• Title/Summary/Keyword: Center-point error

Search Result 257, Processing Time 0.024 seconds

Landmarks in The Skull for Stereotactic Radiotherapy

  • Hiroki, Ohtani;Toraji, Irifune;Etsuo, Kunieda;Hidetoshi, Saitoh;Masahiro, Fukushi;Tsuguhisa, Katoh
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.144-145
    • /
    • 2002
  • Stereotactic radiotherapy is required to irradiate a small tumor accurately. The radiotherapy showing improves when making an accidental error little boundlessly. It is performed according to treatment planning that is established by the outside landmark of head. At present, when stereotactic radiotherapy for a head is done, the Leksell Flame is fixed on the head, and positioning based on the point and so on which it is in that fixed implement is performed. However, there are problems on the method done at present in the point such as reappearance when the fractionated irradiation method in which the Leksell Flame is removed and installed at every treatment is done because there are landmarks outside the head. Landmarks in the skull were decided, and that precision was examined for the purpose of the improvement of the radiation therapeutic gain. Linac-graphy with longitudinal and lateral view were taken with 6 MV photon beams. A distance to base point inside the skull, each film measured the angle from a center of the small irradiation field, and comparison was done. From the results, a large accidental error wasn't seen as a result of the measurement by every film. Stereotactic radiotherapy for a head treatment had an accidental error of about several millimeters when treatment positioning was done. Therefore, it was thought that there was no problem about an accidental error to arise by putting a landmark in the skull. And, because an accidental error was easy to discover, we thought that modification could be done easily. It was suggested that a landmark in the skull on thus study were useful for improvement of stereotactic radiotherapy.

  • PDF

Ultra-precision single point diamond turning (SPDT) on an aspheric metal secondary mirror (초정밀 단일점 다이아몬드 터닝을 이용한 비구면 금속 부반사경 가공)

  • Kim, E. D.;H. S. Yang;Kim, G-H.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.96-97
    • /
    • 2001
  • A 110 mm diameter aspheric metal secondary mirror for a test model of an earth observation satellite camera was fabricated by ultra-precision single point diamond turning (SPDT) . Without a conventional polishing process, the surface texture of R$\sub$a/=2.8 nm, and the form error of R$\sub$a/=0.05 λ has been stably achieved In a laboratory condition. (omitted)

  • PDF

Analysis of the Metal Flow in H-Beam Rolling using Beam Blank (빔 블랑크를 이용한 H 형강 압연 거동 연구)

  • Kim, J.M.;Choi, W.N.;Park, C.S.;Kim, K.W.
    • Transactions of Materials Processing
    • /
    • v.22 no.7
    • /
    • pp.383-388
    • /
    • 2013
  • Metal flow of the beam blank during H-beam rolling was examined in order to correlate the rolling defects with the beam blank configuration. For this purpose, H-beam rolling was performed on the beam blank where stainless steel bolts were inserted as the marker at the web and flange. The positional variation of the marker was monitored at each rolling pass, and the result was compared with the 3D FEM simulation employing the point tracking function. The simulation results were reasonably agreed with the experimental within the error of 0.5~1mm on both web and flange of the H-beam. It is anticipated that the 3D FEM simulation employing the point tracking function provides the guidance information on analyzing the correlation between the rolling defects and the beam blank configuration in H-beam rolling.

Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target (표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가)

  • Choi, Young Se;Park, Hyo Kuk;Kim, Se Young;Kim, Joo Ho;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose: To evaluate the usefulness of the $HexaPOD^{TM}$ evo RT system(6DoF couch) and the tendency of dose difference according to size of rotational direction error for volumetric rotational modulated radiotherapy(V-MAT) in patients with long target lengths. Therefore, it is suggested to recommend the need for rotational error correction. Materials and Methods: Ten patients with Esophagus cancer or Breast cancer including SCL treated with HexaPOD 6DoF(Six-Degree of Freedom) couch were included in this study. 6DoF couch was used to measure the difference in dose according to the rotation error in the directions of Rx(pitch), Ry(roll), and Rz(yaw). Each rotation error was applied. Positioning variation on x, y and z axis was verified and random variations were made by 6DoF couch with positioning variation. Modified DQA is conducted and point dose and gamma value are analyzed and compared. In addition, after applying the rotation error every $1^{\circ}$ to treatment plans of each target with a diameter of 3 cm, 5, 10, 15, and 20 cm respectively, gamma passing rate is being monitored by its aspect of change according to types and sizes of the target length and rotation error. Results: Mean error of the point dose and Gamma passing rate when the position variation was applied were $2.50{\pm}1.11%$ and $84.1{\pm}7.39%$ in the Rx direction, $2.36{\pm}1.16%$, and $81.0{\pm}8.49%$ in the Ry, $2.35{\pm}1.10%$ and $84.4{\pm}6.99%$ in the Rz direction, respectively. As a result of analysis on gamma passing rate according to types and sizes of the target length and rotation error, the gamma passing rate tended to decrease with increasing rotation error in the Rx and Rz directions except Ry direction. In particular, the lowest gamma passing rate (74.2 %) was in the case of $2.5^{\circ}$ rotation error in Rz direction of the target of 10 cm. Conclusion: The correction of the rotational error is needed for volumetric modulated radiotherapy of the treatment area with a long target length, and the use of 6DoF couch will improve the reproducibility of the patient position and the quality of the treatment.

