• 제목/요약/키워드: Ceph

검색결과 47건 처리시간 0.025초

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • 대한치과교정학회지
    • /
    • 제48권5호
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

하악골 후퇴 수술 환자의 연조직 측모 예측의 정확성: Quick Ceph Image $Pro^{TM}$(ver 3.0)와 $V-Ceph^{TM}$(Ver 3.5)의 비교 (Accuracy of soft tissue Profile change prediction in mandibular set-back surgery patients: a comparison of Quick Ceph Image $Pro^{TM}$ (ver 3.0) and $V-Ceph^{TM}$(ver 3.5))

  • 김명균;최용성;정송우;전영미;김정기
    • 대한치과교정학회지
    • /
    • 제35권3호
    • /
    • pp.216-226
    • /
    • 2005
  • 본 연구는 Quick Ceph Image $Pro^{TM}$(ver 3.0)와 국내에서 개발되어 사용 중인 $V-Ceph^{TM}$(ver 3.5) 2 종의 비디오 이미지 예측 프로그램의 수술 후 연조직 측모의 정확성과 신뢰성에 대해서 알아보고자 시행되었다. 골격성 III급 부정교합으로 진단되어 수술 전 교정 치료를 받고. 하악골 후퇴 수술(body osteotomy 또는 SSRO)을 시행한 남녀 환자 각각 20명을 대상으로 하였다. 나이는 평균 $21.4\pm4$세이고, 수술 전 측모두부방사선계측사진은 수술 전 평균 21.1일에 수술 후 측모두부방사선계측사진은 수술 후 평균 335.7일에 촬영되었으며, 예측치와 실측치 차이를 비교하였다. 연구결과 Quick Ceph과 V-Ceph 모두 예측치와 실측치 사이에 크기와 방향에 있어서 오차가 관찰되었으며, 이러한 오차는 상순과 하순. 턱과 연관된 항목에서 크게 나타났다 (p<0.05). Quick Ceph은 A'. Ls, Li의 수평적 위치 및 각 부분에서의 연조직 두께(U1-Ls, L1-Li, Pog-Pog')의 수평거리 예측에서, V-Ceph은 하순의 수직적 위치 예측에서 오차가 컸다 (p<0.05) V-Ceph의 경우 하악골의 이동양이 증가할때 Sn의 수직적 위치, Ls의 수평적 위치 상순의 연조직 두께 (U1 -Ls)처럼 상순과 연관된 계측치에서 예측오차가 컸으며, Quick Ceph의 경우 하악골의 이동양이 증가할 때 하순의 수평위치 및 하순의 두께에서의 예측오차가 작았다 (P<0,05) 또한, 연조직의 두께에 따른 오차를 평가한 결과, Quick Ceph의 경우 상순과 하순의 두께가 두꺼울수록 각각에 관련된 연조직 예측의 오차가 컸으며 (P<0.05). V-Ceph의 경우 하순과 턱의 연조직 두께가 두꺼울수록 턱의 연조직 예측의 오차가 크게 관찰되었다 (p<0.05). 그러나 본 연구에서의 모든 예측오차 값은 3mm 이내로 계측되었으며, 이러한 오차 범주는 임상적으로 허용 가능한 수준인 것으로 생각된다.

치조성 양악 전돌 환자에서 컴퓨터를 이용한 치료 결과 예측의 정확성 (Comparison of computer-based treatment prediction with true results in bimaxillary protrusion cases)

  • 이리나;임용규;이동렬
    • 대한치과교정학회지
    • /
    • 제32권3호
    • /
    • pp.155-163
    • /
    • 2002
  • 치조성 양악 전돌 증례에서 컴퓨터 시뮬레이션을 이용한 연조직 측모의 치료 결과 예측의 객관적 정확성을 상, 하악 제 1소구치 발거를 통해 교정치료를 받은 21명의 성인 여성을 대상으로 $Quick\;Ceph\;Image\;Pro^{TM}\;&\;Quick Eeph\;2000^{TM}$ 을 이용하여 조사, 평가하였다. 치료 전 측모 두부방사선 규격사진 투사도에서 경조직 이동량을 계측하고 Quick Ceph system 상에서 경조직을 동일한 양 이동시켜 컴퓨터시뮬레이 션을 위한 기준으로 삼았다. 이후 프로그램을 통해 연조직 변화를 시뮬레이션하고, 이 자료와 실제 치료 결과로 얻어진 연조직 계측 값을 측정하여 비교해 봄으로써 치료 결과 예측에 대한 정확도를 확인하고 임상에의 적용시 고려할 사항을 알아보았다. 시뮬레이션 결과 계측 항목의 수평 성분은 실제 치료 결과보다 작게, 수직 성분은 치료 결과보다 크게 예측하는 것으로 나타났으며 치료시 의 후방 견인은 실제보다 확대되어 나타나는 경 향을 보였다. 상악에서는 항목간 예측 오차의 방향이 일정하여 예측치가 실제보다 더 후방 이동되어 나타났으나, 하악에서는 증례간 차이가 컸다 Upper Lip Length는 짧게, Upper Vermilion Length는 길게 예측하여 시뮬레이션시 상순이 말려 보이는(rolling)효과를 확인할 수 있었으며 하순에서도 유사한 성향이 나타났으나 상순에 비해서 약하게 나타났다.

