• 제목/요약/키워드: Centralized operation

검색결과 113건 처리시간 0.028초

The Advanced Voltage Regulation Method for ULTC in Distribution Systems with DG

  • Kim, Mi-Young;Song, Yong-Un;Kim, Kyung-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.737-743
    • /
    • 2013
  • The small-scaled onsite generators such as photovoltaic power, wind power, biomass and fuel cell belong to decarbonization techniques. In general, these generators tend to be connected to utility systems, and they are called distributed generations (DGs) compared with conventional centralized power plants. However, DGs may impact on stabilization of utility systems, which gets utility into trouble. In order to reduce utility's burdens (e.g., investment for facilities reinforcement) and accelerate DG introduction, the advanced operation algorithms under the existing utility systems are urgently needed. This paper presents the advanced voltage regulation method in power systems since the sending voltage of voltage regulators has been played a decisive role restricting maximum installable DG capacity (MaxC_DG). For the proposed voltage regulation method, the difference from existing voltage regulation method is explained and the detailed concept is introduced in this paper. MaxC_DG estimation through case studies based on Korean model network verifies the superiority of the proposed method.

분산 다중 센서 기반 실험실 안전 관리 시스템 (Distributed Multi-Sensor based Laboratory Safety Management System)

  • 황도연;김황룡;김은성;정대진;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.585-586
    • /
    • 2019
  • 본 논문에서는 중앙 집중형이 아닌 분산 환경에서 시약장 내부 환경을 분석하여 위험상황의 식별 및 기기 제어를 수행할 수 있는 분산 제어가 가능한 분산 IoT 센서 기반 안전 실험실 관리 시스템에 대해 연구한다. 이를 위해 시약장 내부 환경을 감지하기 위해 다중센서를 적용한다. 또한 이와 같은 시약장이 다수 설치되어 있는 실험실에 대하여 관리자의 히스토리 분석 기반의 자동제어 알고리즘을 적용한 안전관리 시스템을 연구한다.

  • PDF

A central facility concept for nuclear microreactor maintenance and fuel cycle management

  • Faris Fakhry;Jacopo Buongiorno;Steve Rhyne;Benjamin Cross;Paul Roege;Bruce Landrey
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.855-865
    • /
    • 2024
  • Commercial deployment of nuclear microreactors presents an opportunity for the industry to rethink its approach to manufacturing, siting, operation and maintenance, and fuel cycle management as certain principles used in grid-scale nuclear projects are not applicable to a decentralized microreactor economy. The success of this nascent industry is dependent on its ability to reduce infrastructure, logistical, regulatory and lifecycle costs. A utility-like 'Central Facility' that consolidates the services required and responsibilities borne by vendors into one or a few centralized locations will be necessary to support the deployment of a fleet of microreactors. This paper discusses the requirements for a Central Facility, its implications on the cost structures of owners and suppliers of microreactors, and the impact of the facility for the broader microreactor industry. In addition, this paper discusses the pre-requisites for eligibility as well as the opportunities for a Central Facility host site. While there are many suitable locations for such a capability across the U.S., this paper considers a facility co-located with the Vogtle Nuclear Power Plant and Savannah River Sites to illustrate how a Central Facility can leverage the existing infrastructure and stimulate a local ecosystem.

음영지역 발생으로 인한 태양광 발전손실 최소화를 위한 모듈부착형 전력보상기술에 관한 연구 (A Study on Module-based Power Compensation Technology for Minimizing Solar Power Loss due to Shaded Area)

  • 김영백;송법성
    • 한국전자통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.539-546
    • /
    • 2018
  • 최근 태양광발전시장이 급격히 증가하면서 태양전지 모듈 출력 최소화를 위한 연구에 관심이 집중되고 있다. 태양광 발전에서 부정합이 발생하면 옵티마이저의 역할이 중요하다. 기존의 시스템에서는 중앙 집중형 인버터 방식과 직렬형 마이크로인버터방식을 주로 사용되고 있다. 본 논문에서는 기존의 시스템 구성방식과 부정합으로 인한 발전효율 손실 문제를 분석하였다. 또한 음영으로 인한 부정합이 발생하게 되면 이를 개선할 수 있는 모듈 부착형 전력보상방식을 제안하였다. 제안한 모듈 부착형 옵티마이저를 구현하여 기존의 운영방식과 비교, 분석한 결과 제안한 운영방식의 효율이 크게 향상됨을 확인하였다.

