절강도에 미치는 영향)

  • Kim, Ho-Seong;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the fracture strength of straight and angled zirconia abutments for internal hex and external hex implants. Materials and methods: Twenty internal hex implants and 20 external hex implants were prepared. The prefabricated straight zirconia abutments and 17-degree-angled zirconia abutments were connected to those 40 implants. The specimens were classified into 4 groups depending on the connection type and abutment angulation; internal hex implant/straight abutment, group INS; internal hex implant/angled abutment, group INA; external hex implant/straight abutment, group EXS; external hex implant/angled abutment, group EXA. All specimens were loaded at a 30-degree angle with a crosshead speed of 1 mm/min using universal testing machine. The fracture loads were analyzed using 2-way ANOVA and independent t-test (${\alpha}=.05$). Results: The mean fracture load for INS was 955.91 N, 933.65 N for INA, 1267.20 N for EXS, and 1405.93 N for EXA. External hex implant showed a significantly higher fracture load, as compared to internal hex implant (P < .001). No significant differences in fracture loads were observed between the straight and angled abutment in internal hex implants (P = .747) and external hex implants (P = .222). Internal hexes of abutments were fractured horizontally in internal connection implants, while lingual cervical neck portions were fractured in external connection implants. Conclusion: The zirconia abutments with external hex implants showed significantly higher fracture strength than those with internal hex implants. However there was no difference in fracture strength between the straight and 17-degree-angled zirconia abutment connected to both implant systems.

Craniospinal Neurenteric Cysts: Various MR Imaging Features (뇌척수 신경장관 낭종: 다양한 자기공명영상소견)

  • Jeon, Se-Jeong;Sohn, Chul-Ho;Kim, Eun-Hee;Son, Kyu-Ri;Park, Sung-Hye;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.54-62
    • /
    • 2009
  • Purpose : Craniospinal neurenteric (NE) cysts are rare developmental non-neoplastic cysts of the central nervous system with diverse MR imaging findings. The purpose of this study was to evaluate various MR imaging findings of intracranial and intraspinal NE cysts. Materials and Methods : We retrospectively reviewed the MR imaging findings of six NE cysts that were confirmed by pathology. We evaluated anatomic location, signal intensity, size and enhancement pattern of NE cysts. Results : Two intracranial lesions were located extra-axially in the cerebellopontine angle and quadrigeminal cisterns. Three spinal lesions were intraduralextramedullary cysts, located ventral to the spinal cord, but one thoracic lesion was an intramedullary cyst. The signal intensity of the cysts was hyperintense on T1-weighted images as compared with the cerebrospinal fluid (CSF) for two intracranial lesions and one cervical lesion. In addition, all intracranial lesions showed diffusion restriction. For the remaining three spinal lesions, the signal intensity was nearly the same as the signal intensity of the CSF as seen on both T1- and T2-weighted images. On contrast-enhanced studies, two intracranial cysts showed a small nodular enhancement and one thoracic spinal lesion showed rim enhancement. Conclusion : NE cysts have various locations, signal intensities, and possible focal nodular or rim enhancement. Therefore, NE cysts can be included in the differential diagnosis of various craniospinal cystic or tumorous cystic lesions.

  • PDF

Effects of Biofeedback Based Deep Neck Flexion Exercise on Neck Pain: Meta-analysis (바이오피드백을 이용한 심부목굽힘근운동이 목 질환에 미치는 영향: 메타분석)

