• 제목/요약/키워드: Central X-ray

Search Result 272, Processing Time 0.026 seconds

Avascular Necrosis of Femoral Head on Bone Scan (대퇴골두 무혈성 괴사의 뼈스캔상의 병기)

  • Yang, Hyung-In;Kim, Eui-Jong;Kim, Deog-Yoon;Ryu, Kyung-Nam;Cho, Kyung-Sam
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.206-213
    • /
    • 1994
  • We studied 90 patients(179 femoral heads) with avascular necrosis of femoral head, who had been performed X-ray, bone scan and MRI to compare of the findings of AVN on bone scan between each other, retrospectively. The patients were 82 males and 9 females, their mean age was 45 years. Radiographic stages were classified by Steinberg modification, radionuclide stages were classified as followed; stage o(or type 0) : normal, stage 1 : faint ring like uptake around the femoral head, stage 2: intense ring like uptake, stage 3: irregular increased uptake with central photon defect, stage 4 : Intense diffuse increased uptake at femoral head and stage 5 : hip joint deformity with relatively mild increased uptake. The findings of MRI were classified according to extent, location, early or advanced lesion, signal intensity of the lesion and joint effusion. 156(87%) of 179 femoral heads had avascular necrosis, 68(75.5%) of 90 patients had bilateral AVN, 35 femoral heads had early stage and 120 had advanced stage. The detection rate of AVN by X-ray and bone scan were 85% (134), 91.6% (143), respectively. Early AVN with atypical types of bone scan showed larger extent, moderate to large amount of joint effusion, soft tissue hypertrophy within joint, and secondary degenerative changes. Bone scan had relatively high detection rate in the diagnosis of AVN of femoral head, and demonstrated various types depending on the disease stage.

  • PDF

An experimental study on the dynamic teeth movement of 3 types of the insertion method of Precision-TPA for derotating the posterior teeth (Precision-TPA를 이용한 구치부 회전시 근심 및 원심삽입법에 따른 동적인 치아이동 양상에 관한 실험 연구)

  • Yang, Sung-Jae;Jung, Seong-Gweon;Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.425-433
    • /
    • 1999
  • Dr. Youn-Sic Chun and coworkers invented the new machine for getting information about the relative effectiveness of the orthodontic appliances and we named it Calorific machine. The author and colleagues used this machine to compare with tooth moving mechanism by 3 types of the insertion method of precision-TPA for derotating the posterior teeth. We measured the distance of tooth movement and found out the rotational center on the occlusal X-ray film and the tooth movement on the occlusogram and then processed paired t-test by SAS program, The results were as follows : 1. In the intermolar width, the mesial insertion method showed the loss oi distance, and the other methods(-distal insertion method, mesial expansion method-) showed the increase of distance. 2. In the arch length, the distal insertion method was exhibited as most recommandable way for increasing the arch length .3. The rotation center of the mesial insertion method for derotating the molar, was located between mesial pit and central pit of the lower End molar. And, in the distal insertion method, it was located between distal pit and distolingual cusp, and in the mesial expansion method was located at distal pit.

  • PDF

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

CT Findings and Accuracy of Preoperative Pathologic Diagnosis in Bronchial Carcinoid According to Subtype (기관지 유암종의 아형에 따른 CT 소견과 수술전 병리학적 진단의 정확성)

  • 임준석;홍용국;정경영;최규옥
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.380-387
    • /
    • 1998
  • We evaluated CT findings of bronchial carcinoid and accuracy of preoperative pathological diagnosis according to two subtypes. The subjects were 10 cases(typical;5, atypical;5), confirmed by surgery and tissue pathology. Sputum cytology(n=10), percutaneous aspiration(n=1) and bronchoscopic biopsy (n=8) were performed, preoperatively. The CT findings were analysed according to two subtypes. Typical carcinoid shows central location in all, and bronchial lumens just proximal to tumor were widened in two, whereas atypical carcinoid presented as peripheral leison in two. Among central atypical carcinoid, two cases showed flat meniscus appearance of lumen. Remaining one showed diffuse wall thickening. Intratumoral low density by necrosis was noted in one. Both subtypes show contrast enhancement. For preoperative diagnosis, sputum cytology & percutaneous aspiration were not conclusive at all. As for bronchoscopic biopsy, only 3 cases were accurately diagnosed as typical carcinoid. Typical carcinoid presented as endobronchial mass in all, whereas atypical carcinoid presented in various appearance. In all atypical & some typical carcinoid were misdiagnosed as primary lung cancer, preoperatively. However, in typical carcinoid, conservative surgery was possible. In conclusion, if there is discrepancy between CT findings & preoperative pathological diagnosis, full understanding of CT findings of bronchial carcinoid is imperative to choose appropriate surgical modality.

