• Title/Summary/Keyword: Ceph

Search Result 47, Processing Time 0.021 seconds

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

Accuracy of soft tissue Profile change prediction in mandibular set-back surgery patients: a comparison of Quick Ceph Image $Pro^{TM}$ (ver 3.0) and $V-Ceph^{TM}$(ver 3.5) (하악골 후퇴 수술 환자의 연조직 측모 예측의 정확성: Quick Ceph Image $Pro^{TM}$(ver 3.0)와 $V-Ceph^{TM}$(Ver 3.5)의 비교)

  • Kim, Myoung-Kyun;Choi, Yong-Sung;Chung, Song-Woo;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.216-226
    • /
    • 2005
  • The purpose of this study was to test and compare the accuracy and reliability of soft tissue profile predictions generated from two computer software programs (Quick Ceph Image $Pro^{TM}$ (ver 3.0) and $V-Ceph^{TM}$(ver 3.5)) for mandibular set-back surgery. The presurgical and postsurgical lateral cephalograms of 40 patients (20 males and 20 females) were traced on the same acetate paper with the reference taken as the cranial base outline. The presurgical skeletal outlines were digitized onto each computer program and the mandible was moved to mimic the expected surgical procedure with reverence to the mandibular anterior border and lower incisor position of the actual postsurgical skeletal outline. The soft tissue profile was generated and the amount and direction of skeletal movement was calculated with each software. The predicted soft tissue profile was compared to the actual postsurgical soft tissue profile. There were differences between the actual and the predicted surgical soft tissue profile charges in the magnitude and direction, especially the upper lip. lower lip and the soft tissue chin (P<0.05). Quick Ceph had more horizontal measurement errors and thickness errors for the upper lip and lower lip, but V-Ceph had more vertical measurement errors of the lower lip (P<0.05). There was a positive correlation between the prediction errors and the amount of mandibular movements in the vertical position of Sn, the horizontal position of Ls and the upper lip thickness for V-Ceph, and there was a negative correlation in the horizontal position and the thickness of the lower lip for Quick Ceph (P<0.05). However all of the Prediction errors of both imaging softwares were ranged within 3mm, and this was considered to be allowable clinically.

Comparison of computer-based treatment prediction with true results in bimaxillary protrusion cases (치조성 양악 전돌 환자에서 컴퓨터를 이용한 치료 결과 예측의 정확성)

  • Lee, Rhi-na;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.155-163
    • /
    • 2002
  • This study was performed to assess the accuracy of computer-based treatment prediction for soft tissue profile using Quick Ceph Image $Pro^{TM}\;&\;Quick\;Ceph\;2000^{TM}$ in bimaxillary protrusion cases. The Ore- and post-treatment lateral cephalograms of 21 female adults treated by low first premolar extraction were imaged and 9 landmarks and 27 specific soft tissue mesurements were digitized for comparing actual treatment results with computer simulations. The results of this study showed that Quick Ceph Image $Pro^{TM}\;&\;Quick\;Ceph\;2000^{TM}$ tends to overestimeate horizontal changes and underestimate vertical changes. In the computer simulation, upper lip showed rolling tendency. The upper lip measurements were disposed to be regular direction hut lower lip measurements were varied case by case even if it was statistically insignificant.

Prototype Design of Mass Distributed Storage System based on PC using Ceph for SMB

  • Cha, ByungRae;Kim, Yongil
    • Smart Media Journal
    • /
    • v.4 no.3
    • /
    • pp.62-67
    • /
    • 2015
  • The trend keywords in ICT sector will be Big Data, Internet of Things, and Cloud Computing. The rear end to support those techniques requires a large-capacity storage technology of low-cost. Therefore, we proposed the prototype of low-cost and mass distributed storage system based on PC using open-source Ceph FS for SMB.

Cloning and Expression of D-amino Acid Oxidise from Trigonopsis variabilis for Cephalosporin C Biotransformation (Cephalosporin C의 생변환을 위한 Trigonopsis variabilis의 D-amino Acid Oxidase 유전자의 클로닝 및 발현)

  • 이진형;정태완
    • KSBB Journal
    • /
    • v.10 no.3
    • /
    • pp.264-270
    • /
    • 1995
  • Trigonopsis variabilis is a strong producer of D-amino acid oxidase that can transform cephalosporin C(ceph C) to ${\alpha}$-keto-adipyl-7-aminocephalosporanic acid(AKA-7ACA). Polymerase chain reaction (PCR) was applied to isolate the D-AAO gene from T. variabilis. To clone the PCR fragment, four different methods were examined using enzymatic reactions of Taq DNA polymerase, Klenow, T4 DNA polymerase I, Alkaline phosphatase Calf Intestinal, and T4 kinase. Ligation of phosphorylated blunt-end PCR fragment and dephosphorylated blunt-end of pUC18 plasmid yielded the best cloning efficiency One of recombinant E. coli transformants showed D-AAO activity against ceph C in both cell extracts and permeabilized cells.

  • PDF

Accuracy of the soft tissue prediction of quick Ceph Image Pro in mandibular setback surgery (하악골 후방이동 수술시 Quick Ceph Image Pro의 연조직 예측 정확도에 관한 연구)

  • Han, Jeong-Heum;Im, Yong-Gyu;Lee, Dong-Yeol
    • The Journal of the Korean dental association
    • /
    • v.41 no.3 s.406
    • /
    • pp.180-189
    • /
    • 2003
  • The purpose of this study was to evaluate the accuracy of the soft tissue profile predicted by Quick Ceph Image Pro in mandibular setback surgery. Preoperative and postoperative lateral cephalograms of 24 patients(9 males and 15 females) who had completed treatment that involved orthodontics and mandibular setback by BSSRO were used. Computerized cephalometric lines and video image predictions were generated and compared with the actual postoperative results. In horizontal measurement, predicted values were smaller than actual measurements. And lips were thicker than actual values. Most of the different between values and actual measurement were than 2mm, and it was clinically acceptable.