  • Park, Joo-Hee;Jeon, Hye-Seon;Kim, Ji-hyun;Kim, Ye Jin;Moon, Gyeong Ah;Lim, One-bin
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Previous studies have reported that deep neck flexor (DNF) exercise can improve neck problems, including neck pain, forward head posture, and headache, by targeting the deep and superficial muscles of the neck. Despite the prevailing opinion across studies, the benefits of DNF can vary according to the type of neck problems and the outcome measures adopted, ranging from positive outcomes to non-significant benefits. A meta-analysis was conducted in this study to assess conclusive evidence of the impact of DNF exercise on individuals with neck problems. We used PUBMED, MEDLINE, NDSL, EMBASE, and Web of Science to search for primary studies and the key terms used in these searches were "forward head posture (FHP)," "biofeedback," "pressure biofeedback unit," "stabilizer," "headache," and "neck pain." Twenty-four eligible studies were included in this meta-analysis and were coded according to the type of neck problems and outcome measures described, such as pain, endurance, involvement of neck muscle, craniovertebral angle (CVA), neck disability index (NDI), cervical range of motion (CROM), radiographs of the neck, posture, strength, endurance, and headache disability index. The overall effect size of the DNF exercise was 0.489. The effect sizes of the neck problems were 0.556 (neck pain), -1.278 (FHP), 0.176 (headache), and 1.850 (mix). The effect sizes of outcome measures were 1.045 (pain), 0.966 (endurance), 0.894 (deep neck flexor), 0.608 (superficial neck flexor), 0.487 (CVA), 0.409 (NDI), and 0.252 (CROM). According to the results of this study, DNF exercise can effectively reduce neck pain. Thus, DNF exercise is highly recommend as an effective exercise method for individuals suffering from neck pain.

Evaluation of Cavity Wall Adaptation of Bulk-fill Resin Composites in Class II Cavities of Primary Molar (유구치 2급 와동에서 bulk-fill 복합레진의 와동적합성 평가)

  • Bae, Youngeun;Shin, Jonghyun;Kim, Shin;Jeong, Taesung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.446-454
    • /
    • 2017
  • Recently, there have been many studies on bulk-fill resin composites. However, studies on the proper materials for pediatric patients are rare. The aim of this study was to compare the cavity wall adaptation of bulk-fill resin composites with conventional resin composite in class II cavities of primary molars using microcomputed tomography (micro-CT). Standardized class II slot cavities were prepared in 80 exfoliated primary molars and randomly divided into 4 groups. The control group was restored with conventional resin composite, Filtek Z-350 XT (FZ), and the three groups were restored with bulk-fill resin composites, Filtek bulk-fill posterior (FB), Tetric N-Ceram Bulk Fill (TNC), Filtek bulk-fill flowable (FBF). All specimens were thermocycled and then immersed in 50% silver nitrate ($AgNO_3$) solution. Micro-CT was used to measure the penetration volume of the total silver nitrate and the degree of cervical marginal leakage and the number, size, and position of the voids were evaluated. The results revealed that the volume of silver nitrate were significantly different between FB and FZ (p < 0.05). The results also revealed that the penetration length of silver nitrate FBF showed statistically lower than the FZ and FB (p < 0.05). There was no significant difference between the groups in number and size of voids. In conventional resin composite, most of the voids were present inside the restoration (83.3%), but the voids in the bulk-fill resin composites incidence were higher in the gingivoaxial angle. The cavity wall adaptation demonstrated in class II restorations of primary molar by new bulk fill resin composites was similar to conventional incremental technique. Bulk-fill resin composites might be an clinical option for a faster restoration in deciduous teeth.

FINITE ELEMENT ANALYSIS OF MAXILLARY CENTRAL INCISORS RESTORED WITH VARIOUS POST-AND-CORE APPLICATIONS (여러가지 post-and-core로 수복된 상악 중절치의 유한요소법적 연구)

  • Seo, Min-Seock;Shon, Won-Jun;Lee, Woo-Cheol;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.324-332
    • /
    • 2009
  • The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the theoretical technique, finite element stress-analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia ceramic crown were prepared and 1.5 mm ferrule height was provided. Each model contained cortical bone, trabecular bone, periodontal ligament, 4 mm apical root canal filling, and post-and-core. Six combinations of three parallel type post (zirconia ceramic, glass fiber, and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. A 50 N static occlusal load was applied to the palatal surface of the crown with a $60^{\circ}$angle to the long axis of the tooth. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. An increase of the elastic modulus of the post material increased the stress, but shifted the maximum stress location from the dentin surface to the post material. Buccal side of cervical region (junction of core and crown) of the glass fiber post restored tooth was subjected to the highest stress concentration. Maximum von Mises stress in the remaining radicular tooth structure for low elastic modulus resin core (29.21 MPa) was slightly higher than that for high elastic modulus resin core (29.14 MPa) in case of glass fiber post. Maximum displacement of glass fiber post restored tooth was higher than that of zirconia ceramic or stainless steel post restored tooth.