• Title/Summary/Keyword: Central Operator

Search Result 82, Processing Time 0.02 seconds

ON JORDAN AND JORDAN HIGHER DERIVABLE MAPS OF RINGS

  • Liu, Lei
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.4
    • /
    • pp.957-972
    • /
    • 2020
  • Let 𝓡 be a 2-torsion free unital ring containing a non-trivial idempotent. An additive map 𝛿 from 𝓡 into itself is called a Jordan derivable map at commutative zero point if 𝛿(AB + BA) = 𝛿(A)B + B𝛿(A) + A𝛿(B) + 𝛿(B)A for all A, B ∈ 𝓡 with AB = BA = 0. In this paper, we prove that, under some mild conditions, each Jordan derivable map at commutative zero point has the form 𝛿(A) = 𝜓(A) + CA for all A ∈ 𝓡, where 𝜓 is an additive Jordan derivation of 𝓡 and C is a central element of 𝓡. Then we generalize the result to the case of Jordan higher derivable maps at commutative zero point. These results are also applied to some operator algebras.

A Normal Vector Estimation Method using Improved Central Difference Operator (가변 중심 편차 연산자를 이용한 법선 벡터 추정방법)

  • Sin, Byeong-Seok
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.26 no.6
    • /
    • pp.627-635
    • /
    • 1999
  • 물체의 3차원 모델을 음영처리하기 위해서는 물체 표면의 각 점에서 법선 벡터를 계산해야 한다. 복섹 기반의 볼륨 데이터는 표면에 대한 기하학적 정보가 없기 때문에 이웃 점들의 상대적인 위치나 데이터 값의 차이로부터 법선 벡터를 추정할 수 밖에 없다. 기존에 고안된 법선 벡터추정 연산자는크기가 고정되어 있기 때문에 제한된 영역에서만 법선 벡터를 정확하게 계산하고 나머지 영역에서는 오류를 유발한다. 이 논문에서는 표면을 구성하는 점들의 공간적 배치나 그 점들의 데이터값에 따라 크기가 변하는 가변 중심 편차 연산자와 이를 이용한 법선 벡터 추정 방법을 제안한다. 이 연산자를 사용하면 기존연산자들보다 정확하게 법선 벡터를 추정할 수 있으며, 동일한 화질인 경우 계산 시간이 상당히 단축된다.

Recognition of a Close Leading Vehicle Using the Contour of the Vehicles Wheels (차량 뒷바퀴 윤곽선을 이용한 근거리 전방차량인식)

  • Park, Kwang-Hyun;Han, Min-Hong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.3
    • /
    • pp.238-245
    • /
    • 2001
  • This paper describes a method for detecting a close leading vehicle using the contour of the vehi-cles rear wheels. The contour of a leading vehicles rear wheels in 속 front road image from a B/W CCD camera mounted on the central front bumper of the vehicle, has vertical components and can be discerned clearly in contrast to the road surface. After extracting positive edges and negative edges using the Sobel op-erator in the raw image, every point that can be recognized as a feature of the contour of the leading vehicle wheel is determined. This process can detect the presence of a close leading vehicle, and it is also possible to calculate the distance to the leading vehicle and the lateral deviation angle. This method might be useful for developing and LSA (Low Speed Automation) system that can relieve drivers stress in the stop-and-go traffic conditions encoun-tered on urban roads.

  • PDF

(Distance and Speed Measurements of Moving Object Using Difference Image in Stereo Vision System) (스테레오 비전 시스템에서 차 영상을 이용한 이동 물체의 거리와 속도측정)

  • 허상민;조미령;이상훈;강준길;전형준
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.9
    • /
    • pp.1145-1156
    • /
    • 2002
  • A method to measure the speed and distance of moving object is proposed using the stereo vision system. One of the most important factors for measuring the speed and distance of moving object is the accuracy of object tracking. Accordingly, the background image algorithm is adopted to track the rapidly moving object and the local opening operator algorithm is used to remove the shadow and noise of object. The extraction efficiency of moving object is improved by using the adaptive threshold algorithm independent to variation of brightness. Since the left and right central points are compensated, the more exact speed and distance of object can be measured. Using the background image algorithm and local opening operator algorithm, the computational processes are reduced and it is possible to achieve the real-time processing of the speed and distance of moving object. The simulation results show that background image algorithm can track the moving object more rapidly than any other algorithm. The application of adaptive threshold algorithm improved the extraction efficiency of the target by reducing the candidate areas. Since the central point of the target is compensated by using the binocular parallax, the error of measurement for the speed and distance of moving object is reduced. The error rate of measurement for the distance from the stereo camera to moving object and for the speed of moving object are 2.68% and 3.32%, respectively.

  • PDF

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography (삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구)

  • Yoon, Jong-Tae;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes (X선관의 실효초점 측정에 관한 고찰)

  • Chang, Kwang-Hyun;Lim, Oh-Soo;Kim, Hyung-Kee;Song, Chang-Wook;Cheung, Kyung-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

CHARACTERIZATIONS OF CENTRALIZERS AND DERIVATIONS ON SOME ALGEBRAS

  • He, Jun;Li, Jiankui;Qian, Wenhua
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.2
    • /
    • pp.685-696
    • /
    • 2017
  • A linear mapping ${\phi}$ on an algebra $\mathcal{A}$ is called a centralizable mapping at $G{\in}{\mathcal{A}}$ if ${\phi}(AB)={\phi}(A)B= A{\phi}(B)$ for each A and B in $\mathcal{A}$ with AB = G, and ${\phi}$ is called a derivable mapping at $G{\in}{\mathcal{A}}$ if ${\phi}(AB)={\phi}(A)B+A{\phi}(B)$ for each A and B in $\mathcal{A}$ with AB = G. A point G in A is called a full-centralizable point (resp. full-derivable point) if every centralizable (resp. derivable) mapping at G is a centralizer (resp. derivation). We prove that every point in a von Neumann algebra or a triangular algebra is a full-centralizable point. We also prove that a point in a von Neumann algebra is a full-derivable point if and only if its central carrier is the unit.

An Adaptive Virtual Machine Location Selection Mechanism in Distributed Cloud

  • Liu, Shukun;Jia, Weijia
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.12
    • /
    • pp.4776-4798
    • /
    • 2015
  • The location selection of virtual machines in distributed cloud is difficult because of the physical resource distribution, allocation of multi-dimensional resources, and resource unit cost. In this study, we propose a multi-object virtual machine location selection algorithm (MOVMLSA) based on group information, doubly linked list structure and genetic algorithm. On the basis of the collaboration of multi-dimensional resources, a fitness function is designed using fuzzy logic control parameters, which can be used to optimize search space solutions. In the location selection process, an orderly information code based on group and resource information can be generated by adopting the memory mechanism of biological immune systems. This approach, along with the dominant elite strategy, enables the updating of the population. The tournament selection method is used to optimize the operator mechanisms of the single-point crossover and X-point mutation during the population selection. Such a method can be used to obtain an optimal solution for the rapid location selection of virtual machines. Experimental results show that the proposed algorithm is effective in reducing the number of used physical machines and in improving the resource utilization of physical machines. The algorithm improves the utilization degree of multi-dimensional resource synergy and reduces the comprehensive unit cost of resources.