Prototype Design of Mass Distributed Storage System based on PC using Ceph for SMB

  • Cha, ByungRae;Kim, Yongil
    • 스마트미디어저널
    • /
    • 제4권3호
    • /
    • pp.62-67
    • /
    • 2015
  • The trend keywords in ICT sector will be Big Data, Internet of Things, and Cloud Computing. The rear end to support those techniques requires a large-capacity storage technology of low-cost. Therefore, we proposed the prototype of low-cost and mass distributed storage system based on PC using open-source Ceph FS for SMB.

Cephalosporin C의 생변환을 위한 Trigonopsis variabilis의 D-amino Acid Oxidase 유전자의 클로닝 및 발현 (Cloning and Expression of D-amino Acid Oxidise from Trigonopsis variabilis for Cephalosporin C Biotransformation)

  • 이진형;정태완
    • KSBB Journal
    • /
    • 제10권3호
    • /
    • pp.264-270
    • /
    • 1995
  • Trigonopsis variabilis는 버l타락탐 항생제인 cephalosporin C (ceph C)를 ${\alpha}$-keto-adipyl-7 a aminocephalosporanic acid(AKA-7 ACA)로 생변 환하는 강력한 D-amino acid oxidase 효소를 갖고 있다. 본 연구는 이 D-AAO 효소의 유전자를 추출하기 위하여 polymerase chain reaction (PCR)을 사용하였다. PCR 단편을 콜로닝하기 위하여 Taq D DNA polymerase, Klenow, T4 DNA polymerase I, Alkaline phosphatase Calf Intestinal와 T4 kinase 의 효소반응을 이용하여 4가지의 방법을 샤용한 결 과, blunt - end 의 PCR fragment 를 phosphory­l lation하고 blunt -end의 pUC18 plasmid를 dephos phorylation 한 후 ligation 한 것 이 가장 좋은 클로 닝 효율을 보였다. Ceph C에 대한 D-AAO 효소의 활성은 재조합 E. coli의 세포추출액과 permea bilized cells에서 모두 확인할 수 있었다.

  • PDF

하악골 후방이동 수술시 Quick Ceph Image Pro의 연조직 예측 정확도에 관한 연구 (Accuracy of the soft tissue prediction of quick Ceph Image Pro in mandibular setback surgery)

  • 한정흠;임용규;이동열
    • 대한치과의사협회지
    • /
    • 제41권3호통권406호
    • /
    • pp.180-189
    • /
    • 2003
  • The purpose of this study was to evaluate the accuracy of the soft tissue profile predicted by Quick Ceph Image Pro in mandibular setback surgery. Preoperative and postoperative lateral cephalograms of 24 patients(9 males and 15 females) who had completed treatment that involved orthodontics and mandibular setback by BSSRO were used. Computerized cephalometric lines and video image predictions were generated and compared with the actual postoperative results. In horizontal measurement, predicted values were smaller than actual measurements. And lips were thicker than actual values. Most of the different between values and actual measurement were than 2mm, and it was clinically acceptable.

  • PDF

Cone beam computed tomography로 합성된 두부규격 방사선사진에서의 각 계측점의 정확도와 재현성에 관한 연구 (Accuracy and reproducibility of landmark of cone beam computed tomography (CT) synthesized cephalograms)

  • 권대근;민승기;전인철;팽준영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.78-86
    • /
    • 2010
  • Introduction: Cone beam computed tomography (CBCT) has various advantages and is used favorably in many fields in dentistry. Especially, CBCT is being used as basic diagnostic tool for 3-dimensional analysis in orthognathic patient. Two-dimensional cephalograms can be synthesized from CBCT digital imaging and communications in medicine (DICOM) data. In this study, conventional cephalograms and CBCT were taken simultaneously, and representative landmarks were located and analyzed in its accuracy and reproducibility. Materials and Methods: Ten patients who had orthognathic surgery in Wonkwang University Daejeon Dental Hospital participated in this study. For each patient, CBCT and conventional cephalogram was taken. By using Ondemand (Cybermad, Korea), 2-dimensional cephalograms was established on CBCT. In addition, 19 landmarks were designated and measured by 3 orthodontists twice a week. After these landmarks were transferred to a coordinate, distance of landmark and axis, standard error, distribution degree were measured, compared and analyzed. Results: Comparing the CT ceph group and conventional cephalogram group, CT ceph group had shown shorter distance of landmark and axis in S, Hinge axis, Bpt, Ba, Or, Corpus left. Standard error of the mean shows that CT ceph group has better reproducibility in Or, Corpus left, Hinge axis at X axis and Na, U1R, U1T, Bpt, PNS, Ba Corpus left, Hinge axis at Y axis. In both groups, mean error was less than 1.00 mm, no significant difference were found between CT ceph group and conventional cephalogram group in all measurements. Furthermore, comparing two groups, each 17 landmarks out of 19 had its characteristic in distribution degree. Conclusion: No significant difference were found between CBCT composed cephalographic radiograph and conventional cephalograghic radiograph, clinical application may be possible if improved.

