• Title/Summary/Keyword: Ceramic die

Search Result 115, Processing Time 0.04 seconds

An Axisymmetric Finite Element Analysis of Hot Tube Extrusion Using Ceramic Dies (세라믹 금형을 이용한 열간 튜브 압출의 축대칭 유한요소해석)

  • Kang, Yeon-Sick;Yang, Dong-Yol;Chung, Soon-Kil;Lee, June-Gunn
    • Transactions of Materials Processing
    • /
    • v.7 no.1
    • /
    • pp.72-80
    • /
    • 1998
  • This study is concerned with the thermo-biscoplastic finite element analysis of hot tube extrusion through square dies with a mandrel. The problem is treated as a non-steady state and the ALE description is used due to abruptly turning flow at the die aperture. Since the contact heat transfer coefficient and the friction factor are required in the analysis experiments are also carried out to determine the values, In order to apply ceramics to an extrusion die the study is focussed on under-standing the characteristics of the process. The simulated results provide the useful informations such as metal flow temperature distribution stress state etc. The elastic analysis of the dies is carried out to obtain the stress state of the ceramic dies.

  • PDF

A Study on the Hot Extrusion Dies with $TiB_2$ Insert ($TiB_2$ 인서트를 체결한 열간압출 금형에 관한 연구)

  • Kwon H. H.;Lee J. R.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.05a
    • /
    • pp.106-109
    • /
    • 2001
  • The use of ceramic inserts in hot extrusion dies offers significant technical and economic advantages over other forms of manufacture. These potential benefits can however only be realized by optimal design of the tools so that the ceramic inserts are not subjected to stresses that lead to their premature failure. In this paper, process simulation and stress analysis are thus combined during the design, and a data exchange program has been developed that enables optimal design of the dies taking into account the elastic deflections generated in shrink fitting the die inserts and that caused by the stresses generated in the process. The stress analysis of the dies is used to determine the stress conditions on the ceramic insert by considering contact and interference effects under both mechanical and thermal loads. The results are compared with the experimental ones for verification.

  • PDF

Design of Hot Extrusion Dies for Hexagonal Insert (Hexagonal 인서트용 열간압출 금형설계)

  • 권혁홍;이정로
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.72-77
    • /
    • 2001
  • The use of hexagonal ceramic inserts for copper extrusion dies offers significant technical and economic advantages over other forms of manufacture. In this paper the data on the loading of the tools is determined from a commercial FEM package as the contact stress distribution on the die-workpiece interface and as temperature distributions in the die. This data can be processed as load input data for a finite element die-stress analysis. Process simulation and stress analysis are thus combined during the design, and a data exchange program has been developed that enables optimal design of the dies taking into account the elastic deflections generated in shrink fitting the die inserts and that caused by the stresses generated in the process. The stress analysis of the dies is used to determine the stress conditions on the ceramic insert by considering contact and interference effects under both mechanical and thermal loads.

  • PDF

Tool Wear and Cutting Characteristics in the Machining of Die Material using Ceramic Toll (세라믹 공구를 이용한 금형강 가공시 공구마멸과 절삭특성)

  • 손창수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.114-118
    • /
    • 1996
  • Evaluation of cutting condition is one of the most important aspect to improve productivity and quality. In this study, the wear and cutting characteristics(cutting force, acoustic emission signal and surface roughness) of ceramic cutting tool for hardened die material(SKD11) were investigated by experiment. Flank wear on relief face of tool was occurred more dominant than crater wear on rake face. Experiments were performed under the various cutting condition.

  • PDF

COMPARISON OF FRACTURE STRENGTH BETWEEN HYBRID-CERAMIC CROWN AND METAL-CERAMIC CROWN (Hybrid-Ceramic Crown과 금속 도재관의 파절강도 비교)

  • Ku Chul-Whoi;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.14-24
    • /
    • 2001
  • The purpose of this study was to compare the fracture strengths and the fracture patterns of several hybrid-ceramic crowns and metal-ceramic crown. Ten crowns were constructed for each group according to the manufacturer's instruction. Removable template of silicone rubber impression material was used for standardization of each crowns. Each crown was cemented on a metal die with hybrid glass ionomer cement. All crowns cemented were stored in distilled water, $36^{\circ}C$ for 24 hours prior to loading in an universal testing machine. The load was directed at 130 degrees the long axis of metal die. The fracture strengths were measured and the fracture patterns were observed. The following results were obtained from this study 1. The mean fracture strengths of $Artglass^{(R)}$, $Sculpture^{(R)}$ and $Targis^{(R)}$ were $57.5{\pm}9.5Kgf,\;62.7{\pm}12.2Kgf$ and $60.2{\pm}10.1Kgf$ respectively. There was no significant difference among each hybrid ceramic crown group. 2. The toad required to fracture hybrid-ceramic crowns was significantly smaller than metal-ceramic crowns($131.7{\pm}22.0Kgf$). 3. In the metal-ceramic crowns, labial porcelain detached partially from porcelain-metal junction of proximal side by load. 4. Hybrid-ceramic crowns showed a simple fracture pattern that fracture line began at the loading area and extended through proximal surface, perpendicular to the margin. The crown was separated into two parts of labial side and lingual side. Above results revealed that three kinds of the hybrid-ceramic crowns used in this study must have careful application in clinical use since the strength of hybrid-ceramic crown was lower(about 1/2) than that of metal-ceramic crown.