  • PDF

Layered structure of sialoliths compared with tonsilloliths and antroliths

  • Buyanbileg Sodnom-Ish;Mi Young Eo;Yun Ju Cho;Mi Hyun Seo;Hyeong-Cheol Yang;Min-Keun Kim;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.1
    • /
    • pp.13-26
    • /
    • 2024
  • Objectives: The aim of this study was to perform a comparative analysis of the ultrastructural and chemical composition of sialoliths, tonsilloliths, and antroliths and to describe their growth pattern. Materials and Methods: We obtained 19 specimens from 18 patients and classified the specimens into three groups: sialolith (A), tonsillolith (B), and antrolith (C). The peripheral, middle, and core regions of the specimens were examined in detail by histology, micro-computed tomography (micro-CT), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy, and transmission electron microscopy (TEM). Results: In the micro-CT, group A showed alternating radiodense and radiolucent layers, while group B had a homogeneous structure. Group C specimens revealed a compact homogeneous structure. Histopathologically, group A showed a laminated, teardrop-shaped, globular structure. Group B demonstrated degrees of immature calcification of organic and inorganic materials. In group C, the lesion was not encapsulated and showed a homogeneous lamellar bone structure. SEM revealed that group A showed distinct three layers: a peripheral multilayer zone, intermediate compact zone, and the central nidus area; groups B and C did not show these layers. The main elemental components of sialoliths were O, C, Ca, N, Cu, P, Zn, Si, Zr, F, Na, and Mg. In group B, a small amount of Fe was found in the peripheral region. Group C had a shorter component list: Ca, C, O, P, F, N, Si, Na, and Mg. TEM analysis of group A showed globular structures undergoing intra-vesicular calcification. In group B, bacteria were present in the middle layer. In the outer layer of the group C antrolith, an osteoblastic rimming was observed. Conclusion: Sialoliths had distinct three layers: a peripheral multilayer zone, an intermediate compact zone and the central nidus area, while the tonsillolith and antrolith specimens lacked distinct layers and a core.

Endobronchial Metastasis of Extrapulmonary Malignancies (폐외 악성 종양의 기관지내 전이)

  • Kim, Do-Hoon;Park, Moo-Suk;Chung, Jae-Ho;Cheong, Jae-Hee;Kim, Se-Kyu;Chang, Joon;Kim, Sung-Kyu;Kim, Young-Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.285-293
    • /
    • 2002
  • Background : The lung is the most common site for a metastasis of extrapulmonary malignant tumors. however, reports on an endobronchial metastasis are rare. An endobronchial metastasis is defined as a documented extrapulmonary neoplasms metastatic to the segmental or more proximal central bronchus within a bronchoscopically visible range. The purpose of this study was to define the clinical characteristics of an endobronchial metastasis of extrapulmonary malignancies. Materials and Methods : The clinical features and treatment outcomes of 27 endobronchial metastatic cancer cases were reviewed from June, 1991 to May, 2001 in the Severance Hospital. Results : The patients' age ranged from 18 to 75. There were 17 men and 10 women. The primary tumors included the colorectum in 7, the uterine cervix in 4, the stomach and the breast in 3 patients each, and an osteosarcoma in 2 patients. The main complaint of most patients was coughing and a chest X-ray revealed a hilar mass, a parenchymal, and an atelectasis. The mean recurrence interval time was 45.5 months. The median and mean survival times were 10 and 12.3 months, respectively. Conclusion : An endobronchial metastasis is an ominous finding, and is associated with advanced-stage diseases. It requires differential diagnosis with a primary bronchogenic carcinoma. If atypical clinical features are present or an atypical cell type is discovered by a biopsy of the lesion in the lung mass, the appropriate diagnostic studies should be undertaken.

Peripheral Neuroblastoma of the Ulnar Nerve : Diagnosis by Fine Needle Aspiration Cytology (척골신경에 발생한 말초성 신경아세포종 -세침흡인 세포검사로 진단된 1례 보고-)

  • Chu, Young-Chae;Kim, Joon-Mee
    • The Korean Journal of Cytopathology
    • /
    • v.4 no.1
    • /
    • pp.45-51
    • /
    • 1993
  • A 30-year-old woman who was diagnosed as peripheral neuroblastoma by fine needle aspiration of a soft mass of the right upper arm is described. She presented a slowly growing, soft mass of the right upper arm for 1 month. The right humerus revealed no abnormal finding on X-ray. Ultrasonogram of the right upper arm revealed a well demarcated, smooth marginated solid mass without invasion of adjacent structures. Fine needle aspiration was done under the impression of soft tissue tumor with undetermined biologic behavior. The aspirates were highly cellular and the tumor cells were dispersed both singly and in clusters of varying size. The clusters occasionally showed a central capillary core and rosette-like structures. The tumor cells were small in size and had a small to medium amount of cytoplasm. Some of them revealed slender cytoplasmic processes. The nuclei showed distinct nuclear membranes, finely clumped chromatin and small conspicuous nucleoli. Cellular pleomorphism or mitotic figure was not definite. These cytologic findings were interpreted as a malignant, non-lymphomatous small round cell tumor, most likely representing peripheral neuroblastoma or Ewing's sarcoma. Final diagnosis was confirmed by simple excision as peripheral neuroblastoma.