마이크로그리드시스템의 분산 에너지관리시스템 설계를 위한 통합시뮬레이션 모델 개발 (Integrated Simulation Model for Designing Distributed Energy Management System in Microgrid System)

  • 조재훈;박선홍;이대종;조영임;전명근
    • 한국지능시스템학회논문지
    • /
    • 제21권1호
    • /
    • pp.29-35
    • /
    • 2011
  • 본 논문에서는 신재생에너지원을 포함하는 독립형 마이크로그리드시스템의 멀티에이전트시스템 기반의 분산에너지관리시스템 설계를 위한 통합시뮬레이션 모델을 제안한다. 멀티에이전트기반 분산에너지관리시스템은 일반적인 중앙에너지관리시스템에 비해 여러 장점들을 가지고 있으나 각 상태에 따른 설계가 비교적 복잡하여 기존의 전력시스템 도구를 이용하여 분산 에너지관리시스템을 설계하기에는 많은 어려운 점들이 있었다. 또한 설계된 에너지관리시스템을 실제 시스템에 적용하여 평가하는 것은 비능률적이기 때문에 효과적인 에너지관시스템을 설계하기 위해서는 통합시뮬레이션 모델이 필요하다. 제안된 통합시뮬레이션 모델은 Matlab/Simpowersystem 기반의 마이크로그리드시스템의 시뮬레이션 모델과 이벤트기반의 알고리즘 설계에 많은 장점이 있는 Matlab/StateFlow을 이용하여 설계된 멀티에이전트기반의 분산에너지관리시스템으로 구성되었다. 통합시뮬레이션 모델의 효용성을 보이기 위하여 특정한 동작 조건들에서 제안된 모델의 출력들을 분석하였다.

지방화시대의 항만공사 도입과 활성화 방안 (Introduction of Port Authority and Activation Schemes in the Age of Localization)

  • 김홍섭
    • 한국항만경제학회지
    • /
    • 제19권2호
    • /
    • pp.87-109
    • /
    • 2003
  • Localization is one of the typical phenomena of this age in Korea. Localization of Port is on the beginning in this Country as the introduction of Port Authority in the Port of Busan and Incheon. As the condition of world trade has been changed, the level of Competition among Ports is severer than before, especially in the East Asia Area. Since many experts of Port say that centralized control system of Port has many Problems, some other Port Control system has been studied and suggested for long time. One of the Countermeasures of these Port Problems is Port Authority System which aims the balance of central and local development. Port Authority System does not want to achieve only Public Duty or Utility but also Commerciality which is fundamentally very important for the survival of Port. In this Paper, the necessities of Port Authority Introduction in Korea was explained. And Port Authority System will be introduced 2004 year in Busan Port firstly and Incheon Port, secondly. The Main Contents of Port Authority System was suggested , in this Paper and some Problems which shall be considered for better operation of Port Authority System was investigated. I suggested some countermeasures, endeavoring the competitive advantage of Port and higher Port Performance, in terms of 3 Dimensions. One is in the side of basic Policy Directions, the other is the activation schemes of functional department which composed of many activities of Port Authority System and the third is in the side of operation body. As this paper, however, has some limitations and Port Authority System is just beginning stage, future research shall be continued in real and concrete level.

  • PDF

저전압 대전류 LLC 공진형 컨버터를 이용한 그린 PC용 전원공급장치 설계 (Design of Power Supply for Green PC using Low Voltage High Current LLC Resonant Converter)

  • 유영도;김인동;노의철;류명효;백주원
    • 전력전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.211-219
    • /
    • 2014
  • This paper proposes a low voltage high current LLC resonant converter for Green PC. Green PC is composed of a lot of blade PCs, and it is a centralized system to manage them in computer center. Green PC should require that its power supplies have several characteristics such as low output voltage, high output current, and high power conversion efficiency. Conventional PSFB (Phase Shift Full Bridge) converter is usually used as DC/DC converter for computer power supply because it has high power conversion efficiency thanks to ZVS (Zero Voltage Switching) operation under middle and high load conditions. However, this converter has some problems such as large switching noise and limitation of ZVS operation under light load condition. In order to improve the performance of power supply for Green PC, a new power supply using popular high efficiency LLC resonant converter for low voltage and high current application is proposed in this paper. The proposed power supply has ZVS capability over the entire load range, thus resulting in good efficiency and high switching frequency. Experimental results verify the performance of the proposed power supply for Green PC using 2[kW] (19[V], 105[A]) rated prototype converter.