  • PDF

Densification behavior of ceramic powder under cold compaction (냉간압축 하에서 세락믹 분말의 치밀화 거동)

  • Choi, Seung-Wan;Kim, Gi-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.924-938
    • /
    • 1998
  • Densification behavior of ceramic powder under cold compaction was investigated. Experimental data were obtained for zirconia powder and alumina powder under triaxial compression with various loading conditions. A special form of the Cap model was proposed from experimental data under triaxial compression for a yield function of ceramic powder. The proposed yield function was inplemented into a finite element program (ABAQUS) to study densification behaviors of zirconia and alumina powders under die compaction. The effect of friction between the powder and die wall was also investigated. Density distributions of powder compacts were measured and compared with finite element results.

An Axisymmetric Finite Element Analysis of Hot Tube Extrusion for the design of Ceramic Dies (세라믹 금형설계를 위한 열간 튜브 압출의 축대칭 유한요소해석)

  • 강연식;양동열;정순길;이준근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.882-886
    • /
    • 1996
  • The use of ceramics for extrusion dies is limited since the modification of die design is difficult. In order to successfully apply the ceramic dies to extrusion dies, a better understanding of the process should be preceded. This study focuses on understanding the characteristics of the process. In the present study, a hot extrusion of tube with a mandrel is analyzed by ALE finite element method. In order to obtain the stress state of ceraminc dies, the elastic analysis of dies is also carried out.

  • PDF

A STUDY ON LABIOCERVICAL MARGINAL FITNESS AND MARGINAL ROUNDING OF COLLARLESS METAL CERAMIC RESTORATION (Collarless 도재용착주조관의 치경부 도재 변연부의 적합도 및 rounding의 비교)

  • Shin, Suk-Hoon;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.198-209
    • /
    • 1995
  • In order to evaluate the fitness and the degree of rounding of porcelain margins in collarless metal cermic restorations, collarless metal ceramic restorations were fabricated with shoulder margins of 90 and 120 degress, each consisting of ten specimens, on master dies through the direct lift technique. And ten metal ceramic restorations with a shoulder 90 degrees were fabricated. All specimens were embedded in resin and sectioned longitudinally. The sections were observed under a stereomicroscope and photographed(${\times}$200). The labial marginal gap between the die and the porcelain margin were measured with a scale. The space between the porcelain margin and the die, that is formed from marginal rounding and cementation were calculated with a computer coordinating area curvimeter. The following results were obtained. 1. There was no statistical difference between the fitness of porcelain margin of collarless metal ceramic restorations and marginal fitness of metal ceramic restoration. 2. There was no statistical difference between a shoulder of 90 and 120 degrees in the fitness of porcelain margin of collarless metal ceramic resorations. 3. Collarless metal ceramic restorations with a shoulder of 90 degrees and 120 degrees showed significantly more labial marginal rounding than metal ceramic restorations. 4. There was no statistical difference between a shoulder of 90 and 120 degrees in rounding of porcelain margin of collarless metal ceramic restorations. According to the results, rounding of porcelain margins can be observed in collarless metal ceramic restorations. Thus, there is a need for improvement in dental materials and techniques to minimize this problem, Furthermore, care should be exercised during the clinical procedure.

  • PDF

Fabrication of MCA Valve For MEMS (MEMS용 적층형 압전밸브의 제작)

  • Kim, Jae-Min;Yun, Jae-Young;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.129-132
    • /
    • 2004
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 sccm at a supplied voltage of 100 V with a 50 % duty cycle, maximum non-linearity was 2.24 % FS and leak rate was $3.03{\times}10^{-8}\;pa{\cdot}m^3/cm^2$. Therefore, the fabricated MCA valve is suitable for a variety of flow control equipment, a medical bio-system, automobile and air transportation industry.

  • PDF

Design, Fabrication and Characteristics of a MCA Valve (적층형 압전밸브의 설계, 제작 및 특성)

  • Chung, Gwiy-Sang;Kim, Jae-Min;Yoon, Suk-Jin;Jeong, Soon-Jong;Song, Jae-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.230-235
    • /
    • 2004
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 seem at a supplied voltage of 100 V with a 50% duty cycle, maximum non-linearity was 2.24% FS and leak rate was $3.03{\times}10^{-8}pa{\codt}m^{3}/cm^{2}$. Therefore, the fabricated MCA valve is suitable for a variety of flow control equipment, a medical bio-system, automobile and air transportation industry.