  • PDF

Accuracy and reproducibility of landmark of cone beam computed tomography (CT) synthesized cephalograms (Cone beam computed tomography로 합성된 두부규격 방사선사진에서의 각 계측점의 정확도와 재현성에 관한 연구)

  • Kwon, Dae-Keun;Min, Seung-Ki;Jun, In-Chul;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.78-86
    • /
    • 2010
  • Introduction: Cone beam computed tomography (CBCT) has various advantages and is used favorably in many fields in dentistry. Especially, CBCT is being used as basic diagnostic tool for 3-dimensional analysis in orthognathic patient. Two-dimensional cephalograms can be synthesized from CBCT digital imaging and communications in medicine (DICOM) data. In this study, conventional cephalograms and CBCT were taken simultaneously, and representative landmarks were located and analyzed in its accuracy and reproducibility. Materials and Methods: Ten patients who had orthognathic surgery in Wonkwang University Daejeon Dental Hospital participated in this study. For each patient, CBCT and conventional cephalogram was taken. By using Ondemand (Cybermad, Korea), 2-dimensional cephalograms was established on CBCT. In addition, 19 landmarks were designated and measured by 3 orthodontists twice a week. After these landmarks were transferred to a coordinate, distance of landmark and axis, standard error, distribution degree were measured, compared and analyzed. Results: Comparing the CT ceph group and conventional cephalogram group, CT ceph group had shown shorter distance of landmark and axis in S, Hinge axis, Bpt, Ba, Or, Corpus left. Standard error of the mean shows that CT ceph group has better reproducibility in Or, Corpus left, Hinge axis at X axis and Na, U1R, U1T, Bpt, PNS, Ba Corpus left, Hinge axis at Y axis. In both groups, mean error was less than 1.00 mm, no significant difference were found between CT ceph group and conventional cephalogram group in all measurements. Furthermore, comparing two groups, each 17 landmarks out of 19 had its characteristic in distribution degree. Conclusion: No significant difference were found between CBCT composed cephalographic radiograph and conventional cephalograghic radiograph, clinical application may be possible if improved.

Design and Implementation of Software-Defined Storage Autoconfiguration Module for Integrated Use of Cloud File/Block/Object Storage (클라우드 파일/블록/객체 스토리지의 통합사용을 위한 소프트웨어 정의 스토리지 자동 설정 모듈의 설계 및 구현)

  • Park, Sun;Cha, ByungRae;Kim, Jongwon
    • Smart Media Journal
    • /
    • v.7 no.4
    • /
    • pp.9-16
    • /
    • 2018
  • In order to improve the economics and flexibility of cloud computing, tendency to automate the operation and management of cloud resources has become complicated. However, while automation for cloud storage depends on the manufacturer's storage hardware, it cannot flexibly support the storage type in accordance with users' needs. In this paper, we propose an automatic configuration module that supports block/file/object storages suitable for user environment. In order to automatically install ceph, a cloud storage, we propose an automatic installation and configuration module based on the Chef configuration management tool. In addition to that, we also propose an automatic configuration module based on a shell programming in pursuit of enabling users to use ceph storage of block/file/object. The proposed method can automatically set up and manage shared file, block, and object storages in a virtual or physical user environment with no hardware dependencies.

Biopharmaceutical Evaluation of Sustained-Release $Eudragit^{\circledR}$ Microcapsules Containing Cephalexin (서방성 $Cephalexin-Eudragit^{\circledR}$ 마이크로캅셀의 생물약제학적 평가)

  • Han, Kun;Kim, Kwang-Dug;Chung, Youn-Bok;Jee, Ung-Kil;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.2
    • /
    • pp.103-110
    • /
    • 1993
  • Microcapsules(Mc) of cephalexin (CEPH), using Eudragit RS, RL, L, S and polyethylene glycol 1540, were evaluated biopharmaceutically. The area under the curve of CEPH-Eudragit RS/RL Mc administered orally once was larger than that of cephalexin powder twice every 6 hrs. Controlledrelease effectiveness and the absorption rate effectiveness, two important parameters of Vallner's method, of CEPH-Eudragit RS/RL Mc indicate that these Mc can be good sustained-release preparations. And a simple pharmacokinetic model is introduced which allows the gastric emptying and intestinal-transit rates of a drug itself and a solid-state drug contained in Mc. Decreasing $K_r$, without change in $K_a$, showed that the rate-limiting step of absorption moved from absorption step to releasestep.

  • PDF

Performance Enhancement and Evaluation of Distributed File System for Cloud (클라우드 분산 파일 시스템 성능 개선 및 평가)

  • Lee, Jong Hyuk
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.7 no.11
    • /
    • pp.275-280
    • /
    • 2018
  • The choice of a suitable distributed file system is required for loading large data and high-speed processing through subsequent applications in a cloud environment. In this paper, we propose a write performance improvement method based on GlusterFS and evaluate the performance of MapRFS, CephFS and GlusterFS among existing distributed file systems in cloud environment. The write performance improvement method proposed in this paper enhances the response time by changing the synchronization level used by the synchronous replication method from disk to memory. Experimental results show that the distributed file system to which the proposed method is applied is superior to other distributed file systems in the case of sequential write, random write and random read.