블록체인 시스템의 보안성 분석: 암호 화폐에서의 사례 연구 (Security Analysis of Blockchain Systems: Case Study of Cryptocurrencies)

  • 이성범;이부형;명세인;이종혁
    • 정보보호학회논문지
    • /
    • 제28권1호
    • /
    • pp.5-14
    • /
    • 2018
  • 최근 4차 산업혁명으로 인해 사물인터넷 기반의 다양한 기술들이 활발하게 연구되고 있다. 사물인터넷 시대에는 기존 서버-클라이언트 구조의 중앙 집중형 운영보다는 서버에 부하를 줄이고 자율적인 사물간 데이터 통신에 적합한 피어-피어 구조의 분산형 운영방식이 요구 되고 있다. 본 논문에서는 데이터에 대한 무결성과 영속성을 지원하는 새로운 형태의 분산형 데이터베이스 기술인 블록체인에 대해 설명하고, 보안성을 분석한다. 이를 위해 블록체인의 주요한 동작을 합의 과정, 네트워크 통신 과정, 키 관리 과정으로 구분하여 각 과정에서의 가능한 공격과 대응책을 설명한다. 또한 대표적인 암호화폐 플랫폼인 비트코인과 이더리움에서 발생했던 공격들에 대해 기술한다.

교통사고 전후 동적 정보 제공 및 해제 전략 (Dynamic Traffic Information Provision and Dismissal Strategy for Before and After Traffic Incident)

  • 전교석;김태완;이현미;장정아
    • 한국전자통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.867-878
    • /
    • 2021
  • 최근 도로조명시설에 영상 및 레이더 등을 부착하여, 실시간 교통데이터 수집과 교통 정보제공이 가능한 스마트 가로등에 대한 연구가 활발하다. 스마트 가로등 기술은 이에 따라 기존 대비 고해상도 검지, 판별, 조밀한 정보제공이 가능하다. 스마트 가로등의 장점으로 고해상도 정보전달매체로서 효과적으로 활용하기 위해서는 기존 중앙집중식 운영 전략과 다른 지점형 운영 전략이 요구된다. 본 연구는 스마트 가로등 기반사고 발생 전/후의 상황에 따라 구분된 공간적 범위에서 목적성을 달리하는 동적 정보 제공 전략, 해제 전략 및 그 기준에 대해서 제시하였다. 이를 통해 스마트 도로조명시설을 보다 효과적으로 활용 가능할 것으로 기대된다.

A Study on the Improvement of Police Committee System in Korea - Focus on the National Police Committee -

  • Lee, Young-Woo;Jang, Su-Yeon
    • 한국컴퓨터정보학회논문지
    • /
    • 제26권3호
    • /
    • pp.143-146
    • /
    • 2021
  • 우리나라 경찰은 광복 이후 국가경찰제도로 자리 잡아 오랜 기간 동안 중앙집권적 경찰제도로 운영되어 왔으며, 1991년 「경찰법」의 제정으로 경찰위원회가 설립되었다. 그러나 경찰위원회는 경찰행정과 관련된 주요정책 등을 심의·의결하는 기관이 아닌 단순 자문기관에 불과한 것으로 본래의 국가경찰위원회의 기능을 수행하지 못하는 문제점이 있다. 이에 2020년 「경찰법」 전부개정안이 통과되어 법이 「국가경찰과 자치경찰의 조직 및 운영에 관한 법률」로 변경·개정됨에도 불구하고 여전히 운영상, 구성상 문제점이 존재하고 있다. 따라서 본 연구에서는 경찰위원회제도의 운영현황 및 문제점과 그에 대한 개선방안을 제안하고자 한다.