  • PDF

Interpretation of Construction Procedure and Physicochemical Characteristics for Soil Layers from Sowangneung (Small Royal Tomb) of Ssangneung (Twin Tombs) in Iksan, Korea (익산 쌍릉 소왕릉 봉분 토층의 물리화학적 특성과 조영과정 해석)

  • Chae, Joon;Park, Seok Tae;Cho, Ji Hyun;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.748-766
    • /
    • 2021
  • The Iksan Ssangneung (twin tombs), a pair of tombs comprising the Daewangneung (large royal tomb) and the Sowangneung (small royal tomb), were constructed in the typical style of stone tunnel and chamber tombs in the Baekje Kingdom during the Sabi period (538 to 660 AD) of ancient Korea. Soil layers exposed during excavation of Sowangneung in a trench east of the tomb are: the bottommost layer, the ground level layer, the Panchuk (rammed earth) layer of the Baekje, the layer created by a grave robbery, and soil recovered during the Japanese colonial period. Soil samples were obtained by segmenting an easy stratigraphic horizon into sub categorized soil layers, and their material properties were analyzed; they are composed mainly of sandy loam based on the particle size distributions. In the site foundation, loamy sand is packed in the bottommost layer, and sandy loam with high sand and silty sand fills most of the overlying layer. The central and topmost portion of the Baekje layer is composed of loam with high clay content. All soil layers show geochemical behaviors similar to those of the bottommost layer. X-ray diffraction analysis verified kaolinite in all layers, also observed in soil layers displaying high crystallinity. Kaolinite and halloysite were identified by scanning electron microscopy. Thus, we conclude that the Baekje layer of the Sowangneung is composed of sandy loam containing kaolin procured from near the site. An impermeable middle to upper layer was created using viscous loam. The top of the tomb was closed tightly.

Analysis of Tissue Equivalent Characteristics of Agar Phantom for Hyperthermia Therapy (온열종양치료 한천 팬텀의 조직등가 특성 분석)

  • Jeong-Geun Park;Kyeong-Hwan Jeong;Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.985-991
    • /
    • 2023
  • A tissue-equivalent phantom is necessary for quality control of hyperthermia therapy. However, since there is no phantom for this purpose, phantoms made from agar are being used in various studies. The tissue-equivalent properties of the agar phantom were confirmed by comparison with the tissue-equivalent material bolus in this study. CT images of the agar phantom and bolus were acquired, and tissue equivalent characteristics were analyzed with image analysis and dose calculation using a computerized radiation therapy planning system. The average pixel value was 96.960±10.999 in bolus, 108.559±8.233 in 3% agar phantom, and 111.844±8.651 in 4% agar phantom. Using the SSD technique, 100 cGy was prescribed at a depth of 1.5 cm and 6 MV X -ray was set to irradiated to 10x10 cm2, and the absorbed dose according to depth was calculated from the central axis of the beam. The intraclass correlation coefficient of dose distribution of bolus, 3% agar phantom, and 4% agar phantom was 0.979 (p<.001, 95%CI .957-.991). The density (g/cm3) at the point where the absorbed dose was calculated was 0.990±0.020 at the bolus, 1.018±0.020 at the 3% agar phantom, and 1.035±0.024 at the 4% agar phantom. In this study, the internal density distribution and uniformity of the agar phantom were confirmed to be appropriate as a tissue equivalent material by analysis of CT images and a computerized radiation therapy planning system.

A Study on the Peripheral Dose of 6MV X-ray Beam (6 MV X선의 주변선량분포)

  • Choi, Doo-Ho;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.24-33
    • /
    • 1989
  • The peripheral dose, defined as the dose outside therapeutic photon fields, was estimated for 6MV X-ray linear accelerator. The measurements were performed using silicon diode detectors controlled by automatic controlled water phantom. The effects of field size, collimator position, presence or absence of wedge filter, and wedge angle were analyzed. The results were as follows 1. The peripheral dose decreases as the distance from field margin increases and it is more than 2.4% of central axis maximum dose even at 15cm distance from field margin. 2. Maximum build-up of peripheral dose is at 2-3 mm from the water surface and drops to a minimum at 1.5cm depth and then the dose increase again. 3. The peripheral dose increases as the field size. increases. At the short distance from field margin, the difference of peripheral dose between 5 $\times\;5cm^2$ and 20 $\times\;20cm^2$ field size reaches more than 2 fold. 4. The peripheral dose is higher along the upper collimator than along the lower collimator. The differences is less than 1%. 5. The presence of wedge filter increases peripheral dose. And the peripheral dose is higher along the blade side of wedge filter than along the ridge side. The difference is about 3% at 5cm distance from the field margin for 15 $\times\;15cm^2$ field size and 60$^{\circ}$ wedge filter. 6. The Peripheral dose of wedge filter increases as the wedge filter angle increases and the increasing ratio is about 2 fold in 60$^{\circ}$wedge filter compared with open field.

  • PDF