• 제목/요약/키워드: Central ray

검색결과 355건 처리시간 0.028초

A Low-cost Optimization Design for Minimizing Chromatic Aberration by Doublet Prisms

  • Sun, Wen-Shing;Tien, Chuen-Lin;Sun, Ching-Cherng;Lee, Ching-Chun
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.336-342
    • /
    • 2012
  • A low-cost optimal double-prism method is proposed by using the developed MATLAB program to correct chromatic aberration. We present an efficient approach to choose a couple of low-cost glasses to obtain a low aberration double prism. The doublet prisms were made of two lead-free glasses. The relative partial dispersion of the two lead-free glasses is identical and their Abbe numbers are different greatly. The proposed design aims to minimize chromatic aberration, such as in apochromats, for paraxial ray tracing. Finally, an optimization design for real ray tracing can be evaluated by the chromatic aberration curve with a minimal area.

CHARACTERIZING THE TIME-FREQUENCY PROPERTIES OF THE 4 Hz QUASI-PERIODIC OSCILLATION AROUND THE BLACK HOLE X-ray BINARY XTE J1550-564

  • SU, YI-HAO;CHOU, YI;HU, CHIN-PING;YANG, TING-CHANG;HSIEH, HUNG-EN;CHUANG, PO-SHENG;LIN, CHING-PING;LIAO, NAI-HUI
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.587-589
    • /
    • 2015
  • We present the results from analysis of the Hilbert-Huang transform (HHT) for the 4 Hz quasi-periodic oscillations (QPO) around the black hole X-ray binary XTE J1550-564. The resultant Hilbert spectra demonstrate that the QPO is composed of a series of intermittent signals appearing occasionally. From the analysis of the HHT, we further found the distribution of the lifetimes for the intermittent oscillations and the distribution for the time intervals with no significant signal (the break time). The mean lifetime is 1.45 s and 90% of the oscillation segments have lifetimes less than 3.1 s whereas the mean break time is 0.42 s and 90% of break times are less than 0.73 s. We conclude that the intermittent feature of the QPO could be explained by the Lense-Thirring precession model and rules out interpretations of continual frequency modulation.

광경로 시뮬레이션을 이용한 GaN-LED칩의 광추출 효율 분석 (Analysis of the extraction efficiency in GaN-light emitting diodes using ray tracing simulation)

  • 이진복;윤상호;김동운;최창환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.575-576
    • /
    • 2006
  • It was analyzed qualitatively the light extraction in GaN-on-sapphire LEDs based on a simple model. The light extraction efficiency in the LEDs is simulated numerically by using ray tracing method. In the present study, the extraction efficiency was simulated on three different types of LEDs, which a have a different pattered sapphire substrate. And, the role of the patterned sapphire substrate are analyzed and discussed. Based on the analysis, the improvements of extraction efficiency in the LED structures were discussed and these analyses are helpful in the design of high brightness GaN LEDs.

  • PDF

슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가 (Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint)

  • 김현진;주영철;최재호;임우택
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

나노 X-선 쉐도우 마스크를 이용한 고폭비의 나노 구조물 제작 (A Novel Fabrication Method of the High-Aspect-Ratio Nano Structure (HAR-Nano Structure) Using a Nano X-Ray Shadow Mask)

  • 김종현;이승섭;김용철
    • 대한기계학회논문집A
    • /
    • 제30권10호
    • /
    • pp.1314-1319
    • /
    • 2006
  • This paper describes the novel fabrication method of the high-aspect-ratio nano structure which is impossible by conventional method using a shadow mask and a Deep X-ray Lithography (DXRL). The shadow mask with $1{\mu}m-sized$ apertures is fabricated on the silicon membrane using a conventional UV-lithography. The size of aperture is reduced to 200nm by accumulated low stress silicon nitride using a LPCVD (low pressure chemical vapor deposition) process. The X-ray mask is fabricated by depositing absorber layer (Au, $3{\mu}m$) on the back side of nano shadow mask. The thickness of an absorber layer must deposit dozens micrometers to obtain contrast more than 100 for a conventional DXRL process. The thickness of $3{\mu}m-absorber$ layer can get sufficient contrast using a central beam stop method, blocking high energy X-rays. The nano circle and nano line, 200nm in diameter in width, respectively, were demonstrated 700nm in height with a negative photoresist of SU-8.