  • PDF

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

A study of an OMM system for machined spherical form measurement using the volumetric error compensation of Machining Center (머시닝센터의 오차보상을 통한 구면 가공형상 측정 OMM 시스템 연구)

  • 이찬호;오창진;이응석;김성청
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.838-841
    • /
    • 2000
  • To improve the accuracy of products and improve the product quality, we need to enhance the machining accuracy of the machine tools. To this point of view, measurement and inspection of finished part as well as error analysis of machine tools has been studied for last several decades. OMM(On the Machine Measurement) has been issued to alternate with CMM, pointing out disadvantages of high expenses and lots of setting time in CMM. In this paper, we study 1) the spherical surface manufacturing by volumetric error compensation of machine tool, 2) the system development of OMM without detaching work piece from a bed of machine tool after working. 3) the generation of the finished part profile by On the machine measurement. Furthermore, the output of OMM is compared with that of CMM, and verified the feasibility of the measurement system.

  • PDF

Analysis of the Influence of Atmospheric Turbulence on the Ground Calibration of a Star Sensor

  • Xian Ren;Lingyun Wang;Guangxi Li;Bo Cui
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.38-44
    • /
    • 2024
  • Under the influence of atmospheric turbulence, a star's point image will shake back and forth erratically, and after exposure the originally small star point will spread into a huge spot, which will affect the ground calibration of the star sensor. To analyze the impact of atmospheric turbulence on the positioning accuracy of the star's center of mass, this paper simulates the atmospheric turbulence phase screen using a method based on a sparse spectrum. It is added to the static-star-simulation device to study the transmission characteristics of atmospheric turbulence in star-point simulation, and to analyze the changes in star points under different atmospheric refractive-index structural constants. The simulation results show that the structure function of the atmospheric turbulence phase screen simulated by the sparse spectral method has an average error of 6.8% compared to the theoretical value, while the classical Fourier-transform method can have an error of up to 23% at low frequencies. By including a simulation in which the phase screen would cause errors in the center-of-mass position of the star point, 100 consecutive images are selected and the average drift variance is obtained for each turbulence scenario; The stronger the turbulence, the larger the drift variance. This study can provide a basis for subsequent improvement of the ground-calibration accuracy of a star sensitizer, and for analyzing and evaluating the effect of atmospheric turbulence on the beam.

Application of the GPS & EDM System for 3D Orthophoto in Small Area (소규모지역에서 3차원 정사사진 구현을 위한 GPS와 EDM의 적용)

  • Choi Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.890-896
    • /
    • 2006
  • It's very difficult to acquire the accurate GCP(Ground Control Point) in the urban center and forest aerial photo because of occurring of irregular multi-path error. The purpose of this study is to apply the CPS and the EDM system for 3D orthophoto in the small areas. GCPs surveyed by accuracy triangulation from EDM after from triangulation points to a fiducial point at study area used to GPS. And I have a comment on how to use areal orthophoto for future 3D-GIS after 3D-Modelling using areal orthophoto. As the results, EDM surveying could resolve multi-path error according to GPS surveying and It is possible for using aerial orthophoto on the basis of the 3D-GIS database.

Implementation of Digital Signal Processing Board Suitable for a Semi-active Laser Tracking to Detect a Laser Pulse Repetition Frequency and Optimization of a Target Coordinates (반능동형 레이저 유도 추적에 적합한 레이저 펄스 반복 주파수 검출을 위한 디지털 신호처리 보드 구현 및 표적 좌표 최적화)

  • Lee, Young-Ju;Kim, Yong-Pyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.573-577
    • /
    • 2015
  • In this paper, we propose a signal processing board suitable for a semi-active laser tracking to detect an optical signal generated from the laser target designator by applying an analog trigger signal, the quadrant photodetector and a high speed ADC(analog-digital converter) sampling technique. We improved the stability by applying the averaging method to minimize the measurement error of a gaussian pulse. To evaluate the performances of the proposed methods, we implemented a prototype board and performed experiments. As a result, we implemented a frequency counter with an error 14.9ns in 50ms. PRF error code has a stability of less than 1.5% compared to the NATO standard. Applying the three point averaging method to ADC sampling, the stability of 28% in X-axis and 22% in Y-axis than one point sampling was improved.

Measurement Technique for Sea Height of Burst Using Image Recognition

  • Park, Ju-Ho;Hong, Sung-Soo;Kang, Kyu-Chang;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.76-83
    • /
    • 2000
  • A measurement technique of a sea height of burst is introduced for a proximate test using the image recognition of video cameras. In the burst of fuse on the ocean, the burst center of fuse, the sea surface level and the height of calibration poles are measured by the process of image obtained from cameras. Finally, the height of burst of fuse can be computed by Hough transform algorithm. The error compensation algorithms are proposed to eliminate the errors caused by camera level and environmental parameters. As a result of experiment, it has been proved that the proposed measurement system shows the recognition of the center point of the burst image with ${\pm}$0.5m error.

  • PDF