클라우드 파일/블록/객체 스토리지의 통합사용을 위한 소프트웨어 정의 스토리지 자동 설정 모듈의 설계 및 구현 (Design and Implementation of Software-Defined Storage Autoconfiguration Module for Integrated Use of Cloud File/Block/Object Storage)

  • 박선;차병래;김종원
    • 스마트미디어저널
    • /
    • 제7권4호
    • /
    • pp.9-16
    • /
    • 2018
  • 클라우드 컴퓨팅(Cloud Computing)의 경제성과 유연성을 향상시키기 위해 복잡해지는 자원의 운영 및 관리를 자동화하는 추세에 있다. 그러나 클라우드 스토리지에 대한 자동화는 제조업체의 스토리지 하드웨어에 종속되나, 사용자가 필요로 하는 용도에 맞추어 스토리지 유형을 유연하게 지원할 수 없다. 본 논문에서는 클라우드 스토리지의 자동화 추세에 맞추어 사용자의 환경에 연계한 블록/파일/객체 스토리지를 통합으로 지원하는 자동 설정 모듈을 제안한다. 제안방법은 클라우드 스토리지인 ceph을 자동으로 설치하기 위하여 Chef 구성관리도구 기반의 자동설치 및 설정 모듈을 제안하였으며, 사용자들이 ceph 스토리지를 쉽게 사용할 수 있도록 쉘 프로그램 기반의 블록/파일/객체 스토리지 자동설정 모듈을 제안하였다. 제안방법은 하드웨어 종속 없이 가상이나 물리적인 사용자 환경에서도 자동적으로 공유파일 스토리지, 블록 스토리지, 객체 스토리지에 대한 설정 및 관리를 쉽게 할 수 있다.

서방성 $Cephalexin-Eudragit^{\circledR}$ 마이크로캅셀의 생물약제학적 평가 (Biopharmaceutical Evaluation of Sustained-Release $Eudragit^{\circledR}$ Microcapsules Containing Cephalexin)

  • 한건;김광덕;정연복;지웅길;김신근
    • Journal of Pharmaceutical Investigation
    • /
    • 제23권2호
    • /
    • pp.103-110
    • /
    • 1993
  • Microcapsules(Mc) of cephalexin (CEPH), using Eudragit RS, RL, L, S and polyethylene glycol 1540, were evaluated biopharmaceutically. The area under the curve of CEPH-Eudragit RS/RL Mc administered orally once was larger than that of cephalexin powder twice every 6 hrs. Controlledrelease effectiveness and the absorption rate effectiveness, two important parameters of Vallner's method, of CEPH-Eudragit RS/RL Mc indicate that these Mc can be good sustained-release preparations. And a simple pharmacokinetic model is introduced which allows the gastric emptying and intestinal-transit rates of a drug itself and a solid-state drug contained in Mc. Decreasing $K_r$, without change in $K_a$, showed that the rate-limiting step of absorption moved from absorption step to releasestep.

  • PDF

클라우드 분산 파일 시스템 성능 개선 및 평가 (Performance Enhancement and Evaluation of Distributed File System for Cloud)

  • 이종혁
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제7권11호
    • /
    • pp.275-280
    • /
    • 2018
  • 클라우드 환경에서 빅데이터 적재와 이후 애플리케이션을 통한 고속 처리를 위해서는 적합한 분산 파일 시스템의 선택이 요구된다. 본 논문에서는 GlusterFS 기반 쓰기 성능 향상 방법을 제안하고 클라우드 환경에서 기존 분산 파일 시스템 중 MapRFS, CephFS, GlusterFS와 성능을 비교 평가한다. 본 논문에서 제안한 쓰기 성능 향상 방법은 동기식 스토리지 복제 방식에서 사용하는 동기화 수준을 디스크에서 메모리로 변경함으로써 응답 시간을 향상 시킨다. 실험 결과는 본 논문의 제안 방법이 적용된 분산 파일 시스템이 순차 쓰기의 경우와 랜덤 쓰기와 랜덤 읽기가 혼합된 경우에서 다른 분산 파일 시스템 대비 성능이 우수함을 보인다.