Circumnuclear gas around the central AGN in a cool-core cluster, A1644-South

  • Baek, Junhyun;Chung, Aeree;Kim, Jae-Woo;Jung, Taehyun
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.30.2-31
    • /
    • 2020
  • We present the properties of circumnuclear gas associated with the AGN located in the center of Abell 1644-South. A1644-S is the main cluster in a merging system, which is also known for gas sloshing in its core as seen in X-ray. The X-ray emission of A1644-S shows a rapidly declining profile, indicating the presence of cooling gas flow. This flow of cool gas may fuel the supermassive black hole embedded in the brightest cluster galaxy, leading to the activation of the central AGN. Indeed, we find a parsec-scale bipolar jet feature in the center of A1644-S in our recent KaVA observation, which implies that its central AGN is likely to have been (re)powered quite recently. In order to verify the hypothesis that cooling gas flow in the cluster core can (re)activate the central AGN, we probe the cold gas properties of the central 1 kpc region of A1644-S using the archival VLA and ALMA data. Based on the spatially resolved morphology and kinematics of HI and CO gas, we challenge to identify inflow/outflow gas streams and clumps. We study the role of circumnuclear cool gas in fueling the centrally located cluster AGN in the cool-core environment. We also discuss how the feedback due to the (re)powered AGN affects the surrounding medium.

  • PDF

X-ray properties of PWNe measured with the NuSTAR telescopes

  • An, Hongjun
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.43.1-43.1
    • /
    • 2018
  • Young pulsar wind nebulae, powered by energetic central pulsars, are often observed as bright extended sources in the X-ray band. They are believed to accelerate electrons and positrons to very high energy and can possibly explain the positron excess observed by Fermi and AMS. The electron distribution in these PWNe can be best studied by X-ray satellites because emission in the X-ray band is produced by direct synchrotron radiation of the electrons and positrons. We present NuSTAR studies of PWNe and discuss the implication. Future studies to help further our understanding of particle acceleration will be briefly discussed.

  • PDF

An Application of Hilbert-Huang Transform on the Non-Stationary Astronomical Time Series: The Superorbital Modulation of SMC X-1

  • Hu, Chin-Ping;Chou, Yi;Wu, Ming-Chya;Yang, Ting-Chang;Su, Yi-Hao
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권2호
    • /
    • pp.79-82
    • /
    • 2013
  • We present the Hilbert-Huang transform (HHT) analysis on the quasi-periodic modulation of SMC X-1. SMC X-1, consisting of a neutron star and a massive companion, exhibits superorbital modulation with a period varying between ~40 d and ~65 d. We applied the HHT on the light curve observed by the All-Sky Monitor onboard Rossi X-ray Timing Explorer (RXTE) to obtain the instantaneous frequency of the superorbital modulation of SMC X-1. The resultant Hilbert spectrum is consistent with the dynamic power spectrum while it shows more detailed information in both the time and frequency domains. According to the instantaneous frequency, we found a correlation between the superorbital period and the modulation amplitude. Combining the spectral observation made by the Proportional Counter Array onboard RXTE and the superorbital phase derived in the HHT, we performed a superorbital phase-resolved spectral analysis of SMC X-1. An analysis of the spectral parameters versus the orbital phase for different superorbital states revealed that the diversity of $n_H$ has an orbital dependence. Furthermore, we obtained the variation in the eclipse profiles by folding the All Sky Monitor light curve with orbital period for different superorbital states. A dip feature, similar to the pre-eclipse dip of Her X-1, can be observed only in the superorbital ascending and descending states, while the width is anti-correlated with the X-ray flux.

국내 X-선 촬영술에 있어서 실패의 원인분석에 관한 연구 (THE STUDY OF TECHNICAL FAILURE OF INTRAORAL ROENTGENOGRAPHY)

  • 강용상
    • 치과방사선
    • /
    • 제7권1호
    • /
    • pp.27-30
    • /
    • 1977
  • To insure accuracy in dental roentgenographs, it is important that the patient's head position and angulation of the x-ray tube. In 1907 Cieszynski applied the rule of isometry to dental radiography and established that in the production of an accurate image of a tooth, the central ray must be porjected perpendicularly to a plane bisecting angle formed by the longitudinal axis of the tooth and the film plane. Proper exposure of the film is a part of the production of a good dental radiograph, and correct processing also makes an essential contribution to the quality of the radiograph. The author analysed the failure of exposure and processing results, and recommended followings. 1. The patient head must be positioned that occlusal plane are parallel with the horizontal floor. 2. Central ray must be projected to the objective tooth and supporting structure and projected as perpendicularly to tooth axis and film surface as possible. 3. In processing, the temperature of the solution and the processing time must be correct.

  • PDF